Search NASA⌕ Search

SEARCH · Search NASA

Results for “Web based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Web-based, GPU-accelerated, Monte Carlo simulation and visualization of indirect radiation imaging detector performance

Purpose: Monte Carlo simulations play a vital role in the understanding of the fundamental limitations, design, and optimization of existing and emerging medical imaging systems. Efforts in this area have resulted in the development of a wide variety of open-source software packages. One such package, hybridMANTIS, uses a novel hybrid concept to model indirect scintillator detectors by balancing the computational load using dual CPU and graphics processing unit (GPU) processors, obtaining computational efficiency with reasonable accuracy. In this work, the authors describe two open-source visualization interfaces, webMANTIS and visualMANTIS to facilitate the setup of computational experiments via hybridMANTIS. Methods: The visualization tools visualMANTIS and webMANTIS enable the user to control simulation properties through a user interface. In the case of webMANTIS, control via a web browser allows access through mobile devices such as smartphones or tablets. webMANTIS acts as a server back-end and communicates with an NVIDIA GPU computing cluster that can support multiuser environments where users can execute different experiments in parallel. Results: The output consists of point response and pulse-height spectrum, and optical transport statistics generated by hybridMANTIS. The users can download the output images and statistics through a zip file for future reference. In addition, webMANTIS provides a visualization window that displays a few selected optical photon path as they get transported through the detector columns and allows the user to trace the history of the optical photons. Conclusions: The visualization tools visualMANTIS and webMANTIS provide features such as on the fly generation of pulse-height spectra and response functions for microcolumnar x-ray imagers while allowing users to save simulation parameters and results from prior experiments. The graphical interfaces simplify the simulation setup and allow the user to go directly from specifying input parameters to receiving visual feedback for the model predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-E-07: Web-Based Training for Radiosurgery: Methods and Metrics for Global Reach

Purpose: Webinars have become an evolving tool with greater or lesser success in reaching health care providers (HCPs). This study seeks to assess best practices and metrics for success in webinar deployment for optimal global reach. Methods: Webinars have been developed and launched to reach practicing health care providers in the field of radiation oncology and radiosurgery. One such webinar was launched in early February 2016. “Multiple Brain Metastases & Volumetric Modulated Arc Radiosurgery: Refining the Single-Isocenter Technique to Benefit Surgeons and Patients” presented by Drs. Fiveash and Thomas from UAB was submitted to and accredited by the Institute for Medical Education as qualifying for CME as well as MDCB for educational credit for dosimetrists, in order to encourage participation. MedicalPhysicsWeb was chosen as the platform to inform attendees regarding the webinar. Further IME accredited the activity for 1 AMA PRA Category 1 credit for physicians & medical physicists. The program was qualified by the ABR in meeting the criteria for self-assessment towards fulfilling MOC requirements. Free SAMs credits were underwritten by an educational grant from Varian Medical Systems. Results: The webinar in question attracted 992 pre-registrants from 66 countries. Outside the US and Canada; 11 were from the Americas; 32 were from Europe; 9 from the Middle East and Africa. Australasia and the Indian subcontinent represented the remaining 14 countries. Pre-registrants included 423 Medical Physicists, 225 Medical Dosimetrists, 24 Radiation Therapists, 66 Radiation Oncologists & other. Conclusion: The effectiveness of CME and SAM-CME programs such as this can be gauged by the high rate of respondents who state an intention to change practice habits, a primary goal of continuing medical education and self-assessment. This webinar succeeded in being the most successful webinar on Medical Physics Web as measured by pre-registration, participation and participation to pre-registration ratio. R.A. Schulz is an employee of Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Web-based wide-area monitoring platform for ringdown and clustering analytics in power systems

This paper introduces an open-source research platform for monitoring the Mexican interconnected power grid, allowing real-time processing and information extraction of the grid’s dynamic condition. Moreover, the platform is a Python-based development that embeds different ringdown and clustering analytics tools. In the case of ringdown analysis, the modal information can be extracted using some of the most known algorithms, i.e., Prony analysis, eigensystem realization algorithm (ERA), and matrix pencil (MP). For clustering analysis, the coherent behaviour of generator and non-generator buses is provided by applying recent state-of-the-art techniques such as affinity propagation, K-means, hierarchical agglomerative clustering, and typicality data analysis. The results of up to 93 PMUs show that this open-source platform suits researchers’ and engineers’ power system dynamic analysis requirements.

Clustering↗

Validation of the Web-Based IBTR! 2.0 Nomogram to Predict for Ipsilateral Breast Tumor Recurrence After Breast-Conserving Therapy

Purpose: To evaluate the IBTR! 2.0 nomogram, which predicts 10-year ipsilateral breast tumor recurrence (IBTR) after breast-conserving therapy with and without radiation therapy for breast cancer, by using a large, external, and independent cancer center database. Methods and Materials: We retrospectively identified 1898 breast cancer cases, treated with breast-conserving therapy and radiation therapy at the University Hospital Leuven from 2000 to 2007, with requisite data for the nomogram variables. Clinicopathologic factors were assessed. Two definitions of IBTR were considered where simultaneous regional or distant recurrence were either censored (conform IBTR! 2.0) or included as event. Validity of the prediction algorithm was tested in terms of discrimination and calibration. Discrimination was assessed by the concordance probability estimate and Harrell's concordance index. The mean predicted and observed 10-year estimates were compared for the entire cohort and for 4 risk groups predefined by nomogram-predicted IBTR risks, and a calibration plot was drawn. Results: Median follow-up was 10.9 years. The 10-year IBTR rates were 1.3% and 2.1%, according to the 2 definitions of IBTR. The validation cohort differed from the development cohort with respect to the administration of hormonal therapy, surgical section margins, lymphovascular invasion, and tumor size. In univariable analysis, younger age (P=.002) and a positive nodal status (P=.048) were significantly associated with IBTR, with a trend for the omission of hormonal therapy (P=.061). The concordance probability estimate and concordance index varied between 0.57 and 0.67 for the 2 definitions of IBTR. In all 4 risk groups the model overestimated the IBTR risk. In particular, between the lowest-risk groups a limited differentiation was suggested by the calibration plot. Conclusions: The IBTR! 2.0 predictive model for IBTR in breast cancer patients shows substandard discriminative ability, with an overestimation of the risk in all subgroups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FQC Dashboard: integrates FastQC results into a web-based, interactive, and extensible FASTQ quality control tool

Abstract Summary FQC is software that facilitates quality control of FASTQ files by carrying out a QC protocol using FastQC, parsing results, and aggregating quality metrics into an interactive dashboard designed to richly summarize individual sequencing runs. The dashboard groups samples in dropdowns for navigation among the data sets, utilizes human-readable configuration files to manipulate the pages and tabs, and is extensible with CSV data. Availability and implementation FQC is implemented in Python 3 and Javascript, and is maintained under an MIT license. Documentation and source code is available at: https://github.com/pnnl/fqc.

59 BASIC BIOLOGICAL SCIENCES↗

Estimating the Impacts of Direct Load Control Programs Using GridPIQ, a Web-Based Screening Tool

In direct load control (DLC) programs, utilities can curtail the demand of participating loads to contractually agreed-upon levels during periods of critical peak load, thereby reducing stress on the system, generation cost, and required transmission and generation capacity. Participating customers receive financial incentives. The impacts of implementing DLC programs extend well beyond peak shaving. There may be a shift of load proportional to the interrupted load to the times before or after a DLC event, and different load shifts have different consequences. Tools that can quantify the impacts of such programs on load curves, peak demand, emissions, and fossil fuel costs are currently lacking. The Grid Project Impact Quantification (GridPIQ) screening tool includes a Direct Load Control module, which takes into account project-specific inputs as well as the larger system context in order to quantify the impacts of a given DLC program. This allows users (utilities, researchers, etc.) to test and compare different program specifications and their impacts.

Demand Reponse↗