Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vacuum apparatus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

High frequency, high power capacitor development

A program to develop a special high energy density, high power transfer capacitor to operate at frequency of 40 kHz, 600 V rms at 125 A rms plus 600 V dc bias for space operation. The program included material evaluation and selection, a capacitor design was prepared, a thermal analysis performed on the design. Fifty capacitors were manufactured for testing at 10 kHz and 40 kHz for 50 hours at Industrial Electric Heating Co. of Columbus, Ohio. The vacuum endurance test used on environmental chamber and temperature plate furnished by Maxwell. The capacitors were energized with a special power conditioning apparatus developed by Industrial Electric Heating Co. Temperature conditions of the capacitors were monitored by IEHCo test equipment. Successful completion of the vacuum endurance test series confirmed achievement of the main goal of producing a capacitor or reliable operation at high frequency in an environment normally not hospitable to electrical and electronic components. The capacitor developed compared to a typical commercial capacitor at the 40 kHz level represents a decrease in size and weight by a factor of seven.

White, C. W.↗

Thermal Shock-Resistant Composite Crucible

Heating rates of 350 degrees F per minute have not caused cracking. Surrounding inner crucible is annulus of loosely packed alumina powder, which serves as compressible insulating material. Second annulus consisting of section of fused-quartz tubing surrounds and retains alumina powder. Quartz tube held in place by refractory cement helps to contain alumina powder. Small holes in upper ring of cement allow alumina powder to outgas during operation in vacuum. Originally intended for use in Chill Block Melt Spinning (CBMS) apparatus, crucible adaptable to other operations involving rapid self-induction heating of metallic charges.

Geringer, H. J.↗

Device Applies Films to Optical Elements

Clamping device applies protective or antireflective dielectric coating to lenses or other optical elements. Alternative version of device applies thin sheet of dielectric film to ring or stretches it for clamping in holder to form pellicle or beam splitter. Defects avoided by new apparatus, which uniformly stretches dielectric films in radial direction and creates vacuum between them before thermally bonded to optical element.

Augason, Gordon C.↗

Radio Frequency Trap for Containment of Plasmas in Antimatter Propulsion Systems Using Rotating Wall Electric Fields

A containment apparatus for containing a cloud of charged particles comprises a cylindrical vacuum chamber having a longitudinal axis. Within the vacuum chamber is a containment region. A magnetic field is aligned with the longitudinal axis of the vacuum chamber. The magnetic field is time invariant and uniform in strength over the containment region. An electric field is also aligned with the longitudinal axis of the vacuum chamber and the magnetic field. The electric field is time invariant, and forms a potential well over the containment region. One or more means are disposed around the cloud of particles for inducing a rotating electric field internal to the vacuum chamber. The rotating electric field imparts energy to the charged particles within the containment region and compress the cloud of particles. The means disposed around the outer surface of the vacuum chamber for inducing a rotating electric field are four or more segments forming a segmented ring, the segments conforming to the outer surface of the vacuum chamber. Each of the segments is energized by a separate alternating voltage. The sum of the voltages imposed on each segment establishes the rotating field. When four segments form a ring, the rotating field is obtained by a signal generator applying a sinusoidal signal phase delayed by 90,180 and 270 degrees in sequence to the four segments.

Sims, William Herbert, III↗

NASA Tech Briefs, December 2005

Topics covered include: Video Mosaicking for Inspection of Gas Pipelines; Shuttle-Data-Tape XML Translator; Highly Reliable, High-Speed, Unidirectional Serial Data Links; Data-Analysis System for Entry, Descent, and Landing; Hybrid UV Imager Containing Face-Up AlGaN/GaN Photodiodes; Multiple Embedded Processors for Fault-Tolerant Computing; Hybrid Power Management; Magnetometer Based on Optoelectronic Microwave Oscillator; Program Predicts Time Courses of Human/ Computer Interactions; Chimera Grid Tools; Astronomer's Proposal Tool; Conservative Patch Algorithm and Mesh Sequencing for PAB3D; Fitting Nonlinear Curves by Use of Optimization Techniques; Tool for Viewing Faults Under Terrain; Automated Synthesis of Long Communication Delays for Testing; Solving Nonlinear Euler Equations With Arbitrary Accuracy; Self-Organizing-Map Program for Analyzing Multivariate Data; Tool for Sizing Analysis of the Advanced Life Support System; Control Software for a High-Performance Telerobot; Java Radar Analysis Tool; Architecture for Verifiable Software; Tool for Ranking Research Options; Enhanced, Partially Redundant Emergency Notification System; Close-Call Action Log Form; Task Description Language; Improved Small-Particle Powders for Plasma Spraying; Bonding-Compatible Corrosion Inhibitor for Rinsing Metals; Wipes, Coatings, and Patches for Detecting Hydrazines; Rotating Vessels for Growing Protein Crystals; Oscillating-Linear-Drive Vacuum Compressor for CO2; Mechanically Biased, Hinged Pairs of Piezoelectric Benders; Apparatus for Precise Indium-Bump Bonding of Microchips; Radiation Dosimetry via Automated Fluorescence Microscopy; Multistage Magnetic Separator of Cells and Proteins; Elastic-Tether Suits for Artificial Gravity and Exercise; Multichannel Brain-Signal-Amplifying and Digitizing System; Ester-Based Electrolytes for Low-Temperature Li-Ion Cells; Hygrometer for Detecting Water in Partially Enclosed Volumes; Radio-Frequency Plasma Cleaning of a Penning Malmberg Trap; Reduction of Flap Side Edge Noise - the Blowing Flap; and Preventing Accidental Ignition of Upper-Stage Rocket Motors.

Source record↗

Methods of Testing Thermal Insulation and Associated Test Apparatus

The system and method for testing thermal insulation uses a cryostatic insulation tester having a vacuum chamber and a cold mass including a test chamber and upper and lower guard chambers adjacent thereto. The thermal insulation is positioned within the vacuum chamber and adjacent the cold mass. Cryogenic liquid is supplied to the test chamber, upper guard and lower guard to create a first gas layer in an upper portion of the lower guard chamber and a second gas layer in an upper portion of the test chamber. Temperature are sensed within the vacuum chamber to test the thermal insulation.

Fesmire, James E.↗

Below Ambient and Cryogenic Thermal Testing

Methods and apparatus for the testing of below-ambient temperature thermal insulation systems have been developed based on boiloff calorimetry. Boiloff calorimetry provides a direct measure of heat flow for below-ambient temperature conditions. The effective thermal conductivity (ke) and heat flux (q) of a test specimen are calculated for a fixed environmental condition (warm boundary temperature; cold boundary temperature; ambient or vacuum pressure). Through its heat of vaporization, liquid nitrogen (LN2) serves as the energy meter. Different apparatus have been built for flat-plate, cylindrical, and pipeline test specimens. Boundary temperatures can range from 353 K down to 77 K (80 C to -196 C). By interposing different insulation layers on the cold boundary, the cryogenic boiloff method is suitable for a wide range of below-ambient temperature applications. A cylindrical apparatus, Cryostat-100, as well as the pipeline test apparatus, Cryostat-P100, are thermally guarded and directly measure absolute thermal performance in watts. Pipe insulation systems can be mechanical, double-walled, or vacuum-jacketed including materials such as foams, cellular glass, aerogel blankets, clam-shell panels, and multilayer insulation. Two test pipelines, 12-meter-long, are mounted between two cold box assemblies. The test pipeline diameter is from 25-mm to 76-mm while the maximum outside diameter including insulation is up to 204-mm. The cold pipe tester design and test methods are discussed, as well as results for select thermal insulation materials. Progress toward a comparative type, bench-top cold pipe tester (Cryostat-P200) is also discussed.

Fesmire, James E.↗

Development, fabrication and testing of a magnetically connected plastic vacuum probe surface sampler

The sampler utilizes permanent magnets and soft metal pole pieces to connect the cone/filter assembly to the sampling head and vacuum supply. The cone/filter assembly is packaged in a plastic container and presterilized so that the need for any human contact during the sampling procedure is completely eliminated. Microbiological tests have demonstrated that the sampling efficiency is not affected by the magnetic coupling apparatus and that the probe appears to function as efficiently as the conventional plastic and Sandia vacuum probes.

Phillips, G. B.↗

Method and apparatus for fluffing, separating, and cleaning fibers

A perforated tube is housed in a chamber in which vacuum is drawn. An air jet is directed into one end of the tube and fiber bundles are fed into the jet which separates and dispenses individual fibers from the bundle, fluffs them, cleanses them of any particulate material, and carries them into the tube. The tube retains the fibers while fiber fragments, undesirably short fibers and particulate matter are drawn by the vacuum and resultant air flow out of the tube through its perforations to a suitable discharge.

Padilla, D.↗

Vapor-deposited platinum as a fuel-cell catalyst

Electrodes are prepared by vacuum deposition of platinum on nickel substrate with conventional vapor-deposition apparatus. Amount of platinum loaded on substrate can be veried by changing exposure time during deposition. These electrodes are significantly more effective than conventional oxygen electrodes.

Asher, W. J.↗

Electron-Photon Coincidence Calibration Of Photon Detectors

Absolute and relative detector efficiencies measured. Apparatus uses coincidence-counting techniques to measure efficiency of ultraviolet or vacuum ultraviolet detector at very low radiation intensity. Crossed electron and atomic beams generate photons used to calibrate photon detector. Pulses from electron counter and photon detector(s) processed by standard coincidence-counting techniques. Used to calibrate other detectors or make absolute measurements of incident photon fluxes.

Srivastava, Santosh K.↗

Vacuum-isolation vessel and method for measurement of thermal noise in microphones

The vacuum isolation vessel and method in accordance with the present invention are used to accurately measure thermal noise in microphones. The apparatus and method could be used in a microphone calibration facility or any facility used for testing microphones. Thermal noise is measured to determine the minimum detectable sound pressure by the microphone. Conventional isolation apparatus and methods have been unable to provide an acoustically quiet and substantially vibration free environment for accurately measuring thermal noise. In the present invention, an isolation vessel assembly comprises a vacuum sealed outer vessel, a vacuum sealed inner vessel, and an interior suspension assembly coupled between the outer and inner vessels for suspending the inner vessel within the outer vessel. A noise measurement system records thermal noise data from the isolation vessel assembly. A vacuum system creates a vacuum between an internal surface of the outer vessel and an external surface of the inner vessel. The present invention thus provides an acoustically quiet environment due to the vacuum created between the inner and outer vessels and a substantially vibration free environment due to the suspension assembly suspending the inner vessel within the outer vessel. The thermal noise in the microphone, effectively isolated according to the invention, can be accurately measured.

Zuckerwar, Allan J.↗

A Technology Demonstration Experiment for Laser Cooled Atomic Clocks in Space

We have been developing a laser-cooling apparatus for flight on the International Space Station (ISS), with the intention of demonstrating linewidths on the cesium clock transition narrower than can be realized on the ground. GLACE (the Glovebox Laser- cooled Atomic Clock Experiment) is scheduled for launch on Utilization Flight 3 (UF3) in 2002, and will be mounted in one of the ISS Glovebox platforms for an anticipated 2-3 week run. Separate flight definition projects funded at NIST and Yale by the Micro- gravity Research Division of NASA as a part of its Laser Cooling and Atomic Physics (LCAP) program will follow GLACE. Core technologies for these and other LCAP missions are being developed at JPL, with the current emphasis on developing components such as the laser and optics subsystem, and non-magnetic vacuum-compatible mechanical shutters. Significant technical challenges in developing a space qualifiable laser cooling apparatus include reducing the volume, mass, and power requirements, while increasing the ruggedness and reliability in order to both withstand typical launch conditions and achieve several months of unattended operation. This work was performed at the Jet Propulsion Laboratory under a contract with the National Aeronautics and Space Administration.

Klipstein, W. M.↗

Open-source Numerical Modeling of Solidification Cracking Susceptibility: Application to Refractory Alloy Systems

Introduction. Alloys such as aluminum, nickel-base, and austenitic stainless steels are susceptible to solidification cracking during welding and 3D printing. Compositional optimization is one method used to effectively mitigate solidification cracking of those alloy systems. With the surge in hypersonic and in-space propulsion activities, refractory metals (Nb, Mo, Ta, W, and Re) and their alloy derivatives are increasing in importance due to their extreme high melting point and retention of high-temperature strength; however, their chemistry was most typically optimized to promote ductility during mechanical operations such as drawing and forming. Welding of such alloys has been a challenge due to a number of issues including solidification cracking, atmospheric contamination (O, C, and N), as well as a shift in ductile-to-brittle transition to higher temperature following grain growth induced by welding. Compositional optimization of refractory alloys for solidification cracking resistance in particular is desirable as their usage increases with the advent of advanced manufacturing methods such as 3D printing. This work evaluates the effect of compositional variation in refractory metal systems on the solidification cracking susceptibility with the goals of optimizing existing alloys and joining process techniques, and formulating new alloys with increased solidification cracking resistance. Experimental Procedures. A python code was developed in a Jupyter notebook environment (Michael and Sowards, 2023) to facilitate the calculation of crack susceptibility index proposed by Kou (2015). Composition is entered as a single point, or as a 1-D or 2-D array. The notebook calls pycalphad (Otis and Liu, 2017 and Bocklund et al, 2020) to calculate the evolution of fraction solid as a function of temperature (under either Scheil or equilibrium assumptions) and then evaluates steepness of the fraction solid curve near the terminal stage of solidification to predict solidification cracking resistance. Open source thermodynamic databases available at online repositories are used (van de Walle). The process is setup in an automated fashion to generate plots that show variation in solidification cracking susceptibility according to composition on 1-D line plots or 2-D contour plots. The Jupyter notebook and crack susceptibility algorithm was also integrated with a widely used commercial CALPHAD code for validation and alloy exploration. Results and Discussion. The crack susceptibility model was first validated against a series of refractory alloy compositions evaluated in past work which utilized a specialized Varestraint test built inside a vacuum chamber environment (Lessman and Gold, 1971). The alloys tested in the Varestraint apparatus included T-111 (Ta-8W-2Hf), ASTAR-811C (Ta-8W-1Re-0.7Hf-0.025C), FS-85 (Nb-27Ta-10W-1Zr), T-222 (Ta-9.6W-2.4Hf-0.01C), Ta-10W, B-66 (Nb-5Mo-5V-1Zr), and SCb-291 (Nb-10W-10Ta). The initial test of the model showed a strong correlation with empirical Varestraint data, i.e., a Spearman rank correlation between model predictions and hot cracking measurements was observed to be greater than 0.8. Following the validation, a set of refractory metal binary mixtures was investigated to evaluate sensitivity of Nb, Mo, W, and Ta to C, N, and O content. A series of plots were produced that suggest ppmw ranges of C, N, and O where solidification cracking increases significantly and reaches a maximum. Also comparative ranking of each primary refractory metal to each interstitial was produced. For example C produces greater cracking response in Mo whereas O produces greater cracking response in Ta and Nb. Such compositional values have utility in setting limits on pickup of these interstitial elements during welding and printing rather than using a one-size-fits-all approach. Furthermore, the results have use in determining additive powder recycling requirements, which is especially pertinent for refractory metal powders due to their high cost compared to conventional alloys. Another application created thousands of hypothetical alloys within the nominal specified composition range of two widely used refractory alloys C103 (Nb-10Hf-1Ti) and TZM (Mo-0.5Ti-0.1Zr). The cracking index was calculated for the alloys and results were fed into machine learning regression techniques including Multiple Linear Regression, Ridge Regression, and Lasso Regression to determine relative potency each alloying element had on computed solidification cracking index. A series of linear equations were produced that relate composition of C103 and TZM to solidification cracking index. The crack susceptibility of C103 for example is described by an equation of the form: cracking index ~ O + 0.667*C + 0.635*N + 0.00037*Ta – 0.0008*Hf (in wt.%) From that equation, it is clear that O has strong propensity to induce solidification cracking. Interestingly, Hf is shown to reduce calculated cracking response. Finally, realizing the potential of this method to discover new refractory alloy formulations across the period table that have low solidification cracking sensitivity, the code was applied to new untested alloy systems including W-Zr-C, W-Ta-C, and others. Conclusions. In summary, an open source numerical method has been developed using Python code to calculate Kou’s crack susceptibility index. The method was applied to refractory metals which are inherently difficult to study from a weldability testing standpoint since inert shielding gas is not sufficient and welding is typically done in vacuum, especially in light of findings presented here where oxygen has profound influence on solidification cracking. This work revealed the effect of compositional variations on a series of refractory metals and showed the framework defined here will be useful in 1) the development of new alloys that have improved weldability and 3D printability, 2) placing compositional limits on existing alloys, and 3) ensuring adequate controls of manufacturing processes such as 3D printing where powder reuse is critical. Keywords. pycalphad; Python; refractory metals; solidification cracking. References. B. Bocklund et. al. (2020) http://doi.org/10.5281/zenodo.3630657. S. Kou. (2015) https://doi.org/10.1016/j.actamat.2015.01.034. G.G. Lessmann and R.E. Gold. Welding Journal, issue 1, pp. 1-s – 8-s (1971). F.N. Michael and J.W. Sowards. NASA/TM-20230002218 (2023). R. Otis and Z.-K. Liu. (2017) http://doi.org/10.5334/jors.140. A. Van de Wallle et. al. (2018) https://doi.org/10.1016/j.calphad.2018.04.003.

pycalphad↗

Apparatus for electrical measurements of thin films from 77 to 1000 K

A novel method of mounting thin samples for electrical measurements is described. A vacuum chuck holds a mounting plate, which, in turn, holds the sample. Contacts on the mounting plate establish electrical connection to the sample. The attachment of wires directly to the samples is unnecessary. Measurements can be made at temperatures from 77 to 1000 K. As an application of the apparatus, resistivity and Hall measurements of a thin silicon carbide sample are presented.

Matus, L. G.↗