Search NASA⌕ Search

SEARCH · Search NASA

Results for “arcjets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

High power arcjet

The activities of the High Power Arcjet Project (HIPARC) from August 1990 to January 1991 are discussed. In this period the HIPARC thruster was ignited for the first time. Power levels up to 140 kW with a mass flow rate of 300 mg/s hydrogen were reached. Specific impulse values of more than 1300 s were shown to be possible. Tests were performed with the baseline thruster version only, which has a 6 mm throat diameter and a conical nozzle with a 20 degree half angle. Measurement data summing up all tests carried out until now is included. All measuring methods are described, including a check on possible error sources.

Goelz, T. M.↗

Investigation of the Arcjet near Field Plume Using Electrostatic Probes

The near field plume of a 1 kW class arcjet thruster was investigated using electrostatic probes of various geometries. The electron number densities and temperatures were determined in a simulated hydrazine plume at axial distances between 3 cm (1.2 in.) and 15 cm (5.9 in.) and radial distances extending to 10 cm (3.9 in.) off centerline. Values of electron number densities obtained using cylindrical and spherical probes of different geometries agreed very well. The electron density on centerline followed a source flow approximation for axial distances as near as 3 cm (1.2 in.) from the nozzle exit plane. The model agreed well with previously obtained data in the far field. The effects of propellant mass flow rate and input power level were also studied. Cylindrical probes were used to obtain ion streamlines by changing the probe orientation with respect to the flow. The effects of electrical configuration on the plasma characteristics of the plume were also investigated by using a segmented anode/nozzle thruster. The results showed that the electrical configuration in the nozzle affected the distribution of electrons in the plume.

Sankovic, John M.↗

Nonequilibrium in a low power arcjet nozzle

Emission spectroscopy measurements were made of the plasma flow inside the nozzle of a 1 kW class arcjet thruster. The thruster propellant was a hydrogen-nitrogen mixture used to simulate fully decomposed hydrazine. The 0.25 mm diameter holes were drilled into the diverging section of the tungsten thruster nozzle to provide optical access to the internal flow. Atomic electron excitation, vibrational, and rotational temperatures were determined for the expanding plasma using relative line intensity techniques. The atomic excitation temperatures decreased from 18,000K at a location 3 mm downstream of the constrictor to 9,000K at a location 9 mm from the constrictor, while the molecular vibrational and rotational temperatures decreased from 6,500K to 2,500K and from 8,000K to 3,000K, respectively, between the same locations. The electron density measured using hydrogen H line Stark broadening decreased from about 10(exp 15) cm(-3) to about 2 times 10(exp 14) cm(-3) during the expansion. The results show that the plasma is highly nonequilibrium throughout the nozzle, with most relaxation times equal or exceeding the particle residence time.

Zube, Dieter M.↗

Electrode erosion in low power arcjet thrusters

Low power arcjet thrusters (0.5 to 3 kW) are currently being considered for North-South station keeping of geosynchronous communication satellites. The erosion mechanisms of cathodes in these thrusters are not well understood. The experimental set-up to produce a steady state electric arc in a gas flow is described and some preliminary theoretical results on cathode erosion are presented.

Ghosh, A.↗

Arcjet thermal characteristics

The performance of water-cooled and radiation cooled arcjet thrusters operating on both 1:2 nitrogen/hydrogen mixtures at 1 to 2 kW and on pure hydrogen at 1 to 4 kW are compared. To investigate the effects of test facility background pressure on performance, data were taken for both thruster operating on nitrogen/hydrogen mixtures at facility background pressures nominally at 0.20 Pa and 20 Pa. It is shown that increasing the background pressure decreased the thruster performance, and simple pressure area corrections alone could not account for observed degradation in performance.

Sankovic, John M.↗

Effect of current ripple on cathode erosion in 30 kWe class arcjets

An investigation was conducted to study the effect of current ripple on cathode erosion in 30 kWe class arcjets to determine the change in the cathode erosion rate for high (11 percent) and low (4 percent) current ripple. The measurements were conducted using a copper-tungsten cathode material to accelerate the cathode erosion process. It is shown that the high ripple erosion rate was initially higher than the low ripple erosion rate, but decreased asymptotically with time to a level less than half that of the low ripple value. Results suggest that high ripple extends the cathode lifetime for long duration operation, and improves arc stability by increasing the cathode attachment area.

Harris, William J.↗

Power electronics for low power arcjets

In anticipation of the needs of future light-weight low-power spacecraft, arcjet power electronics in the 100- to 400-W operating range were developed. Power topologies similar to those in the higher 2-kW and 5- to 30-kW power range were implemented, including a four-transistor bridge-switching circuit, current-mode pulse-width modulated control, and an output current averaging inductor with an integral pulse generation winding. Reduction of switching transients was accomplished using a low inductance power distribution network, and no passive snubber circuits were necessary for power switch protection. Phase shift control of the power bridge was accomplished using an improved pulse width modulation to phase shift converter circuit. These features, along with conservative magnetics designs, allowed power conversion efficiencies of greater than 92.5 percent to be achieved into resistive loads over the entire operating range of the converter.

Hamley, John A.↗

Nonequilibrium in a low power arcjet nozzle

Emission spectroscopy measurements were made of the plasma flow inside the nozzle of a 1-kW-class arcjet thruster. The thruster propellant was a hydrogen-nitrogen mixture used to simulate fully decomposed hydrazine. Atomic electron-excitation, vibrational, and rotational temperatures were determined for the expanding plasma using relative line intensity techniques. The atomic excitation temperature decreased from 18,000 K at a location 3 mm downstream of the constrictor to 9000 K at a location 9 mm from the constrictor, while the molecular vibrational and rotational temperatures decreased from 6500 K to 2500 K and from 8000 K to 3000 K, respectively, between the same locations. The electron density, measured using hydrogen H-beta line Stark broadening, decreased from about 10 to the 15th cu cm to about 2 x 10 to the 14th cu cm during the expansion. The results show that the plasma is highly nonequilibrium throughout the nozzle, with most relaxation times equal or exceeding the particle residence time.

Myers, Roger M.↗

High-power hydrogen arcjet performance

A hydrogen arcjet was operated at power levels ranging from 5 to 30 kW with three different nozzle geometries. Test results using all three nozzle geometries are reported and include variations of specific impulse with flow rate, and thrust with power. Geometric variables investigated included constrictor diameter, length, and diverging exit angle. The nozzle with a constrictor diameter of 1.78 mm and divergence angle of 20 deg was found to give the highest performance. A specific impulse of 1460 s was attained with this nozzle at a thrust efficiency of 29.8 percent. The best efficiency measured was 34.4 percent at a specific impulse of 1045 s. Post test examination of the cathode showed erosion after 28 hours of operation to be small, and limited to the conical tip where steady state arc attachment occurred. Each nozzle was tested to destruction.

Haag, Thomas W.↗

Arcjet thermal characteristics

The performance of water-cooled and radiation-cooled arcjet thrusters operating on both 1:2 nitrogen/hydrogen mixtures at 1-2 kW and on pure hydrogen at 1-4 kW are compared. To investigate the effects of test facility background pressure on performance, data were taken for both thrusters operating on hydrogen/nitrogen mixtures at facility background pressures nominally at 0.20 Pa and 20 Pa. It is shown that increasing the background pressure decreased the thruster performance, and simple pressure area corrections alone could not account for the observed degradation in performance.

Sankovic, John M.↗

High-power hydrogen arcjet performance

A hydrogen arcjet was operated at power levels ranging from 5 to 30 kW with three different nozzle geometries. Test results using all three nozzle geometries are reported and include variations of specific impulse with flow rate, and thrust with power. Geometric variables investigated included constrictor diameter, length, and diverging exit angle. The nozzle with a constrictor diameter of 1.78 mm and divergence angle of 20 degrees was found to give the highest performance. A specific impulse of 1460 s was attained with this nozzle at a thrust efficiency of 29.8 percent. The best efficiency measured was 34.4 percent at a specific impulse of 1045 s. Post test examination of the cathode showed erosion after 28 hours of operation to be small, and limited to the conical tip where steady state arc attachment occurred. Each nozzle was tested to destruction.

Haag, Thomas W.↗

High power arcjet

In this period a new mass flow controller was brought into the gas supply system, so that the upper limit for the mass flow rate could be increased up to 500 mg/s with hydrogen. A maximum specific impulse of 1500 s could be achieved with the high powered arcjet (HIPARC) at an efficiency of slightly better than 20 percent. Different nozzle throat diameters had been tested. The 100 kilo-watt input power limit was reached with the 4 mm nozzle throat diameter at a mass flow rate of 400 mg/s. Tests were carried out with different cathode gaps and with three different cathodes. In addition measurements of pressure and gas temperature were taken in the feed line in order to determine the pressure drop in the propellant injectors.

Goelz, T. M.↗

Techniques for Spectroscopic Measurements in an Arcjet Nozzle

A successful attempt has been made to gain optical access to the inside of an arcjet nozzle without changing internal thruster design or affecting performance characteristics. Both fiber optics and small open holes have been used for emission spectroscopy of a small, confined, high-temperature plasma source. The plasma was found to be in a highly nonequilibrium state, with electron excitation temperatures more than double the rotational or vibrational temperatures.

Zube, Dieter M.↗

Laser-induced fluorescence of atomic hydrogen in an arcjet thruster

A diagnostic has been developed to measure gas kinetic temperature and velocity in a 1 kW hydrogen fueled arcjet thruster. The technique is based on laser-induced fluorescence of the Balmer alpha transition (656 nm) in atomic hydrogen. A narrowband CW ring dye laser scans the excitation spectrum, permitting accurate determination of the atomic line shape and position. The velocity is inferred from the Doppler shift of the transition while the temperature is obtained from the shape. Near the exit plane, measured axial velocity varies between 4 and 14 km/s; measured radial velocity varies from 0 to 4 km/s. Temperatures were measured in the range from 1000 K near the edge of the plume to 5000 K at the centerline. Relevant broadening mechanisms are discussed.

Liebeskind, John G.↗

Preliminary investigation of a low power pulsed arcjet thruster

A type of pulsed arcjet is examined which operates with gaseous helium propellant at powers from 100 to 1500 W and pulse rats from 360 to 6000 pulses per second. During the pulse, peak power is 50 to 250 kW generating chamber pressures of 10 to 50 atmospheres. The high operating pressure substantially reduces ionization in the 2.5 mm diameter x 12.5 mm long capillary and lowers frozen flow losses in the nozzle. The thruster thermal efficiency, measured calorimetrically, is 43 percent at 440 W and 8 mg/sec helium mass flow rate. Thruster performance trends are predicted by a time-dependent lumped-parameter model which includes heat exchange between the propellant and the wall. The model substantially underpredicts the experimental thermal efficiency values. Alternative thruster configurations yielding significant improvements in thrust efficiency and specific impulse are discussed.

Taylor, Russell D.↗

Flow diagnostics of an arcjet using laser-induced fluorescence

A diagnostic has been developed to measure velocity and translational temperature in the plume of an arcjet thruster. Laser induced fluorescence with a narrowband CW laser is used to probe the Balmer alpha transition of excited atomic hydrogen. The velocity is determined from the Doppler shift of the fluorescence excitation spectrum while temperature is inferred from its shape. Analysis shows that while Doppler broadening is the only significant broadening mechanism, the fine structure of the transition must be accounted for. Near the exit plane, axial velocities vary from 4 to 14 km/s; radial velocities vary from 0 to 4 km/s; and swirl velocities are shown to be relatively small. Temperatures from 1000 to 5000 K indicate high dissociation fractions.

Liebeskind, John G.↗

Low-power arcjet test facility impacts

Performance characterizations of a flight-type 1.4 kW arcjet system were conducted. Performance and thruster temperature distributions were measured at thruster input power levels and propellant mass flow rates ranging from 1274 to 1370 W and from 3.2 x 10 exp -5 to 5.1 x 10 exp -5 kg/s, respectively. Specific impulses measured at the two facilities, at comparable test cell pressures, using gaseous hydrogen-nitrogen propellant mixtures agreed to within 1 percent over the range of operating conditions tested. The specific impulses measured using hydrazine propellant were higher than that for the cold hydrogen/nitrogen mixtures. Agreement between the hydrazine and gas mixture data was good, however, when the differences in propellant ethalpies at the thruster inlet were considered. Specific impulse showed a strong dependence on test facility pressure, and was 3 to 4 percent higher below 0.1 Pa than for test cell pressures above 5 Pa.

Morren, W. E.↗

Vacuum ultraviolet absorption in a hydrogen arcjet

Atomic absorption spectroscopy was utilized to measure the ground state atomic hydrogen number density in the plasma produced in a low power hydrogen arcjet. A microwave driven hydrogen plasma was used as the source of radiation resonant with the vacuum ultraviolet Lyman alpha transition. The suitability of this radiation source is discussed. The optical depth of this transition prevented measurements at locations where the ground state atomic hydrogen number density was larger than 3 x 10 exp 19/cu m. These results indicate that other single-photon optical diagnostic techniques are equally ineffective in locations of higher hydrogen number density unless the spectral line shape of the atomic hydrogen absorbers is known.

Manzella, David H.↗