Observations of the artificially injected Porcupine xenon ion beam in the ionosphere

Results are given of ion beam injection experiments performed in the auroral ionosphere in connection with the German Sounding Rocket Project Porcupine. A heavy (xenon) ion beam was injected into the collisionless ionospheric plasma approximately perpendicular to the ambient magnetic field at altitudes from 190 km to about 450 km. The beam propagates nearly undistorted across the plasma because it is essentially depolarized; at the same time the beam is not current neutralized. This unexpected behavior poses the interconnected problems of how the beam manages to become charge neutralized, how current closure is maintained, and what is the mechanism of depolarization.

Haeusler, B.↗

Crystal growth and transport rates of the GeSe-xenon system under microgravity conditions

The analysis of the STS-7 flight experiments of the GeSe-xenon system yielded positive results which surpass the original objectives of these experiments. The mass transport rates of GeSe observed in microgravity environment are in close agreement with theoretically predicted values for diffusion limited mass transport. This supports the earlier proposed hypothesis for the interpretation of flux anomalies observed in previous space experiments. In addition, the STS-7 flight experiments led to the observation of unexpected crystal growth phenomena. The largest GeSe single crystals obtained in microgravity grew in the ampul without direct wall contact which could suggest homogeneous nucleation. The space grown crystals are much larger and have considerably improved surface and bulk morphologies relative to corresponding ground control specimens. The combined results are of basic scientific importance and of technological significance.

Wiedemeier, H.↗

Xenon and other noble gases in shergottites

The isotopic composition of the xenon component trapped in EETA 79001's lithologies B and C has been determined, and other noble gases were measured in some samples. The Xe component was found to have light isotope ratios indistinguishable from those of the terrestrial atmosphere. The trapped component has a Xe-129/Xe-132 ratio of about 2.4, and is enhanced in Xe-134 and Xe-136 relative to the terrestrial atmosphere or the average carbonaceous chondrite. Similarities between values for Ar-40/Ar-36, Xe-129/Xe-132, and N-15/N-14 and the corresponding Martian atmospheric values suggest Martian origin of the trapped gases.

Swindle, T. D.↗

Computer controlled operation of a two-engine xenon ion propulsion system

The development and testing of a computer control system for a two-engine xenon ion propulsion module is described. The computer system controls all aspects of the propulsion module operation including: start-up, steady-state operation, throttling and shutdown of the engines; start-up, operation and shutdown of the central neutralizer subsystem; control of the gimbal system for each engine; and operation of the valves in the propellant storage and distribution system. The most important engine control algorithms are described in detail. These control algorithms provide flexibility in the operation and throttling of ion engines which has never before been possible. This flexibility is made possible in large part through the use of flow controllers which maintain the total flow rate of propellant into the engine at the proper level. Data demonstrating the throttle capabilities of the engine and control system are presented.

Brophy, John R.↗

Internal erosion rates of a 10-kW xenon ion thruster

A 30 cm diameter divergent magnetic field ion thruster, developed for mercury operation at 2.7 kW, was modified and operated with xenon propellant at a power level of 10 kW for 567 h to evaluate thruster performance and lifetime. The major differences between this thruster and its baseline configuration were elimination of the three mercury vaporizers, use of a main discharge cathode with a larger orifice, reduction in discharge baffle diameter, and use of an ion accelerating system with larger acceleration grid holes. Grid thickness measurement uncertainties, combined with estimates of the effects of reactive residual facility background gases gave a minimum screen grid lifetime of 7000 h. Discharge cathode orifice erosion rates were measured with three different cathodes with different initial orifice diameters. Three potential problems were identified during the wear test: the upstream side of the discharge baffle eroded at an unacceptable rate; two of the main cathode tubes experienced oxidation, deformation, and failure; and the accelerator grid impingement current was more than an order of magnitude higher than that of the baseline mercury thruster. The charge exchange ion erosion was not quantified in this test. There were no measurable changes in the accelerator grid thickness or the accelerator grid hole diameters.

Rawlin, Vincent K.↗

Performance of 10-kW class xenon ion thrusters

Presented are performance data for laboratory and engineering model 30 cm-diameter ion thrusters operated with xenon propellant over a range of input power levels from approximately 2 to 20 kW. Also presented are preliminary performance results obtained from laboratory model 50 cm-diameter cusp- and divergent-field ion thrusters operating with both 30 cm- amd 50 cm-diameter ion optics up to a 20 kW input power. These data include values of discharge chamber propellant and power efficiencies, as well as values of specific impulse, thruster efficiency, thrust and power. The operation of the 30 cm- and 50 cm-diameter ion optics are also discussed.

Patterson, Michael J.↗

Internal erosion rates of a 10-kW xenon ion thruster

A 30 cm diameter divergent magnetic field ion thruster, developed for mercury operation at 2.7 kW, was modified and operated with xenon propellant at a power level of 10 kW for 567 h to evaluate thruster performance and lifetime. The major differences between this thruster and its baseline configuration were elimination of the three mercury vaporizers, use of a main discharge cathode with a larger orifice, reduction in discharge baffle diameter, and use of an ion accelerating system with larger acceleration grid holes. Grid thickness measurement uncertainties, combined with estimates of the effects of reactive residual facility background gases gave a minimum screen grid lifetime of 7000 h. Discharge cathode orifice erosion rates were measured with three different cathodes with different initial orifice diameters. Three potential problems were identified during the wear test: the upstream side of the discharge baffle eroded at an unacceptable rate; two of the main cathode tubes experienced oxidation, deformation, and failure; and the accelerator grid impingement current was more than an order of magnitude higher than that of the baseline mercury thruster. The charge exchange ion eroison was not quantified in this test. There were no measurable changes in the accelerator grid thickness or the accelerator grid hole diameters.

Rawlin, Vincent K.↗

Performance of large area xenon ion thrusters for orbit transfer missions

Studies have indicated that xenon ion propulsion systems can enable the use of smaller Earth-launch vehicles for satellite placement which results in significant cost savings. These analyses have assumed the availability of advanced, high power ion thrusters operating at about 10 kW or higher. A program was initiated to explore the viability of operating 50 cm diameter ion thrusters at this power level. Operation with several discharge chamber and ion extraction grid set combinations has been demonstrated and data were obtained at power levels to 16 kW. Fifty cm diameter thrusters using state of the art 30 cm diameter grids or advanced technology 50 cm diameter grids allow discharge power and beam current densities commensurate with long life at power levels up to 10 kW. In addition, 50 cm diameter thrusters are shown to have the potential for growth in thrust and power levels beyond 10 KW.

Rawlin, Vincent K.↗

Performance of 10-kW class xenon ion thrusters

Presented are performance data for laboratory and engineering model 30 cm-diameter ion thrusters operated with xenon propellant over a range of input power levels from approximately 2 to 20 kW. Also presented are preliminary performance results obtained from laboratory model 50 cm-diameter cusp- and divergent-field ion thrusters operating with both 30 cm- and 50 cm-diameter ion optics up to a 20 kW input power. These data include values of discharge chamber propellant and power efficiencies, as well as values of specific impulse, thruster efficiency, thrust and power. The operation of the 30 cm- and 50 cm-diameter ion optics are also discussed.

Patterson, Michael J.↗

Quench gases for xenon- (and krypton-) filled proportional counters

Xenon-filled proportional counters are used extensively in astronomy, particularly in the hard X-ray region. The choice of quench gas can have a significant effect on the operating characteristics of the instrument although the data necessary to make the choice are not easily obtainable. Results which detail the performance obtained from both cylindrical and parallel field geometries for a wide variety of readily available, ultrahigh or research grade purity, quench gases are presented.

Ramsey, B. D.↗

Performance of Large Area Xenon Ion Thrusters for Orbit Transfer Missions

Studies have indicated that xenon ion propulsion systems can enable the use of smaller earth-launch vehicles for satellite placement which results in significant cost savings. These analyses have assumed the availability of advanced, high power ion thrusters-operating at about 10 kW or higher. A program was initiated to explore the viability of operating 50 cm diameter ion thrusters at this power level. Operation with several discharge chamber and ion extraction grid set combinations was demonstrated and data were obtained at power levels to 16 kW. Fifty cm diameter thrusters using state of the art 30 cm diameter grids or advanced technology 50 cm diameter grids allow discharge power and beam current densities commensurate with long life at power levels up to 10 kW. In addition, 50 cm diameter thrusters are shown to have potential for growth in thrust and power levels beyond 10 kW.

Rawlin, Vincent K.↗

Multiple-ionization of xenon atoms by positron impact

Previously the cross sections were measured for positronium formation and single ionization by positron impact for He and H2. With the same apparatus, slightly modified, the single and multiple ionization of xenon is now investigated. The principle of the method is the detection of ion and positron in time correlation which allows the discrimination of positronium formation (whereby the positron vanishes) and the destinction of single, double and triple impact ionization (which lead to different ion flight times from the gas target to the ion detector). By using secondary electrons from the positron moderator, similar measurements were performed on electron impact ionization. By comparing with literature values for electron multiple ionization cross sections, the detection-probability ratios were determined for the differently charged ions.

Kruse, Georg↗

High-power xenon ion thrusters

Steady state performance characteristics for a 25-cm diameter laboratory-model xenon ion thruster operating over the power range from 1.8 to 6.8 kW are described. Performance data are also presented for a similar 30-cm diameter thruster operated over the 1.4 to 11.1 kW power range. For each of the two thrusters, thermal characteristics, discharge-chamber performance data, overall thruster performance data, and beam-current density profiles are presented. A high level of performance and stability over a wide range of input power is demonstrated for the two thrusters. It is concluded that there appears to be no technological obstacles in the way of developing flight-design thrusters that operate in the 5- to 10-kW power range for near-term applications to orbit raising.

Beattie, J. R.↗

Critical exponent for the viscosity of carbon dioxide and xenon

The viscosities of carbon dioxide and xenon have been measured near their critical points and the critical exponent y characterizing the asymptotic divergence has been determined. Both fluids yielded exponents in the range y = 0.041 + or - 0.001 and thus also fell in the range y = 0.042 + or - 0.002 from an earlier study of four binary liquids. This agreement between experiments is the first evidence that pure fluids and binary liquids are in the same dynamic universality class. A recent theoretical value for y is 0.032. The 30 percent discrepancy is much greater than the combined errors from experiment and theory. The torsion oscillator viscometer operated at low frequency and low shear rate to avoid systematic errors caused by critical slowing down. Far from T(c) the analysis accounted for the crossover from critical to noncritical temperature dependence, where the latter was obtained from previously published correlations. Corrections for gravitational stratification were included close to T(c).

Berg, R. F.↗

5kW xenon ion thruster lifetest

This paper describes the results of the first lifetest of a high power ring-cusp ion thruster. A 30-cm laboratory model thruster was operated steady-state at a nominal beam power of 5kW on xenon propellant for approximately 900 hours. This test was conducted to identify life-limiting erosion mechanisms and thruster design modifications, and to demonstrate operation using simplified power processing. The results from this test are described including the conclusions derived from extensive post-test analyses of the thruster. Modifications to the thruster and ground support equipment, which have been incorporated to solve problems identified by the lifetest, are also described.

Patterson, Michael J.↗

A 5-kW xenon ion thruster lifetest

The results of the first life test of a high power ring-cusp ion thruster are presented. A 30-cm laboratory model thruster was operated steady-state at a nominal beam power of 5 kW on xenon propellant for approximately 900 hours. This test was conducted to identify life-timing erosion modifications, and to demonstrate operation using simplified power processing. The results from this test are described including the conclusions derived from extensive post-test analyses of the thruster. Modifications to the thruster and ground support equipment, which were incorporated to solve problems identified by the lifetest, are also described.

Patterson, Michael J.↗

Development of a high resolution liquid xenon imaging chamber for gamma-ray astronomy

The objective was to develop the technology of liquid xenon (LXe) detectors for spectroscopy and imaging of gamma rays from astrophysical sources emitting in the low to medium energy regime. In particular, the technical challenges and the physical processes relevant to the realization of the LXe detector operated as a Time Projection Chamber (TPC) were addressed and studied. Experimental results were obtained on the following topics: (1) long distance drift of free electrons in LXe (purity); (2) scintillation light yield for electrons and alphas in LXe (triggering); and (3) ionization yield for electrons and gamma rays in LXe (energy resolution). The major results from the investigations are summarized.

Aprile, Elena↗

Extended testing of xenon ion thruster hollow cathodes

A hollow cathode wear-test of 508 hours was successfully completed at an emission current of 23.0 A and a xenon flow rate of 10 Pa-L/s. This test was the continuation of a hollow cathode contamination investigation. Discharge voltage was stable at 16.7 V. The cathode temperature averaged 1050 C with a 7 percent drop during the wear-test. Discharge ignition voltage was found to be approximately 20 V and was repeatable over four starts. Post-test analyses of the hollow cathode found a much improved internal cathode condition with respect to earlier wear-test cathodes. Negligible tungsten movement occurred and no formation of mono-barium tungstate was observed. These results correlated with an order-of-magnitude reduction in propellant feed-system leakage rate. Ba2CaWO6 and extensive calcium crystal formation occurred on the upstream end of the insert. Ba-Ca compound depositions were found on the Mo insert collar, on the Re electrical leads, and in the gap between the insert and cathode wall. This wear-test cathode was found to be in the best internal condition and had the most stable operating performance of any hollow cathode tested during this contamination investigation.

Sarver-Verhey, Timothy R.↗