A doublet lattice method for the determination of rotor induced empennage vibration airloads. Analysis description and program documentation

An efficient state-of-the-art method was developed to determine the unteady vibratory airloads produced by the interaction of the main rotor wake with a helicopter empennage. This method was incorporated into a computer program, Rotor Induced Empennage Vibration Analysis (RIEVA). The program requires the main rotor wake position and the strength of the vortices locates near the empennage surfaces. A nonlinear lifting surface analysis is utilized to predict the aerodynamic loads on the empennage surfaces in the presence of these concentrated vortices. The analysis was formulated to include all pertinent effects such as suction of the interacting vortices and the shed vorticity behind the empennage surfaces. The analysis employs a time domain solution. The output of the program consists of chordwise and spanwise airload distributions on the empennage surfaces. The airload distributions are harmonically analyzed and formulated for input into the Coupled Rotor/Airframe Vibration Analysis.

Gangwani, S. T.↗

Optical Measurements of Axial and Tangential Steady-State Blade Deflections Obtained Simultaneously

Case-mounted fiber-optic sensors have been used by aircraft engine manufacturers mainly to monitor blade vibration in fans and compressors. The simplest probe arrangement is a spot probe where, typically, a center fiber transmits laser light, and the outer fibers collect the reflected light from the blade tips and transmit it to a photodetector. Because the spot of incident light is fixed in space, whereas the blade deflects dynamically, the reflected light will originate from slightly different portions of the blade tip under different operating conditions. Unless corrections are developed to compensate for this effect, some error in vibratory tangential amplitude will occur. For monitoring vibrations, this error is usually not critical. However, when steady-state blade deflections are being measured, it is very important to fix the spot on the blade tip at a particular location because the operating speed blade deflections are evaluated against a low-speed reference run. The change in speed usually implies a significant change in the blade orientation and possibly its shape brought about by the aerodynamic and centrifugal loading. It is most convenient to select the blade s leading and trailing edges as the fixed points for which deflections will be evaluated. To capture the blade edges at various speeds, the light probe must be movable. This was achieved by mounting the probe in an eccentric hole in a bushing that fit the fan case in the region that overlapped the path of the blade edge. The probe was actuated to search for a blade edge while all the blades were viewed on an oscilloscope. The blade edge was considered to be captured when a pulse associated with a particular blade was significantly reduced in magnitude but was clearly distinguishable from the background noise level. By tracing the axial position of either blade edge, one could extend the deflection measurement to two dimensions: axial and tangential. These blade deflection measurements were obtained during a wind tunnel test of a fan prototype.

Kurkov, Anatole P.↗

Differences in Mechanical Properties of the Human and Monkey Tibia

A method which uses an instrument that detects the response of a long bone to a vibratory stimulus to quantify mechanical properties non-invasively was revised and validated for use in the tibia. Stored data from healthy men was reanalyzed and compared with values from non-human primates. The analysis uses the relationship K(sub b) = 48 EI/L(sup 3) where K(sub b) is the lateral stiffness of a beam with force applied midspan, E is the elastic modulus, I the geometric moment of inertia and L, the limb length. Values for stiffness (EI, Nm(sup2)), the Euler buckling load (P(sub cr) = EI (pi/L)(sup 2)), and bone sufficiency (S) which represents the axial load the bone can support, adjusted to BW (S=P(sub cr)/BW) were obtained. The interest precision of the method in relaxed men, 5.8%, and in sedated male monkeys, 4.3%, was based on repeated measures in the same subjects at 1 month intervals. The R tibias of 40 men, aged 38.6 +/- 7.3 yrs with BW 78.9 +/- 7.9 kg, showed average (+/- SD) L to be 35 +/- 2 cm, EI 222 +/- 71 Nm(sup 2), P(sub cr) 18.1 +/- 4.9 kN, and S 23.4 +/- 5.7 N. The R tibias of 24 Rhesus monkeys ranging in age from 2-12 years, BW 4.9 +/- 3 kg, showed L to be 14.7 +/- 1.9 cm, EI 6.0 +/- 4.8 Nm(sup 2), P(sub cr) 2.51 +/- 1.2 kN and S 57.3 N. These measurements indicate that the tibia of a terrestrial non-human primate, M. mulatta, has higher load carrying capacity for the level of body weights in the species than the human bone.

Arnaud, Sara B.↗

Packing Optimization of an Intentionally Stratified Sorbent Bed Containing Dissimilar Media Types

The Fire Cartridge is a packed bed air filter with two different and separate layers of media designed to provide respiratory protection from combustion products after a fire event on the International Space Station (ISS). The first layer of media is a carbon monoxide catalyst made from gold nanoparticles dispersed on iron oxide. The second layer of media is universal carbon, commonly used in commercial respirator filters. Each layer must be optimally packed to effectively remove contaminants from the air. Optimal packing is achieved by vibratory agitations. However, if post-packing movement of the media within the cartridge occurs, mixing of the bed layers, air voids, and channeling could cause preferential air flow and allow contaminants to pass. Several iterations of prototype fire cartridges were developed to reduce post-packing movement of the media within each layer (settling), and to prevent mixing of the two media types. Both types of movement of the media contribute to decreased fire cartridge performance. Each iteration of the fire cartridge design was tested to demonstrate mechanical loads required to cause detrimental movement within the bed, and resulting level of functionality of the media beds after movement was detected. In order to optimally pack each layer, vertical, horizontal, and orbital agitations were tested and a final packed bulk density was calculated for each method. Packed bulk density must be calculated for each lot of catalyst to accommodate variations in particle size, shape, and density. In addition, a physical divider sheet between each type of media was added within the fire cartridge design to further inhibit intermixing of the bed layers.

Kidd, Jessica↗

Nanoelectric Materials Laboratory Development

The Ultracapacitor Research and Development project is a collaborative effort between the NASA Marshall Space Flight Center's (MSFC's) ES43 Parts, Packaging, and Fabrication Branch and the EM41 Nonmetallic Materials Branch. NASA's Ultracapacitor Research is an effort to develop solid-state energy storage devices through processing of ceramic materials into printable dielectric inks, which can be formed and treated to produce solid state ultracapacitor cells capable of exceeding lithium-ion battery energy density at a fraction of the weight. Research and development efforts into solid state ultracapacitors have highlighted a series of technical challenges such as understanding as-received nature of ceramic powders, treatment and optimization of ceramic powders, dielectric and conductor ink formulation, and firing of printed (green) ultracapacitor cells. Two facilities have been continually developed since project inception: the Additive Electronics Lab in Bldg. 4487 and the Nanoelectric Materials Lab in Bldg. 4602. The Nanoelectric Materials Lab has become a unique facility at MSFC, capable of custom processing a wide range of media for additive electronics. As research has progressed, it was discovered that additional in-house processing was necessary to achieve smaller, more uniform particle diameters. A vibratory mill was obtained that can agitate powder and media in three directions, which has shown to be much more effective than ball milling. However, in order to understand the effects of milling, a particle size analysis system has been installed to characterize as-received and milled materials Continued research into the ultracapacitor technology included advanced milling and optimization of ceramic nanoparticles, fluidized bed treatment of atomic-layer deposition- (ALD-) coated ceramic particles, custom development of dielectric and conductor inks, as well as custom ink precursors such as polyvinylidene diflouride- (PVDF-) loaded vehicles. Experiments with graphene-based inks were also conducted.

Allen, Lee↗

Fretting Wear of Ti-48Al-2Cr-2Nb

An investigation was conducted to examine the wear behavior of gamma titanium aluminide (Ti-48Al-2Cr-2Nb in atomic percent) in contact with a typical nickel-base superalloy under repeated microscopic vibratory motion in air at temperatures from 296-823 K. The surface damage observed on the interacting surfaces of both Ti-48Al-2Cr-2Nb and superalloy consisted of fracture pits, oxides, metallic debris, scratches, craters, plastic deformation, and cracks. The Ti-48Al-2Cr-2Nb transferred to the superalloy at all fretting conditions and caused scuffing or galling. The increasing rate of oxidation at elevated temperatures led to a drop in Ti-48Al-2Cr-2Nb wear at 473 K. Mild oxidative wear was observed at 473 K. However, fretting wear increased as the temperature was increased from 473-823 K. At 723 and 823 K, oxide disruption generated cracks, loose wear debris, and pits on the Ti-48Al-2Cr-2Nb wear surface. Ti-48Al-2Cr-2Nb wear generally decreased with increasing fretting frequency. Both increasing slip amplitude and increasing load tended to produce more metallic wear debris, causing severe abrasive wear in the contacting metals. Keywords

Miyoshi, Kazuhisa↗

Assessment of Comprehensive Analysis Calculation of Structural Loads on Rotors

Blade flap bending moments are investigated for six rotors operating at transition and high speeds: H-34 in flight and wind tunnel, SA 330 (research Puma), SA 349/2, UH-60A full-scale, and BO-105 model (HART-I). The measured data from flight and wind tunnel tests are compared with calculations obtained using the comprehensive analysis CAMRAD II. The calculations mere made using two free wake models: rolled-up and multiple-trailer with consolidation models. At transition speed, there is fair to good agreement for the flap bending moment between the test data and analysis for the H-34, research Puma, and SA 349/2 with the rolled-up wake. The calculated flap bending moments differ significantly from measurements for the UH-60A and BO-105. Better correlation is obtained for the UH-60A by using the multiple-trailer with consolidation wake model. Although the multiple-trailer with consolidation wake model shows good correlation on the normal force for the BO-105, the same analysis shows poor correlation on the flap bending moment. In the high speed condition, the analysis shows generally good agreement with the research Puma flight data in both magnitude and phase. However, poor agreement is obtained for the other rotors examined. Although the analysis significantly underpredicts the vibratory normal force on the advancing side for the H-34, the vibratory bending moment correlation is fair to good on both magnitude and phase.

Yeo, Hyeonsoo↗

Comparison of Different Measurement Technologies for the In-Flight Assessment of Radiated Acoustic Intensity

A series of tests was planned and conducted in the Interior Noise Test Facility at Boeing Field, on the NASA Aries 757 flight research aircraft, and in the Structural Acoustic Loads and Transmission Facility at NASA Langley Research Center. These tests were designed to answer several questions concerning the use of array methods in flight. One focus of the tests was determining whether and to what extent array methods could be used to identify the effects of an acoustical treatment applied to a limited portion of an aircraft fuselage. Another focus of the tests was to verify that the arrays could be used to localize and quantify a known source purposely placed in front of the arrays. Thus the issues related to backside sources and flanking paths present in the complicated sound field were addressed during these tests. These issues were addressed through the use of reference transducers, both accelerometers mounted to the fuselage and microphones in the cabin, that were used to correlate the pressure holograms. measured by the microphone arrays using either SVD methods or partial coherence methods. This correlation analysis accepts only energy that is coherent with the sources sensed by the reference transducers, allowing a noise control engineer to only identify and study those vibratory sources of interest. The remainder of this paper will present a detailed description of the test setups that were used in this test sequence and typical results of the NAH/IBEM analysis used to reconstruct the sound fields. Also, a comparison of data obtained in the laboratory environments and during flights of the 757 aircraft will be made.

Klos, Jacob↗

Effect of Vacuum on Force Response of an Ultrasonic Penetrator

Introduction: The Apollo astronauts encountered higher than expected resistances when interacting with the lunar soil via the Apollo Lunar Surface Drill (ALSD) and the trenching tool. Reducing the force required to move tools or other mechanical components through regolith will impact many steps of the resource extraction process. Force reduction has been achieved in soil materials by imparting vibration to tooling interfaces such as a vibratory farming cultivator, a percussive scoop, and ultrasonically resonant penetrators. Vibration-assisted tools in granular media reduce interaction forces by fluidizing a volume around the tool, allowing the tool to progress through a dynamic (fluid) medium instead of a static (solid) medium. This work seeks to quantify ultrasonic vibration’s effect on the force response of a penetrator in lunar soil simulant in vacuum sufficient to be within the molecular flow regime of any disturbed gases. Methods: A custom vacuum chamber setup, CUBEvac, was designed and built to facilitate penetration testing in a high vacuum environment, for comparison to penetration behavior in ambient terrestrial environment. A two-stage pumping system (Agilent Triscroll 600 roughing pump, Agilent VHS-6 oil diffusion pump) reached chamber pressures of about 5x10-6 Torr with regolith simulant in place. Figure 1 is a schematic of the heart of the assembly (note the penetration drive mechanisms above the chamber feedthrough and the regolith simulant sample in the bottom are not shown). The penetration actuation stack was comprised of a stepper motor driving a lead screw to move the ultra-sonic probe vertically inside the chamber. Motion was coordinated with an Arduino Uno. GRC-3 lunar simulant was used for this set of experiments. Samples were prepared in a four-liter stain-less steel, cylindrical pot with an internal diameter of approximately 15.56 cm (6.125 in) and a depth of 19.37 cm (7 5/8 in) for testing. The soil was baked out prior to compaction preparation as a measure to reduce soil moisture which interfered with pump down capacity. The soil was not baked again if it was removed from the vacuum chamber, prepped, and immediately returned to the vacuum chamber for pump down. The soil was compacted using a 60 Hz vibration table with a surcharge of 34 kg place on top of the soil in the container. Prepared soil samples weighed approximately 6.5 kg (bulk density 1.895-1.934 g/cm3). Two probe end effectors were tested: A cone penetrometer (static only) with a nominal diameter of 12.7 mm (0.5 in) and a nominal height of 28.6 mm (1.125 in); and a vibrating cylindrical probe measuring 12.7 mm in diameter and 50.8 mm in effective length from the tip (Figure 2). The cylindrical probe vibrated resonantly at 20 kHz with an amplitude 23 μm. The cone penetration tests were conducted to assess potential soil behavior differences in vacuum. The cylinder probe tests were conducted as the primary subject of this investigation to assess force response in vacuum. For each test, a regolith simulant sample was load-ed and compacted in the chamber, which was then evacuated for roughly 18 hours to reach the lowest possible pressure (approximately 5x10-6 Torr for most tests). The probe was then moved to about 10 mm above the soil surface before being pushed to a depth of 50 mm for the cylinder probe tests and to a depth of 100 mm for the cone penetrometer tests, both at a speed of 2 mm/s. The simulant samples were prepared the same for all tests. Ideally, they would respond consistently to probe penetration under ambient and vacuum conditions. This was evaluated by measuring the resistance of representative prepared simulant beds with a standard cone penetrometer in both environments. Results and Discussion: The resistance of the simulant samples in the vacuum tests was consistently lower than in the ambient tests as determined by the cone penetration tests. Thus, the ambient and vacuum results cannot be compared directly; work is underway to de-confound and better correlate the data. Still, figures 3-6 show that probe penetration forces are lower overall in the vacuum environment. In both environments, resonant vibration of the probe provides two useful effects: It reduces the probe penetration force and smooths the force-depth curve, significantly reducing local maxima. These effects have implications for various potential applications, such as astronaut hand-tools, where benefits (reducing astronaut effort) outweigh the cost of the additional energy re-quired to generate vibration. These results demonstrate that resonantly vibrating tools can meaningfully reduce the penetration force required for excavation, probing, and drilling tools in simulated lunar regolith deposits under vacuum levels approaching those that will be experience on the Moon’s surface. Lunar-gravity, ambient environment tests are scheduled soon. The effects of realistic temperatures and temperature gradients and deeper vacuum remain to be tested.

E Rezich↗