Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time-resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Electron–Ion Covariance Reveals Geometry-Resolved Inner-Shell Spectra in CS 2 Photodissociation

The chemical shifts of inner-shell atomic orbitals are highly sensitive to chemical bonding and molecular structure. In evolving systems, however, the spectra of distinct molecular species and geometries overlap, obscuring the underlying chemical dynamics. Here we demonstrate the use of electron–ion covariance analysis to combine the structural sensitivity of Coulomb explosion imaging with inner-shell spectroscopy, yielding geometry-specific spectra of transient and product species. We apply this approach to the excited state dynamics of CS 2 probed by ionization above the S 2p edge. Electron–ion covariance with time- and momentum-selected S + and S 2+ ions isolates distinct S 2p photoelectron spectra for ground-state CS 2 , bent photoexcited CS 2 , the CS photoproduct, and bare atomic sulfur ─ species whose spectra overlap strongly in the channel-averaged measurement. Clear chemical shifts are observed in the covariance photoelectron spectrum for each of these species, all of which are consistent with high-level calculations. Here, by extracting the atomic S contribution to the photoelectron spectrum in a finely time-resolved manner we can disentangle this contribution to the overall time-resolved photoelectron spectrum as the photodissociation proceeds. These results demonstrate the promise of electron–ion covariance as a general approach to geometry-resolved inner-shell spectroscopy, opening a route to tracking structural evolution through chemical shifts in complex photoexcited molecules.

Ionization↗

Prolonging All-Optical Molecular Electron Spin Coherence in the Tissue Transparency Window

Coherent electron spin states within paramagnetic molecules hold significant potential for microscopic quantum sensing. However, all-optical coherence measurements amenable to high spatial and temporal resolution under ambient conditions remain a significant challenge. Here we conduct room-temperature, picosecond time-resolved Faraday ellipticity/rotation (TRFE/R) measurements of the electron spin decoherence time T 2 * in [IrBr 6 ] 2- . Decoherence is strongly sensitive to solution phase viscosity, pointing to molecular tumbling as an important decoherence mechanism. Accordingly, immobilization of [IrBr 6 ] 2- molecules in thin polymer films results in an order-of-magnitude increase in coherence lifetime and significantly greater magnetic field sensitivity. Here, by tuning energies of ligand-to-metal charge transfer (LMCT) states, TRFE/R enables spin initialization and readout in the tissue transparency window, paving the way toward all-optical, ultrafast molecular electron spin coherence imaging in biological systems.

Electron paramagnetic resonance spectroscopy↗

Direct observation of ultrafast symmetry reduction during internal conversion of 2-thiouracil using Coulomb explosion imaging

The photochemistry of heterocyclic molecules plays a decisive role for processes and applications like DNA photo-protection from UV damage and organic photocatalysis. The photochemical reactivity of heterocycles is determined by the redistribution of photoenergy into electronic and nuclear degrees of freedom, initially involving ultrafast internal conversion. Most heterocycles are planar in their ground state and internal conversion requires symmetry breaking. To lower the symmetry, the molecule must undergo an out-of-plane motion, which has not yet been observed directly. Here we show using the example of 2-thiouracil, how Coulomb explosion imaging can be utilized to extract comprehensive information on this molecular deformation, linking the extracted deplanarization of the molecular geometry to the previously studied temporal evolution of its electronic properties. Particularly, the protons of the exploded molecule are well-suited messengers carrying rich information on its geometry at distinct times after electronic excitation. We expect that our new analysis approach centered on these peripheral protons can be adapted as a general concept for future time-resolved studies of complex molecules in the gas phase.

Chemical physics↗

Efficient prediction of attosecond two-colour pulses from an X-ray free-electron laser with machine learning

Abstract X-ray free-electron lasers are sources of coherent, high-intensity X-rays with numerous applications in ultra-fast measurements and dynamic structural imaging. Due to the stochastic nature of the self-amplified spontaneous emission process and the difficulty in controlling injection of electrons, output pulses exhibit significant noise and limited temporal coherence. Standard measurement techniques used for characterizing two-coloured X-ray pulses are challenging, as they are either invasive or diagnostically expensive. In this work, we employ machine learning methods such as neural networks and decision trees to predict the central photon energies of pairs of attosecond fundamental and second harmonic pulses using parameters that are easily recorded at the high-repetition rate of a single shot. Using real experimental data, we apply a detailed feature analysis on the input parameters while optimizing the training time of the machine learning methods. Our predictive models are able to make predictions of central photon energy for one of the pulses without measuring the other pulse, thereby leveraging the use of the spectrometer without having to extend its detection window. We anticipate applications in X-ray spectroscopy using XFELs, such as in time-resolved X-ray absorption and photoemission spectroscopy, where improved measurement of input spectra will lead to better experimental outcomes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

BioCARS: Synchrotron facility for probing structural dynamics of biological macromolecules

A major goal in biomedical science is to move beyond static images of proteins and other biological macromolecules to the internal dynamics underlying their function. This level of study is necessary to understand how these molecules work and to engineer new functions and modulators of function. Stemming from a visionary commitment to this problem by Keith Moffat decades ago, a community of structural biologists has now enabled a set of x-ray scattering technologies for observing intramolecular dynamics in biological macromolecules at atomic resolution and over the broad range of timescales over which motions are functionally relevant. Many of these techniques are provided by BioCARS, a cutting-edge synchrotron radiation facility built under Moffat leadership and located at the Advanced Photon Source at Argonne National Laboratory. BioCARS enables experimental studies of molecular dynamics with time resolutions spanning from 100 ps to seconds and provides both time-resolved x-ray crystallography and small- and wide-angle x-ray scattering. Structural changes can be initiated by several methods—UV/Vis pumping with tunable picosecond and nanosecond laser pulses, substrate diffusion, and global perturbations, such as electric field and temperature jumps. Studies of dynamics typically involve subtle perturbations to molecular structures, requiring specialized computational techniques for data processing and interpretation. In this review, we present the challenges in experimental macromolecular dynamics and describe the current state of experimental capabilities at this facility. As Moffat imagined years ago, BioCARS is now positioned to catalyze the scientific community to make fundamental advances in understanding proteins and other complex biological macromolecules.

59 BASIC BIOLOGICAL SCIENCES↗

Spectroscopic investigation of early light emission from anode-initiated surface flashover in vacuum

Time-resolved optical emission spectroscopy is used to explore the early development of anode-initiated flashover in vacuum. An experimental apparatus for collecting flashover self-luminosity is introduced, which enables spatially resolved light collection from regions adjacent to the anode and cathode triple junctions. The emitted light is spectrally and temporally resolved utilizing an imaging spectrograph and a fast electronic shutter camera. The first light detectable from flashovers across both Rexolite and polytetrafluoroethylene (PTFE) insulators begins less than 10 ns prior to the flashover gap's impedance collapse and consists of faint broadband feature in primarily visible wavelengths. This suggests luminosity due to excitation in the solid, possibly occurring as a result of field emitted electrons. In the few nanoseconds leading up to and including the impedance collapse, the broadband spectrum grows in intensity and extends into the UV, eventually accompanied by a few emission lines of the insulator material. This is strong evidence that the early stages of anode-initiated flashover include surface layer breakdown of the insulator, as a contrast from cathode-initiated flashover, which is predominately an above-surface process. Spectra accumulated over longer exposures of PTFE flashovers indicate that, in the first few hundred nanoseconds after the impedance collapse, ions from the insulator material constitute the majority of the emission lines. Later, neutral and ionic metal species from the electrode contribute with similar prominence as well as molecular bands from diatomic carbon. Finally, a comparison is provided of the results of these studies to other spectroscopic investigations of vacuum flashover from the literature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

Planar laser-induced fluorescence system for spatiotemporal ion velocity distribution function measurements

In this work, we present a planar laser-induced fluorescence (PLIF) system for measuring two-dimensional (2D), spatiotemporally resolved ion velocity distribution functions (IVDFs). A continuous-wave tunable diode laser produces a laser sheet that irradiates the plasma, and the resulting fluorescence is captured by an intensified CCD (ICCD) camera. Fluorescence images recorded at varying laser wavelengths are converted into 2D IVDFs using the Doppler shift principle. The developed diagnostic is implemented in an electron beam generated E × B plasma with a bulk plasma density of $\sim\!\!{10^{10}}{\text{c}}{{\text{m}}^{ - 3}}$ . The developed diagnostic is validated against a conventional single-point LIF method using photomultiplier tube-based detection, while significantly reducing the total measurement time by the number of spatial positions measured. The time-resolving capability of this diagnostic is tested by oscillating the plasma between two nominal operating modes with different density profiles and triggering the ICCD camera by the externally driven plasma oscillation. The measured 2D IVDF maps reveal several signatures of ion dynamics in this plasma source, including radially outflowing ions across the electric field and anomalous ion heating at the periphery, consistent with recent kinetic simulations and theoretical studies. A possible correlation between these ion kinetic features and rotating spoke structures is discussed.

E×B plasma↗

N-dependent dynamics of root growth and nitrate and ammonium uptake are altered by the bacterium Herbaspirillum seropedicae in the cereal model Brachypodium distachyon

Nitrogen (N) fixation in cereals by root-associated bacteria is a promising solution for reducing use of chemical N fertilizers in agriculture. However, plant and bacterial responses are unpredictable across environments. We hypothesized that cereal responses to N-fixing bacteria are dynamic, depending on N supply and time. To quantify the dynamics, a gnotobiotic, fabricated ecosystem (EcoFAB) was adapted to analyse N mass balance, to image shoot and root growth, and to measure gene expression of Brachypodium distachyon inoculated with the N-fixing bacterium Herbaspirillum seropedicae. Phenotyping throughput of EcoFAB-N was 25–30 plants h -1 with open software and imaging systems. Herbaspirillum seropedicae inoculation of B. distachyon shifted root and shoot growth, nitrate versus ammonium uptake, and gene expression with time; directions and magnitude depended on N availability. Primary roots were longer and root hairs shorter regardless of N, with stronger changes at low N. At higher N, H. seropedicae provided 11% of the total plant N that came from sources other than the seed or the nutrient solution. The time-resolved phenotypic and molecular data point to distinct modes of action: at 5 mM NH 4 NO 3 the benefit appears through N fixation, while at 0.5 mM NH 4 NO 3 the mechanism appears to be plant physiological, with H. seropedicae promoting uptake of N from the root medium.Future work could fine-tune plant and root-associated microorganisms to growth and nutrient dynamics.

59 BASIC BIOLOGICAL SCIENCES↗

Direct Measurement of Ice-Ablator Interface Motion for Instability Mitigation in Indirect Drive ICF Implosions

In indirect drive inertial confinement fusion (ICF) implosions hydrodynamic instability growth at the imploding capsule ablator-DT fuel interface can reduce fuel compressibility and inject ablator into the hot spot hence reducing hot spot pressure and temperature. As a mitigation strategy, a gentle acceleration of this interface is predicted by simulations and theory to significantly reduce this instability growth in the early stage of the implosion. We have performed high-contrast, time-resolved x-ray refraction enhanced radiography (RER) to accurately measure the level of acceleration as a function of the initial laser drive time history for indirect-drive implosions on the National Ignition Facility. Here, we demonstrate a transition from no acceleration to 20 ± 1.8μm ns -2 acceleration by tweaking the drive that should reduce the initial instabilities by an order of magnitude at high modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Streaked Sub-ps-resolution X-ray Line Shapes and Implications for Solid-density Plasma Dynamics

A high-resolution x-ray spectrometer was coupled with an ultrafast x-ray streak camera to produce time-resolved line shape spectra measured from hot, solid-density plasmas. A Bragg crystal was placed near a laser-produced plasma to maximize throughput; alignment tolerances were established by raytracing. The streak camera produced single-shot time-resolved spectra, heavily sloped due to photon time-of-flight differences, with sufficient reproducibility to accumulate photon statistics. The images are time-calibrated by the slope of streaked spectra and dewarped to generate spectra emitted at different times defined at the source. The streaked spectra demonstrate the evolution of spectral shoulders and other features on ps timescales, showing the feasibility of plasma parameter measurements on the rapid timescales necessary to study high-energy-density plasmas.

High-energy-density plasmas↗

Imaging Wavepackets in Real-Space & Disentangling Ultrafast Solvation Dynamics with High-Energy Ultrafast X-ray Scattering

The microscopic information of solute and solute-solvent motions can be measured using ultrafast diffuse x-ray scattering, and compared to molecular dynamics simulations, as demonstrated in studies of solvated molecular systems done in X-ray free-electron lasers. However, for the typical photon energies used in these experiments, the photon momentum transfer range was limited to lower Q values where the signals arising from different parts of the studied system overlap significantly. Recently, this limitation was greatly alleviated by extending the photon energy at the Linac Coherent Light-Source (LCLS), significantly increasing the accessible momentum transfer range. This improvement is transformative for ultrafast diffuse x-ray scattering measurements, enabling for the first time to disentangle the solute scattering difference signal, that persists to higher Q values, from the bulk solvent and solute-solvent cross-terms difference signals. In addition, it enhances the prediction ability of modeling and simulation methods such as the hybrid QM/MM approach. The extended Q range also opens the way to resolve in real-space details regarding coherent wavepackets motions beyond their center-of-mass positions. Here, we present the first results on high-energy (18keV) diffuse x-ray scattering in solution, demonstrating high fidelity time-resolved scattering and analysis of the photoexcited model photocatalysts PtPOP ([Pt2(POP)4]4-), and IrDimen ([Ir2(dimen)4]2+) in several solvents. These complexes provide ideal systems for demonstrating the ability of high-Q ultrafast scattering and QM/MM simulations to decompose ultrafast solvation dynamics into specific changes in the solute-solvent pair distribution function with a particular focus on how electronically excited states change the interaction between the solvent and photo-catalytically active metal sites. We introduce an approach to further utilize the high-energy capability and demonstrate a single-shot ultra-wide-angle X-ray Scattering modality using two perpendicular detectors, spanning a scattering angle range of more than 100 degrees, allowing to extend the accessible momentum transfer range up to Q~14 Å-1. We develop a model-free method to invert the x-ray scattering signals and enable the recovery of multiple pair-density motions that happen simultaneously, allowing us to directly measure in real-space nuclear wavepacket motions. . [1] Natan, Adi. "Real-Space Inversion and Super-Resolution of Ultrafast X-ray Scattering using Natural Scattering Kernels." arXiv preprint arXiv:2107.05576 (2021)

Natan, Adi↗

National Ignition Facility Opacity Time Resolved Spectrometer Systems Engineering Final Project

The National Ignition Facility (NIF) is the world’s largest and most energetic laser facility. The NIF system is designed to produce high energy density (temperature and pressure) conditions through the application of its 192 laser beams. One of the users of NIF is the opacity platform developed to study the opacities at temperatures and densities relevant to the solar interior and stellar evolution. The platform was developed to study iron (Fe) opacity at temperatures relevant to the solar interior. The opacity campaign uses spectrometers to gather data. Spectrometers utilize crystals to produce x-ray spectra that are recorded on time-integrated and time-resolved detectors. The opacity spectrometer (OpSpec) currently fielded and in use at NIF uses a time integrated film channel to collect data. The opacity spectrometer time resolved (OpSpecTR) will utilize novel hCMOS detectors to capture time resolved images of spectra of interest. The key stakeholders identified for OpSpecTR included the physicists responsible for OpSpec and OpSpecTR, the Target Area Science and Engineering (TASE) department at NIF, the NIF and Photon Science (NIF & PS) Opacity program, the Nevada National Security Site (NNSS) Physics and Engineering program, the Sandia hCMOS manufacturing and testing program, and the Los Alamos National Laboratory (LANL) program sponsor. The Target and Experimental Operations (TEXOPS) was identified as a key stakeholder because the group includes the individuals that will physically interact with the OpSpecTR system as it participates in NIF experiments. The opacity platform collects data in a unique orientation relative to the existing diagnostics fielded at NIF. The existing infrastructure at NIF uses a diagnostic manipulator (DIM) to insert the diagnostic near the target chamber center to collect data during a NIF shot. Existing diagnostics collect data through the center line of the DIM axis and collect relevant data perpendicular to this axis. The opacity platform requires crystals mounted in a specific orientation which requires data collection parallel to the DIM axis. This deviation from standard NIF practices was a key factor in developing requirements.

42 ENGINEERING↗

Hard x-ray imaging and characterization of staged z-pinch plasmas in order to exclude ion beams as cause of fusion

Prior to the start of the INFUSE project, a 1-D x-ray device had been developed to detect > 5 keV x-rays and, by using the device as a pinhole camera, determine the location of the source of these x-rays. The system was also used in a non-camera mode to measure the energy of the X-rays by having different thicknesses of attenuating material on different pixels. This dual-purpose had been used in three plasma experiments: the laboratory magnetized plasma jet at Caltech, the laboratory solar nanoflare at Caltech, and at the 500 kA staged Z-pinch (CESZAR) at UCSD. Preliminary measurements at the UCSD facility indicated that hard x-rays with energies ranging from ~27 to over 100 keV were created and that these x-rays likely originated at the Z-pinch’s anode. These preliminary data also indicated that the x-rays’ origin was coincident with the moment of peak compression. The major goal of the INFUSE proposal was to confirm these preliminary results. This confirmation was to be made by improving the imaging capability to two dimensions, increasing the time resolution of the camera, and using the x-ray diagnostic alongside time-resolved neutron detectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wave Detection and Tracking Within a Rotating Detonation Engine Through Object Detection

As the operational time window of experimental rotating detonation engines (RDEs) is expanded and the technology matures toward integration within gas turbines, monitoring techniques must evolve to offer computationally efficient and highly time-resolved diagnostics. In this study, computer vision object detection methodology that seeks to reduce data processing time and calculate wave velocity within drastically reduced time intervals as compared to traditional high-frame-rate RDE images analysis techniques is proposed. The adapted you-only-look-once object detection network is trained to detect individual detonation waves within single down-axis RDE images. The wave location and rotational direction detected within a frame are tracked through a series of high-speed images to calculate the frame-to-frame wave velocity with the time-step resolution of $\mathrm{20 μs}$ across a series of frames. The analysis of the annotation box size and image linearization effects is presented, demonstrating the lowest frame-to-frame velocity total uncertainty of $\mathrm{±3.8\%}$ and the highest classification speed of 9.5 frames per second using linearized images. Linearized images “unwrap” the RDE annulus pixel region to a reduced image size. Here, this new method offers great reductions in data processing times and unsteady detonation behavior insight at intervals more comparable to the timescales of detonation wave interactions via the application of machine learning to experimental RDE data.

33 ADVANCED PROPULSION SYSTEMS↗

Acceleration of Near-IR Emission through Efficient Surface Passivation in Cd 3 P 2 Quantum Dots

Fast near-IR (NIR) emitters are highly valuable in telecommunications and biological imaging. The most established NIR emitters are epitaxially grown In x Ga 1-x As quantum dots (QDs), but epitaxial growth has several disadvantages. Colloidal synthesis is a viable alternative that produces a few NIR-emitting materials, but they suffer from long photoluminescence (PL) times. These long PL times are intrinsic in some NIR materials (PbS, PbSe) but are attributed to emission from bright trapped carrier states in others. We show that Cd 3 P 2 QDs possess substantial trap emission with radiative times >10 1 ns. Surface passivation through shell growth or coordination of Lewis acids is shown to accelerate the NIR emission from Cd 3 P 2 QDs by decreasing the amount of trap emission. This finding brings us one step closer to the application of colloidally synthesized QDs as quantum emitters.

36 MATERIALS SCIENCE↗

Characterization of Incremental Markings in the Sagittal Otolith of the Pacific Sardine ( Sardinops sagax ) Using Different Imaging Modalities

Teleost fish possess calcium carbonate otoliths located in separate chambers (utriculus, sacculus, and lagena) of their membranous labyrinth. This study analyzed the surface topography of the sagittal otolith of the Pacific sardine (Sardinops sagax) and the daily and annual increments in these otoliths. The otolith surface, characterized by laser scanning confocal microscopy for the first time, consisted of a system of prominent ridges and valleys (grooves), but it is unclear whether these structures are functional or represent time-resolving markings reflecting growth periodicity. Within the first-year volume, daily increments, each consisting of an incremental (more mineralized) and a discontinuous (less mineralized) zone, were resolved by optical microscopy and backscattered electron (BSE) imaging in the scanning electron microscope (SEM). Daily growth increments could, however, not be resolved in volumes formed after the first year, presumably because otolith growth markedly slows down and spacing of incremental markings narrows in older fish. Throughout otolith growth, the crystalline network continues across the discontinuous zones. Fluorochrome labeling provides additional information on growth after the first year. Compared with optical and BSE imaging, synchrotron microComputed Tomography of intact otoliths (with 0.69 µm volume elements) was less able to resolve daily increments; X-ray phase contrast reconstructions provided more detail than reconstructions with absorption contrast. Future research directions are proposed.

59 BASIC BIOLOGICAL SCIENCES↗