Search NASA⌕ Search

SEARCH · Search NASA

Results for “W wall”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A filter spectrometer concept for facsimile cameras

A concept which utilizes interference filters and photodetector arrays to integrate spectrometry with the basic imagery function of a facsimile camera is described and analyzed. The analysis considers spectral resolution, instantaneous field of view, spectral range, and signal-to-noise ratio. Specific performance predictions for the Martian environment, the Viking facsimile camera design parameters, and a signal-to-noise ratio for each spectral band equal to or greater than 256 indicate the feasibility of obtaining a spectral resolution of 0.01 micrometers with an instantaneous field of view of about 0.1 deg in the 0.425 micrometers to 1.025 micrometers range using silicon photodetectors. A spectral resolution of 0.05 micrometers with an instantaneous field of view of about 0.6 deg in the 1.0 to 2.7 micrometers range using lead sulfide photodetectors is also feasible.

Jobson, D. J.↗

Approximate method for calculating transonic flow about lifting wing-body configurations: Computer program and user's manual

A user's manual is presented for a computer program which calculates inviscid flow about lifting configurations in the free-stream Mach-number range from zero to low supersonic. Angles of attack of the order of the configuration thickness-length ratio and less can be calculated. An approximate formulation was used which accounts for shock waves, leading-edge separation and wind-tunnel wall effects.

Barnwell, R. W.↗

Transonic assessment of two-dimensional wind tunnel wall interference using measured wall pressures

A method is described for assessing wall interference in two dimensional wind tunnels with better realism and accuracy than is achieved with methods based on classical wall interference theory. Measured pressure distributions were imposed as boundary conditions on a nonlinear transonic form of the potential equation to obtain an accurate computational reproduction of the actual tunnel flow. Wall-induced velocity perturbations were then extracted to yield both corrections to the tunnel test conditions and a measure of the adequacy of these corrections to account for tunnel interference. Application of the method to a transonic tunnel with variable porosity walls is illustrated.

Kemp, W. B., Jr.↗

A dry-surface coating method for visualization of separation

A relatively simple and reasonably accurate dry-surface coating method for visualization of the separation line on a bluff body was devised and successfully tested. This technique is based on the color reaction of a dry film containing a pH indicator with an appropriate gas released in the body wake. The dry-surface coating method is effective at any Reynolds number and for both incident laminar and turbulent flows. It further supplies a colorful permanent of consistently good photographic quality of the separation line. The effectiveness and accuracy of this technique were tested in visualizing the separation angle on a circular cylinder in both laminar and turbulent crossflows at subcritical Reynolds numbers. Separation angles revealed by the visualization were within + or - 4 percent of their counterparts deduced from the mean wall pressure distribution.

Sadeh, W. Z.↗

Test section configuration for aerodynamic testing in shock tubes

This paper presents results of a study of the test section configuration required to minimize or alleviate interference effects on model flow produced by the presence of test section walls in the aerodynamic testing of two dimensional transonic airfoils in a shock tube. Tests at a nominal Mach number of 0.85 and a chord Reynolds number of 2,000,000 were carried out by means of schlieren photography and pressure measurements for several symmetric airfoil profiles using shock tube test sections with unmodified straight walls, contoured walls, and slotted walls with adjacent chambers. Results were compared with corresponding results from conventional wind tunnel tests of the airfoils. Results for the straight wall tests show major airfoil flow distortions. Results from contoured wall tests and those performed using a slotted wall test section developed in this study exhibit essential agreement with wind tunnel results. The collective results show that test sections for aerodynamic testing can be designed for shock tubes that will alleviate wall interference effects.

Cook, W. J.↗

A survey of the acoustical field of a rectangular wall jet

The acoustic field of a rectangular wall jet was surveyed for Reynolds numbers between 2000 and 9200. The study includes measurements of amplitude directivity, acoustic power spectra, and flow visualization. The effects of jet speed, wall length and trailing edge angle were examined. The flow visualization survey suggests an important role of discrete vortex convection in wall tone generation.

Horne, W. C.↗

The status of two- and three-dimensional testing in the University of Southampton transonic self-streamlining wind tunnel

An automated test section was used to develop a flexible walled testing technique which eliminates some sources of uncertainty in boundary interference effects which exist in conventional transonic test sections. The flexible floor and ceiling of the test section were adjusted to contours which produce a constant Mach number distribution along each wall with no model present. These aerodynamically straight contours form the basis for all streamlining. The wall data are to contain information on the models performance and on lift. Two dimensional validation testing has continued with a cambered NPL 9510 section. Lift data up to Mach 0.87 are compared with reference data. Drag information on a NACA 0012-64 section is presented to indicate the powerful effects of streamlining. Preliminary three dimensional testing in the two dimensional test section has demonstrated that model and support blockage can be relieved by wall contouring.

Wolf, S. W. D.↗

Viscous real gas flowfields about three dimensional configurations

Laminar, real gas hypersonic flowfields over a three dimensional configuration are computed using an unsteady, factored implicit scheme. Local chemical and thermodynamic properties are evaluated by an equilibrium composition method. Transport properties are obtained from individual species properties and application of a mixture rule. Numerical solutions are presented for an ideal gas and equilibrium air for free-stream Mach numbers of 13 and 15 and at various angles of attack. The effect of real gas is to decrease the shock-layer thickness resulting from decreased shock-layer temperatures and corresponding increased density. The combined effects of viscosity and real gas are to increase the subsonic layer near the wall.

Balakrishnan, A.↗

Flux Coupling for Wheelchair Battery Chargers

Battery-charger concept for wheelchairs includes magnetic-flux coupling instead of electrical connections between power sources and wheelchairs. Concept meant to facilitate operation by patients whose disabilities make it difficult or impossible to maneuver common electrical plugs into or out of ac wall outlets.

Mclyman, C. W.↗

Measurements in an annular combustor-diffuser system

Results of three-component Laser Doppler Velocimeter (LDV) measurements in an annular combustor-diffuser system are presented in this paper. The LDV measurements were made at several locations in the prediffuser and dump regions of the combustor-diffuser test rig for three different inlet velocity profiles. The prediffuser average inlet Mach number was maintained at 0.305 during these tests. The LDV data are compared with predictions obtained from a boundary-fitted, two-dimensional elliptic analytical model. The agreement between the LDV data and the predicted results is very good for mean velocities. However, measured turbulence intensities are higher than the predicted values in the region adjacent to the prediffuser walls.

Srinivasan, R.↗