Search NASA⌕ Search

SEARCH · Search NASA

Results for “WATER CONTENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Regional Mapping of Forest Canopy Water Content and Biomass Using AIRSAR Images over BOREAS Study Area

In recent years, monitoring vegetation biomass over various climate zones has become the primary focus of several studies interested in assessing the role of the ecosystem responses to climate change and human activities. Airborne and spaceborne synthetic-aperture radar (SAR) systems provide a useful tool to directly estimate biomass due to its sensitivity structure and moisture characteristics.

Forestry↗

Satellite observations of a polar low over the Norwegian Sea by Special Sensor Microwave Imager, Geosat, and TIROS-N Operational Vertical Sounder

Many polar lows are generated at the boundary between sea ice and the ocean, in regions of large temperature gradients, where in situ observations are rare or nonexistent. Since satellite observations are frequent in high-latitude regions, they can be used to detect polar lows and track their propagation and evolution. The Special Sensor Microwave/Imager (SSM/I) providing estimates of surface wind speed, integrated cloud liquid water content, water vapor content, and precipitation size ice-scattering signal over the ocean; the Geosat radar altimeter measuring surface wind speed and significant wave height; and the TIROS-N Operational Vertical Sounder (TOVS) allowing the determination of temperature and humidity profiles in the atmosphere have been used in synergy for a specific case which occurred in the Norwegian Sea on January, 23-24 1988. All three instruments show sharp atmospheric gradients associated with the propagation of this low across the ocean, which permit the detection of the polar low at a very early stage and tracking it during its development, propagation, and decay. The wind speed gradients are measured with good qualitative agreement between the altimeter and SSM/I. TOVS retrieved fields prior to the formation of the low confirm the presence of an upper level trough, while during the mature phase baroclinicity can be observed in the 1000-500 hPa geopotential thicknesses.

Claud, Chantal↗

Estimating soil water evaporation using radar measurements

Field studies were conducted to evaluate the application of radar reflectivity as compared with the shortwave reflectivity (albedo) used in the Idso-Jackson equation for the estimation of daily evaporation under overcast sky and subhumid climatic conditions. Soil water content, water potential, shortwave and radar reflectivity, and soil and air temperatures were monitored during three soil drying cycles. The data from each cycle were used to calculate daily evaporation from the Idso-Jackson equation and from two other standard methods, the modified Penman and plane of zero-flux. All three methods resulted in similar estimates of evaporation under clear sky conditions; however, under overcast sky conditions, evaporation fluxes computed from the Idso-Jackson equation were consistently lower than the other two methods. The shortwave albedo values in the Idso-Jackson equation were then replaced with radar reflectivities and a new set of total daily evaporation fluxes were calculated. This resulted in a significant improvement in computed soil evaporation fluxes from the Idso-Jackson equation, and a better agreement between the three methods under overcast sky conditions.

Sadeghi, Ali M.↗

Survey of microphysical properties of marine boundary-layer clouds in the Western North Atlantic

Oceanic low level clouds strongly affect the atmospheric radiation budget. Uncertainties in their microphysical properties and cover currently limit the accuracy of climate predictions. Further, studies quantifying the relative importance of aerosol and dynamics on cloud properties in specific meteorological regimes are poorly constrained by observations in the Western North Atlantic boundary layer. Low level clouds were measured during the Aerosol Cloud meTereology Interactions oVer the western ATlantic Experiment (ACTIVATE) campaign in winter and summer 2020. The two NASA LaRC research aircraft HU-25 Falcon and UC-12 B-200 King Air conducted 35 simultaneous flights to investigate aerosol-cloud interactions of maritime clouds and their impact on radiation. Number concentration, liquid water content, ice water content, and particle size distribution in the size range of 3 µm to 1460 µm in diameter were measured with the fast forward scattering cloud probe (FCDP) and 2-dimensional optical array imaging probe (2D-S) onboard the Falcon. Here, we present an overview of late winter (February-March) and late summer (August-September) oceanic cloud properties in the region 65°W to 80°W and 30°N to 40°N. We compare cloud properties in these two seasons and investigate their dependence on meteorological parameters and aerosol abundance. In a case study, we present cloud observations in a cold air outbreak event on 1 March 2020 with a specific focus on mixed-phase clouds.

microphysical properties↗

Behavior of an inversion-based precipitation retrieval algorithm with high-resolution AMPR measurements including a low-frequency 10.7-GHz channel

A microwave-based, profile-type precipitation retrieval algorithm has been used to analyze high-resolution passsive microwave measurements over an ocean background, obtained by the Advanced Microwave Precipitation Radiometer (AMPR) flown on a NASA ER-2 aircraft. The analysis is designed to first determine the improvements that can be gained by adding brightness temperature information from the AMPR low-frequency channel (10.7 GHz) to a multispectral retrieval algorithm nominally run with satellite information at 19, 37, and 85 GHz. The impact of spatial resolution degradation of the high-resolution brightness temperature information on the retrieved rain/cloud liquid water contents and ice water contents is then quantified in order to assess the possible biases inherent to satellite-based retrieval. Careful inspection of the high-resolution aircraft dataset reveals five distinctive brightness temperature features associated with cloud structure and scattering effects that are not generally detectable in current passive microwave satellite measurements. Results suggest that the inclusion of 10.7-GHz information overcomes two basic problems associated with three-channel retrieval. Intercomparisons of retrievals carried out at high-resolution and then averaged to a characteristic satellite scale to the corresponding retrievals in which the brightness temperatures are first convolved down to the satellite scale suggest that with the addition of the 10.7-GHz channel, the rain liquid water contents will not be negatively impacted by special resolution degradation. That is not the case with the ice water contents as they appear ti be quite sensitive to the imposed scale, the implication being that as spatial resolution is reduced, ice water contents will become increasingly underestimated.

Smith, E. A.↗

Storage stability and improvement of intermediate moisture foods

The rates of chemical reactions which deteriorate foods prepared to an intermediate moisture content and water activity (A sub w 0.6 to 0.9) were studied. The phenomenon of sorption hysteresis was used to prepare model systems and foods to similar A sub w's but different moisture levels so that the separate effects of water binding and water content could be elucidated. It was found that water content is the controlling factor for lipid oxidation in model systems comprised of a solid support and an oxidizable liquid. It was proposed that metal chelating agents like EDTA should give good protection to oxidation. EDTA exhibited the highest efficacy, about 10-15 times better than BHA which is a radical scavenger when studied in the model systems.

Labuza, T. P.↗

Test Results for the SEA Ice Crystal Detector (ICD) under SLD Conditions at the NASA IRT

The Science Engineering Associates hot-wire Ice Crystal Detector was tested under Appendix C and Supercooled Large Drop Conditions at the NASA Icing Research Tunnel, with the purpose of comparing the measurements to the tunnel LWC calibration, and to test the performance of the mixed-phase retrievals of the probe. The liquid water content measured by the total water content sensor of the probe agreed well with the tunnel calibration over a wide range of MVDs, not unexpectedly since the tunnel was calibrated with a similar Multiwire hot-wire probe. A scale factor difference of about 7% was attributed to the lack of an efficiency correction for the Ice Crystal Detector at smaller median volume diameters, and typical sample area uncertainties of liquid water content devices. In addition, the simultaneous equations that are used to retrieve liquid and ice water contents were tested under liquid and glaciated conditions. Using constant ice and water efficiencies for each wire, the equations were found to produce a large and false ice water content retrieval in large median volume diameter liquid cases. By applying a liquid efficiency to the liquid water content sensor that varied with median volume diameter, retrievals were improved such that false ice water content was less than ±10% of the total water content out to the 460 μm median volume diameter limit of the testing. The probe was also tested in glaciated conditions by freezing out a small median volume diameter spray. Using constant ice efficiencies for the two sensors provided from aircraft measurements, the retrieved ice water content was about 40% higher than expected for the case presented, likely due to the ice efficiencies that were used from aircraft measurements of natural clouds being too low for the tunnel’s glaciated sprays. Application of ice efficiencies that vary with particle size and potentially other parameters will be explored for future improvement of retrievals.

Air Craft Icing↗

Test Results for the SEA Ice Crystal Detector (ICD) under SLD Conditions at the NASA IRT

The Science Engineering Associates hot-wire Ice Crystal Detector was tested under Appendix C and Supercooled Large Drop Conditions at the NASA Icing Research Tunnel, with the purpose of comparing the measurements to the tunnel LWC calibration, and to test the performance of the mixed-phase retrievals of the probe. The liquid water content measured by the total water content sensor of the probe agreed well with the tunnel calibration over a wide range of MVDs, not unexpectedly since the tunnel was calibrated with a similar Multiwire hot-wire probe. A scale factor difference of about 7% was attributed to the lack of an efficiency correction for the Ice Crystal Detector at smaller median volume diameters, and typical sample area uncertainties of liquid water content devices. In addition, the simultaneous equations that are used to retrieve liquid and ice water contents were tested under liquid and glaciated conditions. Using constant ice and water efficiencies for each wire, the equations were found to produce a large and false ice water content retrieval in large median volume diameter liquid cases. By applying a liquid efficiency to the liquid water content sensor that varied with median volume diameter, retrievals were improved such that false ice water content was less than ±10% of the total water content out to the 460 μm median volume diameter limit of the testing. The probe was also tested in glaciated conditions by freezing out a small median volume diameter spray. Using constant ice efficiencies for the two sensors provided from aircraft measurements, the retrieved ice water content was about 40% higher than expected for the case presented, likely due to the ice efficiencies that were used from aircraft measurements of natural clouds being too low for the tunnel’s glaciated sprays. Application of ice efficiencies that vary with particle size and potentially other parameters will be explored for future improvement of retrievals.

o Aircraft Icing↗

Diurnal water relations of walnut trees - Implications for remote sensing

Leaflet water content (WC), relative water content (RWC), and water potential, Phi(lf) were measured as indicators of diurnal change in tree water status in an experimental walnut orchard receiving two irrigation treatments: 100 and 33 percent of potential evapotranspiration (PET). Diurnal change was greatest in Phi(lf) throughout the experimental period, with minima occurring each day in early to mid-afternoon and maxima between midnight and sunrise. Leaflet WC and RWC were lower in the afternoon than at night, but had greater variability so that the diurnal pattern was not as clear. Comparison between the pattern of Phi(lf) and dielectric constants (DCs) measured from probes inserted 2 cm into a tree hole showed that both declined nearly in parallel in the morning. Phi(lf) recovered more rapidly than DC in the afternoon. This temporal discrepancy could be caused by cavitation of xylem elements in the vicinity of the DC probe. Microwave backscatter for L- and X-bands also measured diurnal variation that had local minima in the afternoon, but the pattern among wavelength and polarization signatures was complex.

Weber, James A.↗

Instrument for Aircraft-Icing and Cloud-Physics Measurements

The figure shows a compact, rugged, simple sensor head that is part of an instrumentation system for making measurements to characterize the severity of aircraft-icing conditions and/or to perform research on cloud physics. The quantities that are calculated from measurement data acquired by this system and that are used to quantify the severity of icing conditions include sizes of cloud water drops, cloud liquid water content (LWC), cloud ice water content (IWC), and cloud total water content (TWC). The sensor head is mounted on the outside of an aircraft, positioned and oriented to intercept the ambient airflow. The sensor head consists of an open housing that is heated in a controlled manner to keep it free of ice and that contains four hot-wire elements. The hot-wire sensing elements have different shapes and sizes and, therefore, exhibit different measurement efficiencies with respect to droplet size and water phase (liquid, frozen, or mixed). Three of the hot-wire sensing elements are oriented across the airflow so as to intercept incoming cloud water. For each of these elements, the LWC or TWC affects the power required to maintain a constant temperature in the presence of cloud water.

Lilie, Lyle↗