Search NASA⌕ Search

SEARCH · Search NASA

Results for “Windowing System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Dynamic Control of Sodium Cold Trap Purification Temperature Using LSTM System Identification

This study investigates the dynamic regulation of the sodium cold trap purification temperature at Argonne National Laboratory’s liquid sodium test facility, employing long short-term memory (LSTM) system identification techniques. The investigation introduces an innovative hybrid approach by integrating model predictive control (MPC) based on first principles dynamic models with a multi-step time–frequency LSTM model in predicting the temperature profiles of a sodium cold trap purification system. The long short-term memory–model predictive controller (LSTM-MPC) model employs a sliding window scheme to gather training samples for multi-step prediction, leveraging historical data to construct predictive models that capture the non-linearities of the complex system dynamics without explicitly modeling the underlying physical processes. The performance of the LSTM-MPC and MPC were evaluated through simulation experiments, where both models were assessed on their capacity to maintain the cold trap temperature within predefined set-points while minimizing deviations and overshoots. Results obtained show how the data-driven LSTM-MPC model demonstrates stability and adaptability. In contrast, the traditional MPC model exhibits irregularities, particularly evident as overshoots around set-point limits, which can potentially compromise its effectiveness over long prediction time intervals. The findings obtained offer valuable insights into integrating data-driven techniques for enhancing real-time monitoring systems.

LSTM-MPC↗

Precursor Analysis Report: Industroyer Targeting Ukraine Electric Power Transport Utility (Ukrenergo) 2016

The Industroyer Targeting Ukraine Electric Power Transport Utility (Ukrenergo) 2016 Precursor Analysis Report leverages publicly available information about the December 2016 cyber attack against the Ukrainian Ukrenergo electric transmission utility and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. Industroyer is a modular malware framework designed to deploy several Industrial Control System (ICS) protocol-specific attack payloads to disrupt electricity distribution. Adversaries deployed Industroyer within the target network on a Microsoft Windows endpoint capable of directly manipulating or communicating with ICS. Industroyer abuses the functionality of a targeted ICS’s legitimate control system to achieve its intended impact. Adversaries likely first gained access to Ukrenergo enterprise networks in early 2016 after a successful spearphishing campaign against organizations in the electric power sector. Adversaries then began capturing credentials beginning on 1 December 2016. This allowed access to the ICS environment at the Pivnichna electric transmission substation outside Kyiv through a device dual-homed on the Information Technology (IT) and ICS networks. Adversaries conducted discovery, targeting, and access to this device using information and previously captured credentials from compromised enterprise IT machines. Finally, the adversaries deployed and launched the Industroyer malware just before midnight on 17 December. By midnight, Ukrenergo had lost control of a targeted substation, resulting in electric power outages for over an hour in the city of Kyiv and the Kyiv region. Researchers and analysts identified 31 unique techniques (used in a sequence of 33 steps) utilized during the attack with a total of 846 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Twenty-nine of the identified techniques used during the Industroyer cyber attack were precursors to the triggering event. Analysis identified 548 observables associated with these precursor techniques, 353 of which were assessed to have an increased likelihood of being perceived in the 300 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Numerical Analysis and Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 discs. The irradiation process generates large amounts of heat and is cooled using pressurized helium gas flowing at 400 g/s. LANL provides both numerical analysis support and experimental support. Computational fluid dynamics (CFD) simulations for both 300 g/s and 400 g/s are performed on the NMR target to analyze the helium flow through the NMR system. The pressure drop, the mass flow rate through each of the disc and window channels and the force applied on the first disc are some of the quantities estimated using CFD. These results will be combined with Monte Carlo N-Particle (MCNP) estimates of heat flux into the system from the electron beam to perform conjugate heat transfer analysis (CHT). The experiments presented in this report focus on the effect of the flow induced vibrations from helium flowing through the coolant gaps between the discs. There is concern that the flow induced vibrations may lead to excessive mass loss of the enriched Mo-100 discs, and the goal would be to mitigate the mass loss. This work presents benchtop tests of flow through a subset of the target stack which involves high speed imaging and displacement measurements used to estimate disc vibration, as well as mass loss.

42 ENGINEERING↗

Insights into the phase stability window, phase transformation behavior, and anisotropic thermal expansion of rhombohedral bismuth oxide

Rhombohedral bismuth oxide has emerged as a promising SOFC electrolyte material, particularly at low-to-intermediate temperatures. The stability window of this phase was explored using a co-doped system, using yttrium and lanthanum or aluminum, over 7.5–25 % total dopant content and 0.907–1.154 Å weighted average dopant cationic radius. The phase transformation behavior of rhombohedral-rich phase mixtures was also investigated in situ from 360 to 656 °C to assess the effects of minor impurity phases and thermal evolution pathways. Our results reveal that low-dopant, rhombohedral-rich compositions exhibit poor structural stability upon heating. Anisotropic thermal expansion behavior was observed over 450–656 °C, serving as a sensitive indicator of sequential phase changes, including the rhombohedral β2-to-β1 transition (∼450 °C), monoclinic phase formation, and delayed or incomplete formation of the cubic phase (∼ 550 °C). These multiple unfavorable phase transitions compromise the mechanical robustness required for SOFC operation. This study underscores the need for compositional tuning to balance ionic conductivity with thermal phase stability in rhombohedral Bi 2 O 3 -based systems.

36 MATERIALS SCIENCE↗

Compact mid-infrared dual-comb spectrometer for outdoor spectroscopy

This manuscript describes the design of a robust, mid-infrared dual-comb spectrometer operating in the 3.1-µm to 4-µm spectral window for future field applications. The design represents an improvement in system size, power consumption, and robustness relative to previous work while also providing a high spectral signal-to-noise ratio. We demonstrate a system quality factor of 2×10 6 and 30 hours of continuous operation over a 120-meter outdoor air path.

Ycas, Gabriel↗

Converting from NIS to Redhat Identity Management

The Jefferson Lab (Jlab) accelerator controls network has transitioned to a new authentication and network service interface. The new system uses the Redhat Identity Manager (IdM) as a single integrating front end to the Lightweight Directory Access Protocol (LDAP) and a replacement for NIS and the Kerberos authentication service. This system allows for integration of access and authentication across Unix and Windows environments and across different Jlab computing environments, including across firewalls. The decision making process, conversion steps, issues and solutions will be discussed.

McGuckin, T. S.↗

PDV Sensitivity [Slides]

The concept of PDV sensitive is not new. But we tend not to discuss sensitivity in a rigorous, quantified way. That should change. Indeed there is a natural definition, which is just the energy of light from the target within the analysis window that gives a SNR of 10 in the frequency domain. Systems designers, diagnostic engineers, and operators should use the language of sensitivity: (1) Absolute sensitivity: nW * ns; (2) Launch power: mW or dBm; (3) Relative surface return: dB; (4) Relative sensitivity: dB * ns. This will help us design better systems, choose the correct system for the job, maintain our systems, and tune our systems.

47 OTHER INSTRUMENTATION↗

COG User's Manual: A Multiparticle Monte Carlo Transport Code (Sixth Edition)

COG is a high-resolution code for the Monte Carlo simulation of coupled particle transport in arbitrary 3-D geometry. COG will transport neutrons, protons, deuterons, alpha particles with energies up to hundreds of GeV, and photons with energy ranges limited by the available cross section sets and physics models. Electrons can be transported via the EGS5 electron transport kernel, electrons can also be transported. The COG code is a significant upgrade from earlier Monte Carlo transport codes and has been written specifically to make it more versatile, accurate, and easy to use. COG has provisions for calculating deep penetration (shielding) problems, criticality problems, and neutron activation problems while retains all of the standard capabilities found in other Monte Carlo transport codes. COG uses high-resolution pointwise cross-section databases and makes no compromises in the transport physics, so that the results of a COG run are limited only by the accuracy of the databases used. COG runs primarily on Linux Operating System workstations with MPICH software installed – currently, Red Hat 7 & 8, Windows 10 (Windows Subsystem for Linux –WSL), Ubuntu 16, 18 & 20, OpenSUSE Leap 15.2, Fedora 32, Apple Power Mac with Intel CPU (with MacPorts installed) workstations, and LLNL LC supercomputer CTS-1 cluster with TOSS 3 are supported.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intra-hour Solar Irradiance Forecast in Multiple Locations using Deep Transfer Learning

In recent years, solar power system installation imposes several challenges on the operations of local and regional power grids due to the inherent variability of ground-level solar irradiance. This work proposes a novel real-time solar forecast methodology for intra-hour solar irradiance based on deep transfer learning from ground-based sky imager for time horizons ranging from 5-15 min. There are three unique aspects of the proposed methodology: (1) a Deep Learning based algorithm development which is modeled as a classification approach rather than a traditional regression approach; (2) the use of the Transfer Learning technique to show generalization capability, robustness, and portability of baseline model in the newly deployed location where availability of enough data for training is typically scarce, and (3) redefinition of point-based irradiation forecast error estimation technique with a window-based one that is more intuitive and user-friendly. The system is developed using multiple years of irradiance and sky image recording in New Jersey and one-year data from Colorado, USA. The method is validated against ground telemetry from these two locations of diverse geographic and climatic conditions. Results show that the forecasting method proposed in this work is robust and highly accurate (8% MAPE error) for multiple locations deployment.

Deep Learning, Convolution Neural Networks, transf↗

Method and system for compact efficient laser architecture

A laser amplifier module having an enclosure includes an input window, a mirror optically coupled to the input window and disposed in a first plane, and a first amplifier head disposed along an optical amplification path adjacent a first end of the enclosure. The laser amplifier module also includes a second amplifier head disposed along the optical amplification path adjacent a second end of the enclosure and a cavity mirror disposed along the optical amplification path.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of Helium Flow Visualization Apparatus for Studies of Blanket Cooling in Fusion Reactors

Flow visualization is essential to understanding helium cooling performance. This article investigates helium flow visualization in an apparatus to support the design of the blanket first wall for a fusion reactor. Helium’s safety advantages make it an attractive coolant, but effective cooling and flow visualization remain challenging. Sophisticated simulations are conducted in different test sections to address three key areas in the design of a test apparatus and cooling channel enhancements: the influence of viewing glass windows on flow patterns, the impact of increased heating, and the effectiveness of cooling structures like baffles. Viewing glass windows introduce flow recirculation region bifurcation and flow asymmetry, affecting flow patterns and necessitating careful analysis in future experiments. Increased heating results in helium flow detachment from the heated surface, leading to hot spots. Cooling structures, particularly baffles, prove effective in maintaining consistent attachment to the heated surface, improving the heat transfer performance. Further, this study also examines a tunable parameter in the turbulence model, highlighting the importance of accurate model tuning for future fusion reactor cooling designs. With an imminent helium flow visualization facility, these simulations will be used to optimize cooling structures on the heated wall to improve flow attachment and heat transfer efficiency. This work serves as a first investigation of the helium flow visualization apparatus for blanket cooling enhancement in fusion reactor design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coupled Cluster Green's function formulations based on the effective Hamiltonians

In this work, we demonstrate that the effective Hamiltonians obtained with the downfolding procedure based on double unitary coupled cluster (DUCC) ansatz can be used in the context of Green’s function coupled cluster (GFCC) formalism to calculate spectral functions of molecular systems. This combined approach (DUCC-GFCC) provides a significant reduction of numerical effort and good agreement with the corresponding all-orbital GFCC methods in energy windows that are consistent with the choice of active space. These features are demonstrated on the example of two benchmark systems: H 2 O and N 2 , where DUCC-GFCC calculations were performed for active spaces of various sizes.

74 ATOMIC AND MOLECULAR PHYSICS↗

Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗

Defining the Prototype Convenience Store Building Characteristics

The US Department of Energy supports the development of commercial building energy codes and standards. To support commercial building energy research activities and the development of commercial building energy codes and standards, continuous efforts have been made to convert 30 prototype building models (20 different building types), which cover 80% of US commercial building floor space, to OpenStudio prototype buildings. Additionally, the suite of prototype building models was expanded to include the addition of new building prototype models (e.g., courthouse, college building). This report documents the building and system characteristics of the prototype convenience store building model. Multiple sources, including databases, documented projects, and personal communications, were used to define the prototype convenience store building characteristics, and a one-story, 3,000 ft 2 building was considered as the prototype convenience store to represent an average-sized convenience store in the United States. The Oak Ridge National Laboratory team defined the operational hours of the convenience store as 17 hours per day. The types of exterior walls, roof, and floor were defined as brick wall, metal surfacing roof, and slab-on-grade floor, respectively. Double glazing was selected, and the window-towall ratio was set as 15% on the front side. For the system part, packaged system and centralized water heater were selected for the space heating and cooling system and water heater system, respectively. In terms of the refrigerator system, the number of refrigerators and freezers were determined as eight closed cases and two walk-in units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The real-time data processing and acquisition system for Project 8 Phase II

In Phase II of the Project 8 neutrino mass experiment, electrons from the decays of tritium or 83 m Kr are detected via their ≈ 26GHz cyclotron radiation while contained within a circular waveguide. The signal from a given electron is characterized as a brief chirp, lasting ≲ 10ms and changing in frequency by ≲ 1MHz/ms. To detect these signals, the Project 8 collaboration developed a Data Acquisition (DAQ) system tailored to the signal properties. The DAQ is responsible for simultaneously selecting up to three 100MHz-wide frequency windows to study, detect, and trigger on likely signals from different electron kinetic energies, and for writing the relevant data to disk. We describe the Phase II DAQ system in detail and address how the system was used for data-taking operations.

Ashtari Esfahani, A. [Washington U., Seattle; Shar↗

Effects of delta ray electrons on measurement uncertainties of harp system

A harp system, which is a multi-wire beam profile monitoring (MWPM) system, is planned upstream of the spallation target to make in situ calibration of beam current density configuration on the target along with beam imaging from luminescent coating on the beam entrance window at the Second Target Station (STS) of the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). This beam interception-based beam diagnostics system on the target will be used to ensure that the maximum beam loads on the target are within the design range during neutron production. Current design of the harp consists of three layers of measurement wires each of which is sandwiched between voltage biasing wire planes. The signal obtained from each measurement wire layer is disturbed by secondary electrons (SE) and delta rays produced by beam-matter interactions in neighboring wires and ionization of residual gases in accelerator vacuum. While the backgrounds from SE can be suppressed by voltage biasing, the delta-ray electrons with kinetic energies above keV ranges overcome the electric potential bias. In this paper, we study the effects of delta-rays on the measurement uncertainties of MWPM using the particle transport simulation code FLUKA. Furthermore, the cases where the harp system is installed in the proximity of a large delta ray sources such as proton beam window or in the core vessel filled with sub-atmospheric gas have been studied.

Lee, Yong Joong↗

On Transforming the Specific Force Vector for an ECEF Inertial Navigation System

An inertial measurement unit accumulates the instantaneous specific force applied to the sensor over a small window of time. Importantly, this accumulation occurs in the sensor’s frame, yet the specific force must be mathematically integrated in a different navigation frame, and these two frames may be rotating with respect to each other. Consequently, a correction is needed to not only account for the frame difference but also for the time variation in the frame difference. Many references provide derivations of this correction [1], but the derivation is often abbreviated, and important assumptions are sometimes left unstated. This memo addresses this gap and provides a clear derivation of the specific force transform with all assumptions specifically stated. This derivation is specific to the Earth-centered, Earth-fixed navigation frame, but, hopefully, the derivation is sufficiently clear that readers can apply it to other navigation frames. Generally, notation follows the same format as described in both [1, 2].

47 OTHER INSTRUMENTATION↗