Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Projection Chamber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Fission Fragment Angular Distributions measured with a Time Projection Chamber

The subject is presented in a series of slides with the following organization: Introduction (What is anisotropy? Relevance (Theory and ratio cross section), Previous measurements); Experiment (Particle tracking in the fissionTPC, Neutron time of flight, Data analysis & uncertainty calculation, Preliminary result for 235 U); and Future Work (Refine 235 U result, Process 239 Pu data).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-Projection Chamber Development for the Multi-Purpose Detector in the NICA Project

Within the framework of the scientific program for the study of hot and dense nuclear matter in the Veksler and Baldin Laboratory of High Energy Physics of the Joint Institute of Nuclear Research, Dubna (JINR), the NICA megaproject (Nuclotron-based Ion Collider fAcility) based on the Nuclotron-M accelerator is implemented. The new accelerator facility will make it possible to research the properties of dense baryonic matter in the collision of heavy ions in a wide range of atomic masses from p – p collisions in the energy range √ S{sub pp} = 12–27 GeV/ n and d + d collisions with energies of √ S{sub NN} = 4–13.8 GeV/n with the average luminosity L = 10{sup 32} cm{sup –2} s{sup –1} up to Au{sup +79} + Au{sup +79} collisions in the energy range √S{sub NN} = 4–11 GeV/n with the average luminosity L = 10{sup 27} cm{sup –2} s{sup –1} (Au{sup +79}). A collider provides two points of intersection of beams, in one of which the multipurpose detector (Multi-Purpose Detector, MPD) will be installed. The time-projection gas chamber (TPC) is the main tracking detector and the particle identifier of the Multi-Purpose Detector. The article considers the structure of the MPD, the design and the main working parameters of TPC and its subsystems. The front-end electronics (FEE), as well as the procedure for assembling and integrating the TPC into the MPD are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

3D track reconstruction of low-energy electrons in the MIGDAL low pressure optical time projection chamber

Here, we demonstrate three-dimensional track reconstruction of electrons in a low pressure (50 Torr) optical TPC consisting of two glass GEMs with an ITO strip readout in CF 4 and CF 4 /Ar mixtures. The reconstructed tracks show a variety of event topologies, including short tracks from photoelectrons induced by 55 Fe 5.9 keV X-rays and long tracks from gamma ray interactions and beta decays. Algorithms for event identification and track ridge detection are discussed as well as multiple methods for integrating information from the camera image and ITO waveforms with the goal of full 3D reconstruction of the track.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation and performance of a dual-phase crystalline/vapor xenon time projection chamber

We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to exclude, or tag and reject radon-chain backgrounds. As a preamble to demonstrating such capabilities, the present article makes a first demonstration of the operation of a crystalline/vapor xenon TPC with electroluminescence (gas gain) for the electron signal readout. It also shows that the scintillation yield in crystalline xenon appears to be identical to that in liquid xenon, in contrast to previous results.

47 OTHER INSTRUMENTATION↗

Cold Electronics for Giant Liquid Argon Time Projection Chambers

The choice between cold and warm electronics (inside or outside the cryostat) in very large LAr TPCs (>5-10 ktons) is not an electronics issue, but it is rather a major cryostat design issue. This is because the location of the signal processing electronics has a direct and far reaching effect on the cryostat design, an indirect effect on the TPC electrode design (sense wire spacing, wire length and drift distance), and a significant effect on the TPC performance. All these factors weigh so overwhelmingly in favor of the cold electronics that it remains an optimal solution for very large TPCs. In this paper signal and noise considerations are summarized, the concept of the readout chain is described, and the guidelines for design of CMOS circuits for operation in liquid argon (at {approx}89 K) are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Operation of A Setup with A Camera and Adjustable Mirror to Inspect the Sense-Wire Planes of the Time Projection Chamber Inside the MicroBooNE Cryostat

Detectors in particle physics, particularly when including cryogenic components, are often enclosed in vessels that do not provide any physical or visual access to the detectors themselves after installation. However, it can be desirable for experiments to visually investigate the inside of the vessel. The MicroBooNE cryostat hosts a TPC with sense-wire planes, which had to be inspected for damage such as breakage or sagging. This inspection was performed after the transportation of the vessel with the enclosed detector to its final location, but before filling with liquid argon. Our paper describes an approach to view the inside of the MicroBooNE cryostat with a setup of a camera and a mirror through one of its cryogenic service nozzles. The paper also describes the camera and mirror chosen for the operation, the illumination, and the mechanical structure of the setup. It explains how the system was operated and demonstrates its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar Neutrino Detection with a Pixelated Liquid-Argon Time Projection Chamber

This thesis presents a study of low-energy solar neutrino detection using large-scale LArTPCs, focussing on novel pixelated readout technologies. Solar neutrinos offer a unique probe of fundamental neutrino properties and solar physics, but their detection in the MeV range is challenged by backgrounds. We investigate two complementary technologies: SoLAr, which integrates LArPix-based pixelated charge collection with Silicon Photomultipliers (SiPMs) in a hybrid anode design for simultaneous charge and light detection; and Q-Pix, a triggerless pixelated readout architecture based on charge integrate-reset circuits with local clocks, where Reset Time Differences encode ionisation waveforms via time-to-charge conversion. Two SoLAr prototypes were developed and operated, demonstrating VUV-sensitive SiPM performance in liquid argon and accurate charge-light signal matching with a charge detection threshold of $\sim 100 \mathrm{keV}$. We also implement a complete simulation and reconstruction framework, incorporating realistic detector geometry, electron transport, readout response, and detailed signal and background models, including intrinsic argon and radon progeny, as well as site-specific $\gamma$-ray and neutron fluxes. For Q-Pix, we demonstrate that with a pixel size of $4\times 4$ mm$^2$ and a reset threshold of 1 fC ($\sim 0.1475$ MeV), full-scale operation produces data volumes below 1 PB per 10 ktonne-year. For SoLAr, assuming a shielded DUNE-like detector and 100 ktonne-year exposure, we project uncertainties of $0.90\times 10^{-5}$ eV$^2$ on $\Delta m^2_{21}$ and 0.033 on $\sin^2\theta_{12}$, improving to $0.46\times 10^{-5}$ eV$^2$ and 0.025 with 400 kilotonne-year. At this higher exposure, we also obtain a day–night flux asymmetry at the level of $( -5.6 \pm 3.6 ) \%$. Combining Monte Carlo modelling, hardware validation, and advanced reconstruction techniques, this work establishes a path toward next-generation ktonne-scale LArTPCs as observatories for precision solar neutrino physics.

Ruiz Ferreira, Guilherme [Manchester U.] (ORCID:00↗

The Data Analysis Framework for the NIFFTE Fission Time Projection Chamber

The goal of the Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) is to measure the neu- tron induced fission cross sections for 235,238U and 239Pu to an unprecedented accuracy of 0.5% or better. Cur- rently, the best known fission cross sections are for 235U and have uncertainties of 1 - 3%. For 239Pu, at some energies the uncertainty is as large as 20% [1]. These uncertainties in the cross section can propagate into fis- sion reactor performance parameter calculations such as: criticality, peak power, temperature reactivity, transmu- tation potential, radiotoxicity and decay heat in a respos- itory.

Stave, Sean C.↗

HydroX, a light dark matter search with hydrogen-doped liquid xenon time projection chambers

Experimental efforts searching for dark matter particles over the last few decades have ruled out many candidates led by the new generation of tonne-scale liquid xenon. For light dark matter, hydrogen could be a better target than xenon as it would offer a better kinematic match to the low mass particles. This article describes the HydroX concept, an idea to expand the dark matter sensitivity reach of large liquid xenon detectors by adding hydrogen to the liquid xenon. We discuss the nature of signal generation in liquid xenon to argue that the signal produced at the interaction site by a dark matter–hydrogen interaction could be significantly enhanced over the same interaction on xenon, increasing the sensitivity to the lightest particles. We discuss the technical implications of adding hydrogen to a xenon detector, as well as some background considerations. Finally, we make projections as to the potential sensitivity of a HydroX implementation and discuss next steps.

Experimental particle physics↗

Large low background kTon-scale liquid argon time projection chambers

Here we find that it is possible to increase sensitivity to low energy physics in a third or fourth Deep Underground Neutrino Experiment (DUNE)-like module with careful controls over radiopurity and targeted modifications to a detector similar to the DUNE Far Detector design. In particular, sensitivity to supernova and solar neutrinos can be enhanced with improved MeV-scale reach. A neutrinoless double beta decay search with 136 Xe loading appears feasible. Furthermore, sensitivity to Weakly-Interacting Massive Particle (WIMP) Dark Matter becomes competitive with the planned world program in such a detector, offering a unique seasonal variation detection that is characteristic of the nature of WIMPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 4 tonne demonstrator for large-scale dual-phase liquid argon time projection chambers

A 10 kilo-tonne dual-phase liquid argon TPC is one of the detector options considered for the Deep Underground Neutrino Experiment (DUNE). The detector technology relies on amplification of the ionisation charge in ultra-pure argon vapour and offers several advantages compared to the traditional single-phase liquid argon TPCs. A 4.2 tonne dual-phase liquid argon TPC prototype, the largest of its kind, with an active volume of \three has been constructed and operated at CERN. In this paper we describe in detail the experimental setup and detector components as well as report on the operation experience. We also present the first results on the achieved charge amplification, prompt scintillation and electroluminescence detection, and purity of the liquid argon from analyses of a collected sample of cosmic ray muons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗