Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ultraviolet lasers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Quantum efficiency measurements for several waveshifter coatings in the extreme vacuum ultraviolet

Quantum efficiency measurements are given for coronene and liumogen coatings designed to enhance UV sensitivity for silicon charge coupled device imaging detectors. Coatings on quartz and on UDT PIN 10DP photodiodes were tested. The wavelength range extended from 153.7 to 50.0 nm in the vacuum ultraviolet. Similar measurements were made for coronene, liumogen, and stilbene-3 laser dye films on quartz disks relative to sodium salicylate. Sodium salicylate and coronene are the most efficient waveshifters down to 50 nm so far observed. Coronene's fairly constant quantum efficiency over such a wide wavelength range into the far VUV makes it a useful waveshifter for UV and VUV applications.

Butner, C. L.↗

Dynamic interferometer alignment and its utility in UV Fourier transform spectrometer systems

Dynamic alignment has been demonstrated as a practical approach to alignment maintenance for systems in the infrared region of the spectrum. On the basis of work done by OPTRA, this technique was introduced in commercial Fourier transform spectrometer systems in 1982 and in various forms is now available from a number of manufacturers. This paper reports on work by OPTRA to extend the basic technique to systems operating in the ultraviolet. In addition, this paper reports the preliminary results of the development of an alignment system using a laser diode in place of a gas laser normally found in dynamic alignment systems. A unique optical system and spatial heterodyne technique allows for achievement of a metrology system with characteristics that fully satisfy the requirements of an ultraviolet spectrometer system.

Dorval, Rick K.↗

The internal state distribution of CN radicals produced in the photolysis of HC2CN and CH3CN

The energy partitioning in CN radicals produced by the vacuum ultraviolet photodissociation of HC2CN and CH3CN is studied by means of laser-induced fluorescence of the B-X transition. Experiments are performed in two collision regimes: (1) in the low-collision number regime, the energy partitioning in CN(X) is measured; (2) in the high-collision number regime, the formation of CN(A) is monitored. It is shown that photodissociation of HC2CN in its linear predissociative 1Sigma(+) state produces predominantly ground-state CN in rotationally and vibrationally excited states. The vibrational population ratios and the temperatures computed from a Boltzmann fit of the rotational levels are given in a table. The excitation of CH3CN produces CN radicals almost entirely in the first excited A-state with vibrational excitation.

Cody, R. J.↗

Absolute linestrengths in the H2O2 nu6 band

Absolute linestrengths at 295 K have been measured for selected lines in the nu6 band of H2O2 using a tunable diode-laser spectrometer. H2O2 concentrations in a flowing gas mixture were determined by ultraviolet (uv) absorption at 254 nm using a collinear infrared (ir) and uv optical arrangement. The measured linestrengths are approx. 60 percent larger than previously reported values when absorption by hot bands in H2O2 is taken into account.

May, Randy D.↗

Species and velocity visualization of unseeded heated air and combusting hydrogen jets using laser and flashlamp sources

Three techniques for the visualization of species and/or velocity in unseeded H2/air flames and heated air jets are described and preliminary image data are presented. The techniques described are: (1) simultaneous ArF laser imaging of H2, O2, and Rayleigh cross-section weighted density in an H2, O2, and Rayleigh cross-section weighted density in an H2/air flame; (2) ultraviolet flashlamp imaging of O2, OH, and Rayleigh cross-section weighted density in an H2/air flame; and (3) Raman Excitation plus Laser Induced Electronic Fluorescence velocimetry in heater air flows, up to static temperatures of 700 K. Application of these techniques, individually or in combination, should provide useful insight into mixing and reacting flows containing H2, O2, N2 and reaction intermediates such as OH.

Diskin, Glenn S.↗

Photothermal degradation studies

Key reaction intermediates of photooxidation identified and characterized by laser flash Electron Spin Resonance (ESR) spectroscopy were discussed. Effects of temperature and ultraviolet intensity were studied in order to develop meaningful accelerated testing procedures for encapsulant evaluation. In a program to study the failure of Tedlar/ethylene vinyl acetate (EVA)/stainless steel modules, failure modes similar to those observed outdoors in real-time conditions were simulated in accelerated testing. An experimental technique was developed to quantitatively assess the extent of degradation.

Liang, R. H.↗

One-Dimensional Spontaneous Raman Measurements Made in a Gas Turbine Combustor

The NASA Glenn Research Center and the aerospace industry are designing and testing low-emission combustor concepts to build the next generation of cleaner, more fuel efficient aircraft powerplants. These combustors will operate at much higher inlet temperatures and at pressures that are up to 3 to 5 times greater than combustors in the current fleet. From a test and analysis viewpoint, there is an increasing need for measurements from these combustors that are nonintrusive, simultaneous, multipoint, and more quantitative. Glenn researchers have developed several unique test facilities (refs. 1 and 2) that allow, for the first time, optical interrogation of combustor flow fields, including subcomponent performance, at pressures ranging from 1 to 60 bar (1 to 60 atm). Experiments conducted at Glenn are the first application of a visible laser-pumped, one-dimensional, spontaneous Raman-scattering technique to analyze the flow in a high-pressure, advanced-concept fuel injector at pressures thus far reaching 12 bar (12 atm). This technique offers a complementary method to the existing two- and three-dimensional imaging methods used, such as planar laser-induced fluorescence. Raman measurements benefit from the fact that the signal from each species is a linear function of its density, and the relative densities of all major species can be acquired simultaneously with good precision. The Raman method has the added potential to calibrate multidimensional measurements by providing an independent measurement of species number-densities at known points within the planar laser-induced fluorescence images. The visible Raman method is similar to an ultraviolet-Raman technique first tried in the same test facility (ref. 3). However, the visible method did not suffer from the ultraviolet technique's fuel-born polycyclic aromatic hydrocarbon fluorescence interferences.

DeGroot, Wilhelmus A.↗

Stabilization of He2(A(sup 3)Sigma(sub u)(+)) molecules in liquid helium by optical pumping for vacuum UV laser

A technique is disclosed for achieving large populations of metastable spin-aligned He2(a 3 Sigma u +) molecules in superfluid helium to obtain lasing in the vacuum ultraviolet wavelength regime around 0.0800 micron m by electronically exciting liquid (superfluid) helium with a comparatively low-current electron beam and spin aligning the metastable molecules by means of optical pumping with a modestly-powered (100mW) circularly-polarized continuous wave laser operating at, for example, 0.9096 or 0.4650 micron m. Once a high concentration of spin-aligned He2 (a 3 Sigma u +) is achieved with lifetimes of a few milliseconds, a strong microwave signal destroys the spin alignment and induces a quick collisional transition of He2 (a 3 Sigma u +) molecules to the a 1 Sigma u + state and thereby a lasing transition to the X 1 Sigma g + state.

Zmuidzinas, J. S.↗

Fluorescence detection of organic molecules in the Jovian atmosphere

A search for fluorescent emission due to the presence of possible organic molecules in the Jovian atmosphere is described. We first consider natural Jovian fluorescent emission excited by precipitating auroral particles. Due to our lack of knowledge of the Jovian precipitating particle energies and fluxes we next consider fluorescent emission excited by a laser system aboard a Jupiter spacecraft. Laser-induced fluorescence is routinely used to monitor trace constituents and pollutants in the terrestrial atmosphere. Several spacecraft laser systems are currently under development. Our calculations indicate that laser-induced fluorescent detection is approximately two orders of magnitude more sensitive than rocket ultraviolet measurements of possible Jovian absorption features at 2600 A that have been attributed to the presence of adenine or benzene.

Levine, J. S.↗

Ultraviolet and extreme ultraviolet response of charge-coupled-device detectors

Results of a program to enhance the ultraviolet and extreme ultraviolet response of charge-coupled devices are presented. The ultimate goal of the program is to develop a large format device with both high and stable quantum efficiency from 100 to 3000 A that can be used as a windowless imaging detector in a space environment. Ultraviolet quantum efficiency measurements have been made for several ion-implanted and laser-annealed test CCDs. Quantum efficiencies as high as 22 percent at 2500 A, where the absorption depth in silicon is about 55 A, have been observed in one such test CCD. Quantum efficiency measurements of standard back-illuminated CCDs are also presented.

Stern, R. A.↗

Laser Rayleigh-Scattering During Space Shuttle Entry

Report presents detailed study of capabilities and requirements for equipment of proposed ultraviolet Rayleigh-scattering instrument to be carried aboard Space Shuttle. Density of atmosphere around flightpath measured. With accuracy and resolution, measurements adequate for detection of small-scale meteorological structure affecting analysis of flight dynamic data of reentering spacecraft. Also discusses extensions of concept to measurements of location of, and density as function of position in, shock wave of Space Shuttle. Measurements provide baseline data for verification of computer models of high-enthalpy hypersonic, nonequilibrium, and viscous conditions.

Mckenzie, Robert L.↗

Calibration of passive remote observing optical and microwave instrumentation; Proceedings of the Meeting, Orlando, FL, Apr. 3-5, 1991

Various papers on the calibration of passive remote observing optical and microwave instrumentation are presented. Individual topics addressed include: on-board calibration device for a wide field-of-view instrument, calibration for the medium-resolution imaging spectrometer, cryogenic radiometers and intensity-stabilized lasers for EOS radiometric calibrations, radiometric stability of the Shuttle-borne solar backscatter ultraviolet spectrometer, ratioing radiometer for use with a solar diffuser, requirements of a solar diffuser and measurements of some candidate materials, reflectance stability analysis of Spectralon diffuse calibration panels, stray light effects on calibrations using a solar diffuser, radiometric calibration of SPOT 23 HRVs, surface and aerosol models for use in radiative transfer codes. Also addressed are: calibrated intercepts for solar radiometers used in remote sensor calibration, radiometric calibration of an airborne multispectral scanner, in-flight calibration of a helicopter-mounted Daedalus multispectral scanner, technique for improving the calibration of large-area sphere sources, remote colorimetry and its applications, spatial sampling errors for a satellite-borne scanning radiometer, calibration of EOS multispectral imaging sensors and solar irradiance variability.

Guenther, Bruce W.↗

A Compact Ti:Sapphire Laser With its Third Harmonic Generation (THG) for an Airborne Ozone Differential Absorption Lidar (DIAL) Transmitter

A compact and high-pulse-energy Ti:Sapphire laser with its Third Harmonic Generation (THG) has been developed for an airborne ozone differential absorption lidar (DIAL) to study the distributions and concentrations of the ozone throughout the troposphere. The Ti:Sapphire laser, pumped by a frequency-doubled Nd:YAG laser and seeded by a single mode diode laser, is operated either at 867 nm or at 900 nm with a pulse repetition frequency of 20 Hz. High energy laser pulses (more than 110 mJ/pulse) at 867 nm or 900 nm with a desired beam quality have been achieved and utilized to generate its third harmonic at 289nm or 300nm, which are on-line and off-line wavelengths of an airborne ozone DIAL. After being experimentally compared with Beta-Barium Borate (beta - BaB2O4 or BBO) nonlinear crystals, two Lithium Triborate (LBO) crystals (5 x 5 x 20 cu mm) are selected for the Third Harmonic Generation (THG). In this paper, we report the Ti:Sapphire laser at 900 nm and its third harmonic at 300 nm. The desired high ultraviolet (UV) output pulse energy is more than 30 mJ at 300 nm and the energy conversion efficiency from 900 nm to 300 nm is 30%.

Chen, Songsheng↗

Single photon infrared emission spectroscopy: a study of IR emission from UV laser excited PAHs between 3 and 15 micrometers

Single-photon infrared emission spectroscopy (SPIRES) has been used to measure emission spectra from polycyclic aromatic hydrocarbons (PAHs). A supersonic free-jet expansion has been used to provide emission spectra of rotationally cold and vibrationally excited naphthalene and benzene. Under these conditions, the observed width of the 3.3-micrometers (C-H stretch) band resembles the bandwidths observed in experiments in which emission is observed from naphthalene with higher rotational energy. To obtain complete coverage of IR wavelengths relevant to the unidentified infrared bands (UIRs), UV laser-induced desorption was used to generate gas-phase highly excited PAHs. Lorentzian band shapes were convoluted with the monochromator-slit function in order to determine the widths of PAH emission bands under astrophysically relevant conditions. Bandwidths were also extracted from bands consisting of multiple normal modes blended together. These parameters are grouped according to the functional groups mostly involved in the vibration, and mean bandwidths are obtained. These bandwidths are larger than the widths of the corresponding UIR bands. However, when the comparison is limited to the largest PAHs studied, the bandwidths are slightly smaller than the corresponding UIR bands. These parameters can be used to model emission spectra from PAH cations and cations of larger PAHs, which are better candidate carriers of the UIRs.

Non-NASA Center↗

Optical signatures of molecular particles via mass-selected cluster spectroscopy

A new molecular beam apparatus was developed to study optical absorption in cold (less than 100 K) atomic clusters and complexes produced by their condensation with simple molecular gases. In this instrument, ionized clusters produced in a laser vaporization nozzle source are mass selected and studied with photodissociation spectroscopy at visible and ultraviolet wavelengths. This new approach can be applied to synthesize and characterize numerous particulates and weakly bound complexes expected in planetary atmospheres and in comets.

Duncan, Michael A.↗

The Lunar Atmosphere and Dust Environment Explorer (LADEE) Mission

The Lunar Atmosphere and Dust Environment Explorer (LADEE) is a Lunar science orbiter mission currently under development to address the goals of the National Research Council decadal surveys and the recent "Scientific Context for Exploration of the Moon" (SCEM) [1] report to study the pristine state of the lunar atmosphere and dust environment prior to significant human activities. LADEE will determine the composition of the lunar atmosphere and investigate the processes that control its distribution and variability, including sources, sinks, and surface interactions. LADEE will also determine whether dust is present in the lunar exosphere, and reveal the processes that contribute to its sources and variability. These investigations are relevant to our understanding of surface boundary exospheres and dust processes throughout the solar system, address questions regarding the origin and evolution of lunar volatiles, and have potential implications for future exploration activities. LADEE employs a high heritage science instrument payload including a neutral mass spectrometer, ultraviolet spectrometer, and dust sensor. In addition to the science payloads, LADEE will fly a laser communications system technology demonstration that could provide a building block for future space communications architectures. LADEE is an important component in NASA's portfolio of near-term lunar missions, addressing objectives that are currently not covered by other U.S. or international efforts, and whose observations must be conducted before large-scale human or robotic activities irrevocably perturb the tenuous and fragile lunar atmosphere. LADEE will also demonstrate the effectiveness of a low-cost, rapid-development program utilizing a modular bus design launched on the new Minotaur V launch vehicle. Once proven, this capability could enable future lunar missions in a highly cost constrained environment. This paper describes the LADEE objectives, mission design, and technical approach.

Spremo, Stevan↗

A 15 Meter Laser-Stabilized Imaging Interferometer

The Laser-Stabilized Imaging Interferometer (LASII) concept is being developed as a candidate for the next generation of optical resolution beyond Hubble Space Telescope (HST). The essential ingredients are: a rigid and stable structure to minimize mechanical and thermal distortion, active control of the optical geometry by a laser metrology system, a self-deploying structure fitting into a single launch vehicle, and ultraviolet operation. We have modified earlier design concepts to fit the scale of an intermediate sized NASA mission.

Imaging↗