Search NASA⌕ Search

SEARCH · Search NASA

Results for “alarm systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Slow control and TDAQ systems installation and tests in the Mu2e experiment

The Mu2e experiment at Fermilab will attempt to detect a coherent neutrinoless conversion of a muon into an electron in the field of an aluminum nucleus, with a sensitivity that is 10,000 times greater than existing limits. The Mu2e trigger and data acquisition system (TDAQ) uses the otsdaqframework as its online Data Acquisition System (DAQ) solution. Developed at Fermilab, otsdaq integrates several components, such as an artdaq-based DAQ, an art-based event processing, and an EPICS-based detector control system (DCS), and provides a uniform multi-user interface toits components through a web browser. The data streams from the Mu2e tracker and calorimeter are handled by the artdaq-based DAQ and processed by a one-level software trigger implemented within the art framework. Events accepted by the trigger have their data combined, post-trigger, with the separately read-out data from the Mu2e Cosmic Ray Veto system. The foundation of Mu2e DCS, EPICS, an Experimental Physics and Industrial Control System, is an open-source platform for monitoring, controlling, alarming, and archiving. Over the last three years, a prototype ofthe TDAQ and DCS systems has been built and tested at Fermilab’s Feynman Computing Center.Currently, the production system installation is underway. At the end, this work presents a brief update on the installation of racks and DAQ hardware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Speed Control System for the 87,000 HP Wind Tunnel Drive

This paper describes the design, installation, and integrated systems tests for a new drive motor speed control system which was part of a recent rehab project for the NASA Lewis 8x6 Supersonic Wind Tunnel. The tunnel drive consists of three mechanically-coupled 29,000 HP wound rotor induction motors driving an axial flow compressor. Liquid rheostats are used to vary the impedance of the rotor circuits, thus varying the speed of the drive system. The new design utilizes a distributed digital control system with a dual touch screen CRT operator console to provide alarm monitoring, logging, and trending. The liquid rheostats are driven by brushtype servomotor systems with magnetostrictive linear displacement transducers used for position feedback. The new system achieved all goals for speed variations with load, motor load balance, and control of total power.

Becks, Edward A.↗

Predicting Kyasanur forest disease in resource-limited settings using event-based surveillance and transfer learning

In recent years, the reports of Kyasanur forest disease (KFD) breaking endemic barriers by spreading to new regions and crossing state boundaries is alarming. Effective disease surveillance and reporting systems are lacking for this emerging zoonosis, hence hindering control and prevention efforts. We compared time-series models using weather data with and without Event-Based Surveillance (EBS) information, i.e., news media reports and internet search trends, to predict monthly KFD cases in humans. We fitted Extreme Gradient Boosting (XGB) and Long Short-Term Memory models at the national and regional levels. We utilized the rich epidemiological data from endemic regions by applying Transfer Learning (TL) techniques to predict KFD cases in new outbreak regions where disease surveillance information was scarce. Overall, the inclusion of EBS data, in addition to the weather data, substantially increased the prediction performance across all models. The XGB method produced the best predictions at the national and regional levels. The TL techniques outperformed baseline models in predicting KFD in new outbreak regions. Novel sources of data and advanced machine-learning approaches, e.g., EBS and TL, show great potential towards increasing disease prediction capabilities in data-scarce scenarios and/or resource-limited settings, for better-informed decisions in the face of emerging zoonotic threats.

60 APPLIED LIFE SCIENCES↗

Substation Secondary Asset Health Monitoring and Management System (SSHM)

Electric Power Group, LLC (EPG) was awarded DOE OE0000850 to design, develop, and demonstrate a real-time software application for substation secondary equipment health monitoring and management at host utility American Electric Power (AEP), a cost share partner. This project addresses the need for monitoring substation equipment health and providing operators with tools to identify and take pre-emptive action to avoid catastrophic equipment failure. By monitoring synchrophasor data in real time, data anomalies that indicate potential asset failure can be detected and alerts can be sent to operators in time to take corrective actions. EPG developed two data driven algorithms to identify abnormal equipment signature patterns as well as a method using substation linear state estimation (SLSE). The software has been deployed on hardened PC’s and tested and validated for cost share partner AEP’s substations - 138kV and 765 kV. The SSHM software has been accepted by AEP and final demonstration of DOE - OE0000850 for AEP and DOE was successfully completed on March 17th, 2020. EPG developed the Substation Secondary Asset Health Monitoring (SSHM) Platform to analyze equipment failure signatures in PMU data and alert substation personnel when pre-emptive inspection, repairs and other actions are warranted to prevent potential catastrophic failures. This is the first system that automatically monitors the health of substation secondary assets and alerts users to emerging failures using synchrophasor measurements. SSHM uses high resolution PMU data from PTs, CTs, and CCVTs to analyze equipment signatures and identify anomalies that are precursor indicators of potential equipment failure. When an anomaly is detected, there is a likelihood of potential failure of monitored equipment, the system alerts the user with visual alarms including alarm trend charts and indicator lights on a oneline diagram of the substation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A multisensor system for airborne surveillance of oil pollution

The U.S. Coast Guard is developing a prototype airborne oil surveillance system for use in its Marine Environmental Protection Program. The prototype system utilizes an X-band side-looking radar, a 37-GHz imaging microwave radiometer, a multichannel line scanner, and a multispectral low light level system. The system is geared to detecting and mapping oil spills and potential pollution violators anywhere within a 25 nmi range of the aircraft flight track under all but extreme weather conditions. The system provides for false target discrimination and maximum identification of spilled materials. The system also provides an automated detection alarm, as well as a color display to achieve maximum coupling between the sensor data and the equipment operator.

Edgerton, A. T.↗

A tactile-output paging communication system for the deaf-blind

A radio frequency paging communication system that has coded vibrotactile outputs suitable for use by deaf-blind people was developed. In concept, the system consists of a base station transmitting and receiving unit and many on-body transmitting and receiving units. The completed system has seven operating modes: fire alarm; time signal; repeated single character Morse code; manual Morse code; emergency aid request; operational status test; and message acknowledge. The on-body units can be addressed in three ways: all units; a group of units; or an individual unit. All the functions developed were integrated into a single package that can be worn on the user's wrist. The control portion of the on-body unit is implemented by a microcomputer. The microcomputer is packaged in a custom-designed hybrid circuit to reduce its physical size.

Baer, J. A.↗

New advances in non-dispersive IR technology for CO2 detection

This paper discusses new technology developments in CO2 detection using Non-Dispersive Infrared (NDIR) techniques. The method described has successfully been used in various applications and environments. It has exhibited extremely reliable long-term stability without the need of routine calibration. The analysis employs a dual wavelength, differential detection approach with compensating circuitry for component aging and dirt accumulation on optical surfaces. The instrument fails 'safe' and provides the operator with a 'fault' alarm in the event of a system failure. The NDIR analyzer described has been adapted to NASA Space Station requirements.

Small, John W.↗

Past experience Skylab mission

The design of the Skylab missions, 1973 to 1974, was intended to exclude any direct handling of hazardous, toxic, or reactive materials. The materials processing facility and multipurpose furnace provided a contained environment for conducting metals melting, brazing, sphere forming, and crystal growth experiments. At the end of the third mission, following the completion of all other experiments, the materials processing facility was used for a series of flammability experiments. The flammability tests were done last because of the contamination expected from the burning of the materials within the facility. The flammability tests demonstrated a number of peculiar effects that have implications for future design (fire detection, location, and suppression/control). Although the results of the flammability tests contain lessons appropriate to planning, a number of events during the flight illustrate situations or conditions that pose considerations beyond the commonly accepted range of concern for safety-related matters. This presentation includes a discussion of: Skylab flammability studies and the implications for fire suppression/control; false fire alarms and the Skylab fire detection system; space environmental effects on materials that are normally benign; spills/release of contaminants; the detrimental effect that the release of non-hazardous materials have on detection systems; and the problem of locating sources/originating point of hazards.

Pogue, William↗

Virtual acoustics displays

The real time acoustic display capabilities are described which were developed for the Virtual Environment Workstation (VIEW) Project at NASA-Ames. The acoustic display is capable of generating localized acoustic cues in real time over headphones. An auditory symbology, a related collection of representational auditory 'objects' or 'icons', can be designed using ACE (Auditory Cue Editor), which links both discrete and continuously varying acoustic parameters with information or events in the display. During a given display scenario, the symbology can be dynamically coordinated in real time with 3-D visual objects, speech, and gestural displays. The types of displays feasible with the system range from simple warnings and alarms to the acoustic representation of multidimensional data or events.

Wenzel, Elizabeth M.↗

Detecting Faults By Use Of Hidden Markov Models

Frequency of false alarms reduced. Faults in complicated dynamic system (e.g., antenna-aiming system, telecommunication network, or human heart) detected automatically by method of automated, continuous monitoring. Obtains time-series data by sampling multiple sensor outputs at discrete intervals of t and processes data via algorithm determining whether system in normal or faulty state. Algorithm implements, among other things, hidden first-order temporal Markov model of states of system. Mathematical model of dynamics of system not needed. Present method is "prior" method mentioned in "Improved Hidden-Markov-Model Method of Detecting Faults" (NPO-18982).

Smyth, Padhraic J.↗

Design for Vibration Monitoring: A Methodology for Reliable and Cost-Effective Vibration Monitoring

The purpose of health monitoring systems is to detect failures or defects for increased safety and performance and to provide on-condition maintenance with reduced costs. The problems associated with health monitoring systems include high rates of false alarms and missed failures, which make monitoring an unreliable and costly task. The reason for this is that unaccounted variations invalidate signal modeling assumptions. Our approach was to focus on vibration monitoring of rotating components. We analyzed baseline signals to determine statistical variations, identify and model factors that influence vibrations (pre-production vs. post-production variations), determine hit and false alarm rates with baseline flight data, model and predict effects of defects and variations on vibrations, and develop algorithms and metrics for failure and anomaly detection in the presence of variations.

Tumer, Irem Y.↗

Platform for Automated Anomaly Detection in the Mercury Process System at the Target System in the Spallation Neutron Source

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory accelerates proton beams, which are directed toward a mercury target to generate the world’s most intense neutron beams via spallation. The target system consists of several interconnected subsystems and accounts for a major share of the facility’s overall downtime. Early detection of anomalies in the target system response can thus provide the possibility of taking corrective actions to reduce downtime. Accelerator facilities have largely focused on the beam side for data-driven fault prognostics. On the target side, SNS relies on operational shift technicians (OSTs), who respond to alarms and manually flag anomalies onto the System Tracking and Reliability (STAR) platform. This paper presents one of the first studies of using machine learning (ML) to automate anomaly detection in the target system. The study focused on the mercury process system as the first use case and employed reconstruction-based anomaly detection on minutely sampled time series signals. The pipeline was integrated into the STAR platform to autonomously rank and flag anomalies every week. The STAR platform provides a user interface for the OSTs to evaluate the flagged anomalies, thereby incorporating human feedback.

Anomaly detection↗

Summer 1988 TDWR microburst analysis

The Terminal Doppler Weather Radar (TDWR) testbed system was operated during the months of July to August 1988 in a live operational demonstration providing microburst (and related weather hazard) protection to the Stapleton International Airport in Denver, CO. During this time period, the performance of the detection system was carefully monitored in an effort to determine the reliability of the system. Initial performance analysis indicates that the microburst detection component of TDWR satisfies the basic performance goals of 90 percent probability of detection and 10 percent probability of false alarm. An in-depth study of the system performance, based on analysis of both dual-Doppler radar observations and surface mesonet measurements, is in progress to provide a detailed understanding of the observability of microbursts by the radar, the ability of the algorithms to detect microburst observed by the radar, and the timeliness and accuracy of the microburst alarms provided to operational users.

Merritt, Mark W.↗

Rocket Engine Health Management: Early Definition of Critical Flight Measurements

The NASA led Space Launch Initiative (SLI) program has established key requirements related to safety, reliability, launch availability and operations cost to be met by the next generation of reusable launch vehicles. Key to meeting these requirements will be an integrated vehicle health management ( M) system that includes sensors, harnesses, software, memory, and processors. Such a system must be integrated across all the vehicle subsystems and meet component, subsystem, and system requirements relative to fault detection, fault isolation, and false alarm rate. The purpose of this activity is to evolve techniques for defining critical flight engine system measurements-early within the definition of an engine health management system (EHMS). Two approaches, performance-based and failure mode-based, are integrated to provide a proposed set of measurements to be collected. This integrated approach is applied to MSFC s MC-1 engine. Early identification of measurements supports early identification of candidate sensor systems whose design and impacts to the engine components must be considered in engine design.

Christenson, Rick L.↗

Operational Focused Data Analytics for Optimizing Radiation Portal Monitor-Based Nuclear Smuggling Detection Systems at Global Ports of Entry

The National Nuclear Security Administration’s Office of Nuclear Smuggling Detection and Deterrence has deployed a fleet of radiation portal monitors (RPMs) across the world at global ports of entry including seaports, airports, and land border crossings. These RPMs are integrated into radiation detection systems (RDS) that also include fixed cameras, optical character recognition (OCR) systems, primary scanning systems (e.g., X-ray or gamma-ray), and secondary scanning systems (e.g., spectroscopic radiation portal monitors, portable radiation detection systems). The data from these sensing technologies is collected at the Central Alarm Station (CAS) where servers and computers reside to control and operate the system. Operators utilize the data collected by the CAS and declared cargo information to make decisions on how to respond to an alarm.This work explores the use of CAS-located data, looking at both the sensor data streams and operator inputs, to perform analysis which supports customs and border protection agencies to improve training capability and operational effectiveness. We focus on analyzing site level effectiveness and behavior by rolling up CAS-located data collected from individual occurrences. To-date, more than 15 sites (e.g., seaports, airports, border crossings) have been analyzed in this manner with the goal of understanding system operations to verify effectiveness and recommend potential improvements. This work first aims to provide background information on relevant CAS-located data sources and our current operational system analytics process including example results. After summarizing our current analytic techniques, we discuss how the future data analytics systems can provide key benefits to improving operational performance while minimizing the burden these detection systems place on operators.

Kuhn, Michael↗

Smart connected worker edge platform for smart manufacturing: Part 2—Implementation and on‐site deployment case study

Abstract In this paper, we describe specific deployments of the Smart Connected Worker (SCW) Edge Platform for Smart Manufacturing through implementation of four instructive real‐world use cases that illustrate the role of people in a Smart Manufacturing paradigm through which affordable, scalable, accessible, and portable (ASAP) information technology (IT) acquires and contextualizes data into information for transmission to operation technologies (OT). For case one, the platform captures the relationships between energy consumption and human workflows for improved energy productivity while workers interact with machines during semiconductor manufacturing. The platform utilizes human cognition to identify anomalous machine behavior for root cause analysis of system faults via neural network (NN) that recognize alarm postures of workers with cameras. For case two, a smart assembly line is demonstrated for state monitoring and fault detection. Machine learning (ML) models are used to recognize system states and identify fault scenarios with human intervention. For case three, the platform monitors human–machine interactions to classify manufacturing machine states for proper operations and energy productivity. Internal energy states of individual or collections of manufacturing equipment are determined via NN based algorithms that disaggregate signals associated with smart metering typically deployed at manufacturing facilities. These methods predict the real time energy profile of each machine from the total energy profile of a manufacturing site. For case four, a software defined sensor system built with scientific workflow engines is demonstrated for contextualizing data from laser surface refraction for characterization, and diagnostics in the processing of additively manufactured titanium alloy.

Donovan, Richard P.↗

Innovative PLC Design for Optimized Potable Water Managment

My project here at Idaho National Laboratory (INL) was to work on Potable Water PLC Design (Programmable Logic Controllers). I was tasked in making a new panel design for the PLC system that will be moved from TRA BLDG 696 to TRA BLDG 608. This design needed to be updated since the old PLC system being about 20 years old. The manufacturer of the MicroLogix 1200 life expectancy showed it to be 10-20 years, and the system was discontinued in 2017. The new system we implemented was called CompactLogix Controller 5380, along with a new 24 VDC/10 Amp Power Supply. I made a design using Microsoft Visio, with the new material. But we needed to add it onto an Aluminum Panel that the system will be mounted onto, we need Unistrut’s for the aluminum panel to be mounted to. Some of the material we will still be using, like the R1 Alarm Relay, will be moving with the PLC system. The rest of the material will be new supplies that need to be updated systems, which the site is waiting for to complete the PLC system.

47 - OTHER INSTRUMENTATION↗

Microprocessor-based multichannel flutter monitor using dynamic strain gage signals

Two microprocessor-based multichannel monitors for monitoring strain gage signals during aerodynamic instability (flutter) testing in production type turbojet engines were described. One system monitors strain gage signals in the time domain and gives an output indication whenever the signal amplitude of any gage exceeds a pre-set alarm or abort level for that particular gage. The second system monitors the strain gage signals in the frequency domain and therefore is able to use both the amplitude and frequency information. Thus, an alarm signal is given whenever the spectral content of the strain gage signal exceeds, at any point, its corresponding amplitude vs. frequency limit profiles. Each system design is described with details on design trade-offs, hardware, software, and operating experience.

Smalley, R. R.↗