Search NASA⌕ Search

SEARCH · Search NASA

Results for “abnormality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Microstructure evolution during binder jet additive manufacturing of H13 tool steel

H13 is one of the most used tool steels for both hot and cold work tooling applications. Binder jet additive manufacturing offers the potential to deposit complex tools at scale due to larger powder bed sizes and faster deposition rates. However, to date there is no published literature on the sintering of H13 to full densification. Here, we discuss the pressureless sintering of binder jet AM H13 steel to full densification via supersolidus liquid phase sintering (SLPS) while presenting appropriate process windows (1360 °C – 1380 °C) for densification without distortion. The process windows have been rationalized based on thermodynamic calculations of liquid volume fractions with temperature. We show that higher binder saturation results in higher carbon retention and subsequently early liquid formation that can initiate the sintering process at lower temperatures. We report abnormal grain growth during sintering and found that the solidification phase transformations play a critical role on microstructural evolution and must be considered to accurately model the kinetics of SLPS.

36 MATERIALS SCIENCE↗

Emergency department overcrowding and its associated factors at HARME medical emergency center in Eastern Ethiopia

Introduction: Emergency department (ED) overcrowding has become a significant concern as it can lead to compromised patient care in emergency settings. Various tools have been used to evaluate overcrowding in ED. However, there is a lack of data regarding this issue in resource-limited countries, including Ethiopia. This study aimed to validate NEDOCS, assess level of ED overcrowding and identify associated factors at HARME Medical Emergency Center, located in Hiwot Fana Comprehensive Specialized Hospital, Harar, Ethiopia. Methods: A cross-sectional study was conducted at the HARME Medical Emergency Center, Hiwot Fana Comprehensive Specialized Hospital, involving a total of 899 patients during 120 sampling intervals. The area under the receiver operating characteristic curves (AUC) was calculated to evaluate the agreement between objective and subjective assessments of ED overcrowding. A multivariable logistic regression analysis was employed to identify factors associated with ED overcrowding and statistically significant association was declared using 95% confidence level and a p-value < 0.05. Results: The interrater agreement showed a strong correlation with a Cohen's kappa (κ) of 0.80. The National Emergency Department Overcrowding Study Score demonstrated a strong association with subjective assessments from residents and case team nurses, with an AUC of 0.81 and 0.79, respectively. According to residents' perceptions, ED were considered overcrowded 65.8% of the time. Factors significantly associated with ED overcrowding included waiting time for triage (AOR: 2.24; 95% CI: 1.54–3.27), working time (AOR: 2.23; 95% CI: 1.52–3.26), length of stay (AOR: 2.40; 95% CI: 1.27–4.54), saturation level (AOR: 2.35; 95% CI: 1.31–4.20), chronic illness (AOR: 2.19; 95% CI: 1.37–3.53), and abnormal pulse rate (AOR: 1.52; 95% CI: 1.06–2.16). Conclusion: The study revealed that ED were overcrowded approximately two-thirds of the time.

60 APPLIED LIFE SCIENCES↗

A physics-based parametric regression approach for feedwater pump system diagnosis

Here in this paper, we assessed the performance of a model-based approach for fault diagnosis of a nuclear power plant feedwater pump system. Physics-based models were constructed to monitor the performance of the system components. Plant data were used for the calibration of the models and subsequently in the diagnosis of abnormal events. We considered two real-time events representing scenarios of a pump fault and component performance degradation. The two events were correctly diagnosed, and the results demonstrated the high detection sensitivity of the physics-based models. Various sensor fault scenarios were simulated to show the capability of the approach to detect and uniquely identify sensor faults. Results for a scenario in which the plant operated in flexible power mode also showed that the diagnostic approach is insensitive to changes of operating conditions, which is one of the advantages of the model-based approach using physics-based models over purely data-driven approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A digital twin approach to system-level fault detection and diagnosis for improved equipment health monitoring

Automating the task of fault detection and diagnosis is crucial in the effort to reduce the operation and maintenance cost in the nuclear industry. This paper describes a physics-based approach for system-level diagnosis in thermal-hydraulic systems in nuclear power plants. The inclusion of physics information allows for the creation of virtual sensors, which provide improved fault diagnosis capability. The physics information also serves to better constrain diagnostic solutions to the physical domain. As a demonstration, various test cases for fault diagnosis in a high-pressure feedwater system were considered. The use of virtual sensors allows constructing performance models for two first-point feedwater heaters which would not have been possible otherwise due to the limited sensor set. Real-time plant data provided by a utility partner were used to assess the diagnostic approach. The detection of an abnormal event immediate after a plant startup pointed to faulty behaviors in the two first-point feedwater heaters. Further, this double-blind fault diagnosis was subsequently confirmed by the plant operator. In addition, several simulated sensor fault events demonstrated the capability of our algorithms in detecting and discriminating sensor faults.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Potential of deep learning methods to enhance satellite-based monitoring of nuclear power plants focusing on remote operation evaluations

The anticipated expansion of the nuclear industry and the deployment of new nuclear reactors (200 + GW of new nuclear capacity by 2050) require the development of monitoring systems that align with safety and security concerns, providing enhanced evaluation capabilities. A remote monitoring system using satellites and deep learning techniques was evaluated for its ability to detect anomalies and capture various features of nuclear reactors independently of the conditions on the ground. Satellite images of current operational and under-construction nuclear power plants were collected from Google Earth Pro as a surrogate database. Subsequently, five datasets were created from the collected images. Transfer learning technique was used for several classification tasks utilizing VGG16, ResNet50V2, Xception, DenseNet121, and MobileNetV2 pre-trained models. In the first task, the capability of the monitoring system to detect abnormal conditions or processes in a nuclear power plant was investigated. In the second task, the ability to capture operational features remotely was examined. As an example, for the purposes of this study, these features included classifying reactors based on type, power range, or onsite condition. Several evaluation metrics were used to compare the performance of the pre-trained models and the overall monitoring system. Here, the evaluation results demonstrated that deep learning techniques and pre-trained models applied to satellite images have the potential to facilitate further and expand capabilities in monitoring systems to assess plant operation details.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Programmable intrusion detection for distributed energy resources in cyber–physical networked microgrids

We present a programmable intrusion detection method is presented to identify the malicious attacks to distributed energy resources (DERs) in the cyber-physical networked microgrids. The proposed method injects small programmable signals into the system and uses the response to identify abnormal conditions. Because of the low or even zero inertia induced by integrations of DER power-electronic-interfaces, microgrids have very limited resilience capability; and thus, being sensitive to attacks. One microgrid's malfunction caused by attacks can easily propagate to its neighboring systems when several microgrids are connected, leading to catastrophic electricity supply failures. Through the presented method, malicious intrusions can be effectively detected, located, and defended for securing microgrids. Theoretical derivations are provided to define the programmable detection rules. The detection rule is easy and flexible to update, making it difficult for attack actors to gain the knowledge of the detection rules, in order to avoid being detected. Numerical results on a cyber-physical networked microgrids system show that the proposed method is effective and efficient in precisely locating intrusion attacks to the microgrids system.

42 ENGINEERING↗

Using discrete Bayesian networks for diagnosing and isolating cross-level faults in HVAC systems

Fault detection and diagnosis (FDD) technologies are critical to ensure satisfactory building performance, such as reducing energy wastes and negative impacts on occupant comfort and productivity. Existing FDD technologies mainly focus on component-level FDD solutions, which could lead to mis-diagnosis of cross-level faults in heating, ventilating, and air-conditioning (HVAC) systems. Cross-level faults are those faults that occur in one component or subsystem, but cause operational abnormalities in other components or subsystems, and result in a building level performance degradation. How to effectively diagnose the root cause of a cross-level fault is the focus of this study. Here, this paper presents a novel discrete Bayesian Network (DisBN)-based method for diagnosing cross-level faults in an HVAC system commonly used in commercial buildings. A two-level DisBN structure model is developed in this study. The parameters used in the DisBN model are obtained either from expert knowledge or through machine-learning strategies from normal system operation data. Meanwhile, the probability parameters are discretized to incorporate the uncertainties associated with typical expert knowledge. Thus, the developed DisBN method addresses the challenges many other BN based FDD methods face, i.e., the lack of fault data for BN parameter training. The developed DisBN represents causal relationships between a fault and its cross-level system impacts (i.e., fault symptoms or fault indicators) by considering how fault impacts propagate across different levels in an HVAC system. A weather and schedule information-based Pattern Matching (WPM) method is employed to automatically create WPM baseline data sets for each incoming real time snapshot data from the building systems. Consequently, BN inference and real-time diagnostics are achieved by comparing incoming snapshot data and the WPM baseline data set. The proposed method is evaluated using experimental fault data collected in a campus building. Fault diagnosis results demonstrate that the WPM-DisBN method is effective at locating the root causes of cross-level faults in an HVAC system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Expression of the Trichoderma reesei expansin-like protein, swollenin, in poplar results in biomass with improved sugar release by enzymatic hydrolysis

Ethanol production from lignocellulosic biomass has been considered an alternative to corn-based ethanol and fossil fuel. However, the secondary cell wall structure prevents efficient degradation of cellulose. Expression of cell wall degrading enzymes has been suggested as one solution to generate suitable feedstocks for lignocellulosic ethanol production. Swollenin (SWO), originating from Trichoderma reesei, disrupts cellulose structure with low-level hydrolytic activity to the glucan chain. Previously, characterization of T. reesei SWO has been carried out in multiple microorganisms and tobacco. This study heterologously overexpressed T. reesei SWO in hybrid poplar (Populus tremula × alba), a promising feedstock for biofuel production, under the control of either the constitutive Cauliflower Mosaic Virus 35S (CaMV 35S) promoter or the putative vascular tissue specific Subterranean Clover Stunt Virus S7 (SCSV) promoter. Transgenic poplar lines with high or moderate SWO expression level showed abnormal growth and reduced biomass production, along with increased glucose and reduced lignin contents. Increased cellulose crystallinity was observed in two transgenic events. This study also investigated the effect of in planta SWO expression on cellulose saccharification efficiency and found that transgenic events improved glucan conversion rates compared to wild type poplar. The results suggest SWO-overexpressing transgenic poplar lines could be a potential feedstock for ethanol production.

09 BIOMASS FUELS↗

PlasmoData.jl — A Julia framework for modeling and analyzing complex data as graphs

Datasets encountered in scientific and engineering applications appear in complex formats (e.g., images, multivariate time series, molecules, video, text strings, networks). Graph theory provides a unifying framework to model such datasets and enables the use of powerful tools that can help analyze, visualize, and extract value from data. In this work, we present PlasmoData.jl, an open-source, Julia framework that uses concepts of graph theory to facilitate the modeling and analysis of complex datasets. The core of our framework is a general data modeling abstraction, which we call a DataGraph. We show how the abstraction and software implementation can be used to represent diverse data objects as graphs and to enable the use of tools from topology, graph theory, and machine learning (e.g., graph neural networks) to conduct a variety of tasks. We illustrate the versatility of the framework by using real datasets: (i) an image classification problem using topological data analysis to extract features from the graph model to train machine learning models; (ii) a disease outbreak problem where we model multivariate time series as graphs to detect abnormal events; and (iii) a technology pathway analysis problem where we highlight how we can use graphs to navigate connectivity. Further, our discussion also highlights how PlasmoData.jl leverages native Julia capabilities to enable compact syntax, scalable computations, and interfaces with diverse packages. Overall, we show that the DataGraph abstraction and PlasmoData.jl Julia package are able to model data within graphs and enable useful analysis.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Characterizing Long COVID: Deep Phenotype of a Complex Condition

Background: Numerous publications describe the clinical manifestations of post-acute sequelae of SARS-CoV-2 (PASC or "long COVID"), but they are difficult to integrate because of heterogeneous methods and the lack of a standard for denoting the many phenotypic manifestations. Patient-led studies are of particular importance for understanding the natural history of COVID-19, but integration is hampered because they often use different terms to describe the same symptom or condition. This significant disparity in patient versus clinical characterization motivated the proposed ontological approach to specifying manifestations, which will improve capture and integration of future long COVID studies. Methods: The Human Phenotype Ontology (HPO) is a widely used standard for exchange and analysis of phenotypic abnormalities in human disease but has not yet been applied to the analysis of COVID-19. Funding: We identified 303 articles published before April 29, 2021, curated 59 relevant manuscripts that described clinical manifestations in 81 cohorts three weeks or more following acute COVID-19, and mapped 287 unique clinical findings to HPO terms. We present layperson synonyms and definitions that can be used to link patient self-report questionnaires to standard medical terminology. Long COVID clinical manifestations are not assessed consistently across studies, and most manifestations have been reported with a wide range of synonyms by different authors. Across at least 10 cohorts, authors reported 31 unique clinical features corresponding to HPO terms; the most commonly reported feature was Fatigue (median 45.1%) and the least commonly reported was Nausea (median 3.9%), but the reported percentages varied widely between studies. Interpretation: Translating long COVID manifestations into computable HPO terms will improve analysis, data capture, and classification of long COVID patients. If researchers, clinicians, and patients share a common language, then studies can be compared/pooled more effectively. Furthermore, mapping lay terminology to HPO will help patients assist clinicians and researchers in creating phenotypic characterizations that are computationally accessible, thereby improving the stratification, diagnosis, and treatment of long COVID.

60 APPLIED LIFE SCIENCES↗

Lower and upper threshold limit for artificial neural network based chilled and condenser water temperatures set-point control in a chilled water system

In this study, an ANN (artificial neural network) based real-time optimized control algorithm for a chilled water cooling system was developed and applied in an actual building to analyze its cooling energy saving effects through in-situ application and actual measurements. For this purpose, the cooling tower’s CndWT (condenser water temperature) and the chiller’s ChWT (chilled water temperature) were set as system control variables. To evaluate algorithm performance, the electric consumption and the COP (coefficient of performance) were compared and analyzed when ChWT and CndWTs were controlled conventionally and controlled based on the ANN. During the analysis, unexpected abnormal data was observed due to insufficient training data and limited consideration of OWBT (outdoor air wet-bulb temperature) when determining the CndWT set-point. Therefore, it is necessary to further build training data from a wider range of conditions and to set the lower limit of CndWT set-point to at least +3.6 °C above OWBT when the OWBT is higher than 23 °C, so that further energy savings can be achieved.

42 ENGINEERING↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unique impacts of strong and westward-extended western Pacific subtropical high on ozone pollution over eastern China

As a subtropical anticyclonic high-pressure system that typically forms over the northwestern Pacific Ocean in summer, the Western Pacific subtropical high (WPSH) affects meteorological conditions and ozone pollution in China. The relationship between maximum daily 8-h average ozone (MDA8 O 3 ) concentrations and the extremely strong and westward-extended WPSH occurred in 2022 is investigated using observations, reanalysis data and GEOS-Chem model simulations. The intensity of WPSH has a significant positive correlation with MDA8 O3 over southern China during July-August in 2022, with a correlation coefficient of +0.44, but the correlation is negative (–0.40) in northern China. During the strong WPSH days, MDA8 O 3 increased by 16.5µgm -3 (16.4% relative to July-August average) over southern China and decreased by 19.0µgm -3 (14.5%) in northern China compared to the weak WPSH days. The unique dipole pattern in the relationship between ozone levels and the WPSH in 2022 exhibited a contrast to that during 2015–2021. The difference is primarily due to the extremely strong WPSH intensity and its unusual westward expansion in 2022. In this case, an anomalous anticyclone at 500 hPa dominates over southern China, which creates conditions conducive for ozone formation and accumulation. The anticyclone weakened horizontal winds and reduced the dispersion of ozone, alongside a high temperature and low relative humidity, which favored the chemical production of ozone. In contrast, abnormal northerly winds enhanced ozone diffusion in northern China and the low temperature reduced ozone chemical production. Here, this study reveals the mechanism for the significant impact of strong and westward-extended WPSH on ozone concentrations over China, emphasizing the role of the WPSH location in modulating meteorology and ozone levels.

54 ENVIRONMENTAL SCIENCES↗

Incidence of chronic respiratory conditions among oil spill responders: Five years of follow-up in the Deepwater Horizon Oil Spill Coast Guard Cohort study

Background: Over ten years after the Deepwater Horizon (DWH) oil spill, our understanding of long term respiratory health risks associated with oil spill response exposures is limited. Here we conducted a prospective analysis in a cohort of U.S. Coast Guard personnel with universal military healthcare. Methods: For all active duty cohort members (N = 45,193) in the DWH Oil Spill Coast Guard Cohort Study we obtained medical encounter data from October 01, 2007 to September 30, 2015 (i.e., ~2.5 years pre-spill; ~5.5 years post-spill). We used Cox Proportional Hazards regressions to calculate adjusted hazard ratios (aHR), comparing risks for incident respiratory conditions/symptoms (2010–2015) for: responders vs. non-responders; responders reporting crude oil exposure, any inhalation of crude oil vapors, and being in the vicinity of burning crude oil versus responders without those exposures. We also evaluated self-reported crude oil and oil dispersant exposures, combined. Within-responder comparisons were adjusted for age, sex, and smoking. Results: While elevated aHRs for responder/non-responder comparisons were generally weak, within-responder comparisons showed stronger risks with exposure to crude oil. Notably, for responders reporting exposure to crude oil via inhalation, there were elevated risks for all sinusitis (aHR = 1.48; 95%CI, 1.06–2.06), unspecified chronic sinusitis (aHR = 1.55; 95%CI, 1.08–2.22), chronic obstructive pulmonary disease (COPD) and other allied conditions (aHR = 1.43; 95%CI, 1.00–2.06), and dyspnea and respiratory abnormalities (aHR = 1.29; 95%CI, 1.00–1.67); there was a suggestion of elevated risk for diseases classified as asthma and reactive airway diseases (aHR = 1.18; 95%CI, 0.98–1.41), including the specific condition, asthma (aHR = 1.35; 95%CI, 0.80–2.27), the symptom, shortness of breath (aHR = 1.50; 95%CI, 0.89–2.54), and the overall classification of chronic respiratory conditions (aHR = 1.18; 95%CI, 0.98–1.43). Exposure to both crude oil and dispersant was positively associated with elevated risk for shortness of breath (HR = 2.24; 95%CI, 1.09–4.64). Conclusions: Among active duty Coast Guard personnel, oil spill clean-up exposures were associated with moderately increased risk for longer term respiratory conditions.

54 ENVIRONMENTAL SCIENCES↗

Flow dynamics and heat transfer in simplified battery energy storage systems with heated battery modules

Large-scale energy storage systems (ESSs) composed of batteries show promise in addressing current energy challenges, but dissipation of generated heat is important. Here, this paper focuses on buoyant convective flows in simplified ESS battery racks. Natural convection is not generally the primary cooling strategy but can be important in abnormal scenarios where there is module overheat or potentially thermal runaway. We use computational fluid dynamics to investigate the flow dynamics and heat transfer mechanisms in a simplified parameterized rack design. Despite its simplicity, this configuration produces many of the relevant features expected in real ESSs without details of module geometry or hardware, allowing broad conclusions independent of manufacture-specific designs. We start by providing visualizations of the flowfield and measurements of entrainment, heat flux, and pressure. To characterize the dependence on the system parameters, we develop an integral-scale analysis of the average temperature equation to highlight the dominant source terms. We use results from this analysis to derive a steady network model composed of simple algebraic expressions to provide first-order predictions of entrainment through the rack. The network model leads to a linear scaling of the Reynolds number based on convective mass flux with respect to the Grashof number based on the heat source. We deduce empirical relationships that relate the heat exchanged between modules using a surface-averaged Nusselt number as a function of the local Reynolds and Rayleigh numbers. Lastly, we investigate how space between the modules and rack in the spanwise direction creates flow bypass, resulting in different flow pathways.

Battery thermal management↗

Propagation of elastic waves in a flexomagnetic solid

Flexomagnetism is the coupling between magnetism and strain gradients and is a technologically relevant phenomenon. We present a theory of elastic wave propagation in a linear elastic flexomagnetic material with microstructure and strain gradient elastic interactions. The expressions of frequency, phase velocity, and group velocity of longitudinal and transverse waves are derived and are shown to depend on the flexomagnetic coefficient and microstructure. We also show that the effect of flexomagnetism and microstructure can lead to some interesting phenomena in wave propagation, which are not observed in classical linear elasticity theory of waves. Specifically, in contrast to classical linear elastic materials, where wave propagation is non-dispersive, flexomagnetic materials with microstructure can exhibit both normal and abnormal dispersion. It is also noteworthy that, in flexomagnetic materials with gradient elasticity, the phase velocities of transverse waves can exceed those of longitudinal waves, which is atypical in classical elasticity. Furthermore, waves can also attenuate for a certain range of wavenumbers that depend on the flexomagnetic coefficient and microstructural parameters. Finally, we explore the possibility of waves exhibiting zero group velocity modes, where waves are non-propagating but have strong local energy confinement, negative group velocity modes, where the wave packet moves in the opposite direction to that of wave propagation, and the phenomenon of wave freezing, where a propagating wave stops in space without diffusing or spreading.

Ghosh, Swarnava [ORNL] (ORCID:0000000338005264)↗

An analysis of alcohol compression ignition strategies on different engine platforms

Strategies that enable ignition of the low cetane alcohol fuels (methanol and ethanol) include intake heating (direct or via hot residual trapping), increased compression ratio (CR), multi-injection strategies, ignition enhancers, and active prechambers. The literature consistently shows alcohol compression ignition (CI) is more efficient than diesel at high loads irrespective of ignition strategy but shows contradictory results at low loads. To understand this, this work combines data from four different engine platforms ranging from a displaced volume of 0.4 to 2.1 L/cyl. using different alcohol CI ignition strategies. Using modeling to support experimental analysis, alcohol-specific efficiency penalties are highlighted to inform alcohol combustion system development. The alcohols’ lower energy density means more fuel must be injected near top dead center to achieve a given load, increasing the relative penalty of sensible/latent heating. Pilot injections help reduce this penalty. Intake heating incurs both a heat transfer penalty and a thermodynamic penalty due to a reduced ratio of specific heats during compression. A strategy that combines elevated CR, large pilot injections, and ignition enhancers can avoid this penalty. Alternatively, a prechamber strategy can achieve this without changing the CR, nor needing ignition enhancers in the fuel. At low loads, diesel burns in a partially premixed mode characterized by high burn rates and low heat losses, reducing alcohol-specific combustion benefits. Alcohol CI on the light-duty platform showed abnormally high heat transfer over diesel compared to other platforms, favoring a more premixed/partially premixed strategy despite a combustion efficiency tradeoff.

33 ADVANCED PROPULSION SYSTEMS↗

Recent progress in the design of the K-DEMO divertor

The preliminary conceptual design of the Korean fusion demonstration reactor (K-DEMO) with a major radius of 6.8 m and the fusion power of 2200 MW has been studied since 2012. The overall configuration of the K-DEMO divetor system based on the ITER-like water-cooled tungsten technology is a double-null type symmetric divertor subdivided into 32 toroidal modules for the vertical maintenance. A detached divertor scenario with impurity seeding was considered as the primary approach for the power exhaust to reduce the peak heat flux lower than the engineering limit of 10 MW/m 2 . The power exhaust performance at the scrap off layer was estimated by using UEDGE-2D code, a two-dimensional fluid transport code for collisional edge plasma and neutral species like N, Ne, and Ar. Particle and heat flux on inboard and outboard divertor targets were calculated for the detached cased depending on parameters such as the impurity seeding rate, pumping rate, and the pedestal density. On the other hand, a magnetic solution like X-divertor, snowflake divertor, and super X-divertor to expand the plasma wet area was considered for K-DEMO since the detached divertor increasing a radiation fraction by impurity seeding might be able to be unstable. However, the extremely high current of poloidal coils was required more than the engineering limit, 20 MA, to form magnetic field lines for the alternative divertors. Based on the physical calculation of the edge plasma, engineering analyses were carried out to find out the thermal and structural reliability. The thermo-hydraulic analysis confirmed thermal stability, whether all comprising materials are operating within their allowable temperature windows when the case of the peak heat flux is set to 10 MW/m 2 on the outboard divertor target. The response surface optimization method derived two optimal design candidates employing two kinds of heat sink materials, respectively: the reduced activation ferritic martensitic (RAFM) steel and CuCrZr alloy. Additionally, the drawbacks and merits of the two materials were definite. The optimal design with applying RAFM steel was vulnerable to withstand thermal and mechanical loads since low thermal conductivity caused too thin thickness of the heat sink. On the other hand, the CuCrZr alloy has critical drawbacks in terms of activation and radioactive waste despite its high thermal conductivity. Meanwhile, preliminary electromagnetic (EM) analysis was carried out to estimate the EM loads caused by the abnormal behaviors of plasma since EM loads are one of the most critical external loads for designing a DEMO divertor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗