Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tensile Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Tensile tests of niobium material for SRF cavities

Mechanical tests of cavity-grade niobium samples were conducted to provide engineering information for the certification of 3rd-harmonic superconducting radio-frequency cavities and cryomodules. Large changes of mechanical properties occur throughout the cavity fabrication process due to the cold work introduced by forming, the heating introduced by electron beam welding, and the recovery of cold work during the anneal used to degas hydrogen after chemical processing. Data is provided here to show the different properties at various stages of fabrication, including both weld regions and samples from the bulk niobium far away from the weld. Measurements of RRR were used to assure that any contamination during annealing was negligible.

43 PARTICLE ACCELERATORS↗

Dual morphology (fibres and particles) cellulosic filler for WPC materials

Wood-plastic composites (WPC) were fabricated by using a polyethylene (PE) matrix and filling it with wood flour in the amount of 30 wt.%, and compared with the same composites with further amount of 10 wt.% of cellulosic recycled fibres added. The materials were produced by turbomixing and subsequent moulding under pressure. Mechanical properties of both WPC and WPC with cellulosic recycled fibres were evaluated through mechanical and physical-chemical tests. Tensile tests clarified that a moderate reduction is strength is observed with the bare introduction of wood flour with respect to the neat PE matrix, whilst some recovery is offered by the addition of recycled cellulose fibres. Even more promisingly, the elastic modulus of PE matrix is substantially improved by the addition of wood flour (around 8% on average) and much more so with the further addition of recycled cellulose (around 20% on average). The fracture surfaces from the tensile test were analysed by scanning electron microscope (SEM) indicating a reduction in microporosity as an effect of added cellulose. The water absorption test and the hardness measure (Shore D) were also performed. SEM analysis underlined the weak interface between both wood particle and cellulosic recycled fibres and matrix. The water absorption test showed a higher mass variation for pure WPC than WPC with cellulosic recycled fibres. The hardness measurement showed that the presence of cellulosic recycled fibres improves both superficial hardness of the composite and temperature resistance.

36 MATERIALS SCIENCE↗

Environmental control system for cryogenic testing of tensile specimens

Environmental control system uses a special coil to permit the tensile testing of specimens which may be subjected to temperatures anywhere between liquid nitrogen and room temperature. The test specimen zone is surrounded by the coil which permits the selective flooding of the specimen with warm or cold gas.

Vandergrift, E. F.↗

Life Modeling and Design Analysis for Ceramic Matrix Composite Materials

The primary research efforts focused on characterizing and modeling static failure, environmental durability, and creep-rupture behavior of two classes of ceramic matrix composites (CMC), silicon carbide fibers in a silicon carbide matrix (SiC/SiC) and carbon fibers in a silicon carbide matrix (C/SiC). An engineering life prediction model (Probabilistic Residual Strength model) has been developed specifically for CMCs. The model uses residual strength as the damage metric for evaluating remaining life and is posed probabilistically in order to account for the stochastic nature of the material s response. In support of the modeling effort, extensive testing of C/SiC in partial pressures of oxygen has been performed. This includes creep testing, tensile testing, half life and residual tensile strength testing. C/SiC is proposed for airframe and propulsion applications in advanced reusable launch vehicles. Figures 1 and 2 illustrate the models predictive capabilities as well as the manner in which experimental tests are being selected in such a manner as to ensure sufficient data is available to aid in model validation.

Source record↗

(Invited) Effect of Aging on Mechanical Properties of Lithium Ion Cell Components

The mechanical properties of aged and fresh lithium ion cell components are evaluated in this paper. Cells components were obtained from destructive physical analysis of 40Ah NMC/Graphite-based pouch cells before and after cycling and were subjected to mechanical testing. The aging tests comprised of cycling the cell across a voltage window of 4.1V to 3.0V at room temperature (25?). Using a 2C charging rate and 1C discharging rate, the cells were subjected to over 5600 cycles before a 80% drop in the name-plate capacity was observed. Mechanical tests, including compression test, tensile test and indentation test, were conducted on the cell components to investigate differences in the mechanical performance. Comparison of the fresh and aged cells components shows that cycling the cells has different degrees of impact on the different cell components. Anodes suffered the most serious deterioration in mechanical properties while separators remained intact under the test condition investigated.

30 DIRECT ENERGY CONVERSION↗

Effect of the overlapping factor on the microstructure and mechanical properties of pulsed Nd:YAG laser welded Ti6Al4V sheets

The effect of the overlapping factor on the microstructures and mechanical properties of pulsed Nd:YAG laser welded Ti6Al4V alloy sheets was investigated by microstructural observations, microhardness tests, tensile tests and fatigue tests. A microstructural examination shows that by increasing the overlapping factor, the grains in the fusion zone become coarser, and the width of the heat affected zone increases. As overlapping factor increases, the width of region composed completely of martensite α′ and the secondary α phase in the heat affected zone increases, consequently the gradient of microstructure along the direction from the fusion zone to base metal decreases, so does the gradient of microhardness. The results of tensile and fatigue tests reveal that the joints made using medium overlapping factor exhibit better mechanical properties than those welded with low and high overlapping factors. Based on the experimental results, it can be stated that a sound weld of Ti6Al4V alloy can be obtained if an appropriate overlapping factor is used. - Highlights: • The weld quality of Ti6Al4V alloy under various overlapping factors was assessed. • Tensile and fatigue tests were conducted with as-welded specimen. • Localized strain across the weld was measured using DIC photogrammetry system. • A sound weld of Ti6Al4V alloy is obtained by using right overlapping factor.

36 MATERIALS SCIENCE↗

Integrating fiber optic sensors into metallic components for sensing in harsh environments

The integration of fiber optic sensors into high-temperature materials is critical for real-time monitoring and autonomous operation of engineering systems. This study demonstrated a spark plasma sintering (SPS)-assisted embedding process for integrating sapphire fiber optic sensors into stainless steel components during part fabrication. Optical fibers were encapsulated in stainless steel 316L powders which were sintered at different fabrication conditions using SPS to investigate the effects of sintering parameters on the embedment. Measurements of optical transmittance, combined with microstructural analysis (X-ray computed tomography and scanning electron microscopy) and mechanical testing (tensile and microhardness), were conducted to examine the fiber functionality, fiber–matrix bonding quality, and properties of the sintered materials. Here, the results show that under suitable fabrication conditions, intact optical fibers can be encapsulated in highly-densified (>98 % relative density) stainless steel components. These conditions also led to a good bond at the fiber–matrix interface with micron-sized material interdiffusion across the interface. The sintering parameters were observed to affect fiber optical attenuation, where high temperature, pressure, and hold time during SPS enhanced fiber–matrix bonding and adversely affected optical transmission. Tensile testing confirmed the superior tensile strength and ductility of the matrix fabricated by SPS. Furthermore, the materials exhibited limited strength reduction (~70 MPa) upon the integration of fibers. This study demonstrates the effectiveness of SPS for fiber-material integration for high-temperature applications.

36 MATERIALS SCIENCE↗

Development of a Testing Protocol for C7 Carbon Fiber Core Conductors

To avoid the high costs and environmental and regulatory challenges of building new lines to meet the power demand, utilities are searching for ways to increase power transmission capacity on existing lines and thereby. This could involve upgrading the network lines with conductors capable of transmitting greater capacity. In recent years, conductor manufacturers have begun producing new conductors that can operate at higher temperatures without violating present electrical clearances to ground and other objects. One new conductor technology is a carbon composite core with PPS polymer matrix and PEEK capping layer composite conductor, manufactured by Southwire Inc. The conductor uses new materials, which have not previously been used for overhead lines. The project made an initial characterization of the composite core to define the material used in the manufacture of the composite. Several analytical procedures were then conducted to evaluate the physical-chemical impacts on the composite as a result of thermal exposure. These procedures included thermogravimetry, dynamic mechanical analysis, thermal mechanical analyses, and optical microscopy. Mechanical three-point flexural tests, tensile tests, creep tests, and dynamic vibration tests were then performed to estimate the potential degradation after thermal aging. The report provides the basis to develop a qualification testing protocol for the carbon composite core at targeted service environments. The work covers the design of the qualification testing protocol and the follow-on validation testing to support the proposed methods. The research includes the following approaches: initial characterization, performance of thermal aging, characterization of the aged material, comparison of aged properties or characteristics to the original, and concluding by the findings through the developed qualification procedures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic capability of the filter reduced the efficiency of challenging particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic charge of the filter was correlated with a reduction in capturing particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test and reduction in aerosol filtering efficiency. Key Words: N95 respirators, respirators, airborne transmission, pandemic prevention, COVID-19, gamma sterilization

COVID-19↗

High-Entropy Alloy R&D for Accelerator Beam Window Applications

High-Entropy Alloys are a class of novel material that can offer improved resistance to beam-induced radiation damage and thermal shock. Development of these new alloys to serve as beam windows in multi-megawatt accelerator target applications is ongoing at Fermilab. Currently we are investigating AlCoCrMnTiV alloy systems of 4-6 components for service as beam windows; these compositions are predicted by CALPHAD simulation to have a low density and single-phase BCC crystal structure. The microstructures of these systems are being studied by electron microscopy techniques such as energy dispersive X-ray spectroscopy (EDS) to determine elemental homogeneity and composition, electron backscatter diffraction (EBSD) to quantify grain structure and orientation, and transmission electron microscopy (TEM) to observe defect structures and precipitate formation; nanoindentation is used to probe microstructural mechanical properties. Initial bulk property characterization utilizes differential scanning calorimetry to quantify specific heat capacity (cp), dilatometry to determine the coefficient of thermal expansion (CTE), and time-domain thermoreflectance (TDTR) to measure thermal conductivity (K). A miniature tensile testing apparatus is also being developed to test tensile properties. Post-irradiation examination is currently ongoing for several of these compositions that have been irradiated by low-energy ions to damage levels and at a temperature relevant to beam window applications at future next-generation accelerator facilities. This talk will briefly describe the alloy design and synthesis before going into more depth covering microstructural pre-characterization, and post-irradiation examination results from low-energy ion irradiated specimens. This will be followed by the plans for alloy down selection and future prototypic proton irradiations.

43 PARTICLE ACCELERATORS↗

Corrosion Embrittlement of Duralumin II Accelerated Corrosion Tests and the Behavior of High-Strength Aluminum Alloys of Different Compositions

The permanence, with respect to corrosion, of light aluminum alloy sheets of the duralumin type, that is, heat-treatable alloys containing Cu, Mg, Mn, and Si is discussed. Alloys of this type are subject to surface corrosion and corrosion of the interior by intercrystalline paths. Results are given of accelerated corrosion tests, tensile tests, the effect on corrosion of various alloying elements and heat treatments, electrical resistance measurements, and X-ray examinations.

Rawdon, Henry S↗

Fuel cladding post-quench LOCA embrittlement: mechanical test relevance

During a loss-of-coolant-accident (LOCA), the fuel cladding is submitted to a high temperature increase in a steam environment, along with an internal pressure increase which would eventually lead to ballooning and burst of the cladding. Steam could then penetrate through the burst opening and lead to inner surface oxidation and secondary-hydriding of the cladding. Post-quench cladding rupture can then occur either in two-sided oxidized area with wall thinning due to ballooning, or in single-sided oxidized area with large hydrogen content. Common tests involved in the evaluation of the post-quench ductility are Ring Compression Tests (RCT), Expansion Due to Compression Test (EDC) or Axial Tensile Tests (AT). Questions arise about these mechanical tests, as for instance, the influence on sample failure of the oxide layer thickness partitioning between inner and outer diameter. A systematic study was carried out to compare several mechanical tests on both single-sided and two-sided Zircaloy-4 oxidized samples. Five different mechanical tests were compared, including RCT: C-shaped ring Compression Test (CCT), Axial Tensile test (AT), Ring Tensile Test with well-defined machined gage section (RTT) and plain Ring Tensile Test (pRTT). All samples were taken from cladding tubes which had been oxidized in steam at 1200 Celsius degrees and then water-quenched. Mechanical tests were performed at room temperature and two to three samples were tested for each oxidation conditions and for every sample geometry to assess the reproducibility. Metallographic examinations were carried out to measure the ZrO{sub 2} and αZr(O) layer thicknesses and the ex-β/α(O) phase fraction. Mean hydrogen content measurements were also performed systematically on each sample. Results indicate that the different mechanical tests have not the same sensitivity to the oxide layer partitioning: RTT and pRTT load at failure seems to depend mainly on the cumulated oxide layer thickness rather than on its partitioning, whereas this parameter has an impact on CCT and AT test results. For all tensile tests, stresses at failure were derived from load-displacement curves. The failure of brittle samples was assumed to be governed by linear elastic fracture mechanics. Using conventional stress intensity factor solution, a value of the material fracture toughness controlling the sample failure was determined from experimental results and discussed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cryogenic properties of dispersion strengthened copper for high magnetic fields

Cold deformed copper matrix composite conductors, developed for use in the 100 tesla multi-shot pulsed magnet at the National High Magnetic Field Laboratory (NHMFL), have been characterized. The conductors are alumina strengthened copper which is fabricated by cold drawing that introduces high dislocation densities and high internal stresses. Both alumina particles and high density of dislocations provide us with high tensile strength and fatigue endurance. The conductors also have high electrical conductivities because alumina has limited solubility in Cu and dislocations have little scattering effect on conduction electrons. Such a combination of high strength and high conductivity makes it an excellent candidate over other resistive magnet materials. Thus, characterization is carried out by tensile testing and fully reversible fatigue testing. In tensile tests, the material exceeds the design criteria parameters. In the fatigue tests, both the load and displacement were measured and used to control the amplitude of the tests to simulate the various loading conditions in the pulsed magnet which is operated at 77 K in a non-destructive mode. In order to properly simulate the pulsed magnet operation, strain-controlled tests were more suitable than load controlled tests. For the dispersion strengthened coppers, the strengthening mechanism of the aluminum oxide provided better tensile and fatigue properties over convention copper.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fracture Test Results for 0.5, 0.7 and 0.9 Inch Thick 2324-T39 Aluminum Alloy Material

A summary of experimental data is presented for a series of fracture tests and tensile tests that were conducted on a 2324-T39 aluminum alloy material. Static tensile tests were performed to determine the stress-strain response for the material. For the fracture tests three thicknesses (B = 0.5, 0.7, and 0.9-inches) and two specimen types (middle crack tension and compact tension specimens) were used. The middle crack tension specimens were 12-inches wide, and the compact tension specimens were 2, 4, and 6-inches wide. The fracture tests were conducted in the L-T orientation (crack perpendicular to the rolling direction and load parallel to the rolling direction).

Johnston, William M.↗