Revitalizing the Space Shuttle's Thermal Protection System with Reverse Engineering and 3D Vision Technology

The Space Shuttle is protected by a Thermal Protection System (TPS) made of tens of thousands of individually shaped heat protection tile. With every flight, tiles are damaged on take-off and return to earth. After each mission, the heat tiles must be fixed or replaced depending on the level of damage. As part of the return to flight mission, the TPS requirements are more stringent, leading to a significant increase in heat tile replacements. The replacement operation requires scanning tile cavities, and in some cases the actual tiles. The 3D scan data is used to reverse engineer each tile into a precise CAD model, which in turn, is exported to a CAM system for the manufacture of the heat protection tile. Scanning is performed while other activities are going on in the shuttle processing facility. Many technicians work simultaneously on the space shuttle structure, which results in structural movements and vibrations. This paper will cover a portable, ultra-fast data acquisition approach used to scan surfaces in this unstable environment.

Wilson, Brad↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

Introduction: Current exercise countermeasures on the International Space Station (ISS), including treadmill running, cycle ergometry, and resistive exercise, are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. Methods: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), Results: Eight subjects (2 Active [CEVIS + ARED], 6 Control) have been recruited for this study. Data collection is currently in progress. Conclusions: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

Introduction: Current exercise countermeasures on the International Space Station (ISS), including treadmill running, cycle ergometry, and resistive exercise, are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices that provide both aerobic and resistive training on one platform without including a treadmill, such as the European Enhanced Exploration Exercise Device (E4D). It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. Methods: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40) who will partake in nominal exercise on the ISS, including running on the treadmill with vibration isolation system 2 (T2), ergometry on the cycle ergometer with vibration isolation and stabilization device (CEVIS), and strength training on the advanced resistive exercise device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. Results: Data collection for this study is currently in progress. Conclusions: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

INTRODUCTION: Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. RESULTS: Thirteen subjects (3 Active [CEVIS + ARED], 10 Control) have been recruited for this study. Data collection is currently in progress. CONCLUSIONS: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

INTRODUCTION: Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. RESULTS: Thirteen subjects (3 Active [CEVIS + ARED], 10 Control) have been recruited for this study. Data collection is currently in progress. CONCLUSIONS: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Preliminary vibration design and test criteria considerations for the space shuttle

This paper presents some Marshall Space Flight Center preliminary vibration design and test criteria considerations for the space shuttle. The discussion is primarily concerned with the formulation of vibration criteria for the design and testing of the equipment installations on the shuttle. A recommended criteria format is presented with a discussion of when the vibration environment has to be considered in design and testing. A semiempirical method of predicting the vibration criteria for the shuttle from vibroacoustic structural data banks is presented. Some preliminary vibration criteria predictions are presented for the orbiter and booster equipment bays and for the main shuttle engine. A research testing program to determine the vibroacoustic transfer through a typical shuttle thermal protection system (TPS) panel configuration is described.

Harry J. Bandgren↗

Support For Fragile Borescopes

Fixture supports thin borescopes during inspections through 0.0405-in. orifices. Porescopes, which have diameter of 0.037 in., extremely fragile and often fractured during inspections, contaminating inspected cavitites with debris. Nylon guide tip and acrylic support sleeve and body protect and guide a fragile borescope. Support sleeve press-fitted on body and removed when little clearance around orifice inspected. Otherwise, it helps to stablize fixture. Helps to prevent damage caused by vibrations and eliminates constantly moving view that afflicts unsupported small-diameter borescopes.

Brown, William S.↗

Thermally Insulating, Kinematic Tensioned-Fiber Suspension

A salt pill and some parts of a thermally insulating, kinematic suspension system that holds the salt pill rigidly in an adiabatic-demagnetization refrigerator (ADR) is presented. "Salt pill" in this context denotes a unit comprising a cylindrical container, a matrix of gold wires in the container, and a cylinder of ferric ammonium alum (a paramagnetic salt) that has been deposited on the wires. The structural members used in this system for both thermal insulation and positioning are aromatic polyamide fibers (Kevlar(R) or equivalent) under tension. This suspension system is designed to satisfy several special requirements to ensure the proper operation of the ADR. These requirements are to (1) maintain the salt pill at a specified position within the cylindrical bore of an electromagnet; (2) prevent vibrations, which would cause dissipation of heat in the salt pill; and (3) minimize the conduction of heat from the electromagnet bore and other neighboring objects to the salt pill; all while (4) protecting the salt pill (which is fragile) against all tensile and bending loads other than those attributable to its own weight. In addition, the system is required to consist of two subsystems -- one for the top end and one for the bottom end of the salt pill -- that can be assembled and tensioned separately from each other and from the salt pill, then later attached to the salt pill.

Voellmer, George M.↗

An Assessment of Using Vibrational Compaction of Calcined HLW and LLW in DWPF Canisters

Since 1963, the INEL has calcined almost 8 million gallons of liquid mixed waste and liquid high-level waste, converting it to some 1.1 million gallons of dry calcine (about 4275.0 m3), which consists of alumina-and zirconia-based calcine and zirconia-sodium blend calcine. In addition, if all existing and projected future liquid wastes are solidified, approximately 2,000 m3 of additional calcine will be produced primarily from sodium-bearing waste. Calcine is a more desirable material to store than liquid radioactive waste because it reduces volume, is much less corrosive, less chemically reactive, less mobile under most conditions, easier to monitor and more protective of human health and the environment. This paper describes the technical issue involved in the development of a feasible solution for further volume reduction of calcined nuclear waste for transportation and long term storage, using a standard DWPF canister. This will be accomplished by developing a process wherein the canisters are transported into a vibrational machine, for further volume reduction by about 35%. The random compaction experiments show that this volume reduction is achievable. The main goal of this paper is to demonstrate through computer modeling that it is feasible to use volume reduction vibrational machine without developing stress/strain forces that will weaken the canister integrity. Specifically, the paper presents preliminary results of the stress/strain analysis of the DWPF canister as a function of granular calcined height during the compaction and verifying that the integrity of the canister is not compromised. This preliminary study will lead to the development of better technology for safe compactions of nuclear waste that will have significant economical impact on nuclear waste storage and treatment. The preliminary results will guide us to find better solutions to the following questions: 1) What are the optimum locations and directions (vertical versus horizontal or both of them) of applying the vibrational forces? 2) What is best mode of operation: first fill the canister with calcined waste and then vibrate it and refill it again, or apply vibrational forces during the filling process. By optimum or best we mean less creation of stress/strain forces during the volume reduction vibration process. Lessons learnt: This preliminary study shows that; 1) The maximum stress concentration always occurs in the canister wall, however its location varies and depends on the loading condition, and vibration process. 2) The proposed vibrational process would not cause any damages to the granulated calcined waste. 3) The first natural frequency of the longitudinal vibration of the canister is around 400 Hz, which is far away from the applied vibrational frequencies and from possibility of resonance phenomena that may cause damage to the canister 4) The relationship between the maximum internal stress and the frequency of the applied load is not parabolic. 5) The mechanical properties of the granulated calcined nuclear waste have small impact on the internal stress of the canister. Finally, the calculated data suggested that applying vibrational forces will keep the entire canister whole without any indication of development defects, and will have significant economical benefits of handling HLW and LLW in calcined forms, from waste manipulation, storage and transportation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrating superconducting phase and topological crystalline quantum spin Hall effect in hafnium intercalated gallium film

Motivated by the growth of superconducting atomic hexagonal Ga layers on GaN surface we have calculated the electronic properties of Hf intercalated honeycomb Ga layers using first-principles theory. In contrast to the hexagonal Ga layers where substrate is necessary for their stability, we find the above structure to be dynamically stable in its freestanding form with small formation energy. In particular, six Dirac cones composed of Hf-d{sub xy}/d{sub x2-y2} orbitals are observed in the first Brillouin zone, slightly below the Fermi energy. Spin-orbit coupling opens a large band gap of 177 meV on these Dirac cones. By calculating its mirror Chern number, we demonstrate that this band gap is topologically nontrivial and protected by mirror symmetry. Such mirror symmetry protected band gaps are rare in hexagonal lattice. A large topological crystalline quantum spin Hall conductance σ{sub SH} ∼ −4 e{sup 2}/h is also revealed. Moreover, electron-phonon coupling calculations reveal that this material is superconducting with a transition temperature T{sub c} = 2.4 K, mainly contributed by Ga out-of-plane vibrations. Our results provide a route toward manipulating quantum spin Hall and superconducting behaviors in a single material which helps to realize Majorana fermions and topological superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sputter-Coated TiO 2 Films as Passivation and Hole Transfer Layers for Improved Energy Conversion with Solar Fuel WO 3 /CuWO 4 Photoanodes

Atomic layer deposited (ALD) “leaky” TiO 2 have gained interest as charge-selective protection layers for semiconductor solar fuel electrodes. Here we demonstrate the use of sputter-deposited TiO 2 layers as hole selective contacts for WO 3 /CuWO 4 type 2 heterojunction water oxidation photoanodes for the first time. TiO 2 protection layers with varying thicknesses (2 to 128 nm) were deposited using the RF magnetron sputtering technique. The resulting TiO 2 films are amorphous based on Raman spectroscopy and powder XRD. Photoelectrochemical scans and Vibrating Kelvin probe photovoltage spectroscopy show that 2-8 nm TiO 2 layers nearly double the photocurrent to 0.97 mA cm -2 under AM 1.5 illumination (19% AQE at 350 nm), increase the surface photovoltage signal by 25%, and increase the WO 3 /CuWO 4 bandgap. These effects can be attributed to the selectivity of TiO 2 for photoholes. Additionally, SPV data suggest that TiO 2 overlayers suppress copper-based surface recombination defects. Reduced photocurrent and the photovoltage are seen in thicker TiO 2 films (16 to 128 nm) as a result of an increasing hole transfer resistance and because of light shading effects according to photoaction spectra. The TiO 2 films also improve the stability of the WO 3 /CuWO 4 photoelectrodes, allowing nearly constant O 2 evolution over 3 hours after an initial 20-35% loss. Overall, this work establishes RF magnetron sputtering as a useful method to install amorphous TiO 2 passivation layers for improved WO 3 /CuWO 4 solar fuel photoelectrodes. Furthermore, we show how the combination of PEC with SPV measurements provides insight into the function of the TiO 2 coatings.

CuWO4↗

Unsteady environments and responses of the shuttle combined loads orbiter test

Both separate and combined wind tunnel and vibration shaker tests were conducted on two structural panels representative of the Shuttle orbiter in the NASA LaRC 8-foot transonic pressure tunnel (TPT) to determine the effects of combined loads on the thermal protection system (TPS). The primary objective of this test was to provide a combined full-scale load environment and realistic time history of the dynamic pressures, Mach numbers (through transonic), and dynamic structural responses of these panels. The panels were selected from orbiter locations where interactive load sources such as aerodynamic shock waves, turbulent boundary layers, strut-induced vorticity, and substrate deformation combined to provide high bonding loads between the TPS and the orbiter structure. The test panels for this program were highly instrumented with static and dynamic pressure gages, accelerometers, deflectometers, strain gages, Schileren and high-speed photography, and special instrumentation necessary to determine TPS/structure interface loads and tile motions. Two test specimens of each orbiter panel were utilized. Both were high-fidelity representations of the selected orbiter location. The first panel (calibration panel) for each test was utilized to calibrate the tunnel and shaker system as well as provide a data-gathering source for applied static and dynamic loads. The second panel (test panel) for each test was subjected to flight time exposures only so that TPS characteristics as a function of flight mission exposure could be determined. These tests were the last in a series that was suce6ssfully completed and necessary to certify the TPS prior to the first launching of the Shuttle.

P. H. Schuetz↗

Protecting the Protectors

Program Manager Kurt Silvers helped protect the safety of U.S. troops who fought in Iraq and Afghanistan. PNNL researchers developed technology that monitored the battle-readiness of Hellfire II missiles onboard Army Apache helicopters. The technology continually monitors factors like vibration and temperature, providing key data when making decisions to deploy or retire weapons.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Gold–Thiolate Nanocluster Dynamics and Intercluster Reactions Enabled by a Machine Learned Interatomic Potential

Monolayer protected metal clusters comprise a rich class of molecular systems and are promising candidate materials for a variety of applications. While a growing number of protected nanoclusters have been synthesized and characterized in crystalline forms, their dynamical behavior in solution, including prenucleation cluster formation, is not well understood due to limitations both in characterization and first-principles modeling techniques. Recent advancements in machine-learned interatomic potentials are rapidly enabling the study of complex interactions such as dynamical behavior and reactivity on the nanoscale. Here, we develop an Au-S-C-H atomic cluster expansion (ACE) interatomic potential for efficient and accurate molecular dynamics simulations of thiolate-protected gold nanoclusters (Au n (SCH 3 ) m ). Trained on more than 30,000 density functional theory calculations of gold nanoclusters, the interatomic potential exhibits ab initio level accuracy in energies and forces and replicates nanocluster dynamics including thermal vibration and chiral inversion. Long dynamics simulations (up to 0.1 μs time scale) reveal a mechanism explaining the thermal instability of neutral Au 25 (SR) 18 clusters. Specifically, we observe multiple stages of isomerization of the Au 25 (SR) 18 cluster, including a chiral isomer. Additionally, we simulate coalescence of two Au 25 (SR) 18 clusters and observe series of clusters where the formation mechanisms are critically mediated by ligand exchange in the form of [Au-S] n rings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Space Shuttle Program Progress Report

A status report is presented on progress in the design, manufacturing and testing of components of the space transportation system (STS), and primarily the Space Shuttle vehicles. Project landmarks from 1969 to 1981 are indicated, fabrication of the Shuttle Orbiter and rollout of the first prototype are described, fabrication and assembly of some Orbiter parts are sketched, and some of the subsystems (thermal protection, avionics, maneuvering aids, reaction control, remote manipulator) are described. Also discussed are: Orbiter carrier aircraft, Shuttle main engine and tests, external fuel tank, solid rocket booster, launch and landing facilities. A separate section is devoted to ground tests (vibration, propulsion, electronics, avionics integration), trainers and simulators, and flight tests (captive flight, free flight, landing and approach, orbital flight).

Thompson, R. F.↗

SU-E-T-349: Verification of a Monte Carlo Simulation Tool as a Second Check for TomoTherapy Treatment Planning

Purpose: To verify a virtual source model used in Monte Carlo (MC) TomoTherapy simulations and to provide a tool for the dose distribution second check for TomoTherapy treatment planning. Methods: Published studies adopted the full MC model to simulate helical TomoTherapy which use phase space files (PSFs) at different scoring planes to facilitate patient dose calculations. We have developed a simple virtual source model (VSM) based on the commissioning data of helical TomoTherapy unit which can be exported from the treatment planning station (TPS). To calculate the patient dose distribution, TPS-generated sinograms are extracted from archived patient XML files and fluence maps are created by incorporating the openclose leaf time with leaf filter, jaw penumbra, and leaf latency. The VSM has been validated for various geometrical set-ups including open fields, heterogeneous media and clinical DQA cases. Results: Good agreement was obtained between our VSM and a published full MC model for the test case of heterogeneous media. For the complex clinical head and neck (HN) case, the MC simulation of the DQA plan agreed with the film measurement with 98% of planar dose pixels passing the 2%/2 mm gamma value test. For the patient treatment plan itself, the MC simulation showed comparable DVHs for the planning target volumes (PTVs) and organs-at-risk (OARs). Deviations observed were consistent with literature. Conclusion: The proposed VSM can be used in the MC method to accurately simulate the patient dose distributions for helical TomoTherapy.

60 APPLIED LIFE SCIENCES↗

Rubber-coated bellows improves vibration damping in vacuum lines

Compact-vibration damping systems, consisting of rubber-coated metal bellows with a sliding O-ring connector, are used in vacuum lines. The device presents a metallic surface to the vacuum system and combines flexibility with the necessary stiffness. It protects against physical damage, reduces fatigue failure, and provides easy mating of nonparallel lines.

Hegland, D. E.↗

Navier-Stokes solutions with surface catalysis for Martian atmospheric entry

In this study numerical solutions have been obtained for two-dimensional axisymmetric hypersonic nonequilibrium CO2 flow over a high angle blunt cone with appropriate surface boundary conditions to account for energy and mass conservation at the body surface. The flowfield is described by the Navier-Stokes equations and multicomponent conservation laws which account for both translational and internal vibrational nonequilibrium effects. Complete forebody solutions have been obtained for the peak heating point of the Mars entry trajectory specified in the proposed NASA MESUR (Mars Environmental Survey) project. In these solutions, radiative equilibrium wall temperature and surface heating distributions are determined over the MESUR aeroshell forebody for entry velocity equal to 7 km/sec with varying degrees of surface catalysis. The effects of gas kinetics, surface catalysis, transport properties, and vibrational relaxation times on the surface heating are examined. The results identify some important issues in the prediction of surface heating for flows in thermochemical nonequilibrium and show that the Navier-Stokes code used herein is effective for thermal protection system design and materials selection.

Chen, Y.-K.↗