Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Low-Noise Amplifiers and Superconducting Flex Circuits for Frequency Domain Multiplexed Readout of Detector Arrays

The next-generation ground-based cosmic microwave background (CMB) experimental program aims to provide definitive measurements of the early universe using telescopes configured with large focal plane arrays requiring ~100,000 detectors and associated readout amplifiers and interconnecting components that are currently unavailable commercially. We describe research to demonstrate the feasibility of developing low-noise cryogenic amplifiers based on series SQUID arrays that are suitable for frequency domain multiplexed readout of large numbers of CMB detectors, and the feasibility of developing robust superconducting flex cables that will simplify cryogenic systems integration for large CMB instruments. Two iterations of prototype series SQUID array amplifier designs were completed. The designs were optimized using modeling and simulation tools to meet the requirements for CMB detector readouts. Two fabrication runs were completed, and a large number of devices from each design iteration were tested and characterized at 4 K. We also completed the development of processes for the fabrication of prototype superconducting flex cables on 4" wafers. Samples were tested for strength and robustness, and to determine the critical current at 4 K as a function of trace width. The new generation of series SQUID array amplifier designs exhibit excellent performance characteristics – very smooth output characteristics that simplify tuning and operation, low input inductance, low current noise referred to the input, and low power dissipation that for the first time will enable these devices to be operated at the focal plane array stage of CMB instruments. The processes developed in Phase I to produce superconducting flex cables were used to complete the fabrication of a full wafer with several test and sample flex circuits. The 6-micron thick flex material is very strong with a breaking strength of several pounds for a 20-mm wide strip. Critical current density was reasonable and scaled with trace width as expected.

79 ASTRONOMY AND ASTROPHYSICS↗

Photoelectric array detectors for use at XUV wavelengths

The characteristics of photoelectric detector systems for use at visible-light, ultraviolet, and X-ray wavelengths are briefly reviewed in the context of the needs of the Spacelab solar-physics facilities. Photoelectric array detectors for use at XUV wavelengths between 90 and 1500 A are described, and their use in the ESA Grazing-Incidence Solar Telescope (GRIST) facility is discussed.

Timothy, J. G.↗

KALYPSO: Linear array detector for high-repetition rate and real-time beam diagnostics

Synchrotrons and modern FEL light sources operate with bunch repetition rates in the MHz range. The profile of the electron beam inside the accelerator can be characterized with indirect experimental techniques where linear array detectors are employed to measure the emitted synchrotron radiation or the spectrum of a near-IR laser. To improve the performance of modern beam diagnostics we have developed KALYPSO, a detector system operating with a continuous frame rate of up to 2.7 MHz. To facilitate the integration in different experiments, a modular architecture has been adopted. Different semiconductor micro-strip sensors can be connected to front-end ASICs to optimize the quantum efficiency at different photon energies, ranging from visible light up to near-IR. The front-end electronics are integrated within an heterogeneous DAQ consisting of FPGAs and GPUs, which allows scientists to implement real-time data processing algorithms. The current version of the detector is in operation at the KARA synchrotron light source and at the European XFEL. Finally, in this contribution we present the detector architecture, the performance results and the on-going technical developments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design of a hybrid Ge:Ga detector array

For potential applications in space infrared astronomy missions such as the Space Infrared Telescope Facility and the Large Deployable Reflector, integrated arrays of long-wavelength detectors are desired. The results of a feasibility study which developed a design for applying integrated array techniques to a long-wavelength (gallium-doped germanium) material to achieve spectral coverage between 30 and 200 microns are presented. An approach which builds up a two-dimensional array by stacking linear detector modules is presented. The spectral response of the Ge:Ga detectors is extended to 200 microns by application of uniaxial stress to the stack of modules. The detectors are assembled with 1 mm spacing between the elements. Multiplexed readout of each module is accomplished with integration sampling of a metal-oxide-semiconductor (MOS) switch chip. Aspects of the overall design, including the anticipated level of particle effects on the array in the space environment, a transparent electrode design for 200 microns response, estimates of optical crosstalk, and mechanical stress design calculations are included.

Parry, C. M.↗

On-board compensation for temporal changes in pushbroom scanner detector arrays

The design and operation of pushbroom and mechanical scanners are reviewed in order to determine differences in data preprocessing. Data preprocessing is categorized into spatial registration and radiometric corrections, as well as into systematic versus nonsystematic corrections. The category of nonsystematic radiometric errors due to temporal changes in detector array properties is emphasized as a subject of special interest and a challenging problem for onboard data preprocessing. Concepts for onboard compensation of temporal changes are presented. In particular one concept which uses dark current as an indicator of temperature change for determining gain and offset corrections is shown to have a number of advantages.

Jobson, D. J.↗

Characterization of an architecture for front-end pixel binning in an integrating pixel array detector

Optimization of an area detector involves compromises between various parameters like frame rate, read noise, dynamic range and pixel size. We have implemented and tested a novel front-end binning design in a photon-integrating hybrid pixel array detector using the MM-PAD- 2.0 pixel architecture. In this architecture, the pixels can be optionally binned in a 2 x 2 pixel configuration using a network of switches to selectively direct the output of 4 sensor pixels to a single amplifier input. Doing this allows a trade-off between frame rate and spatial resolution. Tests show that the binned pixels perform well, but with some degradation on performance as compared to an un-binned pixel. The increased parasitic input capacitance does reduce the signal collected per x-ray as well as increases the noise of the pixel. Here, the increase in noise is, however, less than the factor of 2 increase one would observe for binning in post-processing. Spatial scans across the binned pixels show that no measured signal intensity is lost at the inner binning unit boundaries. In the high flux regime, at a 2 x 2 pixel wide beam spot (FWHM) size, binned mode responds linearly up to a photon flux of 10 7 x-rays/s, and performs comparably with un-binned mode up to a photon flux of 10 8 x-rays/s. While this study demonstrates a proof of concept for front-end binning in integrating detectors, we also identify changes to this early-stage prototype which can further improve the performance of binning pixel structures.

47 OTHER INSTRUMENTATION↗

Evaluation of delivered monitor unit accuracy of gated step-and-shoot IMRT using a two-dimensional detector array

Purpose: To overcome the problem of organ motion in intensity-modulated radiation therapy (IMRT), gated IMRT is often used for the treatment of lung cancer. In this study, the authors investigated the accuracy of the delivered monitor units (MUs) from each segment during gated IMRT using a two-dimensional detector array for user-specific verification purpose. Methods: The authors planned a 6 MV photon, seven-port step-and-shoot lung IMRT delivery. The respiration signals for gated IMRT delivery were obtained from the one-dimensional moving phantom using the real-time position management (RPM) system (Varian Medical Systems, Palo Alto, CA). The beams were delivered using a Clinac iX (Varian Medical Systems, Palo Alto, CA) with the Millennium 120 MLC. The MatriXX (IBA Dosimetry GmbH, Germany) was validated through consistency and reproducibility tests as well as comparison with measurements from a Farmer-type ion chamber. The authors delivered beams with varying dose rates and duty cycles and analyzed the MatriXX data to evaluate MU delivery accuracy. Results: There was quite good agreement between the planned segment MUs and the MUs computed from the MatriXX within {+-}2% error. The beam-on times computed from the MatriXX data were almost identical for all cases, and they matched well with the RPM beam-on and beam-off signals. A slight difference was observed between them, but it was less than 40 ms. The gated IMRT delivery demonstrated an MU delivery accuracy that was equivalent to ungated IMRT, and the delivered MUs with a gating signal agreed with the planned MUs within {+-}0.5 MU regardless of dose rate and duty cycle. Conclusions: The authors can conclude that gated IMRT is able to deliver an accurate dose to a patient during a procedure. The authors believe that the methodology and results can be transferred to other vendors' devices, particularly those that do not provide MLC log data for a verification purpose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recent progress with multi-anode microchannel array detector systems

The construction and modes of operation of Multi-Anode Microchannel Arrays (MAMA's) are briefly reviewed. The MAMA detectors, which are a family of photoelectric, photon-counting array detectors being developed specifically for use in instruments on ground-based and space-borne telescopes, combine the high sensitivity and photometric stability of a conventional channel electron multiplier with a high-resolution imaging capability. The MAMA detectors feature low applied potential (less than 3 kV), high gain (greater than 10 to the 6th electrons/pulse), an absolute event timing accuracy of 100 ns or better, a very long count lifetime (greater than 2.5 x 10 to the 11th counts/sq mm), and a power consumption of less than 30 W for a complete system

Timothy, J. G.↗

Fabrication of Tunnel Junctions For Direct Detector Arrays With Single-Electron Transistor Readout Using Electron-Beam Lithography

This paper will describe the fabrication of small aluminum tunnel junctions for applications in astronomy. Antenna-coupled superconducting tunnel junctions with integrated single-electron transistor readout have the potential for photon-counting sensitivity at sub-millimeter wavelengths. The junctions for the detector and single-electron transistor can be made with electron-beam lithography and a standard self-aligned double-angle deposition process. However, high yield and uniformity of the junctions is required for large-format detector arrays. This paper will describe how measurement and modification of the sensitivity ratio in the resist bilayer was used to greatly improve the reliability of forming devices with uniform, sub-micron size, low-leakage junctions.

Stevenson, T. R.↗

Delta-Doped CCDs as Detector Arrays in Mass Spectrometers

In a conventional mass spectrometer, charged particles (ions) are dispersed through a magnetic sector onto an MCP at an output (focal) plane. In the MCP, the impinging charged particles excite electron cascades that afford signal gain. Electrons leaving the MCP can be read out by any of a variety of means; most commonly, they are post-accelerated onto a solid-state detector array, wherein the electron pulses are converted to photons, which, in turn, are converted to measurable electric-current pulses by photodetectors. Each step in the conversion from the impinging charged particles to the output 26 NASA Tech Briefs, February 2007 current pulses reduces spatial resolution and increases noise, thereby reducing the overall sensitivity and performance of the mass spectrometer. Hence, it would be preferable to make a direct measurement of the spatial distribution of charged particles impinging on the focal plane. The utility of delta-doped CCDs as detectors of charged particles was reported in two articles in NASA Tech Briefs, Vol. 22, No. 7 (July 1998): "Delta-Doped CCDs as Low-Energy-Particle Detectors" (NPO-20178) on page 48 and "Delta- Doped CCDs for Measuring Energies of Positive Ions" (NPO-20253) on page 50. In the present developmental miniature mass spectrometers, the above mentioned miniaturization and performance advantages contributed by the use of delta-doped CCDs are combined with the advantages afforded by the Mattauch-Herzog design. The Mattauch- Herzog design is a double-focusing spectrometer design involving an electric and a magnetic sector, where the ions of different masses are spatially separated along the focal plane of magnetic sector. A delta-doped CCD at the focal plane measures the signals of all the charged-particle species simultaneously at high sensitivity and high resolution, thereby nearly instantaneously providing a complete, high-quality mass spectrum. The simultaneous nature of the measurement of ions stands in contrast to that of a scanning mass spectrometer, in which abundances of different masses are measured at successive times.

Nikzad, Shouleh↗

Development of the detector array for photons, protons, and exotic residues

Accurate neutron capture predictions are needed in fundamental and applied science. Empirical models are constrained largely for stable nuclei, but predictions far from stability are needed. Neutron transfer in (d,p) reactions in inverse kinematics with rare isotope beams offer a means to access key aspects of the capture process. To this end, the detector array for photons, protons, and exotic residues (DAPPER) has been designed, built, tested, and used for measurement at Texas A&M University.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The high dynamic range pixel array detector (HDR-PAD): Concept and design

Experiments at storage ring light sources as well as at next-generation light sources increasingly require detectors capable of high dynamic range operation, combining low-noise detection of single photons with large pixel well depth. XFEL sources in particular provide pulse intensities sufficiently high that a purely photon-counting approach is impractical. The High Dynamic Range Pixel Array Detector (HDR-PAD) project aims to provide a dynamic range extending from single-photon sensitivity to 10{sup 6} photons/pixel in a single XFEL pulse while maintaining the ability to tolerate a sustained flux of 10{sup 11} ph/s/pixel at a storage ring source. Achieving these goals involves the development of fast pixel front-end electronics as well as, in the XFEL case, leveraging the delayed charge collection due to plasma effects in the sensor. A first prototype of essential electronic components of the HDR-PAD readout ASIC, exploring different options for the pixel front-end, has been fabricated. Here, the HDR-PAD concept and preliminary design will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Monolithic 2k x 2k LWIR HgCdTe Detector Array for Passively Cooled Space Missions

A 2K x 2K 10 µm cutoff HgCdTe array for background-limited space astronomy has been developed by Teledyne Imaging Sensors to specifications set by JPL, and demonstrated by University of Rochester at a focal plane temperature of 40K for the proposed JPL Near-Earth Object Camera (NEOCam) survey mission under the NASA Planetary Defense Coordination Office. We describe the detector performance for the first large format monolithic HgCdTe detector array tested, including the dark current, well depth, dark current vs. temperature, quantum efficiency, latent image performance, and read noise.

Pan, Jianmei↗

A Monolithic 2k x 2k LWIR HgCdTe Detector Array for Passively Cooled Space Missions

A 2K x 2K 10 µm cutoff HgCdTe array for background-limited space astronomy has been developed by Teledyne Imaging Sensors to specifications set by JPL, and demonstrated by University of Rochester at a focal plane temperature of 40K for the proposed JPL Near-Earth Object Camera (NEOCam) survey mission under the NASA Planetary Defense Coordination Office. We describe the detector performance for the first large format monolithic HgCdTe detector array tested, including the dark current, well depth, dark current vs. temperature, quantum efficiency, latent image performance, and read noise.

Pan, Jianmei↗

An airborne short wave infrared /SWIR/ pushbroom imaging system using a 64-element PbS detector array

Research evidence indicates that data in the short wave infrared (SWIR) spectral region will greatly improve the information content of remotely sensed data. Bands are required in the 1.55-1.75 micron and 2.08-2.35 micron spectral regions for a variety of agricultural and geological investigations. It is anticipated that future Landsat sensors will use pushbroom linear array technology to obtain high resolution, improved sensitivity and increased system reliability. To obtain early laboratory and field data, an airborne pushbroom image system has been designed for operation in the short wave infrared spectral region. The system uses a 64-element staggered PbS array and is operated at 195 K; the instrument has been designed to operate in an aircraft and will view a 19 degree swath width with a 5.8 mrad IFOV. The spectral bandwidth of each channel is .05 micron and the noise equivalent reflectivity in the order of .2% is provided. The requirements for more advanced detector arrays for use in future NASA spacecraft remote sensing instruments are also discussed.

Husain-Abidi, A. S.↗

Development of a Gamma-ray Burst Detector Based on the Silicon Drift Detector Array and Scintillators

We propose a gamma-ray burst (GRB) detector combining the silicon drift detector (SDD) array and scintillators with broadband X-ray and gamma-ray coverage (0.5-1000 keV or more), high energy resolution (2-10%) and high time resolution ({approx}{mu}s) in space. To realize such compact high-performance detector without photomultiplier tubes, we constructed proto-type model using KETEK SDD with a detection area of 1 cm{sup 2} and BGO crystal. The detector shows a very good performance. Obtained FWHM energy resolution was 191 eV at 5.9 keV in the SDD, while 6.5 % at 662 keV in the BGO at -30 deg. C. Evaluation of the 7 channel SDD array and development of analog ASIC for its readout are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced ACTPol Cryogenic Detector Arrays and Readout

Advanced ACTPol is a polarization-sensitive upgrade for the 6 m aperture Atacama Cosmology Telescope, adding new frequencies and increasing sensitivity over the previous ACTPol receiver. In 2016, Advanced ACTPol will begin to map approximately half the sky in five frequency bands (28-230 GHz). Its maps of primary and secondary cosmic microwave background anisotropies-imaged in intensity and polarization at few arcminute-scale resolution-will enable precision cosmological constraints and also awide array of cross-correlation science that probes the expansion history of the universe and the growth of structure via gravitational collapse. To accomplish these scientific goals, the AdvancedACTPol receiver will be a significant upgrade to the ACTPol receiver, including four new multichroic arrays of cryogenic, feedhorn-coupled AlMn transition edge sensor polarimeters (fabricated on 150 mm diameter wafers); a system of continuously rotating meta-material silicon half-wave plates; and a new multiplexing readout architecture which uses superconducting quantum interference devices and time division to achieve a 64-row multiplexing factor. Here we present the status and scientific goals of the Advanced ACTPol instrument, emphasizing the design and implementation of the AdvancedACTPol cryogenic detector arrays.

secondary cosmic microwave background anisotropies↗

Non-Destructive Plutonium Assay in Pyroprocessing Bulk Materials with a 3D Boron-Coated-Straw Detector Array

Assessment of plutonium content through all the processing steps is needed and is a challenging task. While several destructive assay methods have been developed for nuclear material accountability, a nondestructive assay (NDA) system for the assessment of plutonium in bulk materials is still needed. This system should withstand pyroprocessing harsh environments and have consistent sensitivity and accuracy despite different fuel form factors. We aim to enable the accurate assessment of the plutonium content of nuclear material during pyroprocessing to improve the separation process and enhance its proliferation resistance. We plan to achieve this goal by developing and demonstrating a new 3D boron-coated-straw neutron detector array (3D-BCSDA) with high efficiency and spatial resolution.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗