Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Adjoint Waveform Tomography for Next Generation Seismic Analyses and Monitoring

The development of methods and capabilities to compute complete waveform simulations in three-dimensional (3D) Earth models along with adjoint methods for computing the fully 3D sensitivity kernels in the 2000's set the stage for new advances in seismic imaging. I believe that the full benefits of adjoint waveform tomography (AWT) are not yet fully realized and this will be an important direction for the future of seismic tomography.

58 GEOSCIENCES↗

Adjoint waveform tomography of East Asia for improved waveform prediction

We present a preliminary version of the East Asia Tomography (EAT) model, an adjoint waveform tomography model of East and Southeast Asia. We used SPiRaL (Simmons et al., 2021) as our starting model and source parameters for 238 earthquakes from the Global Centroid Moment Tensor catalogue (Ekström et al., 2012). After 50 iterations on Lawrence Livermore National Laboratory’s Lassen supercomputer, we converge on a model with a minimum period of 50 seconds. The preliminary model shows improved slab structure compared to SPiRaL and shows significantly reduced misfit. In later versions of the model, we aim to harness techniques proposed in other studies to improve waveform predictions that travel through the ocean (e.g., Wehner et al., 2022) and use relative amplitude-based misfit functions (e.g., Tao et al., 2018) to better constrain Earth structure. We hope to iterate the current extent of the model to 25 seconds minimum period before iterating to shorter periods for a smaller subregion of the full model.

58 GEOSCIENCES↗

Technical Report on Adjoint Waveform Tomography of East Asia for Improved Waveform Prediction

We present a preliminary version of the East Asia Tomography (EAT) model, an adjoint waveform tomography model of East and Southeast Asia. We used SPiRaL (Simmons et al., 2021) as our starting model and source parameters for 250 earthquakes from the Global Centroid Moment Tensor catalogue (Ekström et al., 2012). Over 198 iterations, we have iterated the EAT model down to a minimum period of 35 seconds. We plan on continuing our iteration technique down to 30 seconds period before updating our misfit function to use a normalized cross correlation-based misfit functions (e.g., Tao et al., 2018) to better constrain Earth structure. We hope to iterate the current extent of the model to 25 seconds minimum period before iterating to shorter periods for a smaller subregion of the full model.

58 GEOSCIENCES↗

Longitudinal Phase Space Tomography for the Booster Synchrotron

Efforts in the study of the longitudinal behavior of charged particles in the Fermilab Booster can be catalyzed with an image of the two-dimensional phase space distribution. In the past, tomography has been extensively employed in the reconstruction of the phase space in accelerators such as the Recycler at Fermilab and the Proton Synchrotron Booster at CERN. However, such a capability had yet to realize for the Fermilab Booster synchrotron. In this work, the first successful tomographic phase space reconstruction of a low-energy Booster bunch is presented along with validation metrics. A numerical turn-by-turn model of the longitudinal particle dynamics in the Booster has been implemented, which utilizes a fast, map-based particle transport algorithm. Using a sinogram generated from the Wall Current Monitor, the iterative reconstruction algorithm recovers a discretized image of the original phase space distribution at variable resolution. The reconstruction result shows low root-mean-square error and a rapid convergence toward the solution, providing strong evidence of accuracy. Future and ongoing work includes modeling high-energy bunches above transition and using tomography to infer certain machine parameters such as synchronous phase, peak gap voltage, and synchronous energy in addition to the phase space distribution.

Ebeid, Safi [Unlisted]↗

Longitudinal Phase Space Tomography for the Booster Synchrotron (Abstract Only)

Efforts in the study of the longitudinal behavior of charged particles in the Fermilab Booster can be catalyzed with an image of the two-dimensional phase space distribution. In the past, tomography has been extensively employed in the reconstruction of the phase space in accelerators such as the Recycler at Fermilab and the Proton Synchrotron Booster at CERN. However, such a capability had yet to realize for the Fermilab Booster synchrotron. In this work, the first successful tomographic phase space reconstruction of a low-energy Booster bunch is presented along with validation metrics. A numerical turn-by-turn model of the longitudinal particle dynamics in the Booster has been implemented, which utilizes a fast, map-based particle transport algorithm. Using a sinogram generated from the Wall Current Monitor, the iterative reconstruction algorithm recovers a discretized image of the original phase space distribution at variable resolution. The reconstruction result shows low root-mean-square error and a rapid convergence toward the solution, providing strong evidence of accuracy. Future and ongoing work includes modeling high-energy bunches above transition and using tomography to infer certain machine parameters such as synchronous phase, peak gap voltage, and synchronous energy in addition to the phase space distribution.

Ebeid, Safi [Unlisted, US]↗

Gate Set Tomography

Gate set tomography (GST) is a protocol for detailed, predictive characterization of logic operations (gates) on quantum computing processors. Early versions of GST emerged around 2012-13, and since then it has been refined, demonstrated, and used in a large number of experiments. This paper presents the foundations of GST in comprehensive detail. The most important feature of GST, compared to older state and process tomography protocols, is that it is calibration-free . GST does not rely on pre-calibrated state preparations and measurements. Instead, it characterizes all the operations in a gate set simultaneously and self-consistently, relative to each other. Long sequence GST can estimate gates with very high precision and efficiency, achieving Heisenberg scaling in regimes of practical interest. In this paper, we cover GST's intellectual history, the techniques and experiments used to achieve its intended purpose, data analysis, gauge freedom and fixing, error bars, and the interpretation of gauge-fixed estimates of gate sets. Our focus is fundamental mathematical aspects of GST, rather than implementation details, but we touch on some of the foundational algorithmic tricks used in the pyGSTi implementation.

97 MATHEMATICS AND COMPUTING↗

Dual-unitary shadow tomography

We introduce a classical shadow tomography scheme based on dual-unitary brick-wall circuits termed "dual-unitary shadow tomography" (DUST). For this we study operator spreading and Pauli weight dynamics in one-dimensional qubit systems, evolved by random two-local dual-unitary gates arranged in a brick-wall structure, ending with a final measurement layer. We do this by deriving general constraints on the Pauli weight transfer matrix and specializing to the case of dual-unitarity. We first show that dual-unitaries must have a minimal amount of entropy production. Remarkably, we find that operator spreading in these circuits have a rich structure resembling that of relativistic quantum field theories, with massless chiral excitations that can decay or fuse into each other, which we call left- or right-movers. We develop a mean-field description of the Pauli weight in terms of $\rho(x,t)$, which represents the probability of having nontrivial support at site $x$ and depth $t$ starting from a fixed weight distribution. We develop an equation of state for $\rho(x,t)$, and simulate it numerically using Monte Carlo simulations. Lastly, we demonstrate that the fast-thermalizing properties of dual-unitary circuits make them better at predicting large operators than shallow brick-wall Clifford circuits. Our results are robust to finite-size effects due to the chirality of dual-unitary brick-wall circuits.

97 MATHEMATICS AND COMPUTING↗

High-Resolution Scanning Coded-Mask-Based X-ray Multi-Contrast Imaging and Tomography

Near-field X-ray speckle tracking has been used in phase-contrast imaging and tomography as an emerging technique, providing higher contrast images than traditional absorption radiography. Most reported methods use sandpaper or membrane filters as speckle generators and digital image cross-correlation for phase reconstruction, which has either limited resolution or requires a large number of position scanning steps. Recently, we have proposed a novel coded-mask-based multi-contrast imaging (CMMI) technique for single-shot measurement with superior performance in efficiency and resolution compared with other single-shot methods. We present here a scanning CMMI method for the ultimate imaging resolution and phase sensitivity by using a coded mask as a high-contrast speckle generator, the flexible scanning mode, the adaption of advanced maximum-likelihood optimization to scanning data, and the multi-resolution analysis. Scanning CMMI can outperform other speckle-based imaging methods, such as X-ray speckle vector tracking, providing higher quality absorption, phase, and dark-field images with fewer scanning steps. Scanning CMMI is also successfully demonstrated in multi-contrast tomography, showing great potentials in high-resolution full-field imaging applications, such as in vivo biomedical imaging.

Qiao, Zhi (ORCID:0000000233928732)↗

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Neutrons have historically been used for a broad range of biological applications employing techniques such as small-angle neutron scattering, neutron spin echo, diffraction, and inelastic scattering. Unlike neutron scattering techniques that obtain information in reciprocal space, attenuation-based neutron imaging measures a signal in real space that is resolved on the order of tens of micrometers. The principle of neutron imaging follows the Beer-Lambert law and is based on the measurement of the bulk neutron attenuation through a sample. Greater attenuation is exhibited by some light elements (most notably, hydrogen), which are major components of biological samples. Contrast agents such as deuterium, gadolinium, or lithium compounds can be used to enhance contrast in a similar fashion as it is done in medical imaging, including techniques such as optical imaging, magnetic resonance imaging, X-ray, and positron emission tomography. For biological systems, neutron radiography and computed tomography have increasingly been used to investigate the complexity of the underground plant root network, its interaction with soils, and the dynamics of water flux in situ. Moreover, efforts to understand contrast details in animal samples, such as soft tissues and bones, have been explored. This manuscript focuses on the advances in neutron bioimaging such as sample preparation, instrumentation, data acquisition strategy, and data analysis using the High Flux Isotope Reactor CG-1D neutron imaging beamline. The aforementioned capabilities will be illustrated using a selection of examples in plant physiology (herbaceous plant/root/soil system) and biomedical applications (rat femur and mouse lung).

Bilheux, Hassina↗

Nanoscale optical tomography with cathodoluminescence spectroscopy

In one aspect, a cathodoluminescence (CL) spectroscopic tomography device includes a sample stage to support a sample. An electron beam source scans an electron beam over the sample to yield light emission by the sample. A reflective element directs the light emission by the sample to a light detector. A controller controls operation of the sample stage, the electron beam source, and the light detector. In one aspect, a CL spectroscopic tomography device includes an electron beam source which directs an electron beam at an object to yield an emission by the object. A detector detects the emission. A controller receives information from the detector related to the detected emission. The controller derives a two-dimensional (2D) CL map from the information related to the detected emission, and derives a three-dimensional (3D) CL tomogram from the 2D CL map.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring 3D Chemistry at 1 nm Resolution with Fused Multi-Modal Electron Tomography

Measuring the three-dimensional (3D) distribution of chemistry in nanoscale matter is a longstanding challenge for metrological science. The inelastic scattering events required for 3D chemical imaging are too rare, requiring high beam exposure that destroys the specimen before an experiment is completed. Even larger doses are required to achieve high resolution. Thus, chemical mapping in 3D has been unachievable except at lower resolution with the most radiation-hard materials. Here, high-resolution 3D chemical imaging is achieved near or below one-nanometer resolution in an Au-Fe3O4 metamaterial within an organic ligand matrix, Co3O4-Mn3O4 core-shell nanocrystals, and ZnS-Cu0.64S0.36 nanomaterial using fused multi-modal electron tomography. Multi-modal data fusion enables high-resolution chemical tomography often with 99% less dose by linking information encoded within both elastic (HAADF) and inelastic (EDX/EELS) signals. We thus demonstrate that sub-nanometer 3D resolution of chemistry is measurable for a broad class of geometrically and compositionally complex materials.

Schwartz, Jonathan↗

Longitudinal Phase Space Tomography for the Booster Synchrotron

Efforts in the study of the longitudinal behavior of charged particles in the Fermilab Booster can be catalyzed with an image of the two-dimensional phase space distribution. In the past, tomography had been employed in the reconstruction of the phase space in accelerators such as the Recycler at Fermilab and the Proton Synchrotron Booster at CERN. However, such a capability had yet to realize for the Fermilab Booster synchrotron. In this work, the first successful tomographic phase space reconstruction of a low-energy Booster bunch is presented along with validation metrics. A numerical turn-by-turn model of the longitudinal particle dynamics in the Booster has been implemented, which utilizes a fast, map-based particle transport algorithm. Using a sinogram generated from the Wall Current Monitor signal, the iterative reconstruction algorithm recovers a discretized image of the original phase space distribution at variable resolution. The reconstruction result shows low root-mean-square error and a rapid convergence toward the solution, providing strong evidence of accuracy. Future and ongoing work includes modeling high-energy bunches above transition and using tomography to infer certain machine parameters such as synchronous phase, peak gap voltage, and synchronous energy in addition to the phase space distribution.

Ebeid, Safi [Unlisted; Fermilab]↗

Exploiting voxel-sparsity for bone imaging with sparse-view cone-beam computed tomography

An optimization-based image reconstruction frame work is developed specifically for bone imaging. This framework exploits voxel-sparsity by use of ℓ 1 -norm image regularization and it enables image reconstruction from sparse-view cone-beam computed tomography (CBCT) acquisition. The effectiveness of the voxel-sparsity regularization is enhanced by using a blurred image representation. Ramp-filtering is included in the data discrepancy term and it has the effect of acting as a preconditioner, reducing the necessary number of iterations. The bone image reconstruction framework is demonstrated on CBCT data taken from an equine metacarpal condyle specimen.

Bone imaging↗

Multiscale Characterization of Additive Manufacturing Components with Computed Tomography, 3D X-ray Microscopy, and Deep Learning

Additive manufacturing (AM) facilitates the creation of complex-geometry parts, driving advancements in lightweight aerospace components, high-efficiency engine cooling channels, and customized medical implants. However, ensuring the quality and reliability of AM parts remains challenging due to internal defects, surface irregularities, porosity, and residual trapped powder, which are often inaccessible to traditional inspection methods. Recent developments in X-ray computed tomography (XCT) and 3D X-ray microscopy (XRM), particularly systems equipped with resolution-at-a-distance (RaaD™) capabilities, enable high-resolution, non-destructive evaluation of AM components across multiple scales, from sub-micrometer to macroscopic levels. This paper explores modern XCT and XRM techniques for multiscale characterization of AM parts, focusing on their ability to detect and analyze defects such as porosity, cracks, inclusions, and surface roughness, while offering insights into defect formation mechanisms, material properties, and process-induced variations. The integration of deep learning (DL) frameworks, including Simurgh, DeepRecon, and DeepScout, enhances XCT/XRM workflows by reducing scan times, improving resolution recovery, and enabling accurate defect detection even with limited projection data. These DL-based methods overcome limitations of traditional reconstruction techniques, enabling faster, more reliable characterization of dense materials like Inconel 718 and novel alloys such as AlCe. Applications include process parameter optimization, high-throughput quality control, and multistage AM process evaluation, with DL-enhanced workflows accelerating analysis times from weeks to days. Correlative imaging approaches further validate XCT and XRM data against scanning electron microscopy (SEM) images of physically sectioned samples, confirming the accuracy of DL-based reconstructions and enabling comprehensive defect analysis. While challenges remain in generalizing DL models to diverse materials and imaging conditions, improvements in resolution, noise reduction, and defect detection highlight the transformative potential of these methods. This multiscale and correlative approach enables precise identification and correlation of microstructural features with the overall performance of AM components. By integrating advanced XCT, XRM, and DL techniques, this paper demonstrates a significant leap forward in AM characterization, offering valuable insights into the relationships between processing parameters, microstructure, and part performance, and driving innovations that enhance the quality and reliability of AM products for demanding industrial applications.

Additive manufacturing↗

New frontiers in atom probe tomography: a review of research enabled by cryo and/or vacuum transfer systems

There has been a recent surge in the use of cryo and/or vacuum specimen preparation and transfer systems that are broadening the scope of research enabled by the microscopy technique of atom probe tomography. This is driven by the fact that, like for many microscopes, the application of atom probe to air and temperature sensitive materials or wet biological specimens has previously been limited by through-air-transfer and through-vacuum-transfer at room temperature. Here we provide an overview of the critical areas of research that require these new transfer and analysis protocols, as well as a review of current advances in transfer devices, environmental cells and glove boxes for controlled sample manipulation. This includes the study of catalysis and corrosion, the application of atom probe to biological samples, the study of liquid-solid interfaces, natural ageing investigations and the analysis of hydrogen in metals.

36 MATERIALS SCIENCE↗

X-ray Nanocomputed Tomography in Zernike Phase Contrast for Studying 3D Morphology of Li–O 2 Battery Electrode

In this work, we investigated the lithium peroxide (Li 2 O 2 ) and pore size distribution in lithium-O 2 battery electrodes at different states of charge using transmission X-ray microscopy coupled with Zernike phase contrast to carry out nano-Computed Tomography. We report that such technique enables, at the nanoscale, to distinguish light elements such as carbon and Li 2 O 2 in Li-O 2 battery cathode electrodes. We verified by wave-propagation simulation that this approach efficiently improves the contrast of images in comparison with the pure absorption. The Li 2 O 2 distribution and thickness, interphases, and pore network are visualized and quantified, which give a valuable insight into our cathode architecture. From this 3D analysis, we highlight modifications of the air-cathode morphology and the Li 2 O 2 spatial organization as well as their potential implication in terms of carbon surface passivation and pore-clogging. After the full recharge process, this technique can also reveal the spatial distribution of the residual Li 2 O 2 and other byproducts.

25 ENERGY STORAGE↗

Angle between DNA linker and nucleosome core particle regulates array compaction revealed by individual-particle cryo-electron tomography

Abstract The conformational dynamics of nucleosome arrays generate a diverse spectrum of microscopic states, posing challenges to their structural determination. Leveraging cryogenic electron tomography (cryo-ET), we determine the three-dimensional (3D) structures of individual mononucleosomes and arrays comprising di-, tri-, and tetranucleosomes. By slowing the rate of condensation through a reduction in ionic strength, we probe the intra-array structural transitions that precede inter-array interactions and liquid droplet formation. Under these conditions, the arrays exhibite irregular zig-zag conformations with loose packing. Increasing the ionic strength promoted intra-array compaction, yet we do not observe the previously reported regular 30-nanometer fibers. Interestingly, the presence of H1 do not induce array compaction; instead, one-third of the arrays display nucleosomes invaded by foreign DNA, suggesting an alternative role for H1 in chromatin network construction. We also find that the crucial parameter determining the structure adopted by chromatin arrays is the angle between the entry and exit of the DNA and the corresponding tangents to the nucleosomal disc. Our results provide insights into the initial stages of intra-array compaction, a critical precursor to condensation in the regulation of chromatin organization.

59 BASIC BIOLOGICAL SCIENCES↗

Continuity of Mitochondrial Budding: Insights from BS-C-1 Cells by In Situ Cryo-electron Tomography

Mitochondrial division is a fundamental biological process essensial for cellular functionality and vitality. The prevailing hypothesis that dynamin related protein 1 (Drp1) provides principal control in mitochondrial division, in which it also involves the endoplasmic reticulum (ER) and the cytoskeleton, does not account for all the observations. Therefore. the hypothesis may be incomplete. Our previous study in HeLa cells led to a new hypothesis of mitochondrial division by budding. To follow-up our previous study, we employed in situ cryo-electron tomography to visualize mitochondrial budding in the intact healthy monkey kidney cells (BS-C-1 cells). Our findings reaffirm single and multiple mitochondrial budding, consistent with our observations in HeLa cells. Notably, the budding regions vary significantly in diameter and length, which may represent different stages of budding. More interestingly, neither rings nor ring-like structures, nor the wrapping of ER tubes was observed in the budding regions, suggesting mitochondrial budding is independent from Drp1 and ER. Meanwhile, we uncovered direct interactions between mitochondria and large vesicles that are distinct from small mitochondrial-derived vesicles and extracellular mitovesicles. In conclusion, we propose that these interacting vesicles may have mitochondrial origins.

(Cryo-EM)↗