Search NASA⌕ Search

SEARCH · Search NASA

Results for “ULTRAVIOLET FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

LIMS Instrument Package (LIP) balloon experiment: Nimbus 7 satellite correlative temperature, ozone, water vapor, and nitric acid measurements

The Limb Infrared Monitor of the Stratosphere (LIMS) LIP balloon experiment was used to obtain correlative temperature, ozone, water vapor, and nitric acid data at altitudes between 10 and 36 kilometers. The performance of the LIMS sensor flown on the Nimbus 7 Satellite was assessed. The LIP consists of the modified electrochemical concentration cell ozonesonde, the ultraviolet absorption photometric of ozone, the water vapor infrared radiometer sonde, the chemical absorption filter instrument for nitric acid vapor, and the infrared radiometer for nitric acid vapor. The limb instrument package (LIP), its correlative sensors, and the resulting data obtained from an engineering and four correlative flights are described.

Lee, R. B., III↗

Hubble Space Telescope observations of Mars

Hubble Space Telescope (HST) afforded the possibility of resolving features as small as 100 km on the Martian surface even when it is at the far point of its orbit. Therefore it is ideally suited for monitoring seasonal changes on the red planet. The objectives research include: the study of Martian dust storms; use of images obtained through different filters to study the spectral reflectance of regions on the Martian surface; use of ultraviolet images and spectra to measure the amount of ozone in the planet's atmosphere as a function of location of the planet; use of images to study changes in the albedo of the Mars surface; and use of Planetary Camera images to study Martian clouds and to measure the opacity of the atmosphere.

James, Philip B.↗

Global pictures of the ozone field from high altitudes from DE-I

Detailed synoptic views of the column ozone field can be obtained by the Spin-Scan Ozone Imager (SOI) (Keating et al., 1981) aboard the Dynamics Explorer I satellite. The eccentric polar orbit with an apogee altitude of 23,000 km allows high resolution global-scale images to be obtained within 12 minutes, and allows regions to be viewed for long periods of time. At perigee, a pixel size of nadir measurements of 3 km is possible, and measurements are determined using the backscattered ultraviolet technique. A wavelength measurement of 317.5 nm is used as there are limitations in filter locations and it allows comparison with Nimbus 7 SBUV/TOMS data. Consideration of the reflectivities of this data aids in checking the SOI data reduction algorithm. SOI data show short-term (less than one day) variations in the observed ozone field, and a negative correlation (greater than 0.9) between ozone and tropopause heights. It is expected, due to this correlation, that SOI data will aid in understanding the time evolution of dynamics near the tropopause.

Keating, G. M.↗

Electron- and Photon-stimulated Desorption of Alkali Atoms from Lunar Sample and a Model Mineral Surface

We report recent results on an investigation of source mechanisms for the origin of alkali atoms in the tenuous planetary atmospheres, with focus on non-thermal processes (photon stimulated desorption (PSD), electron stimulated desorption (ESD), and ion sputtering). Whereas alkaline earth oxides (MgO, CaO) are far more abundant in lunar samples than alkali oxides (Na2O, K2O), the atmosphere of the Moon contains easily measurable concentrations of Na and K, while Ca and Mg are undetected there; traces of Ca have recently been seen in the Moon's atmosphere (10-3 of Na). The experiments have included ESD, PSD and ion sputtering of alkali atoms from model mineral surface (amorphous SiO2) and from a lunar basalt sample obtained from NASA. The comparison is made between ESD and PSD efficiency of monovalent alkalis (Na, K) and divalent alkaline earths (Ba, Ca).The ultrahigh vacuum measurement scheme for ESD and PSD of Na atoms includes a highly sensitive alkali metal detector based on surface ionization, and a time-of-flight technique. For PSD measurements, a mercury arc light source (filtered and chopped) is used. We find that bombardment of the alkali covered surfaces by ultraviolet photons or by low energy electrons (E>4 eV) causes desorption of hot alkali atoms. This results are consistent with the model developed to explain our previous measurements of sodium desorption from a silica surface and from water ice: electron- or photon-induced charge transfer from the substrate to the ionic adsorbate causes formation of a neutral alkali atom in a repulsive configuration, from which desorption occurs. The two-electron charge transfer to cause desorption of divalent alkaline eath ions is a less likely process.The data support the suggestion that PSD by UV solar photons is a dominant source process for alkalis in the tenuous lunar atmosphere.

Yakshinskiy, B. V.↗

Daily Global Mapping of Mars Ozone Column Abundances with MARCI UV Band Imaging

Since November of 2006, The Mars Color Imager (MARCI) onboard the Mars Reconnaissance Orbiter (MRO) has obtained multiple-filter daily global images of Mars centered upon a local time (LT) of 3 pm. Ultraviolet imaging bands placed within (260 nm) and longward (320 nm) of Hartley band (240-300 nm) ozone (O3) absorption support retrievals of atmospheric ozone columns, with detection limits (approximately 1 micrometer-atm) appropriate to mapping elevated O3 abundances at low latitudes around Mars aphelion, and over mid-to-high latitudes during fall/winter/spring seasons. MARCI O3 maps for these regions reveal the detailed spatial (approximately 1 deg lat/long, for 8 x 8 pixel binned resolution) and temporal (daily, with substantial LT coverage at pole) behaviors of water vapor saturation conditions that force large variations in water vapor photolysis products (HOx-OH, HO2, and H) responsible for the catalytic destruction of O3 in the Mars atmosphere. A detailed description of the MARCI O3 data set, including measurement and retrieval characteristics, is provided in conjunction with comparisons to Mars Express SPICAM ozone measurements (Perrier, S. et al. [2006]. J. Geophys. Res. (Planets) 111) and LMD GCM simulated O3 abundances (Lefevre, F. [2004]. J. Geophys. Res. (Planets) 109). Presented aspects of the MARCI ozone mapping data set include aphelion increases in low latitude O3, dynamically evolving high latitude O3 maxima associated with planetary waves and weather fronts during northern early spring, and distinctive winter/spring O3 and CO increases within the Hellas Basin associated with transport of condensation enhanced south polar air mass. Comparisons of coincident MARCI measurements and LMD simulations for ice cloud and O3 columns are considered in the context of potential heterogeneous photochemical processes (Lefevre, F. [2008]. Nature 454, 971-975), which are not strongly evidenced in the MARCI observations. Modest interannual variations are exhibited, most notably a 20% reduction in aphelion low latitude O3 columns following the 2007 perihelic global dust storm.

Clancy, R. Todd↗

PACE OCI Flight Unit Pre-launch Spectral Characterization

The Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission [1] will extend and improve the data record of NASA’s satellite observations of global ocean biology, aerosols, and clouds. The Ocean Color Instrument (OCI) is the primary sensor on-board the PACE platform [2]. The OCI is a scanning radiometer with hyperspectral coverage from the ultraviolet (UV) to the near infrared (NIR) wavelength range and a fiber-coupled multiband filter spectrograph in the short-wave infrared (SWIR) spectral region. The OCI Flight Unit completed system level testing in November 2022 at the Goddard Space Flight Center (GSFC). This paper presents the spectral characterization and performance of the OCI Flight Unit. The OCI Flight spectral performance was determined to be within design specifications and the characterization was measured within specified uncertainties.

PACE↗

Pace Oci Flight Unit Pre-Launch Spectral Characterization

The Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission [1] will extend and improve the data record of NASA’s satellite observations of global ocean biology, aerosols, and clouds. The Ocean Color Instrument (OCI) is the primary sensor on-board the PACE platform [2]. The OCI is a scanning radiometer with hyperspectral coverage from the ultraviolet (UV) to the near infrared (NIR) wavelength range and a fiber-coupled multiband filter spectrograph in the short-wave infrared (SWIR) spectral region. The OCI Flight Unit completed system level testing in November 2022 at the Goddard Space Flight Center (GSFC). This paper presents the spectral characterization and performance of the OCI Flight Unit. The OCI Flight spectral performance was determined to be within design specifications and the characterization was measured within specified uncertainties.

PACE↗

Global ozone long-term trends from satellite measurements and the response to solar activity variations

Analysis of global ozone variations for the period April 1970 to December 1975 was performed by using the reprocessed Nimbus 4 backscattered ultraviolet (BUV) measurements of total ozone. A correlation coefficient of 0.97 is found between the 6-month running mean of global mean total ozone (filtered for mean semiannual, annual, and quasibiennial variations) and the 10.7-cm solar activity index. Correcting ozone for a time-dependent latitudinal bias relative to Dobson ozone measurements reduces to 2-3% the global mean ozone variation over the solar cycle. The solar ultraviolet variability required in a one-dimensional time-dependent radiative photochemical model to account for the observed ozone variation appears to be consistent with recent solar UV observations.

Keating, G. M.↗

Observations of the extreme ultraviolet nightglow

An extreme ultraviolet telescope system was flown on an Aerobee 170 rocket from the White Sands Missile Range on Oct. 22, 1971. Measurements of extreme ultraviolet radiation from the night sky were made with a set of Parylene, aluminum, and tin filters behind a grazing incidence concentrator. If the aluminum and tin filter data are interpreted as being due to only the He I 584-A and He II 304-A lines, the nightglow flux at 25 deg zenith angle and 270 deg azimuth angle at 180-km altitude was I(584) = 4.4 plus or minus 1.9 R and I(304) = 1.3 plus or minus 0.5 R.

Riegler, G. R.↗

Isoelectric focusing in space

The potential of space electrophoresis is conditioned by the fact that all electrophoretic techniques require the suppression of gravity-caused convection. Isoelectric focusing (IEF) is a powerful variant of electrophoresis, in which amphoteric substances are separated in a pH gradient according to their isoelectric points. A new apparatus for large scale IEF, utilizing a recycling principle, has been developed. In the ground-based prototype, laminar flow is provided by a series of parallel filter elements. The operation of the apparatus is monitored by an automated array of pH and ultraviolet absorption sensors under control of a desk-top computer. The apparatus has proven to be useful for the purification of a variety of enzymes, snake venom proteins, peptide hormones, and other biologicals, including interferon produced by genetic engineering techniques. In planning for a possible space apparatus, a crucial question regarding electroosmosis needs to be addressed To solve this problem, simple focusing test modules are planned for inclusion in an early Shuttle flight.

Bier, M.↗

On the X-ray emitting boundary layer of the dwarf nova VW Hydri

The temperature and luminosity of the boundary layer of VW Hyi are constrained to kT(BL) of about 10.5 eV, and L(BL) of about 6 x 10 to the 32nd (d/65 pc)squared ergs/sec. This is based on Voyager far- and extreme-ultraviolet spectrophotometry and a measurement of the column density of neutral hydrogen, combined with Exosat LE filter observations. Results are compared with the accretion-disk luminosity found by Polidan et al. (1990) using concurrent optical, IUE, and Voyager spectrophotometric observations. The value of zeta is found to be about 0.04, although theoretical predictions show comparable luminosities at the boundary layer and the accretion disk - zeta is identical to L(BL)/L(disk), which is about 1 - unless the white dwarf rotates very rapidly. Severe contamination of filter observations due to light from the inner accretion disk is also found. This contamination had previously been understood as a result of the luminous ultrasoft boundary layer.

Mauche, Christopher W.↗

Measuring Hydrogen Plumes With Raman Lidar

Prototype Raman lidar system measures concentration of hydrogen gas in atmosphere as function of position, with range resolution of 3 ft over 3,000 ft. Sensitive to concentrations smaller than 0.5 percent, 10 times below minimum flammable concentration. Pulsed ultraviolet laser beam excites Raman emissions from molecules to be detected. Backscattered light collected by telescope, filtered at appropriate wavelengths, and sent to photodetectors. Developed for use as safety monitor, and to study dispersion of hydrogen gas leaking into atmosphere.

Caputo, Bernard↗

The Retrieval of Ozone Profiles from Limb Scatter Measurements: Results from the Shuttle Ozone Limb Sounding Experiment

Two instruments were flown on shuttle flight STS-87 to test a new technique for inferring the ozone vertical profile using measurements of scattered sunlight from the Earth's limb. The instruments were an ultraviolet imaging spectrometer designed to measure ozone between 30 and 50 km, and a multi-filter imaging photometer that uses 600 nm radiances to measure ozone between 15 km and 35 km. Two orbits of limb data were obtained on December 2, 1997. For the scans analyzed the ozone profile was measured from 15 km to 50 km with approximately 3 km vertical resolution. Comparisons with a profile from an ozonesonde launched from Ascension Island showed agreement mostly within +/- 5%. The tropopause at 15 km was clearly detected.

McPeters, Richard D.↗

Calibration of the Shuttle Ozone Limb Sounding Experiment (SOLSE) and the Limb Ozone Retrieval Experiment (LORE)

The calibration and characterization of two new instruments designed to retrieve ozone profiles into the lower stratosphere will be presented. These instruments will fly as a single payload on the Space Shuttle Columbia currently scheduled to lift off July 11, 2002. The purpose of SOLSE (Shuttle Ozone Limb Sounding Experiment) and LORE (Limb Ozone Retrieval Experiment) is to provide a thorough test of the limb ozone retrieval technique, which is being employed on several satellite instruments currently deployed or planned for deployment in the near future. OSIRIS (Optical Spectrograph and Infrared Imager System) and SCIAMACHY (Scanning Imaging Absorption Spectrometer for Atmospheric Chartography) are already in orbit, while OMPS (the Ozone Mapping and Profiler Suite) is planned as the primary US ozone monitoring instrument in the next decade.. SOLSE is a Czerny-Turner spectrograph utilizing a 1k x 1k cooled CCD at the focal plane and covering the spectral range of 310-380 nm in the ultraviolet and 535-865 nm in the visible to near infrared. LORE is a 5 channel filter radiometer with center band wavelengths of 322, 350, 603, 675, and 1000 nm. The focus of this paper will be on measurements of the SOLSE spectrograph performance in the limb-viewing configuration including stray light rejection, spatial and spectral resolution and absolute radiometric response.

Janz, S. J.↗

Rapid Identification of GRB Afterglows with Swift/UVOT

As part of the automated response to a new gamma-ray burst (GRB), the Ultraviolet and Optical Telescope (UVOT) instrument on Swift starts a 200-second exposure with the V filter within approximately 100 seconds of the BAT burst trigger. The instrument searches for sources in a 8' x 8' region, and sends the list of sources and a 160" x 160" sub-image centered on the burst position to the ground via Tracking and Data Relay Satellite System (TDRSS). These raw products and additional products calculated on the ground are then distributed through the GCN within a few minutes of the trigger. We describe the sensitivity of these data for detecting afterglows, summarize current results, and outline plans for rapidly distributing future detections.

Marshall, F. E.↗

A review of some aspects of inferring the ozone profile by inversion of ultraviolet radiance measurements

The mathematical inversion of light-scattering observations to obtain the atmospheric ozone profile is discussed in terms of the filtering properties of the physical and mathematical processes for different spatial scales. Within this context, it is shown that the physical process of scattering acts as a low pass filter; which transfers large-scale profile information efficiently to radiance observations but very strongly attenuates small- or fine-scale profile information. To avoid domination of the mathematical inversion by the random error of radiance measurements, an equivalent spatial-scale filtering in the inversion procedure is essential. The available evidence suggests that mathematical inversion to obtain the low level ozone profile below 25 to 30 km is either inferior to or no better than the statistical estimation of the profile using total ozone as predictor. However, inversion profiles for high level ozone above 25 to 30 km appear to have moderately good accuracy.

Mateer, C. L.↗

Tunable UV Filters

This report describes an investigation intended to determine the practical short wavelength limit for Fabry-Perot etalons operating in the far ultraviolet. This portion of the investigation includes a design study of multilayer dielectric reflector coatings that would be required by such an etalon. Results of the study indicate that etalons may be made to operate at wavelengths as short as 121 nm.

Bruner, Marilyn E.↗