Search NASA⌕ Search

SEARCH · Search NASA

Results for “battery charge controller”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Coordinated Thermal Safety Attack and Defense on EV Battery Management Systems

Battery temperature sensor and battery current sensor data which are key sensing inputs to the Battery Management Controllers in electric vehicles, are vulnerable to possible cyber/ physical manipulation due to known vulnerabilities inherited from CAN bus technology that is used for in-vehicle communications between electronic control units that transfer sensing and control data. In this paper, we first create a simulation that enables us to evaluate impact of cyber physical attacks on electric vehicle battery management system in a controlled environment that violates thermal safety. Specifically, we emulate a Level 3 - DC fast charging system with SAE J1772/CCS, integrated with standard charging controls and thermal safety controls on EVs, and various sensing data flows. Second, we propose a coordinated current and battery temperature attack that has crippling economic, and safety impacts. Third, we quantify the usability, economic and safety impacts of such attacks as a function of the extent of data manipulation. Finally, we propose a physics model driven detection technique to detect presence of such attacks.

25 ENERGY STORAGE↗

Kinetic Control over Disproportionation Stabilizes Wurster’s Blue Catholyte for Nonaqueous Redox Flow Batteries

Redoxmers are organic molecules that serve as charge carriers in redox flow batteries. While these materials are affordable and easy to source, insufficient stability of their charged states (radical ions) remains a challenge. A common reaction of these species is their disproportionation. Furthermore, this reversible reaction yields unstable multiply charged states, shifting the overall charge transfer equilibrium toward the decomposition products. Here we show how kinetic controls can be engineered into a redoxmer molecule to suppress these unwanted charge transfer reactions. This approach is used to transform Wurster's blue, which is historically the first example of a stable radical ion in organic chemistry, into an exceptionally durable redoxmer molecule that persists over thousands of electrochemical cycles.

Cations↗

Pocket nickel cadmium cell and battery evaluation

The Nickel Cadmium 129-ampere hour cell was tested in order to characterize the cell under controlled conditions. Results of charge characterization and discharge characterization are reported. Ampere hour efficiency, open circuit stand, and cycle life operation results are included. The battery is briefly described.

Lear, J. W.↗

A Neural Optimizer With Decision-Focused Learning for Optimal Energy Storage Operation

Here, this article introduces a neural optimizer-based framework for optimizing battery energy storage system (BESS) control for grid services, including demand charge and energy cost reduction. By leveraging decision-focused learning (DFL), the proposed framework ensures seamless integration and adaptation, significantly enhancing control performance. A patch time-series transformer is employed for peak load forecasting, incorporating aleatoric uncertainty quantification to account for forecasting uncertainties within the decision-making process. The framework utilizes a solver-in-the-loop approach to generate optimal BESS actions, which are then used to train the neural optimizer-based agent. By co-optimizing both BESS operational modes and output power within the NN, the system achieves improved performance and robustness. After initial training, the forecasting and control models are jointly fine-tuned to account for forecasting errors, further improving decision precision and efficiency through DFL. Case studies are performed to validate the performance of the framework using multiple real-world datasets, demonstrating superior performance in monthly peak load forecasting compared to state-of-the-art models. In addition, the results are compared against existing decision-making approaches. The results demonstrate a reduction in monthly peak forecasting error by approximately 15% across various performance measures and achieve an optimization gap for BESS operation that is about three times smaller compared to existing methods.

Kim, Hyeonjin [Pacific Northwest National Laborato↗

Rechargeable, silver-zinc battery conditioner/monitor unit and state-of-charge indicator

Unit automatically charges batteries to desired state-of-charge levels, monitors functional battery parameter data both on meters and printer, and automatically activates alarm in event of battery malfunctions. Unit consists of state-of-charge indicator panel, control panel, monitor panel, power panel, charging-current power supply, and load panel.

Thomas, C. E.↗

Preventing Voltage Divergence in Series-Stacked Bidirectional Battery Energy Storage DC-DC Converter under Asymmetrical Operating Conditions

DC stacked topologies have gained popularity for interfacing individual photovoltaic panels to a high-voltage DC bus. A similar approach can be used to interface individual battery packs to the same DC bus, which allows active balancing of battery substrings and the use of lower voltage switches. Any imbalance in battery current, however, can cause the converter output voltages to diverge. This paper describes the source of voltage divergence and demonstrates a solution that allows seamless stacking of multiple battery packs to be interfaced to a high voltage DC bus. To prevent the voltage divergence phenomenon and allow asymmetrical battery charging for efficient battery state of charge management, the PI-based decentralized voltage control enabling both capacitor voltage sharing and asymmetrical capacitor voltage control is proposed. The effectiveness of the decentralized voltage control strategy is demonstrated through controller hardware-in-the-loop test results.

Kim, Namwon↗

Multivariate prognosis of battery advanced state of health via transformers

De-risking energy storage investments necessary to meet CO 2 reduction targets requires a deep understanding of the connections between battery health, design, and use. The historical definition of the battery state of health (SOH) as the percentage of current versus initial capacity is inadequate for this purpose, motivating an expanded SOH consisting of an interrelated set of descriptors including capacity, energy, ionic and electronic impedances, open-circuit voltages, and microstructure metrics. In this work, we introduce deep transformer networks for the simultaneous prognosis of 28 battery SOH descriptors using two cycling datasets representing six lithium-ion cathode chemistries, multiple electrolyte/anode compositions, and different charge-discharge scenarios. The accuracy of these predictions for battery life (with an unprecedented mean absolute error of 19 cycles in predicting end of life for a lithium-iron-phosphate fast-charging dataset) illustrates the promise of deep learning toward providing enhanced understanding and control of battery health.

25 ENERGY STORAGE↗

System Assessment of a High Power 3-U CubeSat

The Advanced eLectrical Bus (ALBus) CubeSat project is a technology demonstration mission of a 3-UCubeSat with an advanced, digitally controlled electrical power system capability and novel use of Shape Memory Alloy (SMA) technology for reliable deployable solar array mechanisms. The objective of the project is to, through an on orbit demonstration, advance the state of power management and distribution (PMAD) capabilities to enable future missions requiring higher power, flexible and reliable power systems. The goals of the mission include demonstration of: 100 Watt distribution to a target electrical load, efficient battery charging in the orbital environment, flexible power system distribution interfaces, adaptation of power system control on orbit, and reliable deployment of solar arrays and antennas utilizing re-settable SMA mechanisms. The power distribution function of the ALBus PMAD system is unique in the total power to target load capability of 100 W, the flexibility to support centralized or point-to-load regulation and ability to respond to fast transient power requirements. Power will be distributed from batteries at 14.8 V, 6.5 A to provide 100 W of power directly to a load. The deployable solar arrays utilize NASA Glenn Research Center superelastic and activated Nitinol(Nickel-Titanium alloy) Shape Memory Alloy (SMA) technology for hinges and a retention and release mechanism. The deployable solar array hinge design features utilization of the SMA material properties for dual purpose. The hinge uses the shape memory properties of the SMA to provide the spring force to deploy the arrays. The electrical conductivity properties of the SMA also enables the design to provide clean conduits for power transfer from the deployable arrays to the power management system. This eliminates the need for electrical harnesses between the arrays and the PMAD system in the ALBus system design. The uniqueness of the SMA retention and release mechanism design is the ability to reset the mechanism, allowing functional tests of the mechanisms prior to flight with no degradation of performance. The project is currently in preparation at the NASA Glenn Research Center for a launch in late calendar year of 2017. The 100 Watt power distribution and dual purpose, re-settable SMA mechanisms introduced several system level challenges due to the physical constraints in volume, mass and surface area of 3-U CubeSats. Several trade studies and design cycles have been completed to develop a system which supports the project objectives. This paper is a report on the results of the system level trade studies and assessments. The results include assessment of options for thermal control of 100 Watts of power dissipation, data from system analyses and engineering development tests, limitations of the 3-U system and extensibility to larger scale CubeSat missions.

CubeSat↗

Flight Deck Design of a Hybrid Turbine/Electric Passenger Aircraft

NASA is exploring the development of a 180-passenger subsonic single engine aft turbine aircraft, The aft turbine provides electric power in a hybrid design to wing mounted electric engines, creating a highly efficient, high-bypass-ratio fan equivalent. The SUbsonic Single Aft eNgine (SUSAN) aircraft is being developed as a sustainable subsonic regional aircraft that seeks to reduce emission levels by 50% in the next few decades. Pilot-in-the-loop studies were conducted at the NASA Langley Research Center in Hampton, Virginia, to explore the flight deck design for the hybrid electric aircraft. Following modern trends in commercial aircraft flight decks with full time augmented controls and a quiet and dark philosophy, single throttle and simplified engine displays were developed for the SUSAN aircraft. The aircraft includes a single aft mounted turbine engine and 16 wing mounted electric fans. The final design was developed from feedback received during an earlier pilot-in-the-loop study where one, two, and three throttles were tested in standard airline operations, including various failures of the turbine and electric engines. Current flight deck designs normally provide control inceptors for each propulsion engine and an engine display for all primary aircraft engine parameters. With full time augmentation expected, a single throttle control with autothrottle always engaged, even during failures, is desired. Augmentation of flight controls using distributed thrust also requires full time control of the electric engines using automation. Additionally, electric engine thrust is augmented during climb based on battery state of charge. Thrust augmentation changes faster than human reaction time and therefore requires full-time automation. A pilot-in-the-loop study was conducted at the NASA Langley Research Center in Hampton, Virginia, to test the final design of the single throttle with simplified engine displays. Fourteen airline pilots evaluated the single throttle and engine display concept. Electric engine failures included one, four symmetric, and eight non-symmetric electric engine failures. The turbine engine was evaluated for complete and partial failure during critical phases of flight to include takeoff as well as enroute. Unexpected go-arounds increase workload and require significant throttle manipulation. Go-arounds were included to ensure the single throttle was usable for all phases of flight. Failures during takeoff required a return to the departure field and failures enroute required a diversion except for one and four electric engine failures as these failures did not affect aircraft flyability or range. There are currently no Part 25 aircraft certified with hybrid systems or electric engines with batteries as emergency propulsion. For turbine engine failures in the SUSAN aircraft design, range is limited to 30 minutes at full power. Battery state of charge and battery health displays were developed and tested for usability and to determine how well they supported pilot decisions for alternate airports during emergency diversions. Novel displays using shape and color were developed to provide immediate feedback when state of charge became critical. This paper details the pilot study including pilot feedback supporting the potential for increased automation and a single throttle control. Detailed recommendations are provided for a novel single throttle control and additional pilot controls to support selection of engines during start, shutdown, and engine troubleshooting procedures. This design deviates significantly from current practice of providing throttles for each propulsion engine. Engine display recommendations are provided based on pilot feedback during a guided post-evaluation interview. Battery state of charge and battery health display recommendations were collected from all airline crews. The simplified engine displays design was rated excellent as measured with a usability scale. Quantitative metrics include airspeed tracking, time to complete checklists, time to make diversion decisions and the quality of the diversion decision. Recommendations for future studies are documented with supporting research and current observations about upcoming flight deck certifications.

autothrottle↗

Flight Deck Design of a Hybrid Turbine/Electric Passenger Aircraft

NASA is exploring the development of a 180-passenger subsonic single engine aft turbine aircraft, The aft turbine provides electric power in a hybrid design to wing mounted electric engines, creating a highly efficient, high-bypass-ratio fan equivalent. The SUbsonic Single Aft eNgine (SUSAN) aircraft is being developed as a sustainable subsonic regional aircraft that seeks to reduce emission levels by 50% in the next few decades. Pilot-in-the-loop studies were conducted at the NASA Langley Research Center in Hampton, Virginia, to explore the flight deck design for the hybrid electric aircraft. Following modern trends in commercial aircraft flight decks with full time augmented controls and a quiet and dark philosophy, single throttle and simplified engine displays were developed for the SUSAN aircraft. The aircraft includes a single aft mounted turbine engine and 16 wing mounted electric fans. The final design was developed from feedback received during an earlier pilot-in-the-loop study where one, two, and three throttles were tested in standard airline operations, including various failures of the turbine and electric engines. Current flight deck designs normally provide control inceptors for each propulsion engine and an engine display for all primary aircraft engine parameters. With full time augmentation expected, a single throttle control with autothrottle always engaged, even during failures, is desired. Augmentation of flight controls using distributed thrust also requires full time control of the electric engines using automation. Additionally, electric engine thrust is augmented during climb based on battery state of charge. Thrust augmentation changes faster than human reaction time and therefore requires full-time automation. A pilot-in-the-loop study was conducted at the NASA Langley Research Center in Hampton, Virginia, to test the final design of the single throttle with simplified engine displays. Fourteen airline pilots evaluated the single throttle and engine display concept. Electric engine failures included one, four symmetric, and eight non-symmetric electric engine failures. The turbine engine was evaluated for complete and partial failure during critical phases of flight to include takeoff as well as enroute. Unexpected go-arounds increase workload and require significant throttle manipulation. Go-arounds were included to ensure the single throttle was usable for all phases of flight. Failures during takeoff required a return to the departure field and failures enroute required a diversion except for one and four electric engine failures as these failures did not affect aircraft flyability or range. There are currently no Part 25 aircraft certified with hybrid systems or electric engines with batteries as emergency propulsion. For turbine engine failures in the SUSAN aircraft design, range is limited to 30 minutes at full power. Battery state of charge and battery health displays were developed and tested for usability and to determine how well they supported pilot decisions for alternate airports during emergency diversions. Novel displays using shape and color were developed to provide immediate feedback when state of charge became critical. This paper details the pilot study including pilot feedback supporting the potential for increased automation and a single throttle control. Detailed recommendations are provided for a novel single throttle control and additional pilot controls to support selection of engines during start, shutdown, and engine troubleshooting procedures. This design deviates significantly from current practice of providing throttles for each propulsion engine. Engine display recommendations are provided based on pilot feedback during a guided post-evaluation interview. Battery state of charge and battery health display recommendations were collected from all airline crews. The simplified engine displays design was rated excellent as measured with a usability scale. Quantitative metrics include airspeed tracking, time to complete checklists, time to make diversion decisions and the quality of the diversion decision. Recommendations for future studies are documented with supporting research and current observations about upcoming flight deck certifications.

autothrottle↗

Enabling Extreme Fast Charging through Control of Li Deposition Overpotential on Graphite Electrodes

Currently produced electric vehicles (EVs) rely on the use of lithium ion battery technology due to its high energy and power density. However, a major barrier facing the adoption of electric vehicles is that currently utilized Li-ion batteries take significantly longer to recharge (~ 30 minutes) compared to the time necessary to refuel vehicles powered by internal combustion engines (< 10 minutes). Thus, the need to develop Li-ion batteries which can be charged in approximately 10 minutes (6 C rate) without sacrificing range, cost, or cycle life is critical for the widespread implementation of EVs.

25 ENERGY STORAGE↗

Guaranteeing a Physically Realizable Battery Dispatch Without Charge-Discharge Complementarity Constraints

The non-convex complementarity constraints present a fundamental computational challenge in energy constrained optimization problems. In this work, we present a new, linear, and robust battery optimization formulation that sidesteps the need for battery complementarity constraints and integers and prove analytically that the formulation guarantees that all energy constraints are satisfied which ensures that the optimized battery dispatch is physically realizable. In addition, we bound the worst-case model mismatch and discuss conservativeness. In conclusion, simulation results further illustrate the effectiveness of this approach.

25 ENERGY STORAGE↗

Applications technology satellites battery and power system design

A summary of the ATS battery design which is onboard the Applications Technology Satellite (ATS) is provided. The 15 ampere hour nickel cadmium cells were manufactured by Gulton, 19 series connected cells per battery, and there are two batteries in each spacecraft. The operating design life was two years in a synchronous orbit, and a maximum depth of discharge of 50 percent. The design temperature for the batteries in the spacecraft was 0 to 25 C, and the charge control consisted of 1 volt versus temperature on a constant percentage voltage. Also, C/10 current limit, and a commandable trickle charge rate, using C/20 or C/60. The undervoltage was sent across a 9 cell and a 10 cell group, and it was set at one volt average per group on either group.

Ford, F. E.↗

Air Force nickel-hydrogen experiment

An experiment to obtain some flight experience with a nickel-hydrogen battery in low earth orbit is described. The battery was built to be as compatible with the satellite bus as possible because the satellite bus is used for recharge power. The battery is mounted on an experimental pallet on the satellite. It has its own charge control system, a modification of an existing system that is used for nickel-cadmium, which primarily uses temperature compensated voltage as its criteria. Also, on the pallet is a load bank, a resistive load band, which allows switch to various load regimes. There is some other equipment on the satellite such as the nickel-hydrogen battery to power it. Monitors attached to the 21-cell battery are described.

Harsch, B.↗

Design Considerations of a Coordinative Demand Charge Mitigation Strategy

This paper presents a coordinative demand charge mitigation (DCM) strategy for reducing electricity consumption during system peak periods. Available DCM resources include batteries, diesel generators, controllable loads, and conservation voltage reduction. All resources are directly controlled by load serving entities. A mixed integer linear programming based energy management algorithm is developed to optimally coordinate of DCM resources considering the load payback effect. To better capture system peak periods, two different kinds of load forecast are used: the day-ahead load forecast and the peak-hour probability forecast. Five DCM strategies are compared for reconciling the discrepancy between the two forecasting results. The DCM strategies are tested using actual utility data. Simulation results show that the proposed algorithm can effectively mitigate the demand charge while preventing the system peak from being shifted to the payback hours. We also identify the diminishing return effect, which can help load serving entities optimize the size of their DCM resources.

Hu, Rongxing↗

Apparatus and system for controlling power to an air conditioning compressor for a vehicle

A climate control system for vehicles includes an internal combustion engine that may be coupled to selectively power a first motor generator, and an air conditioning compressor that may be selectively powered by one or both of the first motor generator and a second motor generator, or by the internal combustion engine. The system may include a rechargeable battery, and a vehicle controller having a vehicle state circuit structured to determine a vehicle operating condition value and a state-of-charge value of the rechargeable battery, and a coupling determination circuit structured to provide an internal combustion engine-first motor generator coupling command in response to the vehicle operating condition value and the state-of-charge value. In response to the internal combustion engine-first motor generator coupling command being provided as coupled, the internal combustion engine may power the first motor generator.

Kumar, Mahesh Madurai↗

Circuit with a Switch for Charging a Battery in a Battery Capacitor Circuit

A circuit for charging a battery combined with a capacitor includes a power supply adapted to be connected to the capacitor, and the battery. The circuit includes an electronic switch connected to the power supply. The electronic switch is responsive to switch between a conducting state to allow current and a non-conducting state to prevent current flow. The circuit includes a control device connected to the switch and is operable to generate a control signal to continuously switch the electronic switch between the conducting and non-conducting states to charge the battery.

Stuart, Thomas A.↗

Software Control Program For Transportable Microgrid State-of-charge Balancing And Frequency Stability Controls

A deterministic state-of-charge (SOC) balancing approach software control code is introduced as an integral secondary management to primary control layer of an islanded small microgrid or nanogrid system made up of multiple grid-forming inverter/battery/solar combination systems, where each set of batteries with each inverter are on independent DC buses (i.e. non-paralleled on the DC sides). A DERMS-level control approach, algorithm and automation controller program was developed to improve coordination and enable microgrid asset compliance and SOC balancing, enabling provision of a system-level power stability support architecture, load support, and asset scalability. The architecture is configured to treat each unit or micro/nano-grid as a node in a microgrid network, allowing for autonomous DERMS control regarding load and SOC balancing and power stability. As the network grows with the addition of units, greater coordination efforts may be required. The ideal small network microgrid ranges from 2-10 inverter/battery units before additional control parameters must be considered in the existing architecture. The control approach focuses on a deterministic state-of-charge analysis as the primary level control process followed by a secondary control loop using a forced frequency-watt droop strategy to conform off-the-shelf components into behaving under a leader-follower configuration. Adopting this control scheme has been shown to allow for a balanced, unit-coordinated microgrid network, enabling stable power flow. The deterministic state-of-charge approach is introduced as an integral primary control layer of an islanded small network microgrid. A standard strategy for SOC balancing is implementing a battery management system (BMS) to control SOC on the DC side. An alternative approach is to determine how to coordinate sending and receiving power on the AC side with multiple units. The latter approach assesses all the integrated units in the microgrid network. Once the individual units are identified, further system data is required to calculate each unit's total kWh, provided information about its capability to supply or consume kWh and availability. The secondary control layer in the multi-layered small network microgrid methodology uses the primary layer’s decision to initiate frequency setpoint changes, initializing the SOC balancing. The secondary control layer considers numerous system-dependent variables to enable a charging and discharging profile based on adjustable frequency setpoints. The combined architecture will result in stable, coordinated power flow enhancing an AC microgrid's functionalities.

Myers, KurtS [Idaho National Laboratory (INL), Ida↗