Search NASA⌕ Search

SEARCH · Search NASA

Results for “Total”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Non-destructive spatial analysis of phosphatase activity and total protein distribution in the rhizosphere using a root blotting method

Phosphorus (P) is an essential macronutrient for plant growth, but bioavailable P in soils is often limited due to immobilization resulting from pH and geochemical interactions. Understanding the dynamics of P in soils and elucidating the mechanisms by which plants access P from their environment are critical to evaluating productivity, particularly in nutrient poor environments. Phosphorus from organic matter can act as a major source of P for organisms in soil systems. Phosphatases, enzymes that liberate inorganic P from organic sources, are produced by both plants and microbes and are considered one of the most active classes of enzymes in soil. In this work we developed a root blotting method to spatially image phosphatase activity in the rhizosphere. Proteins from the rhizosphere are transferred to a nitrocellulose membrane while retaining their enzymatic activity and two-dimensional spatial distribution. Subsequent application of a fluorogenic phosphatase indicator, DDAO phosphate, enables visualization of the distribution of phosphatase activity in the sample. The proteins can then be fixed to the membrane and treated with a SYPRO® Ruby gel stain, a fluorescent total protein stain, allowing for visualization of total protein distribution. Taken together, the images of phosphatase activity and total protein localization can be mapped back to the root architecture and provide insight into factors affecting the spatial distribution of enzymatic activity and protein accumulation in the rhizosphere. Notably, this method can be applied to plants growing in rhizoboxes containing soil or soilless growth mixtures (e.g., sand or various potting mixes) and, because of the non-destructive nature of this approach, be performed over time to track changes. We anticipate that this fluorescent indicator imaging technique on root blots can be used in diverse plant-microbe-soil systems to better understand the role of phosphatases in P acquisition and soil P cycling.

59 BASIC BIOLOGICAL SCIENCES↗

Viromes outperform total metagenomes in revealing the spatiotemporal patterns of agricultural soil viral communities

Abstract Viruses are abundant yet understudied members of soil environments that influence terrestrial biogeochemical cycles. Here, we characterized the dsDNA viral diversity in biochar-amended agricultural soils at the preplanting and harvesting stages of a tomato growing season via paired total metagenomes and viral size fraction metagenomes (viromes). Size fractionation prior to DNA extraction reduced sources of nonviral DNA in viromes, enabling the recovery of a vaster richness of viral populations (vOTUs), greater viral taxonomic diversity, broader range of predicted hosts, and better access to the rare virosphere, relative to total metagenomes, which tended to recover only the most persistent and abundant vOTUs. Of 2961 detected vOTUs, 2684 were recovered exclusively from viromes, while only three were recovered from total metagenomes alone. Both viral and microbial communities differed significantly over time, suggesting a coupled response to rhizosphere recruitment processes and/or nitrogen amendments. Viral communities alone were also structured along an 18 m spatial gradient. Overall, our results highlight the utility of soil viromics and reveal similarities between viral and microbial community dynamics throughout the tomato growing season yet suggest a partial decoupling of the processes driving their spatial distributions, potentially due to differences in dispersal, decay rates, and/or sensitivities to soil heterogeneity.

59 BASIC BIOLOGICAL SCIENCES↗

A Novel Method for Preoperative Positioning of Total Ankle Replacement Using 3D Digital Model

Abstract Objective To establish a digital model of the ankle joint through 3D imaging technology and explore the preoperative placement of ankle replacement prostheses. Methods Computed tomography images of intact ankle joints from 54 cases in the outpatient and inpatient departments of our hospital were collected; according to the INBONE® total ankle system surgery process, the surgery model and surgical osteotomy were finished using MIMICS based on computer simulation method. The shortest distance was measured between the center point and the anterior, posterior, medial, and lateral, respectively, to ensure the precise position of the ankle replacement prosthesis by digital simulation surgery. The relationship between the two variables was analyzed by bivariate correlation analysis. Results The dataset of this study included 48 cases of the sub‐data set (26 males and 22 females) and included 27 cases of left ankle and 21 cases of right ankle. The average medial malleolar angle was 18.67°± 2.87°, the average amount of bone resection was 12.13 ± 1.86 cm 3 , the mid‐anterior distance was 1.72 ± 0.19 cm, the mid‐posterior distance was 2.00 ± 0.19 cm, the ratio of mid‐anterior to mid‐posterior was 0.87, the mid‐medial distance was 1.26 ± 0.17 cm, the mid‐lateral distance was 1.19 ± 0.16 cm, and the ratio of mid‐medial to mid‐lateral was 1.06. After osteotomy, the anteroposterior diameter was 3.73 ± 0.32 cm, the transverse diameter was 2.46 ± 0.27 cm, and the ratio of anteroposterior diameter to transverse diameter was 1.53. In the bottom view, the shape after osteotomy is rectangular. The mid‐anterior distance was strongly negatively correlated with age, the mid‐anterior distance and the amount of bone resection, the mid‐medial distance and the amount of bone resection, the mid‐lateral distance and the amount of bone resection, the mid‐lateral distance and the anteroposterior diameter, the anteroposterior diameter and the transverse diameter were all strongly positively correlated. Conclusion The projection point of the lower tibia centerline on the tibial horizontal osteotomy surface is located at a position slightly anterior to the midpoint of the transverse diameter after ankle arthroplasty. The rational positioning of the total ankle replacement is located at both a position slightly anterior to the midpoint of the transverse diameter and midpoint of the anteroposterior diameter, which can be used as a reference method before total ankle arthroplasty surgery.

Wu, Shi‐xun↗

T3CO (Transportation Technology Total Cost of Ownership) Open Source [SWR-21-54]

T3CO (Transportation Technology Total Cost of Ownership), is open source software for modeling total cost of ownership for commercial vehicles with advanced powertrains. T3CO is a modeling framework for determining geospatially and temporally optimized total cost of ownership (TCO) for vehicle powertrain technologies. T3CO runs NREL's FASTSim™ software for a representative set of operating conditions to minimize TCO based on vehicle parameters that affect purchase and operating costs (e.g., fuel/electricity consumption, asset depreciation, opportunity costs associated with charging time) while simultaneously ensuring that firm performance constraints (e.g. zero-to-sixty time, gradeability) are satisfied. T3CO will enable the user to control which powertrain parameters are used in optimizing TCO, and these parameters will be modified by a multi-objective optimization (MOO) algorithm to identify a Pareto-optimal solution set. The optimization algorithm will be modular so that users can choose from many different MOO options or insert their own user-defined optimization tool. NREL T3CO Homepage: https://www.nrel.gov/transportation/t3co.html PyPI package: https://pypi.org/project/t3co/

Lustbader, Jason↗

Total metals, sulfur and organic carbon data; Slate River floodplain, Crested Butte, CO; March 2021-October 2021

This data package includes processed and undiluted measurements for metal, sulfur and organic carbon concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between March and October of 2021. These measurements were all recorded at the Environmental Measurements Facility (EM-1) at Stanford University in Stanford, CA. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 2C until measured at EM-1.Analysis by ICP-MS:Measurements for total metals were performed on an inductively coupled plasma optical emission spectrometer (ICP-OES; iCAP 6300, Thermo Scientific, Cambridge, U.K.). Calibration standards were prepared from the mulit element stock solution (Sigma-Aldrich Multielement standard for ICP, St. Louis, MO) using matrix matched to sample solutions (2% HNO3). Calibration curves included 5 points with correlation coefficients of >0.99. The QC protocol includes a continuing calibration blank and quality control samples that are analyzed just after calibration and again every 20 samples and at the completion of the run. Acceptable QC responses must be between 90-110% of the certified value. Analysis by Total Organic Carbon:Dissolved organic carbon concentrations were quantified on a total organic carbon (TOC) analyzer (TOC-L, Shimadzu, Kyoto, Japan) running the NPOC method. Standard curves were developed using an Organic Carbon Standard from RICCA Chemical Company (Arlington,TX). A series of 4 to 6 standards were automatically diluted by the instrument in a concentration range that spans that of the samples. A blank sample was run just after the calibration curve and at the end of the run. A QC sample was run every 25 samples. Acceptable QC responses must be between 90-110% of the certified value.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Spatial Study 2022: Water Column, Sediment, and Total Ecosystem Respiration Rates across the Yakima River Basin, Washington, USA (v2)

This dataset supports a broader study examining the drivers of spatial variability in sediment respiration rates in the Yakima River Basin and is associated with the manuscript “Sediment-associated processes account for most of the spatial variation in ecosystem respiration in the Yakima River basin” submitted to Nature Communications Earth & Environment (Garayburu-Caruso et al., in review). The dataset provides ecosystem metabolism estimates generated from streamMetabolizer (Appling et al.; 2018) using data collected during the same five-week period at 48 sites within multiple rivers throughout the Yakima River Basin in Washington, USA. Additionally, it includes the scripts used for the analysis and producing the figures in the manuscript. The contents include streamMetabolizer inputs and outputs and additional relevant data needed to generate the main manuscript results. The data included are: total ecosystem respiration, water respiration, calculated sediment-associated respiration, gross primary production outputs from the river corridor model for the Yakima River Basin, median grain size (d50), depth, dissolved oxygen, water temperature, pressure, and annual oxygen consumption. The associated GitHub repository can be found at https://github.com/river-corridors-sfa/SSS_metabolism. Samples collected during this study were labeled as “Second Spatial Study” or “SSS.” Raw time series sensor data, total suspended solids, and depth data from SSS were published at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1969566. A subset of data from the SSS samples were published in the contiguous United States (CONUS)-Scale Model-Sample (CM) study data package available at https://data.ess-dive.lbl.gov/view/doi:10.15485/1923689 that presents data from across the CONUS. They include dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC), total nitrogen (TN), grain size, aerobic sediment respiration, dissolved oxygen (DO), and temperature. Parent IDs and Site IDs are consistent between the SSS and CM data packages, and they can be mapped directly so data across packages can be used together. Field metadata for the samples in this da This dataset is comprised of one main data folder with four subfolders. The main data folder contains of (1) file-level metadata; (2) data dictionary; (3) total/water column/sediment respiration; (4) gross primary production (GPP); (5) median grain size (d50); and (6) annual oxygen consumption. The “Figures” subfolder contains the figures used in the paper and all intermediate files (including geospatial files). The “Published_Data” contains a readme directing the user to download the public data to reproduce analyses and figures. The “Scripts” folder contains all scripts used in the analyses that were not part of running StreamMetabolizer. Lastly, the “Stream_Metabolizer” folder contains all files associated with running StreamMetabolizer including (1) model input files, (2) model output files, (3) processing scripts, (4) histogram plots of the outputs, and (5) an R project. All files are .csv, .pdf, .R, .Rmd, .Rproj, .html, .png, .txt, .qgz, .cpg, .dbf, .prj, .shp, .shp.ea.iso.xml, .shp.iso.xml, .shx, .sbn. ta package can be found at either link. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected these data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Total Measurement Uncertainty in Neutron Coincidence Multiplicity Analysis

Neutron multiplicity counting is the most commonly used nondestructive assay technique for determining the plutonium mass within containers of scrap PuO 2 or mixed oxide (MOX). In multiplicity analysis, the 240 Pu eff mass, leakage multiplication, and alpha ratio (the ratio of [α, n]-to-spontaneous fission neutron production) are the three primary unknown sample properties. They must be determined simultaneously. To solve for these three unknowns in a multiplicity assay, three measured values are needed: the singles, doubles, and triples neutron count rates. While the analysis is limited to solving for three unknowns, there are many additional factors that impact the observed count rates and contribute to the measurement uncertainty. In this study we investigate the various uncertainty contributors for the multiplicity analysis through a combination of traditional uncertainty propagation techniques supplemented by Monte Carlo simulations to address the dependences not explicitly expressed by the point source model. Uncertainties arising from counting statistics, calibration parameters, calibration method, nuclear data, and various material characteristics (isotopic abundances, chemical form, density, and impurities) are considered. A Total Measurement Uncertainty (TMU) estimate is then developed from these uncertainty contributors. This study is confined to multiplicity analysis of items commonly encountered in international safeguards applications. That is, the study focused on Pu oxides and MOX materials for the masses ranging up to 4000 grams total Pu. Multiplicity measurements were simulated using MCNP V6 based on the Plutonium Scrap Multiplicity Counter (PSMC), Epithermal Multiplicity Counter (ENMC), Pyrochemical Multiplicity Counter, and Large Epithermal Multiplicity Counter (LEMC) for this study; however, this report focuses on the parameterization of the uncertainties for the PSMC. The performance differences between the PSMC and the other multiplicity counting systems are relatively small, primarily manifesting in the impact on measurement precision so that the evaluation developed for the PSMC can be applied to the other multiplicity counting systems. Finally an analysis tool, the Multiplicity TMU Estimator, was developed from this study to serve as an aid for evaluation of the total measurement uncertainty of multiplicity assay results obtained from the commonly used INCC acquisition and analysis software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sample Preparation Method for Low-Level Total 129 I Measurements by ICP-MS

Trace-level measurements of iodine’s isotopic ( 129 I and 127 I) and chemical species distributions are needed for an accurate understanding of radioiodine migration in the Hanford subsurface. Pacific Northwest National Laboratory (PNNL) previously developed a novel analytical method for iodine characterization that uses ion chromatography (IC) coupled to inductively coupled mass spectrometry (ICP-MS). While the method can measure speciated forms of 129 I at levels below the drinking water standard, an interference from molybdenum (Mo) prevents the assay from quantifying the $\underline{total}$ 129 I concentration in many Hanford sample matrices. In this work, solvent extraction was evaluated as a sample preparation method for eliminating the Mo interference. A series of 10 experiments was conducted in which solutions containing known amounts of iodate or iodide were treated by solvent extraction, and the extracted solutions were analyzed for total iodine concentrations by ICP MS. Several extraction parameters such as reagent concentrations and chemical reaction times were systematically adjusted in attempts to optimize the extraction process. While solvent extraction was shown to be effective at removing Mo, there was a consistent inability to recover more than approximately 75% of the total iodine in most experiments. This would reduce the ability to detect 129 I at levels near the drinking water standard. Additionally, the extraction efficiencies in several experiments were highly variable, suggesting that solvent extraction could add significant uncertainty to radioiodine measurements. We recommend evaluating ion exchange as an alternative sample preparation approach in fiscal year (FY) 2024.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Total Effective Dose from Radiologic Emissions from INL Facilities for Calculation of Population Dose for the INL 2024 Annual Site Environmental Report

Total effective radiation dose from airborne releases was calculated using air dispersion modeling performed by the National Oceanic and Atmospheric Administration (NOAA) Idaho Falls Office using their HYSPLIT computer model (Stein et al. 2015; Draxler et al. 2013), and the Dose Multi-Media (DOSEMM) dose assessment model (Rood 2019) . The objective of these calculations was to provide a grid of total effective dose across a model domain that encompasses a 50-mile (80-km) radius from any Idaho National Laboratory (INL) Site source. In addition to INL Site sources, releases from the Radiological and Environmental Sciences Laboratory (RESL) (IF-683) and IF-603 located at the INL Research Center (IRC) within the Idaho Falls city limits were also included. Due to tracking limitations, radionuclides released from IF-611 and IF-603 are modeled as released from IF-603. The dose results will be combined with GIS software to compute a total population dose for the calendar year (CY) 2024 and will be reported in the INL Annual Site Environmental Report (ASER). This report does not cover the population dose calculation and only documents generation of the gridded dose file.

42 - ENGINEERING↗

Component pose reconstruction using a single robotic total station for panelized building envelopes

The construction industry can benefit greatly from increased automation in construction processes in terms of precision, time, and labor costs. This is especially true for prefabricated construction for either new buildings or envelope retrofits. Here, prefabricated components are manufactured offsite according to design specifications and installed onsite. Accurate information on the component’s position and orientation (pose) is needed to achieve this. A tool named “Real-Time Evaluator” (RTE), designed to autonomously track prefabricated components as they are being installed and provide real-time installation instructions, is currently under development using a single robotic total station. This is challenging since at least three points are needed to determine the pose of an object in space. To achieve this goal with a single robotic total station, two key algorithms were developed: the “resection” algorithm aligns the digital twin with the physical twin regardless of the location of the total station, and the “transformation” algorithm gives instructions of translations and rotations to installers to achieve the desired installation pose. The algorithms were evaluated experimentally on a lab-scale demonstration. Results show that the resection algorithm achieved an average error of < 3.1 mm, while the transformation algorithm predicted the rotation angle along a single axis with an error of < 0.5◦.

Tang, Mengjia↗

Automated tape-target centering based on template matching for construction measurement tasks using robotic total station

Robotic total stations have transformed surveying and construction mapping through precise, efficient, and automated measurements. These instruments integrate a theodolite, which measures horizontal and vertical angles, with an electronic distance measurement (EDM) unit to determine distances, allowing accurate 3D measurement of observable points. Traditionally, users manually aimed the total station at a target. Recent advancements in robotic motor control and integration of cameras now enable automatic rotation and aiming, typically requiring only a single operator to position the target. Automated aiming is commonly performed using retroreflector prisms, which reflect light back to the source with minimal scattering, enabling high-precision measurements over long distances. However, retroreflectors, especially those designed for 360 degree, can be expensive and impractical for certain applications. This paper presents an algorithm for automating the center detection of low-cost disposable tape targets using the total station's onboard camera and a template matching algorithm. The algorithm identifies the target's center pixel in the image, and the instrument is commanded to aim at that location. We evaluated the performance of this template-matching-based centering method under various distances, angles, lighting conditions, and field environments, comparing its results to both manual aiming and conventional automated aiming of tape targets. Manual aiming was used as the baseline operational reference in the absence of an independent ground-truth measurement. The proposed approach achieves target centering results comparable to the manual baseline. This method provides a cost-effective alternative for high-precision applications where retroreflector targets are constrained by budget or logistics.

Harrington, Joshua [ORNL]↗

Total X-Ray Emission from the LMC Observed with HaloSat

We constrain the global parameters of the Large Magellanic Cloud (LMC) by modeling the first soft X-ray (0.4–6.8 keV) observations of the entire LMC produced in a single pointing with moderate spectral resolution by the HaloSat CubeSat. These data are best fit with the sum of two thermal plasma components in collisional ionization equilibrium and a power law. We find cool (0.210 ± 0.014 keV) and hot (0.89 ± 0.14 keV) components. The total X-ray luminosity of the LMC is (1.08 ± 0.14) × 10{sup 39} erg s{sup −1}. X-ray binaries make up a large fraction of the emission with a luminosity of (6.0 ± 0.8) × 10{sup 38} erg s{sup −1}, followed by cool gas from superbubbles, supernovae, and diffuse emission with a luminosity of (3.0 ± 0.3) × 10{sup 38} erg s{sup −1}. The hot gas from star formation contributes the smallest fraction, with a luminosity of (1.9 ± 0.5) × 10{sup 38} erg s{sup −1}. We estimate the total volume of the cool gas to be between (0.2–1.2) × 10{sup 10} pc{sup 3} and the hot gas to be between (1.0–5) × 10{sup 7} pc{sup 3} for filling factors of f = 1 and 0.2. These volumes result in a total thermal energy for the cool gas between (1.4–3) × 10{sup 54} erg for electron densities of 0.017–0.04 cm{sup −3}, and a thermal energy for the hot gas between (1.7–4) × 10{sup 53} erg for electron densities of 0.12–0.3 cm{sup −3}. This yields cooling timescales for the cool and hot gas of (1.5–3) × 10{sup 8} yr and (1.8–6) × 10{sup 7} yr, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Close Major-merger Pairs at z = 0: Bulge-to-total Ratio and Star Formation Enhancement

We present a study of the bulge-to-total ratio (B/T) of a Ks-band-selected sample of 88 close major-merger pairs of galaxies (H-KPAIR), based on two-dimensional decompositions of SDSS r-band images with galfit. We investigate the dependence of the interaction-induced specific star formation rate enhancement (sSFR enh ) on the B/T ratio, and the effects of this dependence on the differences between star-forming galaxies (SFGs) in spiral+spiral (S+S) and spiral+elliptical (S+E) pairs. Of all the 132 spiral galaxies in H-KPAIR, the 44 in S+E pairs show higher B/T than those in the 44 S+S pairs, with means of B/T = 0.35 ± 0.05 and B/T = 0.26 ± 0.03, respectively. Furthermore, there is a strong negative dependence of sSFR enh on the B/T ratio, and only paired SFGs with B/T < 0.3 show significant (>5σ) enhancement. Paired SFGs in S+S pairs show a similar trend, and many disky SFGs (B/T < 0.1) in S+S pairs have strong sSFR enhancements (sSFR enh > 0.7 dex). For SFGs in S+E pairs, the sSFR has no clear B/T dependence, nor any significant enhancement in any B/T bin. Disky SFGs in S+S pairs show significant (>4σ) enhancement in molecular gas content (${M}_{{{\rm{H}}}_{2}}/{M}_{\mathrm{star}}$), while SFGs in S+E pairs have no such enhancement in any B/T bin. No significant enhancement of the total gas content (Mgas/Mstar) is found in any B/T bin for paired galaxies. The star formation efficiency of either the total gas (SFE gas = SFR/M gas ) or molecular gas (${\mathrm{SFE}}_{{{\rm{H}}}_{2}}=\mathrm{SFR}/{M}_{{{\rm{H}}}_{2}}$) does not depend on the B/T ratio. The only significant (> 4σ) SFE enhancement found for paired SFGs is the SFE gas for disky SFGs in S+S pairs.

79 ASTRONOMY AND ASTROPHYSICS↗

Flight-test results from two total temperature probes for air-data measurements up to 2014 K (3625 R)

An experimental temperature probe package containing a fluidic oscillator temperature probe and a shielded thermocouple temperature probe was tested during several X-15 flights. The X-15 flights provided greatly varying test conditions, including a wide range of rapidly changing total temperatures and Mach numbers which extended from subsonic to hypersonic speeds. Within restricted ranges of free-stream Mach number, free-stream unit weight flow, and local stagnation pressure, both probes yielded ramp outputs of temperature parallel to ramp inputs of free-stream total temperature. Within these ranges both probes were used to determine total temperature in the Mach 6 temperature environment. Because ambient temperature was known, both probes were used to estimate velocity and Mach number.

Nugent, J.↗

Correlation of total sound power and peak sideline OASPL from jet exhausts

An empirical analysis of jet noise is made for convergent exhaust nozzles. An engineering approach to the correlation of total sound power and miximum sideline overall sound pressure level (OASPL), at 200 ft, is presented for both subsonic and supersonic jets based on available data. Data correlation for subsonic jets shows no dependency of total sound power and maximum sideline OASPL on jet density. The analysis for supersonic jets results in a correlation parameter for jet total sound power consisting of the conventional Lighthill parameter modified by considerations of jet Mach number and jet acoustic velocity. Similar parameters also correlate the maximum sideline OASPL for supersonic jets.

Vonglahn, U. H.↗

Ionosphere total electron measurements as extracted from satellite tracking data

The Goddard Range and Range Rate System (GRARR) determines the range of a spacecraft by measuring the group delay of a modulated wave and the range rate by measuring the Doppler phase shift of the carrier. An analytical technique is presented for obtaining corrections and equivalent total electron content along the vertical, using VHF GRARR data and a radial model of the ionosphere. The results of computation for a representative pass are given, and estimated accuracy is discussed from a statistical view point. Using VHF GRARR data and a radial model of the ionosphere. The results of computation for a representative pass are given, and estimated accuracy is discussed from a statistical view point. Using GRARR range, range rate, and angle tracking data from Explorer 41, values of total electron content on the order of 10 to the 17th to 10 to the 18th power (electrons/sq m) were obtained. These values agree with estimates of the total electron content from ionospheric profiles using f sub o F sub 2 predict data.

Murray, C. W., Jr.↗

Estimation of total ozone from satellite measurements of backscattered ultraviolet earth radiance.

Total ozone is estimated from Nimbus IV satellite measurements of the attenuation of backscattered radiances at wavelengths between 3100 and 3400 A. A measurement of the backscattered radiance at 3800 A, outside the ozone absorption band, is used to determine an equivalent Lambert albedo for the cloud-ground-haze surface viewed by the instrument. The measured relative attenuation at two wavelengths is compared with such values precomputed for a series of standard ozone profiles and corrected for the equivalent Lambert albedo. Total ozone is obtained by interpolation. Two alternative methods are used to assign an equivalent Lambert albedo at the absorbing wavelengths. Total ozone values estimated by these methods are compared with the Dobson (ground-truth) data by linear regression. The available evidence suggests that the true standard error of the satellite data may be 0.015 atm-cm or less for solar zenith angles smaller than 60 deg.

Mateer, C. L.↗

Correlation of total sound power and peak sideline OASPL from jet exhausts.

An empirical analysis of jet noise is made for convergent exhaust nozzles. This study, conducted at the Lewis Research Center, presents an engineering approach to the correlation of total sound power and maximum sideline OASPL (at 200 ft) for both subsonic and supersonic jets based on available data. Data correlation for subsonic jets shows no dependency of total sound power and maximum sideline OASPL on jet density. The analysis for supersonic jets results in a correlation parameter for jet total sound power consisting of the conventional Lighthill parameter modified by considerations of jet Mach number and jet acoustic velocity. Similar parameters also correlate the maximum sideline OASPL for supersonic jets.

Von Glahn, U. H.↗