Search NASA⌕ Search

SEARCH · Search NASA

Results for “WALL TEMPERATURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

In-flight transition measurement on a 10 deg cone at Mach numbers from 0.5 to 2.0

Boundary layer transition measurements were made in flight on a 10 deg transition cone tested previously in 23 wind tunnels. The cone was mounted on the nose of an F-15 aircraft and flown at Mach numbers room 0.5 to 2.0 and altitudes from 1500 meters (5000 feet) to 15,000 meters (50,000 feet), overlapping the Mach number/Reynolds number envelope of the wind tunnel tests. Transition was detected using a traversing pitot probe in contact with the surface. Data were obtained near zero cone incidence and adiabatic wall temperature. Transition Reynolds number was found to be a function of Mach number and of the ratio of wall temperature to adiabatic all temperature. Microphones mounted flush with the cone surface measured free-stream disturbances imposed on the laminar boundary layer and identified Tollmien-Schlichting waves as the probable cause of transition. Transition Reynolds number also correlated with the disturbance levels as measured by the cone surface microphones under a laminar boundary layer as well as the free-stream impact.

Fisher, D. F.↗

Preliminary Drag and Heat-transfer Data Obtained from Air-launched Cone-cylinder Test Vehicle over Mach Number Range from 1.5 to 5.18

An air-launched cone-cylinder test vehicle designed to obtain data at Mach numbers above 4.0 was rocket boosted from a release Mach number of 5.18. The vehicle was launched at an altitude of 35,000 feet and reached peak velocity of 5150 feet per second at 28,500 feet. The total-drag coefficient (based on maximum cross-sectional area) decreased gradually from 0.31 at a Mach number of 1.75 to 0.145 at a Mach number of 5.18, while the Reynold's number (based on body length) increased from 31 x 10 to the 6th power to 107 x 10 to the 6th power. The skin friction coefficients, in general, were slightly lower than Van Driest's theoretical values for similar wall-temperature conditions. Convective heat-transfer coefficients were obtained from a single skin-thermocouple measurement. The maximum wall temperature recorded was 1240 degrees r.

Messing, Wesley E↗

Experimental Studies of the Heat Transfer to RBCC Rocket Nozzles for CFD Application to Design Methodologies

Rocket thrusters for Rocket Based Combined Cycle (RBCC) engines typically operate with hydrogen/oxygen propellants in a very compact space. Packaging considerations lead to designs with either axisymmetric or two-dimensional throat sections. Nozzles tend to be either two- or three-dimensional. Heat transfer characteristics, particularly in the throat, where the peak heat flux occurs, are not well understood. Heat transfer predictions for these small thrusters have been made with one-dimensional analysis such as the Bartz equation or scaling of test data from much larger thrusters. The current work addresses this issue with an experimental program that examines the heat transfer characteristics of a gaseous oxygen (GO2)/gaseous hydrogen (GH2) two-dimensional compact rocket thruster. The experiments involved measuring the axial wall temperature profile in the nozzle region of a water-cooled gaseous oxygen/gaseous hydrogen rocket thruster at a pressure of 3.45 MPa. The wall temperature measurements in the thruster nozzle in concert with Bartz's correlation are utilized in a one-dimensional model to obtain axial profiles of nozzle wall heat flux.

Santoro, Robert J.↗

An experimental investigation of endwall heat transfer and aerodynamics in a linear vane cascade

The purpose of this experimental investigation was to produce a data base of endwall heat transfer data under conditions that simulate those in the passage of the first-stage stator in advanced turbine engines. The data base is intended to be sufficiently complete to provide verification data for refined computational models, and to provide a basis for advanced core engine endwall cooling designs. A linear, two-dimensional cascade was used to generate the data base. The test plan provided data to examine the effects of exit Mach number, exit Reynolds number, inlet boundary layer thickness, gas-to-wall temperature ratio, inlet pressure gradients, and inlet temperature gradients. The data generated consist of inlet, intrapassage, and exit aerodynamic data plus intrapassage endwall heat flux, adiabatic wall temperature measurements, and inlet turbulence data.

York, R. E.↗

Thermal Analysis of Compressible CO2 Flow for Major Equipment of Fire Detection System

A thermal analysis of the compressible CO2 flow for the Portable Fire Extinguisher (PFE) system has been performed. The purpose of this analysis is to determine the discharged CO2 mass from the PFE tank through the Temporary Sleep Station (TeSS) nozzle in reflecting to the latest design of the extended nozzle, and to evaluate the thermal issues associated to the latest nozzle configuration. A SINDA/FLUINT model has been developed for this analysis. The model includes the PFE tank and the TeSS nozzle, and both have initial temperature of 72 of. In order to investigate the thermal effect on the nozzle due to discharging C02, the PFE TeSS nozzle pipe has been divided into three segments. This model also includes heat transfer predictions for PFE tank inner and outer wall surfaces. The simulation results show that the CO2 discharge rates have fulfilled the minimum flow requirements that the PFE system discharges 3.0 Ibm CO2 in 10 seconds and 5.5 Ibm of CO2 in 45 seconds during its operation. At 45 seconds, the PFE tank wall temperature is 63 OF, and the TeSS nozzle cover wall temperatures for the three segments are 47 OF, 53 OF and 37 OF, respectively. Thermal insulation for personal protection is used for the first two segments of the TeSS nozzle. The simulation results also indicate that at 50 seconds, the remaining CO2 in the tank may be near the triple point (gas, liquid and solid) state and, therefore, restricts the flow.

Zhang, Michael Y.↗

Thermal Analysis of Compressible CO2 Flow for PFE TeSS Nozzle of Fire Detection System

A thermal analysis of the compressible CO2 flow for the Portable Fire Extinguisher (PFE) system has been performed. A SINDA/FLUINT model has been developed for this analysis. The model includes the PFE tank and the TeSS nozzle, and both have initial temperature of 72 F. In order to investigate the thermal effect on the nozzle due to discharging CO2, the PFE TeSS nozzle pipe has been divided into three segments. This model also includes heat transfer predictions for PFE tank inner and outer wall surfaces. The simulation results show that the CO2 discharge rates have fulfilled the minimum flow requirements that the PFE system discharges 3.0 Ibm CO2 in 10 seconds and 5.5 Ibm of CO2 in 45 seconds during its operation. At 45 seconds, the PFE tank wall temperature is 63 F, and the TeSS nozzle cover wall temperatures for the three segments are 47 F, 53 F and 37 F, respectively. Thermal insulation for personal protection is used for the first two segments of the TeSS nozzle. The simulation results also indicate that at 50 seconds, the remaining CO2 in the tank may be near the triple point (gas, liquid and solid) state and, therefore, restricts the flow.

Zhang, Y. Michael↗

MLITemp: A computer program to predict the thermal effects associated with hypervelocity impact damage to space station MLI

A family of user-friendly, DOS PC based, Microsoft BASIC programs written to provide spacecraft designers with empirical predictions of space debris damage to orbiting spacecraft are described. Spacecraft wall temperatures and condensate formation is also predicted. The spacecraft wall configuration is assumed to consist of multilayered insulation (MLI) placed between a Whipple style bumper and the pressure wall. Impact damage predictions are based on data sets of experimental results obtained from simulating debris impacts on spacecraft using light gas guns on earth. A module of the program facilitates the creation of the database of experimental results that is used by the damage prediction modules to predict damage to the bumper, the MLI, and the pressure wall. A finite difference technique is used to predict temperature distributions in the pressure wall, the MLI, and the bumper. Condensate layer thickness is predicted for the case where the pressure wall temperature drops below the dew point temperature of the spacecraft atmosphere.

Rule, W. K.↗

Small rocket flowfield diagnostic chambers

Instrumented and optically-accessible rocket chambers are being developed to be used for diagnostics of small rocket (less than 440 N thrust level) flowfields. These chambers are being tested to gather local fluid dynamic and thermodynamic flowfield data over a range of test conditions. This flowfield database is being used to better understand mixing and heat transfer phenomena in small rockets, influence the numerical modeling of small rocket flowfields, and characterize small rocket components. The diagnostic chamber designs include: a chamber design for gathering wall temperature profiles to be used as boundary conditions in a finite element heat flux model; a chamber design for gathering inner wall temperature and static pressure profiles; and optically-accessible chamber designs, to be used with a suite of laser-based diagnostics for gathering local species concentration, temperature, density, and velocity profiles. These chambers were run with gaseous hydrogen/gaseous oxygen (GH2/GO2) propellants, while subsequent versions will be run on liquid oxygen/hydrocarbon (LOX/HC) propellants. The purpose, design, and initial test results of these small rocket flowfield diagnostic chambers are summarized.

Morren, Sybil↗

Correlation and analysis of elevon seal test results

The heating rate and pressure distributions in and around the elevon coves were correlated. An analytical approach incorporating such a correlation into a thermal structure computer code to examine the elevon seal and cover structure in flight was developed. Emphasis was placed on the design of a thermal model that predicts gas and wall temperatures in the cove area. The elevon cove area was modelled analytically by a parallel plate flow channel, incorporating effects of axial wall conduction, axial and environmental radiant energy exchanges, and effects of laminar and turbulent convection entrance regions. Comparisons were made between computed and measured values of (1) cove wall temperatures; (2) local gas temperature within the cove; and (3) local heating rates.

Keshock, E. G.↗

Effect of Reynolds number variation on aerodynamics of a hydrogen-fueled transport concept at Mach 6

Two separate tests have been made on the same blended wing-body hydrogen-fueled transport model at a Mach number of about 6 and a range of Reynolds number (based on theoretical body length) of 1.577 to 55.36 X 10 to the 6th power. The results of these tests, made in a conventional hypersonic blowdown tunnel and a hypersonic shock tunnel, are presented through a range of angle of attack from -1 to 8 deg, with an extended study at a constant angle of attack of 3 deg. The model boundary layer flow appeared to be predominately turbulent except for the low Reynolds number shock tunnel tests. Model wall temperatures varied considerably; the blowdown tunnel varied from about 255 F to 340 F, whereas the shock tunnel had a constant 70 F model wall temperature. The experimental normal-force coefficients were essentially independent of Reynolds number. A current theoretical computer program was used to study the effect of Reynolds number. Theoretical predictions of normal-force coefficients were good, particularly at anticipated cruise angles of attack, that is 2 to 5 deg. Axial-force coefficients were generally underestimated for the turbulent skin friction conditions, and pitching-moment coefficients could not be predicted reliably.

Penland, Jim A.↗

Experimentation and Modeling of Jet A Thermal Stability in a Heated Tube

High performance aircraft typically use hydrocarbon fuel to regeneratively cool the airframe and engine components. As the coolant temperatures increase, the fuel may react with dissolved oxygen forming deposits that limit the regenerative cooling system performance. This study investigates the deposition of Jet A using a thermal stability experiment and computational fluid dynamics (CFD) modeling. The experimental portion of this study is performed with a high Reynolds number thermal stability (HiRets) tester in which fuel passes though an electrically heated tube and the fuel outlet temperature is held constant. If the thermal stability temperature of the fuel is exceeded, deposits form and adhere to the inside of the tube creating an insulating layer between the tube and the fuel. The HiRets tester measures the tube outer wall temperatures near the fuel outlet to report the effect of deposition occurring inside the tube. Final deposits are also estimated with a carbon burn off analysis. The CFD model was developed and used to simulate the fluid dynamics, heat transfer, chemistry, and transport of the deposit precursors. The model is calibrated to the experiment temperature results and carbon burn-off deposition results. The model results show that the dominant factor in deposition is the heated wall temperature and that most of the deposits are formed in the laminar sublayer. The models predicted a 7.0E-6 kilograms per square meter-sec deposition rate, which compared well to the carbon burn-off analysis deposition rate of 1.0E-6 kilograms per square meter-sec.

Khodabandeh, Julia W.↗

Correlation of Forced-convection Heat-transfer Data for Air Flowing in Smooth Platinum Tube with Long-approach Entrance at High Surface and Inlet-air Temperatures

A heat-transfer investigation was conducted with air in an electrically heated platinum tube with long-approach entrance, inside diameter of 0.525 inch, and effective heat-transfer length of 24 inches over ranges of Reynolds number up to 320,000, average inside-tube-wall temperature up to 3053 degrees R, and inlet-air temperature up to 1165 degrees R. Correlation of data by the conventional Nusselt relation resulted in separation of data with tube-wall temperature. Good correlation was obtained, however, by use of a modified Reynolds number.

Desmon, Leland G↗

Thermodynamic modeling of the no-vent fill methodology for transferring cryogens in low gravity

The filling of tanks with cryogens in the low-gravity environment of space poses many technical challenges. Chief among these is the inability to vent only vapor from the tank as the filling proceeds. As a potential solution to this problem, the NASA Lewis Research Center is researching a technique known as No-Vent Fill. This technology potentially has broad application. The focus is the fueling of space based Orbital Transfer Vehicles. The fundamental thermodynamics of the No-Vent Fill process to develop an analytical model of No-Vent Fill is described. The model is then used to conduct a parametric investigation of the key parameters: initial tank wall temperature, liquid-vapor interface heat transfer rate, liquid inflow rate, and inflowing liquid temperatures. Liquid inflowing temperature and the liquid-vapor interface heat transfer rate seem to be the most significant since they influence the entire fill process. The initial tank wall temperature must be sufficiently low to prevent a rapid pressure rise during the initial liquid flashing stage, but then becomes less significant.

Chato, David J.↗

Thermodynamic modeling of the no-vent fill methodology for transferring cryogens in low gravity

The filling of tanks with cryogens in the low-gravity environment of space poses many technical challenges. Chief among these is the inability to vent only vapor from the tank as the filling proceeds. As a potential solution to this problem, the NASA Lewis Research Center is researching a technique known as No-Vent Fill. This technology potentially has broad application. The focus is the fueling of space based Orbital Transfer Vehicles. The fundamental thermodynamics of the No-Vent Fill is described. The model is then used to conduct a parametric investigation of the key parameters: initial tank wall temperature, liquid-vapor interface heat transfer rate, liquid inflow rate, and inflowing liquid temperatures. Liquid inflowing temperature and the liquid-vapor interface heat transfer rate seem to be the most significant since they influence the entire fill process. The initial tank wall temperature must be sufficiently low to prevent a rapid pressure rise during the initial liquid flashing state, but then becomes less significant.

Chato, David J.↗

Heat Transfer from High-Temperature Surfaces to Fluids III - Correlation of Heat-Transfer Data for Air Flowing in Silicon Carbide Tube with Rounded Entrance, Inside Diameter of 3/4 Inch, and Effective Length of 12 Inches

A heat-transfer investigation was conducted with air flowing through an electrically heated silicon carbide tube with a rounded entrance, an inside diameter of 3/4 inch, and effective heat-transfer length of 12 inches over a range of Reynolds numbers up to 300,000 and a range of average inside-tube-wall temperatures up to 2500 R. The highest corresponding local outside-tube-wall temperature was 3010 R.

Sams, Eldon W.↗

An experimental investigation of high-aspect-ratio cooling passages

An experimental investigation was conducted to evaluate the effectiveness of using high-aspect-ratio cooling passenges to improve the life and reduce the colant pressure drop in high-pressure rocket thrust chambers. A plug-nozzle rocket-engine test apparatus was used to test two cylindrical chambers with low-aspect-ratio cooling passages and one with high-aspect-ratio cooling passages. The chambers were cyclically tested and data were taken over a wide range of coolant mass flows. The results showed that for the same coolant pressure drop, the hot-gas-side wall temperature of the high-aspect-ratio chamber was 30 percent lower than the baseline low-aspect-ratio chamber, resulting in no fatigue damage to the wall. The coolant pressure drop for the high-aspect-ratio chamber was reduced in increments to one-half that of the baseline chamber, by reducing the coolant mass flow, and still resulted in a reduction in the hot-gas-side wall temperature when compared to the low-aspect-ratio chambers.

Carlile, Julie A.↗

An experimental investigation of high-aspect-ratio cooling passages

An experimental investigation was conducted to evaluate the effectiveness of using high-aspect-ratio cooling passages to improve the life and reduce the coolant pressure drop in high-pressure rocket thrust chambers. A plug-nozzle rocket-engine test apparatus was used to test two cylindrical chambers with low-aspect-ratio cooling passages and one with high-aspect-ratio cooling passages. The chambers were cyclically tested and data were taken over a wide range of coolant mass flows. The results showed that for the same coolant pressure drop, the hot-gas-side wall temperature of the high-aspect-ratio chamber was 30 percent lower than the baseline low-aspect-ratio chamber, resulting in no fatigue damage to the wall. The coolant pressure drop for the high-aspect-ratio chamber was reduced in increments to one-half that of the baseline chamber, by reducing the coolant mass flow, and still resulted in a reduction in the hot-gas-side wall temperature when compared to the low-aspect-ratio chambers.

Carlile, Julie A.↗

Analysis of film cooling in rocket nozzles

Progress during the reporting period is summarized. Analysis of film cooling in rocket nozzles by computational fluid dynamics (CFD) computer codes is desirable for two reasons. First, it allows prediction of resulting flow fields within the rocket nozzle, in particular the interaction of the coolant boundary layer with the main flow. This facilitates evaluation of potential cooling configurations with regard to total thrust, etc., before construction and testing of any prototype. Secondly, CFD simulation of film cooling allows for assessment of the effectiveness of the proposed cooling in limiting nozzle wall temperature rises. This latter objective is the focus of the current work. The desired objective is to use the Finite Difference Navier Stokes (FDNS) code to predict wall heat fluxes or wall temperatures in rocket nozzles. As prior work has revealed that the FDNS code is deficient in the thermal modeling of boundary conditions, the first step is to correct these deficiencies in the FDNS code. Next, these changes must be tested against available data. Finally, the code will be used to model film cooling of a particular rocket nozzle. The third task of this research, using the modified code to compute the flow of hot gases through a nozzle, is described.

Woodbury, Keith A.↗