Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time at Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Thermal control of low-pressure fractionation processes

Thermal models detailing the solidification paths for shallow basaltic magma chambers (both open and closed systems) were calculated using finite-difference techniques. The total solidification time for closed chambers are comparable to previously published calculations; however, the temperature-time paths are not. These paths are dependent on the phase relations and the crystallinity of the system, because both affect the manner in which the latent heat of crystallization is distributed. In open systems, where a chamber would be periodically replenished with additional parental liquid, calculations indicate that the possibility is strong that a steady-state temperature interval is achieved near a major phase boundary. In these cases it is straightforward to analyze fractionation models of the basaltic liquid evolution and their corresponding cumulate sequences. This steady thermal fractionating state can be invoked to explain large amounts of erupted basalts of similar composition over long time periods from the same volcanic center and some rhythmically layered basic cumulate sequences.

Usselman, T. M.↗

High-Temperature Thermometer Using Cr-Doped GdAlO3 Broadband Luminescence

A new concept has been developed for a high-temperature luminescence-based optical thermometer that both shows the desired temperature sensitivity in the upper temperature range of present state-of-the-art luminescence thermometers (above 1,300 C), while maintaining substantial stronger luminescence signal intensity that will allow these optical thermometers to operate in the presence of the high thermal background radiation typical of industrial applications. This objective is attained by using a Cr-doped GdAlO3 (Cr:GdAlO3) sensor with an orthorhombic perovskite structure, resulting in broadband luminescence that remains strong at high temperature due to the favorable electron energy level spacing of Cr:GdAlO3. The Cr:GdAlO3 temperature (and pressure) sensor can be incorporated into, or applied onto, a component s surface when a non-contact surface temperature measurement is desired, or alternatively, the temperature sensor can be attached to the end of a fiber-optic probe that can then be positioned at the location where the temperature measurement is desired. In the case of the fiber-optic probe, both the pulsed excitation and the luminescence emission travel through the fiber-optic light guide. In either case, a pulsed light source provides excitation of the luminescence, and the broadband luminescence emission is collected. Real-time temperature measurements are obtain ed using a least-squares fitting algorithm that determines the luminescence decay time, which has a known temperature dependence established by calibration. Due to the broad absorption and emission bands for Cr:GdAlO3, there is considerable flexibility in the choice of excitation wavelength and emission wavelength detection bands. The strategic choice of the GdAlO3 host is based on its high crystal field, phase stability, and distorted symmetry at the Cr3+ occupation sites. The use of the broadband emission for temperature sensing at high temperatures is a key feature of the invention and is novel since broadband luminescence emission normally shows severe thermal quenching. The tightly bound AlO6 octahedra in GdAlO3 results in a larger energy barrier to nonradiative decays than in other materials and therefore makes using broadband emission for temperature sensing possible at high temperatures. This approach results in a substantial increase in temperature capability. For example, the most commonly used Cr-doped crystal used for luminescence-based temperature measurements, ruby, has only been demonstrated up to 600 C, whereas the Cr:GdAlO3 optical thermometer under development has already been shown to exhibit useful luminescence up to 1,300 C. Because GdAlO3 is non-reactive and is stable in harsh, high-temperature environments, sensors composed of Cr:GdAlO3 will be very well suited for remote high-temperature measurements in engine or industrial environments where its intense high-temperature luminescence will stand out above significant thermal radiation background levels.

Eldridge, Jeffrey↗

Leveraging Extremal Dependence to Better Characterize the 2021 Pacific Northwest Heatwave

Abstract In late June, 2021, a devastating heatwave affected the US Pacific Northwest and western Canada, breaking numerous all-time temperature records by large margins and directly causing hundreds of fatalities. The observed 2021 daily maximum temperature across much of the U.S. Pacific Northwest exceeded upper bound estimates obtained from single-station temperature records even after accounting for anthropogenic climate change, meaning that the event could not have been predicted under standard univariate extreme value analysis assumptions. In this work, we utilize a flexible spatial extremes model that considers all stations across the Pacific Northwest domain and accounts for the fact that many stations simultaneously experience extreme temperatures. Our analysis incorporates the effects of anthropogenic forcing and natural climate variability in order to better characterize time-varying changes in the distribution of daily temperature extremes. We show that greenhouse gas forcing, drought conditions and large-scale atmospheric modes of variability all have significant impact on summertime maximum temperatures in this region. Our model represents a significant improvement over corresponding single-station analysis, and our posterior medians of the upper bounds are able to anticipate more than 96% of the observed 2021 high station temperatures after properly accounting for extremal dependence. Supplementary materials accompanying this paper appear online.

Zhang, Likun (ORCID:0000000154584556)↗

A hybrid electronically scanned pressure module for cryogenic environments

Pressure is one of the most important parameters measured when testing models in wind tunnels. For models tested in the cryogenic environment of the National Transonic Facility at NASA Langley Research Center, the technique of utilizing commercially available multichannel pressure modules inside the models is difficult due to the small internal volume of the models and the requirement of keeping the pressure transducer modules within an acceptable temperature range well above the -173 degrees C tunnel temperature. A prototype multichannel pressure transducer module has been designed and fabricated with stable, repeatable sensors and materials optimized for reliable performance in the cryogenic environment. The module has 16 single crystal silicon piezoresistive pressure sensors electrostatically bonded to a metalized Pyrex substrate for sensing the wind tunnel model pressures. An integral temperature sensor mounted on each silicon micromachined pressure sensor senses real-time temperature fluctuations to within 0.1 degrees C to correct for thermally induced non-random sensor drift. The data presented here are from a prototype sensor module tested in the 0.3 M cryogenic tunnel and thermal equilibrium conditions in an environmental chamber which approximates the thermal environment (-173 degrees C to +60 degrees C) of the National Transonic Facility.

Chapman, J. J.↗

A Technique for Transient Thermal Testing of Thick Structures

A new open-loop heat flux control technique has been developed to conduct transient thermal testing of thick, thermally-conductive aerospace structures. This technique uses calibration of the radiant heater system power level as a function of heat flux, predicted aerodynamic heat flux, and the properties of an instrumented test article. An iterative process was used to generate open-loop heater power profiles prior to each transient thermal test. Differences between the measured and predicted surface temperatures were used to refine the heater power level command profiles through the iteration process. This iteration process has reduced the effects of environmental and test system design factors, which are normally compensated for by closed-loop temperature control, to acceptable levels. The final revised heater power profiles resulted in measured temperature time histories which deviated less than 25 F from the predicted surface temperatures.

Horn, Thomas J.↗

Oxidation-resistant silicide coating applied to columbium alloy screen

Coated screens withstand temperature cycling in special transpiration-cooling systems and provide porous surface that is effective at temperatures well above those limiting superalloy screen efficiency. Thickness of coating depends on time, temperature and activator concentration. Coatings are uniform and resistant to thermal cycling.

Torgerson, R. T.↗

Thermal expansion behavior of LDEF metal matrix composites

The effects of the space environment on the thermal expansion stability of metal matrix composites (graphite/Al and graphite/Mg) will be presented. A sample from each category of metal matrix composites mounted on the leading and trailing edge was chosen for analysis of the temperature-time-thermal strain histories. Typical thermal expansion curves over the same range of temperature were selected at the beginning, mid, and end of the recording duration. The thermal expansion of selected post-flight LDEF samples were measured over the same range of temperature in the laboratory using a Michelson laser interferometer. The thermal strains were monitored concurrently with a laser interferometer and a mounted strain gage.

Le, T. D.↗

Characterization of Effluents Given Off by Wiring Insulation

When an insulated wire is heated, the insulation emits a variety of effluents. This paper discusses the basis of emissions of effluents from wiring insulation. Several species are emitted at relatively low temperatures, while others are emitted when the wire reaches higher temperatures. We isolate the emissions by relative molecular weight of the effluents and measure the effluent concentration both as a function of time (temperature held constant) and by wire temperature. We find that the Law of Mass Action describes and predicts the time-dependence of the emission of a specific effluent caused by the heating. The binding energy is determined by performing an Arrhenius Plot on the temperature data. These dependencies are discussed and working equations are derived. Data collected from 20 gauge wire (MIL-W-22759/11-20) is used to illustrate and confirm the validity of the theory.

Yost, William T.↗

Aircraft Cargo Compartment Fire Test Simulation Program

The objective of the test was to assess fire containment and fire extinguishment in the cargo by reducing the ventilation through the cargo compartment. Parameters which were measured included ignition time, burnthrough time, and physical damage to the cargo liner, composition of selected combustible gases, temperature-time histories, heat flux, and detector response. The ignitor load was made of a typical cargo consisting of filled cardboard cartons occupying 50% of the compartment volume.

Blumke, R. E.↗

Thermodynamic and Diffusion Model Estimates on Metamorphic Temperatures and Timescales for Basaltic Eucrite GRA 98098

Introduction: HED meteorites are thought to rep-resent igneous rocks from Vesta’s basaltic crust and preserve evidence of early crustal metamorphism. Determining the temperatures and timescales of thermal metamorphism is important for reconstructing crustal evolution in the early solar system. Here, we study basaltic eucrite Graves Nunataks (GRA) 98098, which has been identified as a highly metamorphosed eucrite [1]. We present new estimates on metamorphic temperatures determined via thermodynamic modeling as well as the initial results from diffusion models constraining timescales of thermal metamorphism. Sample Description: GRA 98098 is an unbrecciated eucrite with a granoblastic plagioclase and pyroxene mineralogy. Millimeter to cm-long lathes of tridymite cross-cut and poikilitically enclose plagioclase and pyroxene [1,this work]. Pyroxene grains have exsolved into Ca-rich (~Wo38En29Fs33) and Ca-poor (~Wo4.5En36Fs59.5) lamellae. Both unzoned and zoned plagioclase grains are observed. Unzoned plagioclase grains are found solely with tridymite laths. These grains have ~An92 compositions. The cores of the zoned plagioclase grains have the same composition and thin, relatively sodic rims (~An67), (Fig. 1). The bulk sample is unusually enriched in highly in-compatible elements and has one of the most fractionated REE patterns reported [1]. Maximum metamorphic temperatures of 985±78°C have been estimated using two-pyroxene thermometry [2]. Methods: Thermodynamic modeling. Thermodynamic models were constructed using the software Perple_X, which employs a Gibbs free energy minimization in order to determine the most stable phase assemblage for a given bulk rock composition [3]. Bulk composition was calculated using mineral com-positions acquired via EMPA (this study) and the observed abundancies present in the thin section. Two bulk compositions were estimated; 1) includes all phases present in the thin section, (assumes that all phases are present during metamorphism), 2) excludes tridymite from the bulk calculation (assumes that tridymite was not present during metamorphism). In order to determine whether metamorphic equilibria was achieved and estimate temperatures of metamorphism, we compared measured pyroxene compositions with thermodynamically predicted compositions [4, Fig. 2]. Diffusion Modeling. Several time-temperature de-pendent diffusion profiles were calculated in order to determine the best match for XAn chemical profiles observed at the edges of the zoned plagioclase (Fig. 3). We assumed that the start condition was a stepwise gradient at the plagioclase/pyroxene interface. We also assumed an average diffusion coefficient (D) and a constant temperature using the equation in [5]. D was determined for two temperatures (T = 1060ºC; near eucrite solidus [6] and T = 985ºC; metamorphism reported in [4]) and then XAn was calculated as a function of distance from plagioclase core to rim using an error function solution to Fick’s second law. Results: Thermodynamic model results are summarized in Fig. 2. For a bulk composition that includes all phases in the thin section, pyroxene endmember compositions plot in the following temperature ranges: Fs ~660-860ºC, En~1000ºC & 1150ºC, and Wo~760-900ºC (Fig. 2a). For a bulk composition that excludes tridymite from the peak metamorphic assemblage (i.e., the bulk composition minus the contribution from tridymite), a temperature range could not be determined for the Fs component of pyroxene. For Wo, T~760-900ºC and En, T~1000ºC & 1150ºC (Fig. 2b). Fig. 3 summarizes the diffusion model results. For T = 1060°C & 985°C, the most appropriate time interval was estimated based on which diffusion curve most matched (solid lines, Fig. 3) the EMPA data. For T = 1060°C, the best looking match was t = 500 ka. For T = 985°C, the best match was t = 7 Ma. Discussion and future work: Temperature estimates from thermodynamic models are not conclusive because the temperature ranges determined for pyroxene endmember stability do not overlap (colored fields in Fig. 2), thus implying that there is disequilibrium between pyroxene crystals and the bulk composition considered [4]. Thus, additional exploration is needed to define a metamorphically equilibrated do-main that accurately records peak temperature. The utility of defining metamorphically equilibrated do-mains to improve the accuracy and level of detail elucidated regarding the petrogenetic history of metamorphose samples has been demonstrated previously [4,7]. We suggest that in the case of Fig. 2a, the thin section composition is not representative of the length scales over which metamorphic equilibrium was achieve and in the case of Fig. 2b, the assumption that tridymite was not present during metamorphism was incorrect. However, results from thermodynamic models can provide insight into the relative timing of mineral and compositional textures. For example from texture alone, it is unclear whether tridymite was igneous in origin and represents the last bits of melt in a crystallizing magma chamber, or if it formed during (and possibly initiated) open system thermal metamorphism. The latter could be consistent with a partial melt hypothesis [8,9] while the former implies that simple fractional crystallization can yield the textures present in GRA 98098. The lack of coincidence be-tween pyroxene endmember compositions in Fig. 2b suggest that the bulk composition minus tridymite was not the assemblage in equilibrium with the pyroxene, suggesting that tridymite was present during metamorphism and formed during igneous crystallization. We conclude that the development of the Na-rich plagioclase rims likely occurred during or immediately after peak thermal metamorphism, because eucrites of similar metamorphic grade and texture have unzoned plagioclase (~An92) [2,4,8], and Na zoning is only observed in the plagioclase not included in the tridymite. This suggests that the zoning formed after tridymite formation, and therefore after igneous crystallization. Thus, the timescales calculated via diffusion modeling possibly represent the time interval over which thermal metamorphism occurred. Cooling rates approximated for the Vestan crust predict that the crust cooled below 300°C around 35-40 Ma after formation[10]. This is consistent with our modeling results that predict formation of the Na rich plagioclase rims occurring at higher temperatures over a period of 0.5 to 7 Ma years. Future work. Additional thermodynamic modeling work will focus on selecting an equilibrated bulk rock domain in which to elucidate metamorphic conditions. Diffusion models currently provide a minimum time-scale, since diffusion slows down as the system cools. Future work with will focus on integrating cooling into the diffusion models and constraining the depth at which thermal metamorphism occurs because it could be used to determine whether the range of time-scales calculated for thermal metamorphism are consistent with the geologic environment.

J S Gorce↗

Thermal Characterization and Exhumation of Northwest San Juan Basin Area, NM

The San Juan Basin (SJB), located in southwestern Colorado northwestern New Mexico, containing Paleozoic through middle Cenozoic strata, formed as a partitioned basin approximately 80 Ma in response to the Laramide orogeny. The SJB is a commercially mature, petroleum-producing basin, and currently being explored for CCUS and geothermal resources. Modern heat flow within the SJB is spatially variable with higher geothermal gradients in its northern and eastern portions. The temporal history of the basin thermal history is essential for understanding capacity for carbon storage and geothermal exploration. We present thermochronometric analyses of two surface and two subsurface samples to constrain spatial-temporal thermal evolution of the northwestern San Juan Basin. Apatite (U-Th)/He thermochronometric analyses were conducted on Cliff House and Kirtland Formation outcrops and subsurface samples of the Ojo Alamo and Pictured Cliffs Formations from a DOE funded, CCUS project pilot-well. In addition, vitrinite reflectance data and 1D basin modelling constrain possible time-temperature pathways of the samples in an area where no previous studies have constrained the uplift/exhumation of the Hogback Monocline using thermochronometry. Modeling suggests that elevated subsurface temperatures developed simultaneously with regional late Oligiocene volcanism in the San Juan Volcanic field and timing of maximum burial in the SJB. Late Miocene to Pliocene cooling/exhumation through the apatite (U-Th)/He partial retention zone support stratigraphic evidence of the Colorado Plateau uplift, possibly regional epeirogenic uplift driven by mantle processes.

02 PETROLEUM↗

Viscoelastic behavior and lifetime (durability) predictions

A method for lifetime or durability predictions for laminated fiber reinforced plastics is given. The procedure is similar to but not the same as the well known time-temperature-superposition principle for polymers. The method is better described as an analytical adaptation of time-stress-super-position methods. The analytical constitutive modeling is based upon a nonlinear viscoelastic constitutive model developed by Schapery. Time dependent failure models are discussed and are related to the constitutive models. Finally, results of an incremental lamination analysis using the constitutive and failure model are compared to experimental results. Favorable results between theory and predictions are presented using data from creep tests of about two months duration.

Brinson, R. F.↗

TEMPUS: First results

The electromagnetic levitation facility, TEMPUS, developed by Dornier is designed to operate under microgravity conditions. Compared to terrestrial levitation, microgravity offers the possibility to melt and undercool in ultra high vacuum, thereby, providing an ultra clean environment. The technical concept of the TEMPUS facility was tested on two KC 135 flights and in the Texus 22 mission. Preparative investigations concerning the coil system and the heating and positioning efficiencies were carried out in the TEMPUS laboratory version. Furthermore, temperature-time profiles were determined under various boundary conditions. As a consequence of processing liquid metals under UHV, correct temperature measurement arises as the most critical problem. Experiences with experiments in the TEMPUS laboratory module show that due to the evaporation losses of the sample, the transmission of the CaF2 shielding windows changes drastically during the processing time. The investigation of the effect of contamination on pyrometry and the development of alternative evaporation shielding methods were initiated. During the second KC 135 flight, it was possible to heat up and melt an FeNi sample under He atmosphere. Oscillations of the molten sample, which were excited by switching out the magnetic heating field, could be detected and afterwards analyzed. From the frequency of these oscillations the surface tension of the sample material could be derived. The measurement of the surface tension and viscosity of an undercooled metal is proposed for TEMPUS on IML-2. This document is presented in view graph form.

Neuhaus, P.↗

Tensile Creep and Fatigue of Sylramic-iBN Melt-Infiltrated SiC Matrix Composites: Retained Properties, Damage Development, and Failure Mechanisms

An understanding of the elevated temperature tensile creep, fatigue, rupture, and retained properties of ceramic matrix composites (CMC) envisioned for use in gas turbine engine applications are essential for component design and life-prediction. In order to quantify the effect of stress, time, temperature, and oxidation for a state-of-the-art composite system, a wide variety of tensile creep, dwell fatigue, and cyclic fatigue experiments were performed in air at 1204 C for the SiC/SiC CMC system consisting of Sylramic-iBN SiC fibers, BN fiber interphase coating, and slurry-cast melt-infiltrated (MI) SiC-based matrix. Tests were either taken to failure or interrupted. Interrupted tests were then mechanically tested at room temperature to determine the residual properties. The retained properties of most of the composites subjected to tensile creep or fatigue were usually within 20% of the as-produced strength and 10% of the as-produced elastic modulus. It was observed that during creep, residual stresses in the composite are altered to some extent which results in an increased compressive stress in the matrix upon cooling and a subsequent increased stress required to form matrix cracks. Microscopy of polished sections and the fracture surfaces of specimens which failed during stressed-oxidation or after the room-temperature retained property test was performed on some of the specimens in order to quantify the nature and extent of damage accumulation that occurred during the test. It was discovered that the distribution of stress-dependent matrix cracking at 1204 C was similar to the as-produced composites at room temperature; however, matrix crack growth occurred over time and typically did not appear to propagate through thickness except at final failure crack. Failure of the composites was due to either oxidation-induced unbridged crack growth, which dominated the higher stress regime (> 179 MPa) or controlled by degradation of the fibers, probably caused by intrinsic creep-induced flaw growth of the fibers or internal attack of the fibers via Si diffusion through the CVI SiC and/or microcracks at the lower stress regime (< 165 MPa).

Morscher, Greg↗

SiC/SiC Life Modeling at Intermediate Temperatures under NASA UEET

Within the NASA UEET program, physics-based residual strength and rupture life models are being developed for a variety of time-temperature-stress-environment conditions for SiC/SiC components such as combustor liners and vanes. During service, a tensile stress condition that could be life-limiting typically occurs on the 'cold side' of these components due to thermal gradients and attachment schemes. An intermediate temperature (600 to 1000 C) stress-rupture model has been developed based on the underlying physical processes, i.e., oxygen penetration through matrix cracks, oxidation of the BN interphase, and subsequent fiber-fiber fusion within crack-bridging tows that eventually fail in time due to time-dependent strength degradation of the weakest fibers. Modifications to the model will be discussed to incorporate different environmental conditions as well as changes in oxidation kinetics due to improved interphase concepts.

Morscher, Gregory N.↗

Effect of silicone oil on solid propellant combustion in small motors

The feasibility of reducing troublesome nozzle blockage (by condensation deposits) in laboratory-scale solid rockets by addition of a silicone oil as a propellant ingredient was explored experimentally. An aluminized composite propellant and its counterpart with 1% silicone oil replacing part of the binder were fired in a 63.5 mm diameter, end-burning, all-metal burner. Pressure-time histories were recorded for all of the tests by a Taber gauge mounted at the downstream end of the chamber; temperature-time data at the nozzle throat were obtained in some of the runs by thermocouples having junctions positioned at the wall but insulated from the metal. Deposition of condensables on the nozzle walls causing a progressive increase in the chamber pressure with time was noted. The fraction of firings exhibiting practically no condensation was 59% with silicone and 32% without. On the average, temperature readings at the nozzle throat were higher with the silicone propellants. Although various phenomena may contribute to these findings, the results are not understood completely.

Ramohalli, K.↗