Search NASA⌕ Search

SEARCH · Search NASA

Results for “VESTIBULAR TESTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Some physiological effects of alternation between zero gravity and one gravity

The anatomy and physiology of the healthy vestibular system and the history of its study, maintenance of muskuloskeletal fitness under low-gravity conditions, tests of motion sickness, and data and techniques on testing subjects in a slow rotation room, are covered. Components of the inner ear labyrinth and their behavior in relation to equilibrium, gravity and inertial forces, motion sickness, and dizziness are discussed. Preventive medicine, the biologically effective force environment, weightlessness per se, activity in a weightless spacecraft, exercizing required to maintain musculoskeletal function, and ataxia problems are dealt with.

Graybiel, A.↗

Certain aspects of the vestibular problem in space medicine

Vestibulovegetative disorders on manned space flights are discussed. A study relating to the vestibular stimuli in respiration, diaphoresis cardiac rhythm and a broad complex of hemodynamic indices was conducted. Certain tests for astronaut candidates are discussed.

Source record↗

[Activities of Psychology Dept., California Univ.]

We have completed two studies during the grant period, with manuscripts published or ready for submission for publication: (1) Dual adaptation and adaptive generalization in the human vestibuloocular reflex and (2) Frequency vs. acceleration specificity in human VOR adaptation. In the 1st study two studies examined the possibility that rotational VOR plasticity is subject to dual adaptation and adaptive generalization. Subjects in the experimental condition were exposed to an altered visual-vestibular environment for about four minutes every day for five consecutive days. The working hours between these testing sessions constituted re-exposure to the normal visual environment. Thus, subjects were repeatedly adapting and re-adapting to both environments which is a condition designed to produce dual adaptation. In each training session a measure of baseline VOR gain was obtained (in the dark). A small laser spot (the only visual stimulus) was systematically moved in the same direction as the subject's head, but by half the angle of rotation (target/head gain = 0.5). This resulted in adaptation values relativized to the non-adapted gain of each subject. These values were then analyzed using an analysis of variance with day and session (within a day) as factors. In the 2nd study human VOR adaption has been assumed to be frequency specific, despite the fact that the semicircular canals are simulated by rotational acceleration and not frequency per se.

Bridgeman, Bruce↗

Dynamic balance control in elders: gait initiation assessment as a screening tool

OBJECTIVE: To determine whether measurements of center of gravity-center of pressure separation (CG-CP moment arm) during gait initiation can differentiate healthy from disabled subjects with sufficient specificity and sensitivity to be useful as a screening test for dynamic balance in elderly patients. SUBJECTS: Three groups of elderly subjects (age, 74.97+/-6.56 yrs): healthy elders (HE, n = 21), disabled elders (DE, n = 20), and elders with vestibular hypofunction (VH, n = 18). DESIGN: Cross-sectional, intact-groups research design. Peak CG-CP moment arm measures how far the subject will tolerate the whole-body CG to deviate from the ground reaction force's CP; it represents dynamic balance control. Screening test cutoff points at 16 to 18 cm peak CG-CP moment arm predicted group membership. RESULTS: The magnitude of peak CG-CP moment arm was significantly greater in HE than in DE and VH subjects (p<.01) and was not different between the DE and VH groups. The peak CG-CP moment arm occurred at the end of single stance phase in all groups. As a screening test, the peak moment arm has greater than 50% sensitivity and specificity to discriminate the HE group from the DE and VH groups with peak CG-CP moment arm cutoff points between 16 and 18 cm. CONCLUSIONS: Examining dynamic balance through the use of the CG-CP moment arm during single stance in gait initiation discriminates between nondisabled and disabled older persons and warrants further investigation as a potential tool to identify people with balance dysfunction.

NASA Discipline Neuroscience↗

NASA's Zero-g aircraft operations

NASA's Zero-g aircraft, operated by the Johnson Space Center, provides the unique weightless or zero-g environment of space flight for hardware development and test and astronaut training purposes. The program, which began in 1959, uses a slightly modified Boeing KC-135A aircraft, flying a parabolic trajectory, to produce weightless periods of 20 to 25 seconds. The program has supported the Mercury, Gemini, Apollo, Skylab, Apollo-Soyuz and Shuttle programs as well as a number of unmanned space operations. Typical experiments for flight in the aircraft have included materials processing experiments, welding, fluid manipulation, cryogenics, propellant tankage, satellite deployment dynamics, planetary sciences research, crew training with weightless indoctrination, space suits, tethers, etc., and medical studies including vestibular research. The facility is available to microgravity research organizations on a cost-reimbursable basis, providing a large, hands-on test area for diagnostic and support equipment for the Principal Investigators and providing an iterative-type design approach to microgravity experiment development. The facility allows concepts to be proven and baseline experimentation to be accomplished relatively inexpensively prior to committing to the large expense of a space flight.

Williams, R. K.↗

Visual-vestibular interaction in humans during earth-horizontal axis rotation

Visual-vestibular interaction using 60 percent constant velocity earth horizontal axis yaw rotation, simulating both the horizontal semicircular canals and the otolith organs, was measured in seven human subjects. Subjects were tested with their eyes open in the dark (EOD) while fixating upon a target rotating with them (FIX), and while observing stationary optokinetic stripes (VVR). Resulting nystagmus slow component velocity (SCV) was analyzed for EOD, FIX, and VVR conditions. It is concluded that the visual-vestibular interactions during EHA differ significantly from those during rotation about the vertical; specifically, there is a nonlinear interaction between linear acceleration and optokinetic nystagmus.

Wall, Conrad, III↗

Two-dimensional spatiotemporal coding of linear acceleration in vestibular nuclei neurons

Response properties of vertical (VC) and horizontal (HC) canal/otolith-convergent vestibular nuclei neurons were studied in decerebrate rats during stimulation with sinusoidal linear accelerations (0.2-1.4 Hz) along different directions in the head horizontal plane. A novel characteristic of the majority of tested neurons was the nonzero response often elicited during stimulation along the "null" direction (i.e., the direction perpendicular to the maximum sensitivity vector, Smax). The tuning ratio (Smin gain/Smax gain), a measure of the two-dimensional spatial sensitivity, depended on stimulus frequency. For most vestibular nuclei neurons, the tuning ratio was small at the lowest stimulus frequencies and progressively increased with frequency. Specifically, HC neurons were characterized by a flat Smax gain and an approximately 10-fold increase of Smin gain per frequency decade. Thus, these neurons encode linear acceleration when stimulated along their maximum sensitivity direction, and the rate of change of linear acceleration (jerk) when stimulated along their minimum sensitivity direction. While the Smax vectors were distributed throughout the horizontal plane, the Smin vectors were concentrated mainly ipsilaterally with respect to head acceleration and clustered around the naso-occipital head axis. The properties of VC neurons were distinctly different from those of HC cells. The majority of VC cells showed decreasing Smax gains and small, relatively flat, Smin gains as a function of frequency. The Smax vectors were distributed ipsilaterally relative to the induced (apparent) head tilt. In type I anterior or posterior VC neurons, Smax vectors were clustered around the projection of the respective ipsilateral canal plane onto the horizontal head plane. These distinct spatial and temporal properties of HC and VC neurons during linear acceleration are compatible with the spatiotemporal organization of the horizontal and the vertical/torsional ocular responses, respectively, elicited in the rat during linear translation in the horizontal head plane. In addition, the data suggest a spatially and temporally specific and selective otolith/canal convergence. We propose that the central otolith system is organized in canal coordinates such that there is a close alignment between the plane of angular acceleration (canal) sensitivity and the plane of linear acceleration (otolith) sensitivity in otolith/canal-convergent vestibular nuclei neurons.

NASA Discipline Neuroscience↗

Optomotor behaviour in Xenopus laevis tadpoles as a measure of the effect of gravity on visual and vestibular neural integration

The ability of aquatic vertebrates to maintain their position requires integration of visual and vestibular sensory information. To understand better how aquatic animals integrate such information, we measured the optomotor behaviour of Xenopus laevis tadpoles raised in growth chambers in microgravity (< 10(-3)g), normal gravity (1 g), hypergravity (3 g) and on a slowly rotating clinostat (simulated microgravity). The goal of this research was to determine how development in an altered gravitational force field affects the visual- and vestibular-dependent behaviour of tadpoles. This research represents the first time that the optomotor behaviour of an organism raised from fertilization in microgravity has been tested. Significant differences were observed in the optomotor behaviour among the four gravity treatments. When first exposed to normal gravity, the microgravity-raised tadpoles exhibited the strongest (or most positive) optomotor behaviour, while the 3 g centrifuge tadpoles showed no optomotor response. Some abnormal behaviours (such as erratic swimming, lying motionless and abnormal swimming posture) were observed in the tadpoles raised in altered gravity on the initial day of testing. One day later, the tadpoles raised in hypergravity did not differ significantly in their optomotor behaviour from control tadpoles raised in normal gravity. However, tadpoles raised in microgravity still displayed an exaggerated optomotor response. One week after the tadpoles had been introduced to normal gravity, there was no longer a significant difference in optomotor behaviour among the different gravity treatments. This convergence of optomotor behaviour by tadpoles from the different treatment reflects the acclimation of their vestibular systems to normal gravity.

NASA Discipline Developmental Biology↗

Vestibular Stochastic Resonance as a Method to Improve Balance Function: Optimization of Stimulus Characteristics

Stochastic resonance (SR) is a mechanism by which noise can assist and enhance the response of neural systems to relevant sensory signals. Application of imperceptible SR noise coupled with sensory input through the proprioceptive, visual, or vestibular sensory systems has been shown to improve motor function. Specifically, studies have shown that that vestibular electrical stimulation by imperceptible stochastic noise, when applied to normal young and elderly subjects, significantly improved their ocular stabilization reflexes in response to whole-body tilt as well as balance performance during postural disturbances. The goal of this study was to optimize the characteristics of the stochastic vestibular signals for balance performance during standing on an unstable surface. Subjects performed a standardized balance task of standing on a block of 10 cm thick medium density foam with their eyes closed for a total of 40 seconds. Stochastic electrical stimulation was applied to the vestibular system through electrodes placed over the mastoid process behind the ears during the last 20 seconds of the test period. A custom built constant current stimulator with subject isolation delivered the stimulus. Stimulation signals were generated with frequencies in the bandwidth of 1-2 Hz and 0.01-30 Hz. Amplitude of the signals were varied in the range of 0- +/-700 micro amperes with the RMS of the signal increased by 30 micro amperes for each 100 micro amperes increase in the current range. Balance performance was measured using a force plate under the foam block and inertial motion sensors placed on the torso and head segments. Preliminary results indicate that balance performance is improved in the range of 10-25% compared to no stimulation conditions. Subjects improved their performance consistently across the blocks of stimulation. Further the signal amplitude at which the performance was maximized was different in the two frequency ranges. Optimization of the frequency and amplitude of the signal characteristics of the stochastic noise signals on maximizing balance performance will have a significant impact in its development as a unique system to aid recovery of function in astronauts after long duration space flight or for people with balance disorders.

Mulavara, Ajitkumar↗

Precision contact of the fingertip reduces postural sway of individuals with bilateral vestibular loss

Contact of the hand with a stationary surface attenuates postural sway in normal individuals even when the level of force applied is mechanically inadequate to dampen body motion. We studied whether subjects without vestibular function would be able to substitute contact cues from the hand for their lost labyrinthine function and be able to balance as well as normal subjects in the dark without finger contact. We also studied the relative contribution of sight of the test chamber to the two groups. Subjects attempted to maintain a tandem Romberg stance for 25 s under three levels of fingertip contact: no contact; light-touch contact, up to 1 N (approximately 100 g) force; and unrestricted contact force. Both eyes open and eyes closed conditions were evaluated. Without contact, none of the vestibular loss subjects could stand for more than a few seconds in the dark without falling; all the normals could. The vestibular loss subjects were significantly more stable in the dark with light touch of the index finger than the normal subjects in the dark without touch. They also swayed less in the dark with light touch than when permitted sight of the test chamber without touch, and less with sight and touch than just sight. The normal subjects swayed less in the dark with touch than without, and less with sight and touch than sight alone. These findings show that during quiet stance light touch of the index finger with a stationary surface can be as effective or even more so than vestibular function for minimizing postural sway.

NASA Discipline Neuroscience↗

Sensorimotor Predictors: Examining the Relationship Between Measures of Post-Landing Sensorimotor Functional Task Performance

Spaceflight drives adaptive changes in healthy individuals appropriate for sensorimotor function in a microgravity environment. These changes are maladaptive for return to Earth's gravity. The inter-individual variability of sensorimotor decrements is striking, although poorly understood. The goal of this study is to identify a set of behavioral, neuroimaging and genetic measures that can be used to predict early post-flight performance on sensorimotor functional tasks. To date, we have recruited fifteen astronauts who returned from the International Space Station on Soyuz and participated in sensorimotor field tests and/or posturography within one day following long-duration spaceflight. We are specifically utilizing a combination of three quantitative post-flight functional task outcomes(relative to pre-flight baselines): tandem walk, recovery from fall and dynamic posturography, along with a subjective self-rating of post-flight decrements and recovery. The recovery from fall is performed with eyes open on a stable support, allowing the use of vestibular, visual and proprioceptive feedback for task performance. In contrast, the dynamic posturography measures are performed with eyes closed on asway-referenced unstable support, requiring reliance on vestibular feedback for task performance. Tandem walk is performed on a stable surface with eyes open and eyes closed. Fourteen of the 15 subjects performed the field tests. These were nominally performed during three timepoints on the first postflight day, while posturography was performed only once during the third time point after direct return to JSC. More than 20% were unable to complete the initial field testing in the medical tent, while all participants completed testing during the third time point at JSC. As expected, there was considerable variability among all performance outcome measures, with more variability post-flight relative to preflight. Given the variability in all post-flight outcomes, we have been examining the relationships in performance across tasks. While there is a strong association within tests obtained at different landing daytime points, our preliminary findings suggest that by R+24 hrs performance on one post-flight test does not necessarily correlate with performance on other post-flight tests. This underscores the importance of a comprehensive post-flight test battery including different types of tasks with varying sensory feedback. We expect that further examining specific behavioral, neuroimaging and genetic sensorimotor biomarkers with post-flight functional task performance will improve both our understanding of the individual variability and our strategy to optimize sensorimotor countermeasures.

S J Wood↗

Sensorimotor Predictors: Examining the Relationship Between Measures of Post-Landing Sensorimotor Functional Task Performance

Spaceflight drives adaptive changes in healthy individuals appropriate for sensorimotor function in a microgravity environment. These changes are maladaptive for return to Earth's gravity. The inter-individual variability of sensorimotor decrements is striking, although poorly understood. The goal of this study is to identify a set of behavioral, neuroimaging and genetic measures that can be used to predict early post-flight performance on sensorimotor functional tasks. To date, we have recruited fifteen astronauts who returned from the International Space Station on Soyuz and participated in sensorimotor field tests and/or posturography within one day following long-duration spaceflight. We are specifically utilizing a combination of three quantitative post-flight functional task outcomes(relative to pre-flight baselines): tandem walk, recovery from fall and dynamic posturography, along with a subjective self-rating of post-flight decrements and recovery. The recovery from fall is performed with eyes open on a stable support, allowing the use of vestibular, visual and proprioceptive feedback for task performance. In contrast, the dynamic posturography measures are performed with eyes closed on asway-referenced unstable support, requiring reliance on vestibular feedback for task performance. Tandem walk is performed on a stable surface with eyes open and eyes closed. Fourteen of the 15 subjects performed the field tests. These were nominally performed during three timepoints on the first post flight day, while posturography was performed only once during the third time point after direct return to JSC. More than 20% were unable to complete the initial field testing in the medical tent, while all participants completed testing during the third time point at JSC. As expected, there was considerable variability among all performance outcome measures, with more variability post-flight relative to preflight. Given the variability in all post-flight outcomes, we have been examining the relationships in performance across tasks. While there is a strong association with in tests obtained at different landing daytime points, our preliminary findings suggest that by R+24 hrs performance on one post-flight test does not necessarily correlate with performance on other post-flight tests. This underscores the importance of a comprehensive post-flight test battery including different types of tasks with varying sensory feedback. We expect that further examining specific behavioral, neuroimaging and genetic sensorimotor biomarkers with post-flight functional task performance will improve both our understanding of the individual variability and our strategy to optimize sensorimotor countermeasures.

Yiri De Dios↗

Improving Sensorimotor Function and Adaptation using Stochastic Vestibular Stimulation

Astronauts experience sensorimotor changes during adaption to G-transitions that occur when entering and exiting microgravity. Post space flight, these sensorimotor disturbances can include postural and gait instability, visual performance changes, manual control disruptions, spatial disorientation, and motion sickness, all of which can hinder the operational capabilities of the astronauts. Crewmember safety would be significantly increased if sensorimotor changes brought on by gravitational changes could be mitigated and adaptation could be facilitated. The goal of this research is to investigate and develop the use of electrical stochastic vestibular stimulation (SVS) as a countermeasure to augment sensorimotor function and facilitate adaptation. For this project, SVS will be applied via electrodes on the mastoid processes at imperceptible amplitude levels. We hypothesize that SVS will improve sensorimotor performance through the phenomena of stochastic resonance, which occurs when the response of a nonlinear system to a weak input signal is optimized by the application of a particular nonzero level of noise. In line with the theory of stochastic resonance, a specific optimal level of SVS will be found and tested for each subject [1]. Three experiments are planned to investigate the use of SVS in sensory-dependent tasks and performance. The first experiment will aim to demonstrate stochastic resonance in the vestibular system through perception based motion recognition thresholds obtained using a 6-degree of freedom Stewart platform in the Jenks Vestibular Laboratory at Massachusetts Eye and Ear Infirmary. A range of SVS amplitudes will be applied to each subject and the subjectspecific optimal SVS level will be identified as that which results in the lowest motion recognition threshold, through previously established, well developed methods [2,3,4]. The second experiment will investigate the use of optimal SVS in facilitating sensorimotor adaptation to system disturbances. Subjects will adapt to wearing minifying glasses, resulting in decreased vestibular ocular reflex (VOR) gain. The VOR gain will then be intermittently measured while the subject readapts to normal vision, with and without optimal SVS. We expect that optimal SVS will cause a steepening of the adaptation curve. The third experiment will test the use of optimal SVS in an operationally relevant aerospace task, using the tilt translation sled at NASA Johnson Space Center, a test platform capable of recreating the tilt-gain and tilt-translation illusions associated with landing of a spacecraft post-space flight. In this experiment, a perception based manual control measure will be used to compare performance with and without optimal SVS. We expect performance to improve in this task when optimal SVS is applied. The ultimate goal of this work is to systematically investigate and further understand the potential benefits of stochastic vestibular stimulation in the context of human space flight so that it may be used in the future as a component of a comprehensive countermeasure plan for adaptation to G-transitions.

Galvan, R. C.↗

Experimental tests of a superposition hypothesis to explain the relationship between the vestibuloocular reflex and smooth pursuit during horizontal combined eye-head tracking in humans

1. We used a modeling approach to test the hypothesis that, in humans, the smooth pursuit (SP) system provides the primary signal for cancelling the vestibuloocular reflex (VOR) during combined eye-head tracking (CEHT) of a target moving smoothly in the horizontal plane. Separate models for SP and the VOR were developed. The optimal values of parameters of the two models were calculated using measured responses of four subjects to trials of SP and the visually enhanced VOR. After optimal parameter values were specified, each model generated waveforms that accurately reflected the subjects' responses to SP and vestibular stimuli. The models were then combined into a CEHT model wherein the final eye movement command signal was generated as the linear summation of the signals from the SP and VOR pathways. 2. The SP-VOR superposition hypothesis was tested using two types of CEHT stimuli, both of which involved passive rotation of subjects in a vestibular chair. The first stimulus consisted of a "chair brake" or sudden stop of the subject's head during CEHT; the visual target continued to move. The second stimulus consisted of a sudden change from the visually enhanced VOR to CEHT ("delayed target onset" paradigm); as the vestibular chair rotated past the angular position of the stationary visual stimulus, the latter started to move in synchrony with the chair. Data collected during experiments that employed these stimuli were compared quantitatively with predictions made by the CEHT model. 3. During CEHT, when the chair was suddenly and unexpectedly stopped, the eye promptly began to move in the orbit to track the moving target. Initially, gaze velocity did not completely match target velocity, however; this finally occurred approximately 100 ms after the brake onset. The model did predict the prompt onset of eye-in-orbit motion after the brake, but it did not predict that gaze velocity would initially be only approximately 70% of target velocity. One possible explanation for this discrepancy is that VOR gain can be dynamically modulated and, during sustained CEHT, it may assume a lower value. Consequently, during CEHT, a smaller-amplitude SP signal would be needed to cancel the lower-gain VOR. This reduction of the SP signal could account for the attenuated tracking response observed immediately after the brake. We found evidence for the dynamic modulation of VOR gain by noting differences in responses to the onset and offset of head rotation in trials of the visually enhanced VOR.(ABSTRACT TRUNCATED AT 400 WORDS).

Non-NASA Center↗

Role of orientation reference selection in motion sickness

The objectives of this proposal were developed to further explore and quantify the orientation reference selection abilities of subjects and the relation, if any, between motion sickness and orientation reference selection. The overall objectives of this proposal are to determine (1) if motion sickness susceptibility is related to sensory orientation reference selection abilities of subjects, (2) if abnormal vertical canal-otolith function is the source of these abnormal posture control strategies and if it can be quantified by vestibular and oculomotor reflex measurements, and (3) if quantifiable measures of perception of vestibular and visual motion cues can be related to motion sickness susceptibility and to orientation reference selection ability demonstrated by tests which systematically control the sensory imformation available for orientation.

Peterka, Robert J.↗

Vestibular control of sympathetic activity. An otolith-sympathetic reflex in humans

It has been proposed that a vestibular reflex originating in the otolith organs and other body graviceptors modulates sympathetic activity during changes in posture with regard to gravity. To test this hypothesis, we selectively stimulated otolith and body graviceptors sinusoidally along different head axes in the coronal plane with off-vertical axis rotation (OVAR) and recorded sympathetic efferent activity in the peroneal nerve (muscle sympathetic nerve activity, MSNA), blood pressure, heart rate, and respiratory rate. All parameters were entrained during OVAR at the frequency of rotation, with MSNA increasing in nose-up positions during forward linear acceleration and decreasing when nose-down. MSNA was correlated closely with blood pressure when subjects were within +/-90 degrees of nose-down positions with a delay of 1.4 s, the normal latency of baroreflex-driven changes in MSNA. Thus, in the nose-down position, MSNA was probably driven by baroreflex afferents. In contrast, when subjects were within +/-45 degrees of the nose-up position, i.e., when positive linear acceleration was maximal along the naso-ocipital axis, MSNA was closely related to gravitational acceleration at a latency of 0.4 s. This delay is too short for MSNA changes to be mediated by the baroreflex, but it is compatible with the delay of a response originating in the vestibular system. We postulate that a vestibulosympathetic reflex, probably originating mainly in the otolith organs, contributes to blood pressure maintenance during forward linear acceleration. Because of its short latency, this reflex may be one of the earliest mechanisms to sustain blood pressure upon standing.

NASA Discipline Neuroscience↗

Perception of the upright and susceptibility to motion sickness as functions of angle of tilt and angular velocity in off-vertical rotation

Motion sickness susceptibility of four normal subjects was measured in terms of duration of exposure necessary to evoke moderate malaise (MIIA) as a function of velocity in a chair rotated about a central axis tilted 10 deg with respect to gravitational upright. The subjects had little or no susceptibility to this type of rotation at 2.5 and 5.0 rpm, but with further increases in rate, the MIIA endpoint was always reached and with ever shorter test durations. Minimal provocative periods for all subjects were found at 15 or 20 rpm. Higher rotational rates dramatically reversed the vestibular stressor effect, and the subjects as a group tended to reach a plateau of relatively low susceptibility at 40 and 45 rpm. At these higher velocities, furthermore, the subjects essentially lost their sensation of being tilted off vertical. In the second half of the study, the effect of tilt angle was varied while the rotation rate was maintained at a constant 17.5 rpm. Two subjects were completely resistant to symptoms of motion sickness when rotated at 2.5 deg off vertical; with greater off-vertical angles, the susceptibility of all subjects increased sharply at first, then tapered off in a manner reflecting a Fechnerian function.

Earl F. Miller II↗

Using Tests Designed to Measure Individual Sensorimotor Subsystem Perfomance to Predict Locomotor Adaptability

Astronauts experience sensorimotor disturbances during the initial exposure to microgravity and during the readapation phase following a return to a gravitational environment. These alterations may lead to disruption in the ability to perform mission critical functions during and after these gravitational transitions. Astronauts show significant inter-subject variation in adaptive capability following gravitational transitions. The way each individual's brain synthesizes the available visual, vestibular and somatosensory information is likely the basis for much of the variation. Identifying the presence of biases in each person's use of information available from these sensorimotor subsystems and relating it to their ability to adapt to a novel locomotor task will allow us to customize a training program designed to enhance sensorimotor adaptability. Eight tests are being used to measure sensorimotor subsystem performance. Three of these use measures of body sway to characterize balance during varying sensorimotor challenges. The effect of vision is assessed by repeating conditions with eyes open and eyes closed. Standing on foam, or on a support surface that pitches to maintain a constant ankle angle provide somatosensory challenges. Information from the vestibular system is isolated when vision is removed and the support surface is compromised, and it is challenged when the tasks are done while the head is in motion. The integration and dominance of visual information is assessed in three additional tests. The Rod & Frame Test measures the degree to which a subject's perception of the visual vertical is affected by the orientation of a tilted frame in the periphery. Locomotor visual dependence is determined by assessing how much an oscillating virtual visual world affects a treadmill-walking subject. In the third of the visual manipulation tests, subjects walk an obstacle course while wearing up-down reversing prisms. The two remaining tests include direct measures of knee and ankle proprioception and a functional movement assessment that screens for movement restrictions and asymmetries. To assess each subject's locomotor adaptability subjects walk for twenty minutes on a treadmill that oscillates laterally at 0.3 Hz. Throughout the test metabolic cost provides a measure of exertion and step frequency provides a measure of stability. Additionally, at four points during the perturbation period, reaction time tests are used to probe changes in the amount of mental effort being used to perform the task. As with the adaptive capability observed in astronauts during gravitational transitions, our data shows significant variability between subjects. To aid in the analysis of the results, custom software tools have been developed to enhance in the visualization of the large number of output variables. Preliminary analyses of the data collected to date do not show a strong relationship between adaptability and any single predictor variable. Analysis continues to identify a multifactorial predictor outcome "signature" that do inform us of locomotor adaptability.

Peters, B. T.↗