Structural Health Monitoring on Turbine Engines Using Microwave Blade Tip Clearance Sensors

The ability to monitor the structural health of the rotating components, especially in the hot sections of turbine engines, is of major interest to aero community in improving engine safety and reliability. The use of instrumentation for these applications remains very challenging. It requires sensors and techniques that are highly accurate, are able to operate in a high temperature environment, and can detect minute changes and hidden flaws before catastrophic events occur. The National Aeronautics and Space Administration (NASA) has taken a lead role in the investigation of new sensor technologies and techniques for the in situ structural health monitoring of gas turbine engines. As part of this effort, microwave sensor technology has been investigated as a means of making high temperature non-contact blade tip clearance, blade tip timing, and blade vibration measurements for use in gas turbine engines. This paper presents a summary of key results and findings obtained from the evaluation of two different types of microwave sensors that have been investigated for use possible in structural health monitoring applications. The first is a microwave blade tip clearance sensor that has been evaluated on a large scale Axial Vane Fan, a subscale Turbofan, and more recently on sub-scale turbine engine like disks. The second is a novel microwave based blade vibration sensor that was also used in parallel with the microwave blade tip clearance sensors on the experiments with the sub-scale turbine engine disks.

Gas Turbine Engines↗

Rotor blade-vortex interaction noise reduction and vibration using higher harmonic control

The use of higher harmonic control (HHC) of blade pitch to reduce blade-vortex interaction (BVI) noise is examined by means of a rotor acoustic test. A dynamically scaled, four-bladed, articulated rotor model was tested in a heavy gas (Freon-12) medium. Acoustic and vibration measurements were made for a large range of matched flight conditions where prescribed (open loop) HHC pitch schedules were superimposed on the normal (baseline) collective and cyclic trim pitch. A novel sound power measurement technique was developed to take advantage of the reverberance in the hard walled tunnel. Quantitative sound power results are presented for a 4/rev (4P) collective pitch HHC. By comparing the results using 4P HHC to corresponding baseline (no HHC) conditions, significant midfrequency noise reductions of 5-6 dB are found for low-speed descent conditions where BVI is most intense. For other flight conditions, noise is found to increase with the use of HHC. LF loading noise, as well as fixed and rotating frame vibration levels, show increased levels.

Brooks, Thomas F.↗

Parametric and experimental analysis using a power flow approach

Having defined and developed a structural power flow approach for the analysis of structure-borne transmission of structural vibrations, the technique is used to perform an analysis of the influence of structural parameters on the transmitted energy. As a base for comparison, the parametric analysis is first performed using a Statistical Energy Analysis approach and the results compared with those obtained using the power flow approach. The advantages of using structural power flow are thus demonstrated by comparing the type of results obtained by the two methods. Additionally, to demonstrate the advantages of using the power flow method and to show that the power flow results represent a direct physical parameter that can be measured on a typical structure, an experimental investigation of structural power flow is also presented. Results are presented for an L-shaped beam for which an analytical solution has already been obtained. Furthermore, the various methods available to measure vibrational power flow are compared to investigate the advantages and disadvantages of each method.

Cuschieri, J. M.↗

Reduction of blade-vortex interaction noise using higher harmonic pitch control

An acoustics test using an aeroelastically scaled rotor was conducted to examine the effectiveness of higher harmonic blade pitch control for the reduction of impulsive blade-vortex interaction (BVI) noise. A four-bladed, 110 in. diameter, articulated rotor model was tested in a heavy gas (Freon-12) medium in Langley's Transonic Dynamics Tunnel. Noise and vibration measurements were made for a range of matched flight conditions, where prescribed (open-loop) higher harmonic pitch was superimposed on the normal (baseline) collective and cyclic trim pitch. For the inflow-microphone noise measurements, advantage was taken of the reverberance in the hard walled tunnel by using a sound power determination approach. Initial findings from on-line data processing for three of the test microphones are reported for a 4/rev (4P) collective pitch control for a range of input amplitudes and phases. By comparing these results to corresponding baseline (no control) conditions, significant noise reductions (4 to 5 dB) were found for low-speed descent conditions, where helicopter BVI noise is most intense. For other rotor flight conditions, the overall noise was found to increase. All cases show increased vibration levels.

Brooks, Thomas F.↗

Reduction of blade-vortex interaction noise through higher harmonic pitch control

An acoustics test using an aeroelastically scaled rotor was conducted to examine the effectiveness of higher harmonic blade pitch control for the reduction of impulsive blade-vortex interaction (BVI) noise. A four-bladed, 110 in. diameter, articulated rotor model was tested in a heavy gas (Freon-12) medium in Langley's Transonic Dynamics Tunnel. Noise and vibration measurements were made for a range of matched flight conditions, where prescribed (open-loop) higher harmonic pitch was superimposed on the normal (baseline) collective and cyclic trim pitch. For the inflow-microphone noise measurements, advantage was taken of the reverberance in the hard walled tunnel by using a sound power determination approach. Initial findings from on-line data processing for three of the test microphones are reported for a 4/rev (4P) collective pitch control for a range of input amplitudes and phases. By comparing these results to corresponding baseline (no control) conditions, significant noise reductions (4 to 5 dB) were found for low-speed descent conditions, where helicopter BVI noise is most intense. For other rotor flight conditions, the overall noise was found to increase. All cases show increased vibration levels.

Brooks, Thomas F.↗

Chiral Electrokinetic Phenomena in Single Nanopores

Abstract The arrangement of solvent molecules and ions at solid–liquid interfaces determines electrochemical properties that are important in separations platforms, sensing technologies, and energy‐storage systems. Here we show that single glass and polymer pores in contact with propylene carbonate (PC) solutions of LiClO 4 exhibit an effective surface potential that is modulated by the enantiomeric excess of the solvent. In particular, electrochemical and electrokinetic measurements of ionic transport through glass pipettes and polymer pores reveal that the effective surface potential is significantly lower in solutions prepared using enantiomerically pure PC than in solutions prepared using racemic PC. Both pore systems became positively charged in all racemic solutions examined in the range of LiClO 4 concentrations between 1 mM and 100 mM, whereas solutions in ( R )‐(+)‐PC induced a positive surface potential only at concentrations above ~5 mM. The effective surface potential is quantified through asymmetry in current–voltage curves and zeta‐potential measurements. Vibrational sum‐frequency‐generation experiments on LiClO 4 solutions in racemic and enantiomerically pure PC indicate that the surface lipid‐bilayer‐like region in the former is more strongly organized than in the latter, dictating the favorable positions for lithium and perchlorate ions in each case. The more ordered molecular packing in the racemic liquid leads to accumulation of lithium ions on the outside of the bilayer, creating a higher effective positive charge. Our results highlight the extreme sensitivity of the interfacial potential on molecular organization of the solvent, and the relatively unexplored role that chirality can play in electrokinetic phenomena.

Alanis, Kristen↗

Ultrasonic absorption in H2S

Ultrasonic absorption in hydrogen sulfide, measuring vibrational and rotational relaxation times as function of temperature

Bass, H. E.↗

Seismology of the moon and implications on internal structure, origin and evolution.

The objective of the passive seismic experiment is to measure vibrations of the lunar surface produced by all natural and artificial sources of seismic energy and to use these data to deduce the internal structure and constitution of the moon and the nature of tectonic processes which may be active within the moon. Lunar seismic signals are discussed together with the sources of these signals, and aspects of lunar structure and dynamics. Seismic signals from approximately 250 natural events and from two man-made impacts have been recorded during seven months of operation of the two seismic stations installed during Apollo missions 11 and 12.

Ewing, M.↗

Energy distribution among reaction products. IV.

Use of an infrared chemiluminescence technique, called 'Method II,' or the 'method of arrested relaxation' to measure the distribution of energy among products of the Cl + HI and Cl + DI reactions. Preliminary results are also given for the Br + HI and Cl + HBr reactions. Instead of measuring vibrational relaxation, Method II attempts to arrest vibrational and rotational relaxation by the rapid removal of excited products at a cold surface.

Maylotte, D. H.↗

A study of helicopter interior noise reduction

The interior noise levels of existing helicopters are discussed along with an ongoing experimental program directed towards reducing these levels. Results of several noise and vibration measurements on Langley Research Center's Civil Helicopter Research Aircraft are presented, including measurements taken before and after installation of an acoustically-treated cabin. The predominant noise source in this helicopter is the first stage planetary gear-clash in the main gear box, both before and after installation of the acoustically treated cabin. Noise reductions of up to 20 db in some octave bands may be required in order to obtain interior noise levels comparable to commercial jet transports.

Howlett, J. T.↗

Concorde Noise-Induced Building Vibrations, Montgomery County, Maryland

A series of studies are reported to assess the noise induced building vibrations associated with Concorde operations. The levels of induced vibration and associated indoor/outdoor noise levels resulting from aircraft and nonaircraft events in selected homes, historic and other buildings near Dulles International Airport were recorded. The building response resulting from aircraft operations was found to be directly proportional to the overall sound pressure level and approximately independent of the aircraft type. The noise levels and, consequently, the response levels were observed to be higher for the Concorde operations than for the CTOL operations. Furthermore, the vibration could be closely reproduced by playing aircraft noise through a loudspeaker system located near the vibration measurement location. Nonaircraft events such as door closing were again observed to result in higher response levels than those induced by aircraft.

Mayes, W. H.↗

An introduction to a unified approach to flexible rotor balancing

Two types of technique for flexible-rotor balancing are examined: the influence coefficient method, and the modal balancing method. Briefly, the influence coefficient method seeks those correction masses in a predetermined set of planes which will minimize measured vibration (readings) at a series of sensors and speeds, as predicted by influence coefficients relating vibration readings to mass additions; the influence coefficients are normally determined by a series of trial mass tests. The modal balancing method seeks to balance the rotor, one mode at a time, with a set of masses specifically selected not to disturb previously balanced lower modes, the sensitivity to this combination of masses is determined empirically by a series of trial mass tests. The two approaches are compared in supercritical-shaft balancing tests, and some common features are stressed for ultimate incorporation into a unified approach toward flexible-rotor balancing.