Search NASA⌕ Search

SEARCH · Search NASA

Results for “axial cracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The effect of lamination-induced stresses on fatigue damage development at internal flaws

The effects of stresses induced by the lamination of off-axis plies to O-deg lamina on the development of damage during the fatigue loading of the O-deg plies are discussed. The transverse normal stresses in the plane of the laminae and the laminate created by the laminating constraints when an axial force is applied to the laminate are calculated in terms of a differential Poisson ratio between the ply in question in the unconstrained and constrained states, and significant differences in the constraint environments of an unnotched specimen joined to plies of 45 and 90 deg inclination are noted which correspond to an increase in longitudinal splitting in the 90 deg case and a marked decrease in longitudinal splitting in the 45 deg case. If a notch is present, shear and crack-opening damage is found to be very effectively suppressed in 45-deg laminates, and less so in the 90-deg case. It is pointed out that whereas the 45-deg laminate represents the least damage situation, it does not have the greatest notched strength. It is concluded that an understanding and prediction of damage development in laminates requires knowledge of the stress fields caused by the lamination constraints.

Reifsnider, K. L.↗

Biaxial fatigue properties of thin-walled composite tubes

A testing method for obtaining fatigue and fracture data under biaxial loading and for negative R-ratios is described. Thin-walled tubes of 1-in. outer nominal diameter with a tapered grip section were tested in an Axial-Torsion Servohydraulic Testing Machine with a 463 Data Control Processor at frequencies below 10 Hz up to the 1-million cycle range. Room temperature, uniaxial constant amplitude fatigue data for high temperature cure graphite-epoxy material are presented at R = -0.4 for a (+, - 5 deg) fiber orientation. The fatigue curve is almost horizontal. Tests on (+, - 5 deg) 'SP-328' resulted in failures which predominantly originated in the grip section. Presently, a new specimen design is being tested intended to eliminate cracking in the grip section. Biaxial in-phase loading of (0/+, - 45) tubes of Fiberite graphite-epoxy resulted in much steeper fatigue curves than observed under uniaxial loading.

Krempl, E.↗

Thermal degradation of the tensile properties of undirectionally reinforced FP-AI203/EZ 33 magnesium composites

The effects of isothermal and cyclic exposure on the room temperature axial and transverse tensile strength and dynamic flexural modulus of 35 volume percent and 55 volume percent FP-Al2O3/EZ 33 magnesium composites were studied. The composite specimens were continuously heated in a sand bath maintained at 350 C for up to 150 hours or thermally cycled between 50 and 250 C or 50 and 350 C for up to 3000 cycles. Each thermal cycle lasted for a total of six minutes with a hold time of two minutes at the maximum temperature. Results indicate to significant loss in the room temperature axial tensile strength and dynamic flexural modulus of composites thermally cycled between 50 and 250 C or of composites isothermally heated at 350 C for up to 150 hours from the strength and modulus data for the untreated, as fabricated composites. In contrast, thermal cycling between 50 and 350 C caused considerable loss in both room temperature strength and modulus. Fractographic analysis and measurement of composite transverse strength and matrix hardness of thermally cycled and isothermally heated composites indicated matrix softening and fiber/matrix debonding due to void growth at the interface and matrix cracking as the likely causes of the strength and modulus loss behavior.

Bhatt, R. T.↗

Thermal degradation of the tensile properties of undirectionally reinforced FP-Al2O3/EZ 33 magnesium composites

The effects of isothermal and cyclic exposure on the room temperature axial and transverse tensile strength and dynamic flexural modulus of 35 volume percent and 55 volume percent FP-Al203/EZ 33 magnesium composites were studied. The composite specimens were continuously heated in a sand bath maintained at 350 C for up to 150 hours or thermally cycled between 50 and 250 C or 50 and 350 C for up to 3000 cycles. Each thermal cycle lasted for a total of six minutes with a hold time of two minutes at the maximum temperature. Results indicate no significant loss in the room temperature axial tensile strength and dynamic flexural modulus of composites thermally cycled between 50 and 250 C or of composites isothermally heated at 350 C for up to 150 hours from the strength and modulus data for the untreated, as-fabricated composites. In contrast, thermal cycling between 50 and 350 C caused considerable loss in both room temperature strength and modulus. Fractographic analysis and measurement of composite transverse strength and matrix hardness of thermally cycled and isothermally heated composites indicated matrix softening and fiber/matrix debonding due to void growth at the interface and matrix cracking as the likely causes of the strength and modulus loss behavior. Previously announced in STAR as N82-21260

Bhatt, R.T.↗

Advanced reinforcement systems for intermetallic applications

A 2-D axisymmetric model was employed to determine the magnitude of the radial, axial, and hoop stresses caused by the thermal expansion difference between fiber and matrix and which result from the fabrication temperature cycle. Finite element analysis was conducted for single fiber model systems based on SCS-6/Ti3Al+Nb and Al2O3/NiAl. The stress distribution due to the imposition of a graded intermediate layer for each system was determined and included variables of layer thickness and gradation in interlayer chemistry in order to vary the expansion gradient between fiber and matrix. Thermal cycling tests were conducted on sputter coated SCS-6 fibers selectively coated with Ti3Al+Nb, with and without an intermediate layer. Cracking of the Ti3Al+Nb layers was prevented by an interlayer based on Ti-TiN-Ti. The interlayer thickness appeared critical to its efficiency. Similarly, for the case of Al2O3/NiAl, an intermediate layer consisting of a Ni bond coat on the sapphire fiber followed by a graded Al2O3-NiAl layer did not crack when given a thermal excursion to 1100 C and then cooled to room temperature. Acoustic emission tests on single fiber specimens were unsuccessful in detecting load drops associated with the successive fracture of the fiber. For the SCS-6/Ti3Al system this was the result of several factors which included the matrix/fiber ratio and poor bonding of the matrix and fiber. In the case of the Al2O3/NiAl system brittle failure of the NiAl matrix precluded fiber breakdown during tensile loading.

Merrick, Howard F.↗

Results of inphase axial-torsional fatigue experiments on 304 stainless steel

A series of axial-torsional, inphase, strain-controlled, low-cycle fatigue tests were performed at room temperature on tubular specimens of 304 stainless steel. The program was conducted in cooperation with the task group on multiaxial fatigue research of ASTM committee E-09. The objective was to quantify the variability in multiaxial test results among several laboratories. Only included is data which was generated at the NASA Lewis Research Center's High Temperature Fatigue and Structures Laboratory. The experimental equipment and procedures used are described. The tubular specimens were polished on the outer surface to aid in the use of a cellulose film surface replication technique for crack detection. However, cracking initiated predominantly on the internal surface for all specimens. Honing of the bore of the tubular specimens lessened but did not entirely eliminate this problem. The observed fatigue lives are compared with lives calculated from three multiaxial life models. Constants for the life prediction models were obtained from uniaxial and torsional tests performed on the same heat of material. The observed fatigue lives agreed with calculated lives to within a factor of two for all but one of the life prediction models.

Bonacuse, Peter J.↗

Computational Implementation of a Thermodynamically Based Work Potential Model For Progressive Microdamage and Transverse Cracking in Fiber-Reinforced Laminates

A continuum-level, dual internal state variable, thermodynamically based, work potential model, Schapery Theory, is used capture the effects of two matrix damage mechanisms in a fiber-reinforced laminated composite: microdamage and transverse cracking. Matrix microdamage accrues primarily in the form of shear microcracks between the fibers of the composite. Whereas, larger transverse matrix cracks typically span the thickness of a lamina and run parallel to the fibers. Schapery Theory uses the energy potential required to advance structural changes, associated with the damage mechanisms, to govern damage growth through a set of internal state variables. These state variables are used to quantify the stiffness degradation resulting from damage growth. The transverse and shear stiffness of the lamina are related to the internal state variables through a set of measurable damage functions. Additionally, the damage variables for a given strain state can be calculated from a set of evolution equations. These evolution equations and damage functions are implemented into the finite element method and used to govern the constitutive response of the material points in the model. Additionally, an axial failure criterion is included in the model. The response of a center-notched, buffer strip-stiffened panel subjected to uniaxial tension is investigated and results are compared to experiment.

Pineda, Evan J.↗

Fatigue behavior of SiC reinforced Ti/6Al-4V/ at 650 C

Axial, low cycle fatigue properties of 25 and 44 fiber vol pct SiC/Ti(6Al-4V) composites, measured at 650 C, were compared with the fatigue properties of unreinforced Ti(6Al-4V) at the same temperature. A prior study of the fatigue behavior of this composite system at room temperature indicated that the SiC fiber reinforcement did not provide the anticipated improvement of fatigue resistance of this alloy. At 650 C, the composite fatigue properties degraded somewhat from those at room temperature. However, these properties degraded more for the unreinforced matrix at 650 C with the result that the composite fatigue strength was two to three times the fatigue strength of the matrix alloy. The reasons for this reversal are discussed in terms of crack initiation at broken fibers and residual matrix stresses.

Bhatt, R. T.↗

Evaluation of Stress Corrosion Cracking Susceptibility Using Fracture Mechanics Techniques, Part 1

Stress corrosion cracking (SSC) tests were performed on 13 aluminum alloys, 13 precipitation hardening stainless steels, and two titanium 6Al-4V alloy forgings to compare fracture mechanics techniques with the conventional smooth specimen procedures. Commercially fabricated plate and rolled or forged bars 2 to 2.5-in. thick were tested. Exposures were conducted outdoors in a seacoast atmosphere and in an inland industrial atmosphere to relate the accelerated tests with service type environments. With the fracture mechanics technique tests were made chiefly on bolt loaded fatigue precracked compact tension specimens of the type used for plane-strain fracture toughness tests. Additional tests of the aluminum alloy were performed on ring loaded compact tension specimens and on bolt loaded double cantilever beams. For the smooth specimen procedure 0.125-in. dia. tensile specimens were loaded axially in constant deformation type frames. For both aluminum and steel alloys comparative SCC growth rates obtained from tests of precracked specimens provide an additional useful characterization of the SCC behavior of an alloy.

Sprowls, D. O.↗

Testing and Analysis of Composite Skin/Stringer Debonding Under Multi-Axial Loading

Damage mechanisms in composite bonded skin/stringer constructions under uniaxial and biaxial (in-plane/out- of-plane) loading conditions were examined. Specimens consisted of a tapered composite flange bonded onto a composite skin. Tests were performed under monotonic loading conditions in tension, three-point bending, and combined tension/bending . For combined tension/bending testing, a unique servohydraulic load frame was used that was capable of applying both in-plane tension and out-of-plane bending loads simultaneously. Specimen edges were examined on the microscope to document the damage occurrence and to identify typical damage patterns. The observations showed that, for all three load cases, failure initiated in the flange, near the flange tip, causing the flange to almost fully debond from the skin. A two-dimensional plane-strain finite element model was developed to analyze the different test cases using a geometrically nonlinear solution. For all three loading conditions, principal stresses exceeded the transverse strength of the material in the flange area. Additionally, delaminations of various lengths were simulated in two locations where delaminations were observed. The analyses showed that unstable delamination propagation is likely to occur in one location at the loads corresponding to matrix ply crack initiation for all three load cases.

Krueger, Ronald↗

Debonding in Composite Skin/Stringer Configurations Under Multi-Axial Loading

The objective of this work was to investigate the damage mechanisms in composite bonded skin/stringer constructions under uniaxial and biaxial (in-plane/out-of-plane) loading conditions as typically experienced by aircraft crown fuselage panels. The specimens for all tests were identical and consisted of a tapered composite flange, representing a stringer or frame, bonded onto a composite skin. Tests were performed under monotonic loading conditions in tension, three-point bending, and combined tension/bending to evaluate the debonding mechanisms between the skin and the bonded stringer. For combined tension/bending testing, a unique servohydraulic load frame was used that was capable of applying both loads simultaneously. Microscopic investigations of the specimen edges were used to document the damage occurrence and to identify typical damage patterns. The observations showed that, for all three load cases, failure initiated in the flange near the flange tip causing the flange to almost fully debond from the skin. A two-dimensional plain-strain finite element model was developed to analyze the different test cases using a geometrically nonlinear solution. For all three loading conditions, principal stresses exceeded the transverse strength of the material in the flange area. Additionally, delaminations of various lengths were simulated in the locations where delaminations were experimentally observed. The analyses showed that unstable delamination propagation is likely to occur at the loads corresponding to matrix ply crack initiation for all three loadings.

Cvitkovich, Michael K.↗

Mechanisms of High-Temperature Fatigue Failure in Alloy 800H

The damage mechanisms influencing the axial strain-controlled Low-Cycle Fatigue (LCF) behavior of alloy 800H at 850 C have been evaluated under conditions of equal tension/compression ramp rates (Fast-Fast (F-F): 4 X 10(sup -3)/s and Slow-Slow (S-S): 4 X 10(sup -5)/s) and asymmetrical ramp rates (Fast-Slow (F-S): 4 x 10(sup -3)/s / 4 X 10(sup -5/s and Slow-Fast (S-F): 4 X 10(sup -5) / 4 X 10(sup -3)/s) in tension and compression. The fatigue life, cyclic stress response, and fracture modes were significantly influenced by the waveform shape. The fatigue lives displayed by different loading conditions were in the following order: F-F greater than S-S greater than F-S greater than S-F. The fracture mode was dictated by the ramp rate adopted in the tensile direction. The fast ramp rate in the tensile direction led to the occurrence of transgranular crack initiation and propagation, whereas the slow ramp rate caused intergranular initiation and propagation. The time-dependent processes and their synergistic interactions, which were at the basis of observed changes in cyclic stress response and fatigue life, were identified. Oxidation, creep damage, dynamic strain aging, massive carbide precipitation, time-dependent creep deformation, and deformation ratcheting were among the several factors influencing cyclic life. Irrespective of the loading condition, the largest effect on life was exerted by oxidation processes. Deformation ratcheting had its greatest influence on life under asymmetrical loading conditions. Creep damage accumulated the greatest amount during the slow tensile ramp under S-F conditions.

BhanuSankaraRao, K.↗

Unsteady Flow Simulations in Support of the SSME HEX Turning Vane Cracking Investigation with the ATD HPOTP

Unsteady flow computations are being performed with the P&W (ATD) and the Rocketdyne baseline configurations of the SSME LO2 turbine turnaround duct (TAD) and heat exchanger (HEX). The work is in support of the HEX inner turning vane cracking investigation. Fatigue cracking has occurred during hot firings with the P&W configuration on the HEX inner vane, and it appears the fix will involve changes to the TAD splitter vane position and to the TAD inner wall curvature to reduce the dynamic loading on the inner vane. Unsteady flow computations on the P&W baseline and fix and on the Rocketdyne baseline reference follow steady-flow screening computations done by MSFC/ED32 on several trial configurations arriving at the fix. The P&W TAD inlet velocity profile has a strong radial velocity component that directs the flow toward the inner wall and raises the local velocity a factor of two and the dynamic pressure a factor, of four. The fix is intended to redistribute the flow more evenly across the HEX inner and outer vanes like the Rocketdyne baseline reference. Vane buffeting at frequencies around 4,000 Hz is the leading suspected cause of the problem. Our simulations (work in progress) are being done with the USA 2D axisymmetric code approximating the flow as axisymmetric u+v 2D (axial, u, and radial, v, components only). The HEX coils are included in the model to make sure the fix does not adversely affect the HEX environment. Turbulent kinetic energy, k, levels where k = 1/2 v' rms2 are locally as high as 10,000 ft2/sec2 for the P&W baseline at the engine interface (between the TAD and HEX) at the HEX inner vane location. However, k is less than 8,000 on the HEX outer vane and only about 4,500 on the HEX inner vane for the Rocketdyne baseline. Unsteady turbulence intensity, v'rms/v, and pressure, p', are being computed in the present computations to compare with steady-flow Reynolds-averaged computations where p'rms = const (pk) for overall rms random turbulence from 0.1 to 12,000 Hz frequency. Random overall static, p'rms fluctuations as large as 1.7 psi are estimated from k on the HEX inner vane for the P&W baseline configuration but only about 0.7 psi for the Rocketdyne configuration.

Dougherty, N. S.↗

Time-Accurate Computational Fluid Dynamics Analysis of a Supersonic Turbine to Assess Structural Mode Excitation

Gas turbines can experience significant unsteady loading during operation which can cause damage such as blade cracking or bearing wear. While computational fluid dynamics (CFD) modeling of full three-dimensional gas turbine flow to verify meanline design performance is standard practice within the industry, the use of time-accurate CFD makes it possible to assess the unsteady loading which can be especially problematic at operating conditions where unsteady fluid loading aligns with structural modes. The Fluid Dynamics branch (ER42) at NASA Marshall Space Flight Center has developed a time-accurate CFD analysis methodology using the unstructured, density-based, Loci-CHEM solver which is capable of simulating the relative motion required for turbomachinery applications through sliding interface meshes. The highly-parallel unstructured solver allows for full three-dimensional, time-accurate simulation of turbines including upstream and downstream components such as manifolds, nozzles, and stators, any of which could excite a turbine structural mode. Recently, Loci-CHEM was used to analyze the FASTRAC supersonic turbine to assess the loading on the rotor. Overall performance and time-averaged loading on the rotor was computed, including the axial force over the entire rotor disk which is required for force balance calculations on the turbopump. The FASTRAC turbine has supersonic nozzles upstream of the rotor that result in significant unsteady loading on the rotor blades at multiples of the nozzle pass frequency. The unsteady blade pressure loading was decomposed into the frequency domain for direct use in structural forced response analysis. Utilizing this type of CFD analysis coupled with structural analysis has proven to be a valuable tool in identifying structural modes that are being excited by unsteady fluid loading.

M.V. Fischels↗

Time-Accurate Computational Fluid Dynamics Analysis of a Supersonic Turbine to Assess Structural Mode Excitation

Gas turbines can experience significant unsteady loading during operation which can cause damage such as blade cracking or bearing wear. While computational fluid dynamics (CFD) modeling of full three-dimensional gas turbine flow to verify meanline design performance is standard practice within the industry, the use of time-accurate CFD makes it possible to assess the unsteady loading which can be especially problematic at operating conditions where unsteady fluid loading aligns with structural modes. The Fluid Dynamics branch (ER42) at NASA Marshall Space Flight Center has developed a time-accurate CFD analysis methodology using the unstructured, density-based, Loci-CHEM solver which is capable of simulating the relative motion required for turbomachinery applications through sliding interface meshes. The highly-parallel unstructured solver allows for full three-dimensional, time-accurate simulation of turbines including upstream and downstream components such as manifolds, nozzles, and stators, any of which could excite a turbine structural mode. Recently, Loci-CHEM was used to analyze the FASTRAC supersonic turbine to assess the loading on the rotor. Overall performance and time-averaged loading on the rotor was computed, including the axial force over the entire rotor disk which is required for force balance calculations on the turbopump. The FASTRAC turbine has supersonic nozzles upstream of the rotor that result in significant unsteady loading on the rotor blades at multiples of the nozzle pass frequency. The unsteady blade pressure loading was decomposed into the frequency domain for direct use in structural forced response analysis. Utilizing this type of CFD analysis coupled with structural analysis has proven to be a valuable tool in identifying structural modes that are being excited by unsteady fluid loading.

M V Fischels↗

Unsteady Flowfield in a High-Pressure Turbine Modeled by TURBO

Forced response, or resonant vibrations, in turbomachinery components can cause blades to crack or fail because of the large vibratory blade stresses and subsequent high-cycle fatigue. Forced-response vibrations occur when turbomachinery blades are subjected to periodic excitation at a frequency close to their natural frequency. Rotor blades in a turbine are constantly subjected to periodic excitations when they pass through the spatially nonuniform flowfield created by upstream vanes. Accurate numerical prediction of the unsteady aerodynamics phenomena that cause forced-response vibrations can lead to an improved understanding of the problem and offer potential approaches to reduce or eliminate specific forced-response problems. The objective of the current work was to validate an unsteady aerodynamics code (named TURBO) for the modeling of the unsteady blade row interactions that can cause forced response vibrations. The three-dimensional, unsteady, multi-blade-row, Reynolds-averaged Navier-Stokes turbomachinery code named TURBO was used to model a high-pressure turbine stage for which benchmark data were recently acquired under a NASA contract by researchers at the Ohio State University. The test article was an initial design for a high-pressure turbine stage that experienced forced-response vibrations which were eliminated by increasing the axial gap. The data, acquired in a short duration or shock tunnel test facility, included unsteady blade surface pressures and vibratory strains.

Bakhle, Milind A.↗

Composite Bending Box Section Modal Vibration Fault Detection

One of the primary concerns with Composite construction in critical structures such as wings and stabilizers is that hidden faults and cracks can develop operationally. In the real world, catastrophic sudden failure can result from these undetected faults in composite structures. Vibration data incorporating a broad frequency modal approach, could detect significant changes prior to failure. The purpose of this report is to investigate the usefulness of frequency mode testing before and after bending and torsion loading on a composite bending Box Test section. This test article is representative of construction techniques being developed for the recent NASA Blended Wing Body Low Speed Vehicle Project. The Box section represents the construction technique on the proposed blended wing aircraft. Modal testing using an impact hammer provides an frequency fingerprint before and after bending and torsional loading. If a significant structural discontinuity develops, the vibration response is expected to change. The limitations of the data will be evaluated for future use as a non-destructive in-situ method of assessing hidden damage in similarly constructed composite wing assemblies. Modal vibration fault detection sensitivity to band-width, location and axis will be investigated. Do the sensor accelerometers need to be near the fault and or in the same axis? The response data used in this report was recorded at 17 locations using tri-axial accelerometers. The modal tests were conducted following 5 independent loading conditions before load to failure and 2 following load to failure over a period of 6 weeks. Redundant data was used to minimize effects from uncontrolled variables which could lead to incorrect interpretations. It will be shown that vibrational modes detected failure at many locations when skin de-bonding failures occurred near the center section. Important considerations are the axis selected and frequency range.

Werlink, Rudy↗

Exploration of Failure and Potential Damage Markers in Ti-6Al-4V

To improve prognostics for predicting component life, coupon tests were conducted on Ti-6Al-4V to investigate the development of damage. Various test types were employed (tension, creep, stress relaxation, and fatigue) under a wide range of temperatures and loading rates to engage various amounts of time-dependent and damage behavior. Both stiffness degradation and Poisson’s ratio were monitored to see if they were useful in indicating the initiation and accumulation of damage and subsequently the onset of failure. Stiffness exhibited large decreases with increasing strain when calculated using engineering stress and strain. However, minimal stiffness change was observed when using the true-stress and true- strain values. Detailed microscopy and image analysis were performed to document the actual physical damage that occurred within the various specimens. Two types of damage were observed: shallow surface cracks and internal pores. The severity of damage was greater in the region of localized necking and diminished further away from the neck. The area fraction of pores was higher in the necked region, yet even there it did not exceed more than a few percent and, in most cases, was significantly lower. It was observed that conditions that induced more time-dependent deformation (e.g., slower strain rate testing) resulted in a larger number of pores and larger pore sizes. The pores were always found to occur in the softer β-phase. The severity of observed damage was inconsistent with the large drop in engineering stiffness, but was more aligned with stiffness changes from the true-stress and -strain values. Poisson’s ratio was monitored on every test and showed promise as a damage indicator. It was found to be more sensitive than either the ultimate tensile strength or the inception of tertiary creep. However, calculation of Poisson’s ratio was found to be more involved than expected because of anisotropy and the presence of strain gradients along the specimen at large applied strains. First, the material had a moderate texture and resulted in anisotropy of the strains. Second, the evolution of Poisson’s ratio as a function of axial strain showed strange and unexpected behaviors, which necessitated more extensive analyses of its development. This led to an investigation on the use of small versus large strain approaches and the importance of making consistent measurements; that is, axial and transverse strain measurements over the same volume of material. Additionally, finite element analysis of a tensile sample indicated that non- uniform strain occurred in the sample prior to attaining the maximum strength. This, along with the location at which transverse strain was measured, had a significant influence on the resulting values of Poisson’s ratio. Based on this, lessons learned are offered for future testing.

Ti-6Al-4V↗