Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Demonstration of $E$ acc = 10 MV m −1 with Nb 3 Sn cavities in a cryomodule

Accelerating cryomodules with superconducting cavities are key components for particle accelerators. The efficiency, energy gain and operating temperature of cavities drive the operating and capital costs; hence, advances in these areas enable future accelerators. While superconducting cavities are currently made from Nb, Nb 3 Sn, with a superconducting transition temperature and superheating field approximately twice that of Nb, is poised to substantially improve the efficiency and energy gain. We present results from the first cryomodule with two five-cell 1.5 GHz superconducting radiofrequency Nb cavities coated with Nb 3 Sn, which attained an accelerating gradient of ⩾10 MV m −1 with low cryogenic loss at 4.4 K.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Superconducting low-beta Nb 3 Sn cavity for ATLAS and future ion accelerators

We report on a Nb 3 Sn-coated low-beta superconducting radio frequency (RF) cavity intended for accelerating ions. We aim to apply the cavity in ATLAS, our Argonne National Laboratory user facility for nuclear physics studies with ion beams in the energy range of 5–20 MeV u −1 . The Nb 3 Sn-coated cavity, a 145 MHz quarter-wave optimized for ions moving with velocity β = $v/c$ = 0.08 exhibits an order-of-magnitude reduction in RF losses into helium at 4.4 K compared to a superconducting niobium (Nb) cavity at the same frequency and temperature. Experimentally measured fields are among the highest to date for any Nb 3 Sn-coated cavity, reaching a peak surface magnetic field of 105 mT. We also present a practical solution to the problem of cavity frequency tuning. Tuning by mechanical deformation has been a challenge with Nb 3 Sn due to its brittle nature, however, using a set of techniques tailored to the properties of thin-film Nb 3 Sn on Nb, we can repeatably tune the cavity to the ATLAS master clock frequency after it is cooled, while maintaining the excellent performance characteristics. The same Nb 3 Sn cavity technology offers broad benefits for future ion accelerators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Recent advance progress of HL-3 experiments

Since the first plasma realized in 2020, a series of key systems on HL-3 (known as HL-2M before) tokamak have been equipped/upgraded, including in-vessel components (the first wall, lower divertor, and toroidal cryogenic/water-cooling/baking/glow discharge systems, etc.), auxiliary heating system of 11 MW, and 28 diagnostic systems (to measure the plasma density, electron temperature, radiation, magnetic field, etc.). Magnet field systems were commissioned firstly for divertor plasma discharges. During the 2nd experimental campaign of HL-3 tokamak, several great progresses have been achieved. Firstly, the successful operation with plasma current larger than 1 MA was achieved under a divertor configuration. Secondly, the advanced divertor concept with two distinct snowflake configurations was realized. It is found that the distribution of ion saturation current and heat flux on bottom plate becomes wide due to magnetic surface expansion, demonstrating the advantage of such configuration in the heat flux mitigation. In addition, using the combination of NBI, ECRH and LHCD, the standard sawtoothing high confinement mode of megampere plasma was firstly accessed on the HL-3. The successful commissioning of HL-3 is beneficial for the initial operation of ITER.

1 MA plasma↗

Bias-hardened estimators of patchy screening profiles

Detecting anisotropic screening of the cosmic microwave background (CMB) holds the promise of revealing the distribution of gas in the Universe, characterizing the complex processes of galaxy formation and feedback, and studying the epoch of reionization. Estimators for inhomogeneous screening, including some recently proposed small-scale (stacked) estimators, are quadratic or higher order in the CMB temperature or polarization fields and are therefore subject to contamination from CMB lensing. We review the origin of this lensing bias and show that, when stacking on unWISE galaxies, the expected lensing bias dominates the signal if left unmitigated. Hardening techniques that null the lensing bias have been proposed for standard quadratic estimators, whereas only approximate methods have been proposed for stacked estimators. In conclusion, we review these techniques and apply the former to stacked estimators, presenting several strategies (including the optimal strategy) to null lensing contamination when stacking on any large-scale structure tracer.

Cosmic microwave background↗

Weak localization as a probe of intervalley coherence in graphene multilayers

Spontaneous intervalley coherence is suspected in several different graphene multilayer systems, but is difficult to confirm because of a paucity of convenient experimental signatures. Here we suggest that magneto-conductance features associated with quantum corrections to Drude conductivity can serve as a smoking gun for intervalley coherence that does not break time-reversal symmetry. In this class of ordered multilayer quantum transport corrections can produce weak localization or weak antilocalization, depending on whether the valley order belongs to the orthogonal or symplectic symmetry class. Our analysis motivates low-temperature weak-field magnetoresistance measurements in graphene multilayers in which time-reversal invariant intervalley coherent order is conjectured.

36 MATERIALS SCIENCE↗

Nontrivial critical behavior at magnetic transitions: A case study of Sm 7 ⁢Pd 3

We present a comprehensive analysis of the critical behavior of Sm 7 ⁢Pd 3 in the vicinity of its second-order magnetoelastic transition at 𝑇 c =173 K. The critical exponents (CEs) 𝛽 and 𝛾, determined using both the standard convergence procedure and the average normalized slope (ANS) method, diverge at 𝑇 c –-a characteristic typically associated with first-order transitions. Notably, none of the established universality classes satisfactorily describe the critical behavior of Sm 7 ⁢Pd 3 , and we discuss the possible origins of this deviation in the context of the strong spin-lattice coupling intrinsic to the sample. We emphasize the importance of accurately selecting the critical temperature and magnetic field ranges to ensure robust critical behavior analysis, and propose a quantitative approach to assess the reliability of the extracted CEs. Additionally, we demonstrate that in the ANS method, the critical exponents 𝛽 and 𝛾 should be calculated separately using data for 𝑇 ⩽ 𝑇 c and 𝑇 ⩾ 𝑇 c , respectively. In conclusion, our findings underscore the need for a revised theoretical framework to accurately describe second-order magnetoelastic transitions.

Ferrimagnets↗

Increasing Multilayer Ceramic Capacitor Lifetime With Bipolar Voltage Cycling

Enhancing the lifetime of multilayer ceramic capacitors (MLCCs) is critical in many aerospace, naval, or electrical grid applications, where device failure could lead to catastrophic consequences. The migration of oxygen vacancies from the ceramic to the electrode interface under constant bias is known to reduce the lifetime of oxide-based MLCCs. Bias cycling presents an opportunity to enhance MLCC lifetime by reducing oxygen vacancy migration. The ideal frequency range is expected to lie between frequencies low enough to avoid self-heating but high enough to avoid interfacial defect formation. However, the impact of low-frequency bipolar voltage cycling (BVC) on MLCC degradation mechanisms has not been well studied. This work investigates the impact of periodic BVC on the degradation of MLCCs through highly accelerated lifetime testing (HALT) on X7R capacitors. HALT tests were conducted at 255 °C and 60 V using different switching frequencies: 0 (dc), 0.1, 2.5, and 10 Hz. BVC was found to improve the lifetime of MLCCs compared to dc test conditions. MLCCs tested at 10-Hz BVC showed a 311% increase in average time to failure compared to the dc case. Impedance spectroscopy shows that BVC decreases the rate of resistance degradation within MLCCs, indicating that oxygen vacancy migration to the electrodes is mitigated. The impedance spectra taken on BVC samples highlight how grain boundaries play a vital role in trapping oxygen vacancies. Periodic cycling causes oxygen vacancies to become trapped at grain boundaries, resulting in oxygen vacancies taking longer to reach the electrode interface and thus increasing MLCC lifetime. This work highlights not only how BVC can be used to increase MLCC lifetime but also how periodically cycling MLCCs could increase lifetime in extreme environments, such as at elevated temperatures and electric fields.

Chuong, Kayla Y.↗

Investigating Low Loss Substrates for Improved Qubit Coherence Times

Superconducting qubits are sensitive to dielectric losses from substrates, making the identification, optimization, and preparation of low-loss materials essential for enhancing qubit coherence times. In this work, we utilize Nb superconducting radio-frequency (SRF) cavities as a high-precision measurement tool to study the dielectric loss tangent of substrates with parts-per-billion sensitivity. This technique enables temperature- and field-resolved measurements, providing deep insights into the behavior of candidate materials such as sapphire and silicon. We explore the impact of substrate preparation techniques, examining how surface treatments and cleaning protocols influence dielectric loss. These studies highlight both the microscopic origins of loss in these substrates and the critical role of preparation methods, helping to identify key materials and processes that minimize dielectric loss, crucial for improving qubit performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Turbulent Processes that Influence Boundary-Layer Cloud Structure (Final Technical Report)

Many models of the atmosphere simulate vertical profiles of observable fields, such as temperature, moisture, and vertical velocity. To assess the realism of such model output, it is important to evaluate the modeled profiles against observations. However, many extant evaluations consist of comparing time averaged profiles from the model and the observations. Such time averages can smooth out unrealistic features that appear in instantaneous profiles. In this way, the time averages may obscure certain model errors from detection. For instance, many models misrepresent turbulent processes, leading to profiles that are too smoothed out or too noisy. E.g., if a model has coarse vertical resolution and overly strong diffusion, then the model may be unable to produce observed sharp peaks. On the other hand, a model may have artificial approximations that produce spurious jumps in the vertical. Much can be learned by browsing through instantaneous snapshots of model output. But the volume of output produced by a global model is far too great to rely purely on visual inspection. In addition, we need a way to statistically characterize the profiles, so that anomalies can be detected more conveniently.

54 ENVIRONMENTAL SCIENCES↗

Mechanical Actuation Mechanism Design for Cryogenic Microwave Cavities in Axion Dark Matter Searches

Resonant Microwave Cavities are placed in a strong magnetic field at cryogenic temperatures (~.1K) in order to try to convert axions into detectable photons. A major challenge is to tune the cavity to allow no interference with the desired environment used for the experiment, which enables the system to operate near absolute zero and maintain superconductivity, thereby reducing noise as much as possible. My project focuses on developing and testing a low-thermal-conductivity gear reduction system with a 1000:1 ratio for cavity tuning. This gear system could significantly improve the thermal and electromagnetic interference of the tuning mechanism, helping ADMX scan for axions more accurately.

Ortega, Giancarlo [Marquette U.; Fermilab]↗

Comparative Analysis of HEATNETS for Geothermal Network Performance

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Comparative Analysis of HEATNETS for Geothermal Network Performance: Preprint

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer, rather than also comparing control systems responses. HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study shows that HEATNETS, while not intended to replace other modeling tools, can be a unique modeling tool for the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

In Situ Atmospheric Plume Thermometry via Carbon Monoxide Spectral Profile: Laboratory and Field Validation

For small molecules with large rotational constants, knowing the relative intensities of the ro-vibrational transitions can be used to determine the temperature within a gas plume. We demonstrate the use of carbon monoxide (CO) as an in situ spectroscopic probe of gas plume temperature by application of both laboratory and standoff Fourier transform infrared spectroscopy to monitor the CO spectral response at different temperatures. Here, the measured CO rotational contours were analyzed using a simple Boltzmann model to deduce the population distribution of the J-levels, from which the in-plume temperature is deduced. The method was vetted by comparing deduced temperatures in both static laboratory measurements of known temperatures, as well as field measurements using a simulated smokestack release. For the smokestack experiments, spectroscopically deduced temperatures were compared to readings from a series of thermocouples placed at strategically sampled distances along the plume trajectory. Both the spectroscopically-derived and thermocouple-measured temperatures revealed an expansion-induced (mixing) rapid cooling of the plume, with the infrared thermometry values displaying greater temperature values which are believed to better represent the actual plume temperatures.

Analysis of rotational structure↗

Infrared Thermometer Instrument Handbook

The infrared thermometer (IRT) is a ground-based radiation pyrometer that provides measurements of the brightness temperature of the scene in its field of view. The ground IRT (sometimes referred to as the upwelling instrument) lens has a wide field of view for measuring the radiating temperature of the ground surface. It measures in a narrow range of the infrared band, details of which can be found in Table 2. It provides data to the user averaged to 1-minute resolution. The infrared thermometer for sea-surface temperature (IRTSST) is a ship-based radiation pyrometer that provides measurements of the temperature of the sea surface. The upwelling infrared emission is determined with two different IRTs for over-ocean field campaigns and the data is at 1-second temporal resolution. The IRTs are mounted at heights varying between 2 and 42 m above the ground, oriented so the mounting platform and other human made objects are not in the field of view, and also to ensure that the ground and vegetation cover are representative of the local area. The Heitronics IRT is generally mounted inside a small enclosure, and the Apogee IRT is shielded by a cylindrical enclosure that is part of the design from the manufacturer.

47 OTHER INSTRUMENTATION↗

Quality and Loss Factor Characterization of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons under a strong magnetic field through resonant cavity techniques. The conversion produces an extremely small signal, requiring a cryogenic environment to reduce thermal noise, and low-loss superconducting transmission lines for minimal attenuation in the readout chain. Yttrium barium copper oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss cryogenic cables such as niobium (Nb) and niobium titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We characterized the quality and loss of five stripline resonators from the Brookhaven Technology Group: three YBCO, a copper reference, and a silver reference. Experimental methodology included collecting scattering parameter data on a vector network analyzer for the samples at 77 K along with room temperature baseline measurements, and employing both Lorentzian-fit and circle-fitting techniques to confirm the coupling regime and corroborate results. We achieved quality factors on the order of $10^3$ with corresponding loss factors on the order of $10^{-1}$ dB/m. Trends were comparable with literature data on Nb and NbTi at 4 K, which did have lower loss under these conditions, but suggested similar or perhaps better loss for YBCO when accounting for the temperature difference. We also developed a cryogenic probe for future measurements in a 14 T applied field at 30 mK. This will serve to directly evaluate YBCO's durability in magnetic fields, and we expect significantly improved performance at millikelvin temperatures.

Marinos, Z. [UCLA]↗

Thermocouples in Resistive and Induction Furnaces Operated in Strong Magnetic Fields

The thermomagnetic processing methods require an understanding of the in situ temperatures experienced by the workpieces. When commonly used thermocouples (TCs) are employed in induction furnaces, RF fields can contribute additional temperature uncertainties to the ones arising from the use of strong magnetic fields. Focusing on temperatures between 300 ° C and 1000 ° C produced by induction and resistive furnaces, the readings generated by Type-K TCs were contrasted to the ones produced by Type-S and Type-N sensors for magnetic fields up to 9 T. Overall, when comparing Type-K response to temperatures above 700 ° C in both zero field and high field ( ≤9 T), the differences amounted to less than 1% and when continuously measured has a linear relationship to the strength of the applied field. The relative invariance of Type-N and Type-S TCs was confirmed. In conclusion, these findings suggest that the use of TCs in high magnetic fields remains a viable option for applications, although the precision depends on the type used.

Tener, Zachary P. [Oak Ridge National Laboratory (↗

Magnetic field induced modification of a first-order ferromagnetic transition in Eu 2 ⁢In

Here, we present a comprehensive study of the temperature-and magnetic-field-dependent magnetization, specific heat, and local crystal structure across the first-order ferromagnetic–paramagnetic transition in Eu 2 ⁢In. Anomalies in the magnetocaloric response are observed near 𝐻 ≈ 25 kOe, including changes in field scaling of magnetic entropy, local entropy exponent, and universal master curve, which suggest an apparent weakening of the first-order character of the transition. However, quantitative analysis of the magnetocaloric parameters together with modified Arrott plots demonstrates that the transition remains first order up to at least 70 kOe. Specific-heat measurements reveal a field-induced splitting of the sharp zero-field anomaly into a doublet, providing a natural explanation for the change in the magnetocaloric response. Magnetic-field-dependent extended x-ray absorption fine structure (EXAFS) measurements show no detectable field-induced changes in the local coordination environment of Eu. We therefore attribute these observations to a magnetic-field-induced two-step transition process in Eu 2 ⁢In.

Kumar, Ajay [Ames Laboratory (AMES), Ames, IA (Uni↗

Magnetosynthesis Effect on the Structure and Ground State of Cu 2+ -Based Antiferromagnets

Synthetic variables can have an outsized influence on the crystal structure and magnetic properties of a material, particularly those of quantum materials. In this work, we investigate the impact of synthesis under a magnetic field (magnetosynthesis) on the crystal structure and magnetic properties of several Cu 2+ (S = 1/2)-based materials with antiferromagnetic interactions and varying levels of magnetic frustration, from simple antiferromagnets to a quantum spin liquid. Here, we develop methods to apply small (0.09–0.37 T) magnetic fields during low-temperature hydrothermal, evaporative, and rehydration syntheses of the simple antiferromagnet CuCl 2 ·2H 2 O, the canted antiferromagnet (Cu,Zn) 3 Cl 4 (OH) 2 ·2H 2 O, the frustrated and canted antiferromagnet atacamite Cu 2 (OH) 3 Cl, and the highly frustrated quantum spin liquid herbertsmithite Cu 3 Zn(OH) 6 Cl 2 . We report the first single-crystal X-ray structural determination of the Cu 3 Cl 4 (OH) 2 ·2H 2 O structure type and probe the stability of this phase both experimentally and computationally. Atacamite Cu 2 (OH) 3 Cl synthesized under a 0.19 T field experiences a 0.15 K (∼3%) decrease in its Néel transition temperature. This result suggests that magnetosynthesis with small applied fields may have a very subtle influence upon the magnetic properties of moderately magnetically frustrated 3 d materials.

36 MATERIALS SCIENCE↗