Search NASA⌕ Search

SEARCH · Search NASA

Results for “X ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Optics Developments for X-Ray Astronomy

X‐ray optics has revolutionized x‐ray astronomy. The degree of background suppression that these afford, have led to a tremendous increase in sensitivity. The current Chandra observatory has the same collecting area (approx. 10(exp 3)sq cm) as the non‐imaging UHURU observatory, the first x‐ray observatory which launched in 1970, but has 5 orders of magnitude more sensitivity due to its focusing optics. In addition, its 0.5 arcsec angular resolution has revealed a wealth of structure in many cosmic x‐ray sources. The Chandra observatory achieved its resolution by using relatively thick pieces of Zerodur glass, which were meticulously figured and polished to form the four‐shell nested array. The resulting optical assembly weighed around 1600 kg, and cost approximately $0.5B. The challenge for future x‐ray astronomy missions is to greatly increase the collecting area (by one or more orders of magnitude) while maintaining high angular resolution, and all within realistic mass and budget constraints. A review of the current status of US optics for x‐ray astronomy will be provided along with the challenges for future developments.

Ramsey, Brian↗

Observations of the binary X-ray source SMC X-1 from OSO-7.

The X-ray source was observed with an X-ray telescope during the time from April 15, 1972 to May 25, 1972. These observations complement the Uhuru results reported by Schreier et al. (1972) and permit an extension of the spectrum to at least 35 keV. Combined with other observations, the data could help determine long term periodic variations, if any exist. The relative exposure and the corrected counting rate of the X-ray telescope during the precession of the satellite axis are shown in a graph.

Ulmer, M. P.↗

Irregular X-ray variability in the transient X-ray burst source MXB 1659-29

Irregular variability in the X-ray emission from MXB 1659-29 was observed with SAS 3 during the 1978 transient outburst of the source. No stable period can yet be derived from the low-intensity states, although there is evidence for a quasi-periodicity of either 1.2 or 1.4 hours. The low-intensity states observed in MXB 1659-29 during the transient outburst vary both in width and duration, similar to those in MXB 1916-05. The SAS 3 data are consistent with either the intermittent obscuration of the X-ray emitter by relatively cold gas or with scattering of the X-rays by hotter material.

Cominsky, L.↗

Galactic X-ray polarimetry and high-resolution X-ray spectroscopy.

Stellar X-ray spectroscopy and polarimetry are discussed in terms of the source parameters that can be determined through such studies and in terms of the constraints that these studies will place on theoretical models. The spectroscopic and polarimetric results that have been obtained to date are reviewed. These include the recent discovery of X-ray polarization in the Crab Nebula and the recent evidence for X-ray coronal line emission in the Cygnus Loop. Finally, the properties and predicted performance of a number of satellite-borne spectrometers and polarimeters are presented.

Novick, R.↗

Correction and verification of x-ray imaging crystal spectrometer analysis on Wendelstein 7-X through x-ray ray tracing

X-ray ray tracing is used to develop ion-temperature corrections for the analysis of the X-ray Imaging Crystal Spectrometer (XICS) used at Wendelstein 7-X (W7-X) and perform verification on the analysis methods. The XICS is a powerful diagnostic able to measure ion-temperature, electron-temperature, plasma flow, and impurity charge state densities. While these systems are relatively simple in design, accurate characterization of the instrumental response and validation of analysis techniques are difficult to perform experimentally due to the requirement of extended x-ray sources. For this reason, a ray tracing model has been developed that allows characterization of the spectrometer and verification of the analysis methods while fully considering the real geometry of the XICS system and W7-X plasma. Through the use of ray tracing, several important corrections have been found that must be accounted for in order to accurately reconstruct the ion-temperature profiles. The sources of these corrections are described along with their effect on the analyzed profiles. The implemented corrections stem from three effects: (1) effect of sub-pixel intensity distribution during de-curving and spatial binning, (2) effect of sub-pixel intensity distribution during forward model evaluation and generation of residuals, and (3) effect of defocus and spherical aberrations on the instrumental response. Possible improvements to the forward model and analysis procedures are explored, along with a discussion of trade-offs in terms of computational complexity. Finally, the accuracy of the tomographic inversion technique in stellarator geometry is investigated, providing for the first time a verification exercise for inversion accuracy in stellarator geometry and a complete XICS analysis tool-chain.

47 OTHER INSTRUMENTATION↗

Interfacial properties in energy storage systems studied by soft x-ray absorption spectroscopy and resonant inelastic x-ray scattering

Interfacial behaviors and properties play critical roles in determining key practical parameters of electrochemical energy storage systems, such as lithium-ion and sodium-ion batteries. Soft x-ray spectroscopy features shallow penetration depth and demonstrates inherent surface sensitivity to characterize the interfacial behavior with elemental and chemical sensitivities. Here, we present a brief survey of modern synchrotron-based soft x-ray spectroscopy of the interface in electrochemical energy storage systems. The technical focus includes core-level spectroscopy of conventional x-ray absorption spectroscopy and resonant inelastic x-ray scattering (RIXS). We show that while conventional techniques remain powerful for probing the chemical species on the surface, today’s material research studies have triggered much more demanding chemical sensitivity that could only be offered by advanced techniques such as RIXS. Another direction in the field is the rapid development of various in situ/operando characterizations of complex electrochemical systems. Notably, the solid-state battery systems provide unique advantages for future studies of both the surface/interface and the bulk properties under operando conditions. We conclude with perspectives on the bright future of studying electrochemical systems through these advanced soft x-ray spectroscopic techniques.

25 ENERGY STORAGE↗

First Terrestrial Soft X-Ray Auroral Observation by the Chandra X-Ray Observatory

Northern auroral regions of Earth were imaged with energetic photons in the 0.1-10keV range using the High-Resolution Camera (HRC-I) aboard the Chandra X-ray Observatory at 10 epochs (each approx.20 min duration) between mid- December 2003 and mid-April 2004. These observations aimed at searching for Earth's soft (< 2 keV) X-ray aurora in a comparative study with Jupiter's X-ray aurora, where a pulsating X-ray "hot-spot" has been previously observed by Chandra. The first Chandra soft X-ray observations of Earth's aurora show that it is highly variable 0ntense arcs, multiple arcs, diffuse patches, at times absent). In at least one of the observations an isolated blob of emission is observed near the expected cusp location. A fortuitous overflight of DMSP satellite F13 provided SSJ/4 energetic particle measurements above a bright arc seen by Chandra on 24 January 2004, 20:01-20:22 UT. A model of the emissions expected strongly suggests that the observed soft X-ray signal is bremsstrahlung and characteristic K-shell line emissions of nitrogen and oxygen in the atmosphere produced by electrons.

Bhardwaj, Anil↗

Redox Mechanisms and Migration Tendencies in Earth-Abundant 0.7Li 2 MnO 3 ·0.3LiFeO 2 Cathodes: Coupling Spin-Resolved X-ray Absorption Near Edge and X-ray Absorption Fine Structure Spectroscopies

We report the use of iron 1s3p resonant X-ray emission processes to conduct spin-selective, high-energy resolution fluorescence detected X-ray absorption near-edge spectroscopy (HERFD-XANES) on an iron-containing, lithium- and manganese-rich, fully earth-abundant cathode material, Li 1.3 Mn 0.5 Fe 0.2 O 2 (0.7Li 2 MnO 3 ·0.3LiFeO 2 ). Coupling this technique with conventional Mn K-edge XANES and detailed extended X-ray absorption fine structure (EXAFS) analysis from both the Mn and Fe vantage points, we gain fundamental insights into the redox processes and migration tendencies of transition metals in this cathode material at the bulk level. We show that during the first charge, Fe 3+ undergoes oxidation to form Fe 4+ prior to the activation plateau. Toward the end of activation, a significant fraction of the iron is present as tetrahedral Fe 3+ . This observation reveals that iron migration from octahedral to tetrahedral sites and iron reduction are initiated during activation. Upon first discharge from the activated state, a continuous and overlapping reduction of both Fe and Mn is observed, with Fe largely restored back as an octahedrally coordinated Fe 3+ . The manganese local environment gradually changes to a distorted cooperative Jahn–Teller Mn 3+ structure during discharge, with the clear presence of two Mn–O as well as two Mn–Mn correlation distances at 2.0 V. The significant reduction of manganese in the very first discharge is distinctly different from that seen in typical nickel-based lithium-manganese-rich materials but is similar to that observed for pure Li 2 MnO 3 . In conclusion, these findings shed light on key structure–property correlations in the cathode material and point to a causative relationship between the redox mechanisms as well as structural changes endured by the material and relatively poor performance during extended electrochemical cycling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the characteristic X ray of oxygen and other ultrasoft X rays using mercuric iodide detectors

This letter reports the detection and resolution of the characteristic X-ray of oxygen at 523 eV and other ultrasoft X-rays (photons energy less than 1 keV) using radiation detectors fabricated from the compound semi-insulator mercuric iodide (HgI2). These detectors are capable of operation at room ambient but in these experiments were slightly cooled using a Peltier element to 0 C. A pulsed light feedback preamplifier with a Peltier element cooled (to -30 deg) first stage field-effect transistor was used to amplify signals from the detector. Overall system noise level was 185 eV (full width at half-maximum) limited by the temperature of the first stage field-effect transistor. With optimal cooling of this element the characteristic X-ray of carbon at 282 eV should be measurable. These results would seem to be important in measurement of biological samples in electron column instruments.

Iwanczyk, J. S.↗

FPGA-Based X-Ray Detection and Measurement for an X-Ray Polarimeter

This technology enables detection and measurement of x-rays in an x-ray polarimeter using a field-programmable gate array (FPGA). The technology was developed for the Gravitational and Extreme Magnetism Small Explorer (GEMS) mission. It performs precision energy and timing measurements, as well as rejection of non-x-ray events. It enables the GEMS polarimeter to detect precisely when an event has taken place so that additional measurements can be made. The technology also enables this function to be performed in an FPGA using limited resources so that mass and power can be minimized while reliability for a space application is maximized and precise real-time operation is achieved. This design requires a low-noise, charge-sensitive preamplifier; a highspeed analog to digital converter (ADC); and an x-ray detector with a cathode terminal. It functions by computing a sum of differences for time-samples whose difference exceeds a programmable threshold. A state machine advances through states as a programmable number of consecutive samples exceeds or fails to exceed this threshold. The pulse height is recorded as the accumulated sum. The track length is also measured based on the time from the start to the end of accumulation. For track lengths longer than a certain length, the algorithm estimates the barycenter of charge deposit by comparing the accumulator value at the midpoint to the final accumulator value. The design also employs a number of techniques for rejecting background events. This innovation enables the function to be performed in space where it can operate autonomously with a rapid response time. This implementation combines advantages of computing system-based approaches with those of pure analog approaches. The result is an implementation that is highly reliable, performs in real-time, rejects background events, and consumes minimal power.

Gregory, Kyle↗

Study of the polarization dependence of the photoelectric effect in the soft X-ray band - A focal plane photoelectric stellar X-ray polarimeter for the Spectrum-X-Gamma mission

An experimental study of the polarization dependence of the photoelectric effect in cesium iodide in the soft X-ray band was started (Heckler et al., 1989). At a grazing angle of 10 degrees and a photon energy of 2.6 keV, it is found that the photoelectric yield from a thin layer of evaporated cesium iodide varies by 12.4 percent as the polarization vector of the incident X-ray beam is rotated about the line-of-sight. The rotation angle corresponding to the maximum photoyield is displaced by 16 degrees from the normal to the photocathode. This modulation and phase shift are in good agreement with the results recently reported by Fraser, et al. (1989) It is shown that a focal plane stellar X-ray polarimeter based on this photoelectric effect will be substantially more efficient than convential X-ray polarimeters such as those based on either Bragg reflection or scattering from low atomic number targets.

Heckler, A.↗

A Flat Analyzer Polycapillary Spectrometer for X-ray Absorption Spectroscopy of Dilute Transition Metals at X-ray-Free Electron Lasers

X-ray absorption spectroscopy (XAS) coupled with highly intense pulses from an X-ray-free electron laser (XFEL) can be used to track ultrafast chemical dynamics. Nonetheless, measurements for dilute samples (≤1 mM) have been exceptionally challenging, as scattering background signals dominate over the sample’s X-ray fluorescence. We show that femtosecond time-resolved XAS measurements of sub-millimolar transition metal solutions are now possible at the Linac Coherent Light Source (LCLS) using a high-throughput polycapillary XAS spectrometer, designed, developed, and commissioned at LCLS and the Stanford Synchrotron Radiation Lightsource (SSRL). The instrument integrates three polycapillary optics that collect and collimate X-ray fluorescence emitted from the interaction point with a high solid angle. X-ray collimated fluorescence is then selectively diffracted by coupled graphite analyzer crystals. As a result, the contribution of scattered photons is suppressed. Experiments at the Pt L 3 -edge on 0.1 mM aqueous K 2 PtCl 6 (delivered via a 100 μm liquid jet) were successfully performed in the laser pump X-ray probe configuration at the LCLS XCS and XPP instruments. We report the transient spectra of hexachloroplatinate within the first 10 ps after a 266 nm photoexcitation. We observed a short-lived reduced intermediate (≈2 ps). The polycapillary X-ray spectrometer at LCLS now enables the efficient study of the dynamics of ultradilute transition metals in solution. This capability opens the door to investigating plasmonic systems, photocatalysts, enzymes, and other scarce and dilute samples.

LCLS↗

Observational techniques for solar flare gamma-rays, hard X-rays, and neutrons

The development of new instrumentation and techniques for solar hard X-ray, gamma ray and neutron observations from spacecraft and/or balloon-borne platforms is examined. The principal accomplishments are: (1) the development of a two segment germanium detector which is near ideal for solar hard X-ray and gamma ray spectroscopy; (2) the development of long duration balloon flight techniques and associated instrumentation; and (3) the development of innovative new position sensitive detectors for hard X-ray and gamma rays.

Lin, Robert P.↗

Effect of X-ray flux on polytetrafluoroethylene in X-ray photoelectron spectroscopy

The effect of the X-ray flux in X-ray photoelectron spectroscopy (STAT) on the constitution of the polytetrafluoroethylene (PTFE) surface has been examined. The radiation dose rate for our specimen was about 10 to the 7th rad/s. The structure, magnitude and binding energy of the C(1s) and F(1s) features of the XPS spectrum and the mass spectrum of gaseous species evolved during irradiation are observed. The strong time dependence of these signals over a period of several hours indicated that the surface constitution of PTFE is greatly affected by this level of radiation dose. The results are consistent with the development of a heavily cross-linked or branched structure in the PTFE surface region and the evolution of short chain fragments into the gas phase.

Wheeler, D. R.↗

X-ray studies of coeval star samples. III - X-ray emission in the Ursa Major stream

Results are reported from a comprehensive survey of X-ray emission from stars known or suspected to be members of the UMa cluster and/or stream. Of the 42 UMa member stars surveyed, 18 were detected as X-ray sources, and spectral analysis was performed for 10 stars with sufficient X-ray counts. Consideration is given to relations between X-ray luminosity, color, and kinematics of the sample stars, and the X-ray spectra of the UMa stars are discussed in the context of the general problem of stellar X-ray temperatures. Also confirmed is the lack of X-ray-emitting A dwarfs among UMa members; among stars of later spectra type there is a rather large dispersion in X-ray luminosity. This dispersion cannot readily be explained by contamination with field star interlopers and appears rather to be a property of the UMa X-ray luminosity distribution function.

Schmitt, J. H. M. M.↗

Optical study of the X-ray binary Hercules X-1

The 1.7 day B-V light curve of HZ Herculis shows the existence of a small hot component which is present only during the X-ray active portion of the 35-day cycle. This hot component is associated with the X-ray source since it is absent during X-ray eclipse.

Saint John, R. H.↗