Search NASA⌕ Search

SEARCH · Search NASA

Results for “bacteria”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The effects of spacecraft environments on some hydrolytic enzyme patterns in bacteria

The effects of space flight on the production and characteristics of proteolytic enzymes are studied for a number of bacterial species isolated from crew members and spacecraft. Enzymatic make-up and cultural characteristics of bacteria isolated from spacecraft crew members are determined. The organism Aeromonas proteolytica and the proteolytic enzymes which it produces are used as models for future spacecraft experiments.

Prescott, J. M.↗

Automated detection of bacteria in urine

A method for detecting the presence of bacteria in urine was developed which utilizes the bioluminescent reaction of adenosine triphosphate with luciferin and luciferase derived from the tails of fireflies. The method was derived from work on extraterrestrial life detection. A device was developed which completely automates the assay process.

Fleig, A. J.↗

Bacteria detection instrument and method

A method and apparatus for screening a sample fluid for bacterial presence are disclosed wherein the fluid sample is mixed with culture media of sufficient quantity to permit bacterial growth in order to obtain a test solution. The concentration of oxygen dissolved in the test solution is then monitored using the potential difference between a reference electrode and a noble metal electrode which are in contact with the test solution. The change in oxygen concentration which occurs during a period of time as indicated by the electrode potential difference is compared with a detection criterion which exceeds the change which would occur absent bacteria.

Renner, W.↗

Tape Cassette Bacteria Detection System

The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

Source record↗

Fungi and Bacteria

Spacecraft equipment is usually protected from fungi and bacteria by incorporating a fungicide-bactericide in the material, by a fungicide-bactericide spray, or by reducing the relative humidity to a degree where growth will not take place. A unique method to protect delicate, expensive bearings in equipment was to maintain a pressure (with dry air or nitrogen) slightly above the outside atmosphere (few millibars) within the working parts of the equipment, thus preventing fungi from entering equipment.

Glenn E Daniels↗

Evidence for metabolic activity of airborne bacteria

Aerosols of the bacterium Serratia marcescens, and of uniformly labeled C-14 glucose were produced simultaneously and mixed in tubing leading to an aerosol chamber. During a subsequent period of about 5 hrs, carbon dioxide was produced metabolically within the chamber, and labeled material incorporated within the suspended particles first increased then decreased. This constitutes the first direct evidence of microbial metabolism of bacteria suspended in the air.

Chatigny, M. A.↗

Cassette bacteria detection system

The design, fabrication, and testing of an automatic bacteria detection system, with a zero-g capability, based on the filter-capable approach, and intended for monitoring the sterility of regenerated water in spacecraft is discussed. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins on a luminol-hydrogen peroxide mixture. Viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. High signals for the incubated water sample indicate the presence of viable organisms.

Source record↗

Salt-dependent properties of proteins from extremely halophilic bacteria

Based on information concerning the interaction of salts and macromolecules the literature of the enzymes of halophilic bacteria and their constituents is examined. Although in halophilic systems the salt requirement of enzyme activity is variable the enzymes investigated show a time-dependent inactivation at lower salt concentrations especially in the absence of salt. The studies described show that in some halophilic systems the effect of salt may be restricted to a small region on the protein molecule. The concept of the hydrophobic bond to consider certain solvent-dependent phenomena is introduced. It is shown that some halophilic enzymes are unable to maintain their structure without the involvement of hydrophobic interactions that are usually not supported by water. A table lists indices of hydrophobicity and polarity for various halophilic and nonhalophilic proteins.

Lanyi, J. K.↗

Method of detecting and counting bacteria

An improved method is provided for determining bacterial levels, especially in samples of aqueous physiological fluids. The method depends on the quantitative determination of bacterial adenosine triphosphate (ATP) in the presence of nonbacterial ATP. The bacterial ATP is released by cell rupture and is measured by an enzymatic bioluminescent assay. A concentration technique is included to make the method more sensitive. It is particularly useful where the fluid to be measured contains an unknown or low bacteria count.

Picciolo, G. L.↗

Several methods for concentrating bacteria in fluid samples

The sensitivities of the firefly luciferase - ATP flow system and luminol flow system were established as 300,000 E. coli per milliliter and 10,000 E. coli per milliliter respectively. To achieve the detection limit of 1,000 bacteria per milliliter previously established, a method of concentrating microorganisms using a sartorius membrane filter system is investigated. Catalase in 50% ethanol is found to be a stable luminol standard and can be used up to 24 hours with only a 10% loss of activity. The luminol reagent is also stable over a 24 hour period. A method of preparing relatively inexpensive luciferase from desiccated firefly tails is developed.

Thomas, R. R.↗

A comment on methanogenic bacteria and the primitive ecology

As the phenotype of methanogenic bacteria is suggested to have been one of the major factors creating a dynamic balance between CO2 and CH4 in the primitive atmosphere, these organisms are thought to be very ancient. Their antiquity may be further postulated by comparative characterization of their ribosomal RNA. Accepting this antiquity, it is concluded that a carbon-dioxide-methane cycle, driven by photosynthesis, was the major carbon cycle in primitive ecology, and that photosynthesis and methanogens were thus contemporaneous.

Woese, C. R.↗

Rapid measurement of bacteria in water

Automated analysis system detects bacteria in saltwater, freshwater, sewage effluent, and other aqueous media. System may be adapted for computer control.

Chappelle, E.↗

Are extreme halophiles actually 'bacteria'

Comparative cataloging of the 16S rRNA of Halobacterium halobium indicates that the organism did not arise, as a halophilic adaptation, from some typical bacterium. Rather, H. halobium is a member of the Archaebacteria, an ancient group of organisms that are no more related to typical bacteria than they are to eucaryotes.

Magrum, L. J.↗

Platinum electrodes for electrochemical detection of bacteria

Bacteria is detected electro-chemically by measuring evolution of hydrogen in test system with platinum and reference electrode. Using system, electrodes of platinum are used to detect and enumerate varieties of gram-positive and gram-negative organisms compared in different media.

Wilkins, J. R.↗

Indicator For Pseudomonas Bacteria

Characteristic protein extracted and detected. Natural protein marker found in Pseudomonas bacteria. Azurin, protein containing copper readily extracted, purified, and used to prepare antibodies. Possible to develop simple, fast, and accurate test for marker carried out in doctor's office.

Margalit, Ruth↗