Results for “ablators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Physics of picosecond pulse laser ablation

This study investigates the physical processes involved in picosecond pulse (20-28 ps FWHM) laser ablation of Al 6061, 316L stainless steel, and undoped crystalline Si ($\langle$100$\rangle$) over a range of laser wavelength (355 nm and 1064 nm) and fluence (0.1-40 J/cm 2 ). Experimental measurements of material ablation rate show enhanced removal at the 355 nm wavelength, primarily due to laser-plasma interaction (LPI) within the ablative plume that approaches an order of magnitude increase over the measured removal at 1064 nm. A transition in the ablation rate at 355 nm is identified around ~10 J/cm 2 above which the removal efficiency increases by a factor of two to three. Multi-physics radiation hydrodynamic simulations, considering LPI effects and utilizing a novel mixed-phase equation of state model, show that the transition in ablation efficiency is due to the onset of melt ejection through cavitation, where laser-driven shock heating sets the depth of melt penetration and the ensuing release wave from the ablation surface drives cavitation through the imposition of tensile strain within the melt. High-speed pump-probe imaging of the ejecta and ejecta collection studies, as well as scanning electron microscopy of the ablation craters, support the proposed cavitation mechanism in the higher fluence range. The ablation process is vitally influenced by LPI effects and the thermophysical properties of the material.

36 MATERIALS SCIENCE↗

Exploratory development of a flexible ablative covering for space shuttle application

An applied research program is considered for a preliminary design and development of a flexible ablative covering for the space shuttle vehicle that could be easily replaced and/or refurbished. The program was structured to concentrate resources on the major technical problem areas associated with the flexible ablator concept. These areas included: (1) fabrication of a suitable woven carpet reinforcement, (2) modification of a flexible ablator formulation for filling the woven carpet construction, and (3) testing of the flexible ablator concept. Several approaches were evaluated to obtain a flexible ablator. The final recommended solution was one in which the ablative filler was based on a low-density formulation of the elastomeric shield material series (ESM). The preferred approach is one in which a light-weight fabric backing is bonded to preformed and fully cured ESM, and the composite tufted with Astroquartz fiber to the desired tuft or pile density. Ablation tests performed in a hyperthermal arc facility demonstrated the ablation performance of the concept and overshoot capability of the system.

Hiltz, A. A.↗

On the origin of extraterrestrial stratospheric particles: Interplanetary dust or meteor ablation debris?

Meteor ablation debris was distinguished from unablated interplanetary dust in a collection of extraterrestrial particles collected in the stratosphere using NASA U-2 aircraft. A 62 g sample of the Murchison (C2) meteorite was artificially ablated to characterize ablation debris for comparison with the stratospheric particles. By using proper experimental conditions, artificial ablation debris can be produced that is similar to natural ablation debris. Analyses of natural fusion crusts, artificial fusion crust, and artificial ablation debris of the Murchison meteorite produced criteria for recognizing debris ablated by a primitive meteoroid. Ninety-five percent of the stratospheric particles can be described as either ablation debris from a primitive meteoroid, or as very primitive interplanetary dust.

Kyte, F. T.↗

Design and Laboratory Validation of a Capacitive Sensor for Measuring the Recession of Thin-Layered Ablator

Flight vehicles are typically instrumented with subsurface thermocouples to estimate heat transfer at the surface using inverse analysis procedures. If the vehicle has an ablating heat shield, however, temperature time histories from subsurface thermocouples no longer provide enough information to estimate heat flux at the surface. In this situation, the geometry changes and thermal energy leaves the surface in the form of ablation products. The ablation rate is required to estimate heat transfer to the surface. A new concept for a capacitive sensor has been developed to measure ablator depth using the ablator's dielectric effect on a capacitor's fringe region. Relying on the capacitor's fringe region enables the gage to be flush mounted in the vehicle's permanent structure and not intrude into the ablative heat shield applied over the gage. This sensor's design allows nonintrusive measurement of the thickness of dielectric materials, in particular, the recession rates of low-temperature ablators applied in thin (0.020 to 0.060 in. (0.05 to 0.15 mm)) layers. Twenty capacitive gages with 13 different sensing element geometries were designed, fabricated, and tested. A two-dimensional finite-element analysis was performed on several candidate geometries. Calibration procedures using ablator-simulating shims are described. A one-to-one correspondence between system output and dielectric material thickness was observed out to a thickness of 0.055 in. (1.4 mm) for a material with a permittivity about three times that of air or vacuum. A novel method of monitoring the change in sensor capacitance was developed. This technical memorandum suggests further improvements in gage design and fabrication techniques.

Gregory K Noffz↗

Transient Ablation of Teflon Hemispheres

For high-speed entry of space vehicles into atmospheric environments, ablation is a practical method for alleviating severe aerodynamic heating. Several studies have been undertaken on steady or quasi-steady ablation. However, ablation is a very complicated phenomenon in which a nonequilibrium chemical process is associated with an aerodynamic process that involves changes in body shape with time. Therefore, it seems realistic to consider that ablation is an unsteady phenomenon. In the design of an ablative heat-shield system, since the ultimate purpose of the heat shield is to keep the internal temperature of the space vehicle at a safe level during entry, the transient heat conduction characteristics of the ablator may be critical in the selection of the material and its thickness. This note presents an experimental study of transient ablation of Teflon, with particular emphasis on the change in body shape, the instantaneous internal temperature distribution, and the effect of thermal expansion on ablation rate.

Arai, Norio↗

Influence of Coupled Radiation and Ablation on the Aerothermodynamic Environment of Planetary Entry Vehicles

A review of recently published coupled radiation and ablation capabilities involving the simulation of hypersonic flowfields relevant to Earth, Mars, or Venus entry is presented. The three fundamental mechanisms of radiation coupling are identified as radiative cooling, precursor photochemistry, and ablation-radiation interaction. The impact of these mechanisms are shown to be significant for a 3 m radius sphere entering Earth at hypothetical Mars return conditions (approximately 15 km/s). To estimate the influence precursor absorption on the radiative flux for a wide range of conditions, a simplified approach is developed that requires only the non-precursor solution. Details of a developed coupled ablation approach, which is capable of treating both massively ablating flowfields in the sublimation regime and weakly ablating diffusion Climited oxidation cases, are presented. A review of the two primary uncoupled ablation approximations, identified as the blowing correction and film coefficient approximations, is made and their impact for Earth and Mars entries is shown to be significant for recession and convective heating predictions. Fully coupled ablation and radiation simulations are presented for the Mars return sphere throughout its entire trajectory. Applying to the Mars return sphere the Pioneer- Venus heritage carbon phenolic heatshield, which has properties available in the open literature, the differences between steady state ablation and coupling to a material response code are shown to be significant.

Johnston, Christopher O.↗

Testing of Advanced Conformal Ablative TPS

In support of the CA250 project, this paper details the results of a test campaign that was conducted at the Ames Arcjet Facility, wherein several novel low density thermal protection (TPS) materials were evaluated in an entry like environment. The motivation for these tests was to investigate whether novel conformal ablative TPS materials can perform under high heat flux and shear environment as a viable alternative to rigid ablators like PICA or Avcoat for missions like MSL and beyond. A conformable TPS over a rigid aeroshell has the potential to solve a number of challenges faced by traditional rigid TPS materials (such as tiled Phenolic Impregnated Carbon Ablator (PICA) system on MSL, and honeycomb-based Avcoat on the Orion Multi Purpose Crew Vehicle (MPCV)). The compliant (high strain to failure) nature of the conformable ablative materials will allow better integration of the TPS with the underlying aeroshell structure and enable monolithic-like configuration and larger segments to be used in fabrication.A novel SPRITE1 architecture, developed by the researchers at NASA Ames was used for arcjet testing. This small probe like configuration with 450 spherecone, enabled us to test the materials in a combination of high heat flux, pressure and shear environment. The heat flux near the nose were in the range of 500-1000 W/sq cm whereas in the flank section of the test article the magnitudes were about 50 of the nose, 250-500W/sq cm range. There were two candidate conformable materials under consideration for this test series. Both test materials are low density (0.28 g/cu cm) similar to Phenolic Impregnated Carbon Ablator (PICA) or Silicone Impregnated Refractory Ceramic Ablator (SIRCA) and are comprised of: A flexible carbon substrate (Carbon felt) infiltrated with an ablative resin system: phenolic (Conformal-PICA) or silicone (Conformal-SICA). The test demonstrated a successful performance of both the conformable ablators for heat flux conditions between 50-500 W/sq cm. The recession and temperature profile for these materials were comparable to PICA proving them to be viable alternatives for TPS technology development for future missions.

Gasch, Matthew↗

Flexible Ablators: Applications and Arcjet Testing

Flexible ablators were conceived in 2009 to meet the technology pull for large, human Mars Exploration Class, 23 m diameter hypersonic inflatable aerodynamic decelerators. As described elsewhere, they have been recently undergoing initial technical readiness (TRL) advancement by NASA. The performance limits of flexible ablators in terms of maximum heat rates, pressure and shear remain to be defined. Further, it is hoped that this emerging technology will vastly expand the capability of future NASA missions involving atmospheric entry systems. This paper considers four topics of relevance to flexible ablators: (1) Their potential applications to near/far term human and robotic missions (2) Brief consideration of the balance between heat shield diameter, flexible ablator performance limits, entry vehicle controllability and aft-body shear layer impingement of interest to designers of very large entry vehicles, (3) The approach for developing bonding processes of flexible ablators for use on rigid entry bodies and (4) Design of large arcjet test articles that will enable the testing of flexible ablators in flight-like, combined environments (heat flux, pressure, shear and structural tensile loading). Based on a review of thermal protection system performance requirements for future entry vehicles, it is concluded that flexible ablators have broad applications to conventional, rigid entry body systems and are enabling to large deployable (both inflatable and mechanical) heat shields. Because of the game-changing nature of flexible ablators, it appears that NASA's Office of the Chief Technologist (OCT) will fund a focused, 3-year TRL advancement of the new materials capable of performance in heat fluxes in the range of 200-600 W/sq. cm. This support will enable the manufacture and use of the large-scale arcjet test designs that will be a key element of this OCT funded activity.

Thermal Protection↗

Ablation and Heating During Atmospheric Entry and Its Effect on Airburst Risk

Large meteoroids and asteroids entering the atmosphere endure tremendous heating from the shock heated air, and thereby lose a significant fraction of their mass during atmospheric entry a process known as ablation. The predicted evolution of the asteroids mass as it passes through the atmosphere can affect both the predicted energy deposition profile relevant to an airburst event, or the residual mass that strikes the ground in the case of an impact event. This presentation is divided roughly into two parts. In the first part, an overview of traditional models for heat transfer and ablation that are historically used in the meteor physics community is presented, and the validity in the asteroid entry regime discussed. Sensitivity analyses performed using the recently developed Fragment-Cloud Model (FCM) will be presented which show illustrate the range of sizes and entry parameters for which the predicted asteroid threat is most sensitive to the models for ablation and heat transfer. The second part of the presentation shall focus on recent work done under NASAs Asteroid Threat Assessment Project (ATAP) to develop new models for heat transfer and ablation using high-fidelity numerical simulation in concert with state-of-the-art experiments. Coupled computational fluid dynamics (CFD)radiation transport simulations preformed using the state-of-the-art entry modeling tools at NASA show that, for large meteoroids and asteroids, there can significant attenuation of the heat transfer to the surface (95 in some cases) by the products of ablation. In addition to the heat transfer, new models for the material response and ablation of asteroidal material have been developed [cite]. In the current work, we present finding from recent novel experiments performed in the arc jet facility at NASA Ames, which allows us to, in part, simulate the extreme environment experienced by the asteroid during entry. Briefly, the experimental set-up was comprised of a 1.5 conical article of machined H5 chondrite, which was exposed to a high-enthalpy flow resulting in approximately 4 kWcm2 of heating to the surface. A still frame capture from high-speed video taken during this experiment can be seen in Figure 1. In this figure, we can observe some of the major mechanisms for meteoroid ablation, such as melt flow, spallation (mechanical removal of material), and vaporization. Major findings from this, and other experiments will be discussed, as well progress on utilizing the data from the experiments to inform and develop improved models for ablation.

Asteroids↗

Percutaneous Radiofrequency Lung Ablation Combined with Transbronchial Saline Injection: An Experimental Study in Swine

To evaluate the efficacy of radiofrequency lung ablation with transbronchial saline injection. The bilateral lungs of eight living swine were used. A 13-gauge bone biopsy needle was inserted percutaneously into the lung, and 1 ml of muscle paste was injected to create a tumor mimic. In total, 21 nodules were ablated. In the saline injection group (group A), radiofrequency ablation (RFA) was performed for 11 nodules after transbronchial saline injection under balloon occlusion with a 2-cm active single internally cooled electrode. In the control group (group B), conventional RFA was performed for 10 nodules as a control. The infused saline liquid showed a wedge-shaped and homogeneous distribution surrounding a tumor mimic. All 21 RFAs were successfully completed. The total ablation time was significantly longer (13.4 {+-} 2.8 min vs. 8.9 {+-} 3.5 min; P = 0.0061) and the tissue impedance was significantly lower in group A compared with group B (73.1 {+-} 8.8 {Omega} vs. 100.6 {+-} 16.6 {Omega}; P = 0.0002). The temperature of the ablated area was not significantly different (69.4 {+-} 9.1{sup o}C vs. 66.0 {+-} 7.9{sup o}C; P = 0.4038). There was no significant difference of tumor mimic volume (769 {+-} 343 mm{sup 3} vs. 625 {+-} 191 mm{sup 3}; P = 0.2783). The volume of the coagulated area was significantly larger in group A than in group B (3886 {+-} 1247 mm{sup 3} vs. 2375 {+-} 1395 mm{sup 3}; P = 0.0221). Percutaneous radiofrequency lung ablation combined with transbronchial saline injection can create an extended area of ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced Ablation of High Intensity Focused Ultrasound with Microbubbles: An Experimental Study on Rabbit Hepatic VX2 Tumors

Purpose: This study was designed to assess the enhanced effect of high intensity focused ultrasound (HIFU) ablation with microbubbles on rabbit hepatic VX2 tumors and to compare the detection sensitivity of CEUS and CECT to determine the residual viable tissue after ablation of HIFU. Methods: Forty rabbits with hepatic VX2 tumors were randomly separated into two groups (20 animals per group) before HIFU ablation. A bolus of 0.2 mL of saline or a microbubble-based ultrasound (US) contrast agent was injected intravenously to group I rabbits and group II rabbits, respectively. The HIFU ablation procedure was started 15 s after the injection. Tumors were examined with grayscale contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) immediately before and after HIFU ablation. Histopathologic assessment was performed immediately after treatment imaging. Results: Before ablation, intense contrast enhancement during arterial phase was observed at the whole tumors or the periphery of the tumors by CEUS and CECT. Lower HIFU energy was used in group II than in group I (P < 0.001). Histopathologic assessment revealed local residual viable tumor tissues due to incomplete ablation in 47.4% (9/19) of tumors in group I and 10% (2/20) of tumors in group II (P < 0.05). The concordance rate of CEUS (90.9%) with histopathology on residual tumor detection was higher than that of CECT (27.3%, P < 0.05). Conclusions: Introduction of the microbubble agent enhances HIFU therapeutic efficacy. CEUS proves to have high sensitivity in assessment of residual viable rabbit VX2 tumor after HIFU.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sustained Growth of the Ex Vivo Ablation Zones' Critical Short Axis Using Gas-cooled Radiofrequency Applicators

Purpose: To evaluate the ablation zones created with a gas-cooled bipolar radiofrequency applicator performed on ex vivo bovine liver tissue. Materials and Methods: A total of 320 ablations with an internally gas-cooled bipolar radiofrequency applicator were performed on fresh ex vivo bovine liver tissue, varying the ablation time (5, 10, 15, and 20 min), power (20, 30, 40, and 50 W), and gas pressure of the CO{sub 2} used for cooling (585, 600, 615, 630, 645 psi), leading to a total of 80 different parameter combinations. Size and shape of the white coagulation zone were assessed. Results: The largest complete ablation zone was achieved after 20 min of implementing 50 W and 645 psi, resulting in a short axis of mean 46 {+-} 1 mm and a long axis of 56 {+-} 2 mm (mean {+-} standard deviation). Short-axis diameters increased between 5 and 20 min of ablation time at 585 psi (increase of the short axis was 45% at 30 W, 29% at 40 W, and 39% at 50 W). This increase was larger at 645 psi (113% at 30 W, 67% at 40 W, and 70% at 50 W). Macroscopic assessment and NADH (nicotinamide adenine dinucleotide) staining revealed incompletely ablated tissue along the needle track in 18 parameter combinations including low-power settings (20 and 30 W) and different cooling levels and ablation times. Conclusion: Gas-cooled radiofrequency applicators increase the short-axis diameter of coagulation in an ex vivo setting if appropriate parameters are selected.

60 APPLIED LIFE SCIENCES↗

Percutaneous Irreversible Electroporation Lung Ablation: Preliminary Results in a Porcine Model

Objective: Irreversible electroporation (IRE) uses direct electrical pulses to create permanent 'pores' in cell membranes to cause cell death. In contrast to conventional modalities, IRE has a nonthermal mechanism of action. Our objective was to study the histopathological and imaging features of IRE in normal swine lung. Materials and Methods: Eleven female swine were studied for hyperacute (8 h), acute (24 h), subacute (96 h), and chronic (3 week) effects of IRE ablation in lung. Paired unipolar IRE applicators were placed under computed tomography (CT) guidance. Some applicators were deliberately positioned near bronchovascular structures. IRE pulse delivery was synchronized with the cardiac rhythm only when ablation was performed within 2 cm of the heart. Contrast-enhanced CT scan was performed immediately before and after IRE and at 1 and 3 weeks after IRE ablation. Representative tissue was stained with hematoxylin and eosin for histopathology. Results: Twenty-five ablations were created: ten hyperacute, four acute, and three subacute ablations showed alveolar edema and necrosis with necrosis of bronchial, bronchiolar, and vascular epithelium. Bronchovascular architecture was maintained. Chronic ablations showed bronchiolitis obliterans and alveolar interstitial fibrosis. Immediate post-procedure CT images showed linear or patchy density along the applicator tract. At 1 week, there was consolidation that resolved partially or completely by 3 weeks. Pneumothorax requiring chest tube developed in two animals; no significant cardiac arrhythmias were noted. Conclusion: Our preliminary porcine study demonstrates the nonthermal and extracellular matrix sparing mechanism of action of IRE. IRE is a potential alternative to thermal ablative modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Intraoperative Nerve Monitoring in Preventing Thermal Damage to the “Nerve at Risk” During Image-Guided Ablation of Tumors

PurposeTo assess feasibility of intraoperative neurophysiologic monitoring (IONM) during image-guided, percutaneous thermal ablation of tumors.Materials and MethodsFrom February 2009 to October 2013, a retrospective review of all image-guided percutaneous thermal ablation interventions using IONM was performed and data was compiled using electronic medical records and imaging studies.ResultsTwelve patients were treated in 13 ablation interventions. In 4 patients, real-time feedback from the monitoring neurologist was used to adjust applicator placement and ablation settings. IONM was technically feasible in all procedures and there were no complications related to monitoring or ablation. All nerves at risk remained intact and of the 11 patients who could be followed, none developed new nerve deficit up to a minimum of 2 months after ablation.ConclusionIONM is safe and feasible for use during image-guided thermal ablation of tumors in the vicinity of nerves. Outcomes in this study demonstrate its potential utility in image-guided ablation interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Results of Ultrasonography-Guided Percutaneous Radiofrequency Ablation in Hyperparathyroid Patients in Whom Surgery Is Not Feasible

BackgroundThe aim of the study was to evaluate the results of ultrasonography (US)-guided percutaneous radiofrequency ablation (RFA) in hyperparathyroid patients who refused surgery or had high surgical risks.Patients and MethodsFive patients with hyperparathyroidism (HPT) underwent US-guided RFA for a single hyperfunctioning parathyroid lesion. Post-ablation serum calcium and parathormone (PTH) assays were performed. All patients underwent imaging studies 6 months after the ablation to visualize the post-ablation change in the size of the treated parathyroid lesions.ResultsAll patients were normocalcemic on the post-ablation 1st day and 6th month. The post-ablation PTH levels were normal in three patients but remained elevated in two patients. The size of the parathyroid lesion was ≥30 mm in the two patients with elevated PTH, whereas the lesion was smaller than 30 mm in those with normal post-ablation PTH values.ConclusionAlthough this is a limited case series, it demonstrates the potential feasibility of RFA for HPT. Benefits were achieved particularly in patients with small parathyroid lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Infrared laser ablation of poly(vinylidene fluoride): The Loss of HF

The mechanism and kinetics of infrared laser ablation of poly(vinylidene fluoride) (PVDF) in vacuum have been investigated to understand how this can be used as a polymer processing technology. The laser heats the surface and initiates decomposition of macromolecules in the molten polymer layer which rapidly leads to production of an ablative flow of polymer decomposition products. There is only a short induction period of up to 2 s before ablation begins. After the initial period, the rate of mass loss increases linearly with the time of laser exposure. Spherical particles with an average diameter of about 100 nm are formed on the surface of the powder coating obtained by laser ablation. Here, the particle distribution ranges from 50 nm to 300 nm. The main gaseous product of ablation is HF from dehydrofluorination. A second important ablation process is the formation of gaseous carbenes generated during secondary reactions. Proposed ablation reactions due to laser-induced thermal dehydrofluorination occur in two stages. In the first stage, a double bond appears in PVDF due to direct loss of HF. Subsequent detachment of HF leads to the appearance of both triple bonds and cumulene bonds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct reuse of graphite and lithium nickel manganese cobalt oxide (NMC) recovered from ultrafast-laser ablation debris in Li-ion battery electrodes

Here we demonstrate that debris collected from the ultrafast-laser ablation of graphite anodes can be directly reused in a lithium-ion battery with little to no negative effects on electrochemical performance. Further, we show that while post-ablation NMC (LiNi 0.33 Mn 0.33 Co 0.33 O) cathode debris will require additional processing before being incorporated into an electrode, its critical materials (nickel, manganese, and cobalt) are not lost during ablation and can be recovered for recycling. Pre- and post-ablation materials are characterized with a suite of diagnostics, including SEM, TEM, X-ray CT, EDS, and XRD, to study changes in material morphology, composition and crystal structure. Graphite exhibited little to no morphological or compositional changes and a slight annealing of its crystal structure. NMC underwent profound morphological and crystallographic changes, but retained its elemental composition. Finally, post-ablation materials were re-manufactured into electrodes and cycled vs lithium metal. Graphite showed equal or better capacity and Coulombic efficiency compared to pre-ablation electrodes, while the post-ablation NMC exhibited severely reduced electrochemical performance. Furthermore, we discuss the outlook for application of this work to advanced manufacturing lines that produce next-generation, laser-patterned electrodes.

25 ENERGY STORAGE↗

A plasma model combined with an improved two-temperature equation for ultrafast laser ablation of dielectrics

It remains a big challenge to theoretically predict the material removal mechanism in femtosecond laser ablation. To bypass this unresolved problem, many calculations of femtosecond laser ablation of nonmetals have been based on the free electron density distribution without the actual consideration of the phase change mechanism. However, this widely used key assumption needs further theoretical and experimental confirmation. By combining the plasma model and improved two-temperature model developed by the authors, this study focuses on investigating ablation threshold fluence, depth, and shape during femtosecond laser ablation of dielectrics through nonthermal processes (the Coulomb explosion and electrostatic ablation). The predicted ablation depths and shapes in fused silica, by using (1) the plasma model only and (2) the plasma model plus the two-temperature equation, are both in agreement with published experimental data. The widely used assumptions for threshold fluence, ablation depth, and shape in the plasma model based on free electron density are validated by the comparison study and experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗