Search NASA⌕ Search

SEARCH · Search NASA

Results for “bandwidth optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Numerical study and test of the APS linac transverse deflecting cavity

The transverse deflecting cavity can be used to transform particle distributions in the 6D phase space, which makes it a promising component in phase space beam diagnostics and beam manipulations. In the Advanced Photon Source (APS) Linac, a LOLA-type traveling wave deflecting cavity was installed for the diagnostics of beam characteristics, such as the bunch length, bunch temporal profile, time-dependent energy spread and slice (time-correlated) transverse emittance. In this paper, this deflecting cavity is modeled and analyzed with the numerical method. The effects of the center cell and coupler cell dimensions on the performance of the whole structure are studied, which shows the coupler cell radius has a dominant effect over the coupler cell length and slot width on the global reflection coefficient and field flatness. Important RF parameters, such as S-11, field flatness and phase advance etc., of the LOLA-II cavity in tuning are calculated and discussed. After optimization, the field flatness of the cavity is 2.1%, the phase advance is 119.66 degrees degrees with a standard deviation smaller than 0.5 degrees and the bandwidth is 15.738 MHz when VSWR < 1.1 (i.e. the S-11, < -26 dB). Bead-pull measurements and RF conditioning have been also performed and discussed. Finally, the initial cavity commissioning with electron beam of 375 MeV is reported, and compared with simulation.

coupler↗

Laser beam pointing stabilization using analog position-sensitive diodes

Laser wire scanners have been used for ion beam profile and emittance measurements at the Spallation Neutron Source linear accelerator. Due to propagation distances exceeding 100 m, reliable measurements require laser beam stabilization, previously accomplished with a feedback control loop using a digital camera as a position sensor [Hardin et al., Opt. Express 19, 2874 (2011)]. Here, this paper presents an upgraded pointing stabilization system utilizing analog position-sensitive diodes (PSDs) as the position detector, optimized with an optical diffuser. The new system significantly surpasses the previous system by offering an order-of-magnitude improvement in radiation tolerance and a bandwidth limited only by the burst repetition rate of the laser beam. Operating with a 60-Hz burst mode laser, the new system effectively suppresses laser beam drifts up to 30 Hz, compared to the previous system’s 4 Hz limit. In addition, the amplitude of spectral components below 0.1 Hz was reduced by a factor of more than 100, which is over seven times greater than was achieved by the previous system.

Data acquisition↗

Spectroscopic Fourth-order Coronagraph for the Characterization of Terrestrial Planets at Small Angular Separations from Host Stars

We propose a new approach for high-contrast imaging at the diffraction limit using segmented telescopes in a modest observation bandwidth. This concept, named “spectroscopic fourth-order coronagraphy,” is based on a fourth-order coronagraph with a focal-plane mask that modulates the complex amplitude of the Airy disk along one direction. While coronagraphs applying the complex amplitude mask can achieve the theoretical limit performance for any arbitrary pupils, the focal-plane mask severely limits the bandwidth. Here, focusing on the fact that the focal-plane mask modulates the complex amplitude along one direction, we noticed that the mask can be optimized for each spectral element generated by a spectrograph. We combine the fourth-order coronagraph with two spectrographs to produce a stellar spectrum on the focal plane and reconstruct a white pupil on the Lyot stop. Based on the wave-front analysis of an optical design applying an Offner-type imaging spectrograph, we found that the achievable contrast of this concept is 10{sup −10} at 1.2–1.5 times the diffraction limit over the wavelength range of 650–750 nm for the entrance pupil of the LUVOIR telescope. Thus, this coronagraph concept could bring new habitable planet candidates not only around G- and K-type stars beyond 20–30 pc but also around very nearby M-type stars. This approach potentially promotes the characterization of the atmospheres of nearby terrestrial planets with future on- and off-axis segmented large telescopes.

47 OTHER INSTRUMENTATION↗

Hierarchical Roofline analysis for GPUs: Accelerating performance optimization for the NERSC‐9 Perlmutter system

Summary The Roofline performance model provides an intuitive and insightful approach to identifying performance bottlenecks and guiding performance optimization. In preparation for the next‐generation supercomputer Perlmutter at NERSC, this paper presents a methodology to construct a hierarchical Roofline on NVIDIA GPUs and extends it to support reduced precision and Tensor Cores. The hierarchical Roofline incorporates L1, L2, device memory, and system memory bandwidths into one single figure, and it offers more profound insights into performance analysis than the traditional DRAM‐only Roofline. We use our Roofline methodology to analyze three proxy applications: GPP from BerkeleyGW, HPGMG from AMReX, and conv2d from TensorFlow. In doing so, we demonstrate the ability of our methodology to readily understand various aspects of performance and performance bottlenecks on NVIDIA GPUs and motivate code optimizations.

Yang, Charlene↗

Detector Interface for Streaming, Control, and Open-source integration (DISCO) v1.0.0

This suite consists of a multi-package ecosystem featuring detector emulators, EPICS areaDetector drivers, and remote server frameworks designed for the Advanced Light Source (ALS). Engineered for high-bandwidth devices—including VFCCD, Timepix3, Timepix4, and related pixel detectors—the software simulates hardware, wraps vendor SDKs into remote-callable servers, and integrates with open-source control systems. Key Capabilities: Distributed SDK Architecture: Server packages wrap hardware-specific SDKs, allowing areaDetector drivers to execute remote framework calls. This isolates proprietary libraries from the EPICS IOC, enhancing stability and enabling distributed computing across beamline networks. Device Support: Custom drivers for VFCCD, the Timepix family, and similar sensors optimize the data path from hardware control to high-speed transport. Full-Stack Emulation: Sophisticated emulator packages allow end-to-end pipeline testing and software development without requiring physical hardware or beam time. Integrated Workflows: Supports high-bandwidth streaming for real-time analysis and robust, metadata-rich file-based workflows (e.g., HDF5/NeXus). By standardizing interfaces across heterogeneous hardware, this suite reduces technical debt. It provides the ALS with a scalable, open-source solution to manage massive data rates within a unified control environment.

Mahl, Johannes [Lawrence Berkeley National Laborat↗

Simulated study of plasmonic coupling in noble bimetallic alloy nanosphere arrays

The plasmonic coupling between the interacting noble metal nanoparticles plays an important role to influence the optical properties of arrays. In this work, we have extended the Mie theory results of our recent communication to include the effect of particle interactions between the alloy nanoparticles by varying interparticle distance and number of particles. The localized surface plasmon resonance (LSPR) peak position, full width at half maxima (FWHM) and scattering efficiency of one dimensional (1D) bimetallic alloy nanosphere (BANS) arrays of earlier optimized compositions i.e. Ag{sub 0.75}Au{sub 0.25}, Au{sub 0.25}Cu{sub 0.75} and Ag{sub 0.50}Cu{sub 0.50} have been studied presently by using discrete dipole approximation (DDA) simulations. Studies have been made to optimize size of the nanosphere, number of spheres in the arrays, material and the interparticle distance. It has been found that both the scattering efficiency and FWHM (bandwidth) can be controlled in the large region of the electromagnetic (EM) spectrum by varying the number of interacting particles and interparticle distance. In comparison to other alloy arrays, Ag{sub 0.50}Cu{sub 0.50} BANS arrays (each of particle radius 50 nm) shows larger tunability of LSPR with wide bandwidth (essential condition for plasmonic solar cells)

36 MATERIALS SCIENCE↗

The Macromolecular Neutron Diffractometer MaNDi at the Spallation Neutron Source

The Macromolecular Neutron Diffractometer (MaNDi) is located on beamline 11B of the Spallation Neutron Source at Oak Ridge National Laboratory. Moreover, the instrument is a neutron time-of-flight wavelength-resolved Laue diffractometer optimized to collect diffraction data from single crystals. Finally, the instrument has been designed to provide flexibility in several instrumental parameters, such as beam divergence and wavelength bandwidth, to allow data collection from a range of macromolecular systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Compton gamma-ray sources at LLNL

Compact Compton scattering gamma-ray sources offer the potential of studying nuclear photonics with new tools. The optimization of such sources depends on the final application, but generally requires maximizing the spectral density (photons/eV) of the gamma-ray beam while simultaneously reducing the overall bandwidth on target to minimize noise. We have developed an advanced design for one such system, comprising the RF drive, photoinjector, accelerator, and electron-generating and electron-scattering laser systems. This system uses a 120 Hz, 250 pC, 2 ps, 0.35 mm mrad electron beam with 250 MeV maximum energy in an X-band accelerator scattering off a 150 mJ, 10 ps, 532 nm laser to generate 5 Multiplication-Sign 10{sup 10} photons/eV/s/Sr at 0.5 MeV with an overall bandwidth of less than 1%. The source will be able to produce photons up to energies of 2.5 MeV. We also discuss Compton scattering gamma-ray source predictions given by numerical codes.

43 PARTICLE ACCELERATORS↗

A compact and portable gamma-ray spectrometer (GRASP) for inertial confinement fusion and basic science experiments

A compact and portable gamma-ray spectrometer has been designed to diagnose different components of the inertial confinement fusion-relevant γ-ray spectrum with energies between ∼3.7–17.9 MeV. The system is designed to be as compact as possible for convenient transportation and fielding in diagnostic ports on the OMEGA laser, the National Ignition Facility, and other photon-source facilities. The system consists of a conversion foil for Compton scattering in front of four magnetic spectrometer “arms,” each covering a different energy range and constructed out of cylindrical permanent magnet Halbach arrays. Monte Carlo simulations have been used to optimize and assess the performance of the conversion foil, and COSY INFINITY ion-optical simulations have been used to optimize the spectrometer magnets. The performance of the design is assessed for a simulated direct-drive γ-ray spectrum. Spanning its total γ-ray energy bandwidth and using a 1.7 mm thick boron conversion foil, the system’s total energy resolution and efficiency are ∼15.8%–4.5% and 5.4 × 10−7–3.7 × 10−7e−/γ, respectively, with room for improvement. Spectral γ-ray measurements will provide guidance to the inertial confinement fusion program toward achieving high-energy gain relevant to inertial fusion energy and enable new measurement capabilities for basic discovery science.

Instruments & Instrumentation↗

SU-F-J-163: In Vivo Quantification of Sequence Parameter Effect On Geometric Distortion Caused by Implanted Titanium Brachytherapy Applicator

Purpose: The use of MR to plan and evaluate brachytherapy treatment for cervical cancer is increasing given the availability of MR conditional or safe applicators and MRI’s proven superiority to CT for characterizing soft tissue lesions. The titanium applicators, however, cause geometric distortions or imaging artifacts, which reduce the utility of MRI for dosimetry. We sought to quantify the observed volume of the same applicator on a previously optimized T2 sequence in comparison to the conventional T2 sequence and CT obtained for brachytherapy planning. Methods: Prior work with testing in phantoms showed that increases in readout bandwidth yielded reductions in artifact area and distortion measurements even with voxel increases. Following IRB approval, nine patients with titanium tandem & ovoid applicator (Varian Medical Systems) in place were scanned with a standard periprocedural protocol which included sagittal T2 fast spin echo (FSE) acquisition (res 0.98×0.78×4.0 mm{sup 3}; BW 200Hz). An additional T2-weighted FSE sequence (res 0.98×0.98×3–4 mm{sup 3}; BW500Hz) with increased readout bandwidth, readout voxel size, and echo train length was added to the protocol. Volume measurements of the applicator (from tip to cervical stop) were hand-segmented in Velocity AI 3.1 (Velocity Medical Solutions) for the two T2 FSE sequences and a planning CT obtained shortly after MRI. Differences were analyzed using a paired t-test. Results: Average apparent volumes of the applicator on standard T2 sequence, decreased bandwidth T2 sequence and CT were 5.922±1.283 cm{sup 3}, 4.544±1.524 cm3, and 2.304±0.509 cm{sup 3} respectively. Conclusion: Apparent volumes of a brachytherapy applicator can be compared in vivo. The modified sequence results in decreased apparent size of the cervical applicator. Both MR sequence volumes were larger than the planning CT, which was expected. Future work will focus on the diagnostic quality of the new sequence and quantifying any geometric shifts after CT to MRI registration based on anatomical landmarks.

60 APPLIED LIFE SCIENCES↗

Spectral broadening and compression of picosecond pulses in air using a multi-pass cell

We report the spectral broadening and post-compression of picosecond pulses using a multi-pass cell (MPC) operating in air. A 2 m-long bi-concave cavity with 41 reflections and 96.4% transmission was designed and implemented, optimized for the compression of 5.5 ps, 4.5 mJ pulses from a Yb:YAG laser operating at 1030 nm. A 19.3-fold spectral broadening was obtained, increasing the bandwidth from 0.3 nm to 5.8 nm, which enabled pulse compression down to 547 fs with a symmetric temporal profile close to the transform limit. These results demonstrate the feasibility of using open-air MPCs for high-energy picosecond pulse post-compression, without the need for sealed chambers, while preserving high mode quality and transmission. Scaling to pulse higher energy is discussed.

Zaldivar Escola, F. [Univ. of Buenos Aires (Argent↗

Programming Strategies for Irregular Algorithms on the Emu Chick

The Emu Chick prototype implements migratory memory-side processing in a novel hardware system. Rather than transferring large amounts of data across the system interconnect, the Emu Chick moves lightweight thread contexts to near-memory cores before the beginning of each remote memory read. Previous work has characterized the performance of the Chick prototype in terms of memory bandwidth and programming differences from more typical, non-migratory platforms, but there has not yet been an analysis of algorithms on this system. This work evaluates irregular algorithms that could benefit from the lightweight, memory-side processing of the Chick and demonstrates techniques and optimization strategies for achieving performance in sparse matrix-vector multiply operation (SpMV), breadth-first search (BFS), and graph alignment across up to eight distributed nodes encompassing 64 nodelets in the Chick system. We also define and justify relative metrics to compare prototype FPGA-based hardware with established ASIC architectures. The Chick currently supports up to 68x scaling for graph alignment, 80 MTEPS for BFS on balanced graphs, and 50% of measured STREAM bandwidth for SpMV.

Hein, Eric↗

Asynchronous Two-Level Checkpointing Scheme for Large-Scale Adjoints in the Spectral-Element Solver Nek5000

Adjoints are an important computational tool for large-scale sensitivity evaluation, uncertainty quantification, and derivative-based optimization. An essential component of their performance is the storage/recomputation balance in which efficient checkpointing methods play a key role. We introduce a novel asynchronous two-level adjoint checkpointing scheme for multistep numerical time discretizations targeted at large-scale numerical simulations. The checkpointing scheme combines bandwidth-limited disk checkpointing and binomial memory checkpointing. Based on assumptions about the target petascale systems, which we later demonstrate to be realistic on the IBM Blue Gene/Q system Mira, we create a model of the expected performance of our checkpointing approach and validate it using the highly scalable Navier-Stokes spectralelement solver Nek5000 on small to moderate subsystems of the Mira supercomputer. In turn, this allows us to predict optimal algorithmic choices when using all of Mira. We also demonstrate that two-level checkpointing is significantly superior to single-level checkpointing when adjoining a large number of time integration steps. To our knowledge, this is the first time two-level checkpointing had been designed, implemented, tuned, and demonstrated on fluid dynamics codes at large scale of 50k+ cores.

Adjoints↗

Optimized illumination for high-throughput ptychography

As a scanning version of coherent diffraction imaging (CDI), X-ray ptychography has become a popular and very successful method for high-resolution quantitative imaging of extended specimens. The requirements of mostly coherent illumination and the scanning mechanism limit the throughput of ptychographic imaging. In this paper, we will introduce the methods we use at the Advanced Photon Source (APS) to achieve high-throughput ptychography by optimizing the parameters of the illumination beam. One work we have done is increasing the illumination flux by using a double-multilayer monochromator (DMM) optics with about 0.8% bandwidth. Compared with our double-crystal monochromator (DCM) optics with 0.01% bandwidth, this DMM optics provides around 20 times more flux. A multi-wavelength reconstruction method has been implemented to deal with the consequential degraded temporal coherence from such an illumination to ensure high-quality reconstruction. In the other work, we adopt a novel use of flat-top focusing optics to generate a flat-top beam with the diameter of about 1.5 µm on the focal plane. The better uniformity of the probe and the large beam size allow one to significantly increase the step size in ptychography scans and thereby the imaging efficiency.

Broad bandwidth↗

A Pixel Pitch-Matched Ultrasound Receiver for 3-D Photoacoustic Imaging With Integrated Delta-Sigma Beamformer in 28-nm UTBB FD-SOI

This study presents a pixel pitch-matched readout chip for 3-D photoacoustic (PA) imaging, featuring a dedicated signal conditioning and delta-sigma modulation integrated within a pixel area of 250 μm by 250 μm. The proof-of-concept receiver was implemented in an STMicroelectronics's 28-nm Fully Depleted Silicon On Insulator technology, and interfaces to a 4 × 4 subarray of capacitive micromachined ultrasound transducers (CMUTs). The front-end signal conditioning in each pixel employs a coarse/fine gain tuning architecture to fulfill the 90-dB dynamic range requirement of the application. The employed delta-sigma beamforming architecture obviates the need for area-consuming Nyquist ADCs and thereby enables an efficient in-pixel A/D conversion. The per-pixel switched-capacitor ΔΣ modulator leverages slewing-dominated and area-optimized inverter-based amplifiers. It occupies only 1/4th of the pixel, and its area compares favorably with state-of-the-art designs that offer the same SNR and bandwidth. The modulator's measured peak signal-to-noise-and-distortion ratio is 59.9 dB for a 10-MHz input bandwidth, and it consumes 6.65 mW from a 1V supply. The overall subarray beamforming approach improves the area per channel by 7.4 times and the single-channel SNR by 8 dB compared to prior art with similar delay resolution and power dissipation. Finally, the functionality of the designed chip was evaluated within a PA imaging experiment, employing a flip-chip bonded 2-D CMUT array.

3-D photoacoustic (PA) imaging↗

Evaluating and Optimizing OpenCL Base64 Data Unpacking Kernel with FPGA

Development of applications using OpenCL targeting FPGAs is an emerging approach on heterogeneous computing systems. This paper uses the data unpacking algorithm in Base64 encoding as a case study to present programming and optimization techniques, and experimental results of the OpenCL-based implementations on an FPGA. We explain the algorithm and evaluate the performance of the kernel implementations with Intel's FPGA OpenCL SDK. The experimental results show kernel vectorization and duplication are two optimization techniques that can improve the kernel performance. The performance of kernel duplication is also closely related to the local work size. Our experiment shows 16-lane vectorization increases the bandwidth by a factor of 2 to 10 for large input data sizes. Moreover, the performance of kernel duplication using 16 compute units is 40% to 1.5% less than that of kernel vectorization depending on the input size. Tuning the local work size can improve the kernel performance by a factor of 3 to 23. For this kernel, using local memory is not an effective technique to improve the kernel performance because input data is not reused. A combination of vectorization and duplication achieves the highest performance of 12.3 GiB/s. Compared to an Intel Xeon E5 CPU and an Nvidia Tesla K80 GPU, the performance of the kernel on the Arria 10 FPGA is 6.7X faster than the CPU and 3X slower than the GPU. The performance per watt on the FPGA is 20.5X higher than the CPU and 1.19X lower than the GPU.

Base64 Encoding↗

Ultra-high Bandwidth, Ultra-high Dynamic Range X-Ray Shock Characterization via Photonic Integrated Circuit

Nuclear weapon component assessment tests at the Z Machine rely on accurate X-ray yield measurements for model validation, design and analysis of component survivability, and source optimization. Yield measurement devices currently used do not provide the requisite certainty to enable accurate and efficient data analysis of test results, which leads to an increase in Z-shots required for evaluation, longer device development times, and higher operation costs. Additionally, current X-ray flux detectors lack high temporal resolution at the tails. Similarly, shock measurement techniques used for component assessment often lack the ability to spatially resolve wave behavior thereby limiting the ability to measure shock propagation dynamics needed to design the next generation of ND components. Here we present the development of a photonic micro-calorimeter and shock sensor consisting of meter-long waveguide spirals that are optomechanically coupled to X-ray absorbing layers to characterize yield and shock propagation at nanosecond timescales.

42 ENGINEERING↗

Integrated Silicon Fourier Transform Spectrometer with Broad Bandwidth and Ultra‐High Resolution

An ultra-high resolution Fourier transform spectrometer (FTS) realized in silicon photonic platform that can operate with broad band, narrow band as well as a combination of broad band and narrow band signals is reported. The ultra-high resolution of the spectrometer is achieved by exploiting multiple techniques: a Michelson interferometer (MI) structure to increase the optical path delay (OPD), a hybrid waveguide design to reduce insertion loss, an optimized heater and air trenches to achieve higher thermal efficiency. Here, to further increase the OPD of the spectrometer to increase its resolution, a novel multiple interferometers approach is employed which combines balanced MI with N statically imbalanced MIs, thereby increasing the OPD of a single MI by factor of N + 1. An FTS spectrometer consisting of N = 2 such MIs is fabricated and experimentally characterized using unknown broad bandwidth input signal spectra of about 180 nm centered around 1550 nm, a narrow line laser input signal, and a combination of broad and narrow band signals demonstrating spectral resolution of about 0.16 nm.

Li, Ang↗