Search NASA⌕ Search

SEARCH · Search NASA

Results for “Trapped Ion Frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Ion-molecule collision frequencies in gases determined by phase coherent pulsed ICR.

The transient method considered is analogous to similar phase coherence experiments performed in NMR and plasma physics. Using a pulsed ion cyclotron resonance (ICR) spectrometer equipped with a trapped ion analyzer cell, gaseous ions are formed by a pulse of an electron beam and then trapped in the cell by the combined effects of the magnetic and electrostatic fields. The results obtained in the experiments indicate that the classical mobility treatment of Wannier (1953) is helpful in the understanding of collision frequencies under the considered conditions.

Lieder, C. A.↗

NASA Tech Briefs, December 2005

Topics covered include: Video Mosaicking for Inspection of Gas Pipelines; Shuttle-Data-Tape XML Translator; Highly Reliable, High-Speed, Unidirectional Serial Data Links; Data-Analysis System for Entry, Descent, and Landing; Hybrid UV Imager Containing Face-Up AlGaN/GaN Photodiodes; Multiple Embedded Processors for Fault-Tolerant Computing; Hybrid Power Management; Magnetometer Based on Optoelectronic Microwave Oscillator; Program Predicts Time Courses of Human/ Computer Interactions; Chimera Grid Tools; Astronomer's Proposal Tool; Conservative Patch Algorithm and Mesh Sequencing for PAB3D; Fitting Nonlinear Curves by Use of Optimization Techniques; Tool for Viewing Faults Under Terrain; Automated Synthesis of Long Communication Delays for Testing; Solving Nonlinear Euler Equations With Arbitrary Accuracy; Self-Organizing-Map Program for Analyzing Multivariate Data; Tool for Sizing Analysis of the Advanced Life Support System; Control Software for a High-Performance Telerobot; Java Radar Analysis Tool; Architecture for Verifiable Software; Tool for Ranking Research Options; Enhanced, Partially Redundant Emergency Notification System; Close-Call Action Log Form; Task Description Language; Improved Small-Particle Powders for Plasma Spraying; Bonding-Compatible Corrosion Inhibitor for Rinsing Metals; Wipes, Coatings, and Patches for Detecting Hydrazines; Rotating Vessels for Growing Protein Crystals; Oscillating-Linear-Drive Vacuum Compressor for CO2; Mechanically Biased, Hinged Pairs of Piezoelectric Benders; Apparatus for Precise Indium-Bump Bonding of Microchips; Radiation Dosimetry via Automated Fluorescence Microscopy; Multistage Magnetic Separator of Cells and Proteins; Elastic-Tether Suits for Artificial Gravity and Exercise; Multichannel Brain-Signal-Amplifying and Digitizing System; Ester-Based Electrolytes for Low-Temperature Li-Ion Cells; Hygrometer for Detecting Water in Partially Enclosed Volumes; Radio-Frequency Plasma Cleaning of a Penning Malmberg Trap; Reduction of Flap Side Edge Noise - the Blowing Flap; and Preventing Accidental Ignition of Upper-Stage Rocket Motors.

Source record↗

Buffer Gas Experiments in Mercury (Hg+) Ion Clock

We describe the results of the frequency shifts measured from various buffer gases that might be used as a buffer gas to increase the loading efficiency and cooling of ions trapped in a small mercury ion clock. The small mass, volume and power requirement of space clock precludes the use of turbo pumps. Hence, a hermetically sealed vacuum system, incorporating a suitable getter material with a fixed amount of inert buffer gas may be a practical alternative to the groundbased system. The collision shifts of 40,507,347.996xx Hz clock transition for helium, neon and argon buffer gases were measured in the ambient earth magnetic field. In addition to the above non-getterable inert gases we also measured the frequency shifts due to getterable, molecular hydrogen and nitrogen gases which may be used as buffer gases when incorporated with a miniature ion pump. We also examined the frequency shift due to the low methane gas partial pressure in a fixed higher pressure neon buffer gas environment. Methane gas interacted with mercury ions in a peculiar way as to preserve the ion number but to relax the population difference in the two hyperfine clock states and thereby reducing the clock resonance signal. The same population relaxation was also observed for other molecular buffer gases (N H ,) but at much reduced rate.

mercury ion clock↗

Probing many-body localization on a noisy quantum computer

A disordered quantum system of interacting particles exhibits localized behavior when the disorder is large compared to the interaction strength. Studying this phenomenon on a quantum computer with no, or limited, error correction is challenging because even weak coupling to a thermal environment destroys most signatures of localization. Fortunately, spectral functions of local operators are known to contain features that can survive the presence of noise. In these spectra, discrete peaks and a soft gap at low frequencies compared to the thermal phase indicate localization. Here, we present the computation of spectral functions on a trapped-ion quantum computer for a one-dimensional Heisenberg model with disorder. Further, we design an error-mitigation technique which is effective at removing the noise from the measurement allowing clear signatures of localization to emerge as the disorder increases. Furthermore, we show that spectral functions can serve as a robust and scalable diagnostic of many-body localization on current and future generations of quantum computers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anomalous resistivity on auroral field lines

Consideration is given to a possible explanation for the one-dimensional anomalous resistivity and breakdown of runaway acceleration observed in the auroral zones. It is shown that under conditions existing along auroral field lines, where the cyclotron frequency is greater than the plasma frequency and density fluctuations exceed 0.25, trapping of a major portion of the electron distribution function by large-amplitude ion cyclotron waves can inhibit the free acceleration of runaways and act to violate the conservation of the first adiabatic invariant for electrons above a certain threshold velocity. Particle simulations combining the effects of finite ion cavities and pitch angle scattering at the anomalous Doppler resonance are then presented which demonstrate the formation of a runaway distribution upon the application of a constant dc field and the effects of the instability at the anomalous Doppler resonance in preventing it. The necessity for further large-scale macrophysics simulations to gain a fuller understanding of the total system dynamics is pointed out.

Rowland, H. L.↗

Indium Single-Ion Frequency Standard

A single laser-cooled indium ion is a promising candidate for an ultimate resolution optical time or frequency standard. It can be shown that single ions from group IIIA of the periodic table (indium, thallium, etc.) can have extremely small systematic errors. In addition to being free from Doppler, transit-time and collisional shifts, these ions are also quite insensitive to perturbations from ambient magnetic and electric fields (mainly due to the use of a J=0-0 transition for spectroscopy). Of all group IIIA ions, indium seems to be the most practical, since it is heavy enough to have a tolerable intercombination cooling transition rate and (unlike thallium) has transitions which are easily accessible with frequency multiplied continuous-wave lasers. A single indium ion standard has a potential inaccuracy of one part in 10(exp 18) for integration times of 10(exp 6) seconds. We have made substantial progress during the grant period in constructing a frequency standard based upon a single indium ion. At the beginning of the grant period, single indium ions were being successfully trapped, but the lasers and optical systems were inadequate to achieve the desired goal. We have considerably improved the stability of the dye laser used to cool the ions and locked it to a molecular resonance line, making it possible to observe stable cooling-line fluorescence from a single indium ion for reasonable periods of time, as required by the demands of precision spectroscopy. We have substantially improved the single-ion fluorescence signal with significant benefits for the detection efficiency of forbidden transitions using the 'shelving' technique. Finally, we have constructed a compact, efficient UV 'clock' laser and observed 'clock' transitions in single indium ions using this laser system. We will elaborate on these accomplishments.

Nagourney, Warren↗

In situ detection of RF breakdown on microfabricated surface ion traps

We report microfabricated surface ion traps are a principal component of many ion-based quantum information science platforms. The operational parameters of these devices are pushed to the edge of their physical capabilities as the experiments strive for increasing performance. When the applied radio-frequency (RF) voltage is increased excessively, the devices can experience damaging electric discharge events known as RF breakdown. We introduce two novel techniques for in situ detection of RF breakdown, which we implemented while characterizing the breakdown threshold of surface ion traps produced at Sandia National Laboratories. In these traps, breakdown did not always occur immediately after increasing the RF voltage, but often minutes or even hours later. This result is surprising in the context of the suggested mechanisms for RF breakdown in vacuum. Additionally, the extent of visible damage caused by breakdown events increased with the applied voltage. To minimize the probability for damage when RF power is first applied to a device, our results strongly suggest that the voltage should be ramped up over the course of several hours and monitored for breakdown.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Trapped-ion entangling gates with bichromatic pair of microwave fields and magnetic field gradient

A trapped-ion quantum logic gate and a method of operating the trapped-ion quantum logic gate are provided. The trapped-ion quantum logic gate includes at least one ion having two internal states and forming a qubit having a qubit transition frequency ω 0 0, a magnetic field gradient, and two microwave fields. Each of the two microwave fields has a respective frequency that is detuned from the qubit transition frequency ω 0 by frequency difference δ. The at least one ion has a Rabi frequency Ω μ due to the two microwave fields and a Rabi frequency Ω g due to the magnetic field gradient. The method includes applying the magnetic field gradient and the two microwave fields to the at least one ion such that a quantity Ω g /δ is in a range between zero and 5×10 −2 .

Sutherland, Robert Tyler↗

High-Fidelity Bell-State Preparation with 40 Ca + Optical Qubits

Entanglement generation in trapped-ion systems has relied thus far on two distinct but related geometric phase gate techniques: Mølmer-Sørensen and light-shift gates. We recently proposed a variant of the light-shift scheme where the qubit levels are separated by an optical frequency [B. C. Sawyer and K. R. Brown, Phys. Rev. A 103, 022427 (2021)]. Here, in this study, we report an experimental demonstration of this entangling gate using a pair of 40 Ca + ions in a cryogenic surface-electrode ion trap and a commercial, high-power, 532 nm Nd:YAG laser. Generating a Bell state in 35 μs, we directly measure an infidelity of 6(3) × 10 −4 without subtraction of experimental errors. The 532 nm gate laser wavelength suppresses intrinsic photon scattering error to ∼1 × 10 −5 .

Clark, Craig R.↗

Review of the High Performance Antiproton Trap (HiPAT) Experiment at the Marshall Space Flight Center

The significant energy density of matter-antimatter annihilation is attractive to the designers of future space propulsion systems, with the potential to offer a highly compact source of power. Many propulsion concepts exist that could take advantage of matter-antimatter reactions, and current antiproton production rates are sufficient to support basic proof-of-principle evaluation of technology associated with antimatter- derived propulsion. One enabling technology for such experiments is portable storage of low energy antiprotons, allowing antiprotons to be trapped, stored, and transported for use at an experimental facility. To address this need, the Marshall Space Flight Center's Propulsion Research Center is developing a storage system referred to as the High Performance Antiproton Trap (HiPAT) with a design goal of containing 10(exp 12) particles for up to 18 days. The HiPAT makes use of an electromagnetic system (Penning- Malmberg design) consisting of a 4 Telsa superconductor, high voltage electrode structure, radio frequency (RF) network, and ultra high vacuum system. To evaluate the system normal matter sources (both electron guns and ion sources) are used to generate charged particles. The electron beams ionize gas within the trapping region producing ions in situ, whereas the ion sources produce the particles external to the trapping region and required dynamic capture. A wide range of experiments has been performed examining factors such as ion storage lifetimes, effect of RF energy on storage lifetime, and ability to routinely perform dynamic ion capture. Current efforts have been focused on improving the FW rotating wall system to permit longer storage times and non-destructive diagnostics of stored ions. Typical particle detection is performed by extracting trapped ions from HiPAT and destructively colliding them with a micro-channel plate detector (providing number and energy information). This improved RF system has been used to detect various plasma modes for both electron and ion plasmas in the two traps at MSFC, including axial, cyclotron, and diocotron modes. New diagnostics are also being added to HiPAT to measure the axial density distribution of the trapped cloud to match measured RF plasma modes to plasma conditions.

Pearson, J. B.↗

Precise $\textit{Q}$-value measurements of 112,113 Ag and 115 Cd with the Canadian Penning trap for evaluation of potential ultralow $\textit{Q}$-value $\textit{β}$ decays

Background: An ultralow $\textit{Q}$-value $\textit{β}$ decay can occur from a parent nuclide to an excited nuclear state in the daughter such that $Q_{\text{UL}}$ 1 keV. These decay processes are of interest for nuclear $\textit{β}$-decay theory and as potential candidates in neutrino mass determination experiments. To date, only one ultralow $\textit{Q}$-value $\textit{β}$ decay has been observed—that of 115 In with $Q_β$ = 147(10) eV. A number of other potential candidates exist, but improved mass measurements are necessary to determine if these decay channels are energetically allowed and, in fact, ultralow. Purpose: To perform precise $\textit{β}$-decay $\textit{Q}$-value measurements of 112,113 Ag and 115 Cd and to use them in combination with nuclear energy level data for the daughter isotopes 112,113 Cd and 115 In to determine if the potential ultralow $\textit{Q}$-value $\textit{β}$-decay branches of 112,113 Ag and 115 Cd are energetically allowed and 1 keV. Method: The Canadian Penning Trap at Argonne National Laboratory was used to measure the cyclotron frequency ratios of singly charged 112,113 Ag and 115 Cd ions with respect to their daughters 112,113 Cd and 115 In. From these measurements, the ground-state to ground-state $\textit{β}$-decay $\textit{Q}$ values were obtained. Results: The 112 Ag → 112 Cd, 113 Ag → 113 Cd, and 115 Cd → 115 In $\textit{β}$-decay $\textit{Q}$ values were measured to be $Q_β$( 112 Ag) = 3990.16(22) keV, $Q_β$( 113 Ag) = 2085.7(4.6) keV, and $Q_β$( 115 Cd) = 1451.36(34) keV. These results were compared to energies of excited states in 112 Cd at 3997.75(14) keV, 113 Cd at 2015.6(2.5) and 2080(10) keV, and 115 In at 1448.787(9) keV, resulting in precise $Q_{\text{UL}}$ values for the potential decay channels of –7.59(26) keV, 6(11) keV, and 2.57(34) keV, respectively. Conclusion: The potential ultralow $\textit{Q}$-value decays of 112 Ag and 115 Cd have been ruled out. 113 Ag is still a possible candidate until a more precise measurement of the 2080(10) keV, 1/2+ state of 113 Cd is available. In the course of this work we have found the ground state mass of 113 Ag reported in the 2020 Atomic Mass Evaluation [Wang et al., Chin. Phys. C 45, 030003 (2021)] to be lower than our measurement by 69(17) keV (a 4σ discrepancy).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Normal modes, rotational inertia, and thermal fluctuations of trapped ion crystals

The normal modes of a trapped ion crystal are derived using an approach based on the Hermitian properties of the system’s dynamical matrix. This method is equivalent to the standard Bogoliubov method, but for classical systems it is arguably simpler and more general in that canonical coordinates are not necessary. The theory is developed for stable, unstable, and neutrally-stable systems. The method is then applied to ion crystals in a Penning trap. Reduced eigenvalue problems for the case of large applied magnetic field are developed, for which the spectrum breaks into E x B drift modes, axial modes, and cyclotron modes. Thermal fluctuation levels in these modes are analyzed and shown to be consistent with the Bohr-van-Leeuwen theorem, provided that neutrally-stable modes associated with crystal rotations are included in the analysis. An expression for the rotational inertia of the crystal is derived, and a magnetic contribution to this inertia, which dominates in large magnetic fields, is described. An unusual limit is discovered for the special case of spherically-symmetric confinement, in which the rotational inertia does not exist and changes in angular momentum leave the rotation frequency unaffected.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Small Mercury Ion Clock for On-board Spacecraft Navigation

I.Small Ion Clock Approach and Heritage: a) No lasers, uwave cavities, cryogenics, atomic beams, etc. b) Ions are electrically shuttled between separate optical and microwave traps. II. Each trap is optimized for its task: quadrupole for optical state selection; multi-pole for microwave clock. a) Very good stability shown in USNO. Timescale running "open loop." III. "Open loop" operation means no self-measurements of frequency offsets: (Zeeman, ion temperature,... etc.) a) Fewer parts and procedures, produces stable output continuously. IV. Ion clock is not so sensitive to temperature fluctuations a) Measured u:nshielded temperature coefficient of few 10(exp -15) per C. b) No bulky temperature isolation needed.

Prestage, John D.↗

A Dual Source Ion Trap Mass Spectrometer for the Mars Organic Molecule Analyzer of ExoMars 2018

We present details on the objectives, requirements, design and operational approach of the core mass spectrometer of the Mars Organic Molecule Analyzer (MOMA) investigation on the 2018 ExoMars mission. The MOMA mass spectrometer enables the investigation to fulfill its objective of analyzing the chemical composition of organic compounds in solid samples obtained from the near surface of Mars. Two methods of ionization are realized, associated with different modes of MOMA operation, in a single compact ion trap mass spectrometer. The stringent mass and power constraints of the mission have led to features such as low voltage and low frequency RF operation [1] and pulse counting detection.

Brickerhoff, William B.↗

Photon-mediated entanglement scheme between a ZnO semiconductor defect and a trapped Yb ion

We propose an optical scheme to generate an entangled state between a trapped ion and a solid state donor qubit through which-path erasure of identical photons emitted from the two systems. The proposed scheme leverages the similar transition frequencies between In donor bound excitons in ZnO and the 2 P 1/2 to 2 S 1/2 transition in Yb+. The lifetime of the relevant ionic state is longer than that of the ZnO system by a factor of 6, leading to a mismatch in the temporal profiles of emitted photons. A detuned cavity-assisted Raman scheme weakly excites the donor with a shaped laser pulse to generate photons with a 0.99 temporal overlap to the Yb+ emission and partially shift the emission of the defect toward the Yb+ transition. Here, the remaining photon shift is accomplished via the dc Stark effect. We show that an entanglement rate of 2.1 × 10 4 s –1 and an entanglement fidelity of 94% can be attained using a weak excitation scheme with reasonable parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prospects for atomic frequency standards

The potentialities of different atomic frequency standards which are not yet into field operation, for most of them, but for which preliminary data, obtained in laboratory experiments, give confidence that they may improve greatly the present state of the art are described. The review will mainly cover the following devices: (1) cesium beam frequency standards with optical pumping and detection; (2) optically pumped rubidium cells; (3) magnesium beam; (4) cold hydrogen masers; and (5) traps with stored and cooled ions.

Audoin, C.↗

Keynote address: The past, present, and future of atomic time

The early history of atomic time and frequency standards is reviewed. The most accurate and stable present standards are described. Prospective future improvements are discussed, particularly those with laser cooling and with trapped ions and atoms.

Ramsey, Norman F.↗