Search NASA⌕ Search

SEARCH · Search NASA

Results for “battery voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Multimission modular spacecraft parallel battery tests

Acceptance test data included: voltage profiles; pressure increase or decrease; and response of the third electrode cell. A softening of the voltage profile was revealed, as well as a lowering of the discharge profile and a 10 percent loss of capacity over a 0 to 20 C temperature range.

Tasevoli, M.↗

Effect of KOH concentration and anions on the performance of Ni-H2 battery positive plate

The capacity and voltage behavior of electrochemically impregnated sintered nickel positive plates was examined by galavanostatic charging; and discharging in a flooded electrolyte cell. Three different concentrations of KOH (40 percent, 31 percent, and 26 percent) and 31 percent KOH containing dissolved nitrate, sulfate or silicate were investigated. The end of charge voltage at C/10 charge and at 10 C showed the following order: 40 percent KOH is greater than 31 percent KOH alone and in the presence of the anions greater than 26 percent KOE. The middischarge voltage at C/2 discharge was higher in 26 percent KOH, almost the same for 31 percent KOH with and without the added contaminants and much lower for 40 percent KOH. The plate capacity was marginally affected by cycling in all cases except for 40 percent KOH where the capacity declined after 1000 cycles at 80 percent DOD. At the end of cycling the plate tested in the presence of sulfate and silicate experienced measurable weight loss as a result of active material extrusion. Cyclic voltammetry of miniature electrodes in 31 percent KOH showed that the second oxidation peak that corresponds to the formation of a different phase of oxidized Ni has a lower peak current at -5 C compared to 25 C and oxygen evolution occurs a higher potential at -5 C. The reduction peak (discharge reaction) is more polarized at 25 C compared to -5 C. The presence of silicate alters the potentials only marginally. The implications of these results in plate treatment and low temperature operation are discussed.

Vaidyanathan, H.↗

The performance and efficiency of four motor/controller/battery systems for the simpler electric vehicles

A test and analysis program performed on four complete propulsion systems for an urban electric vehicle (EV) is described and results given. A dc series motor and a permanent magnet (PM) motor were tested, each powered by an EV battery pack and controlled by (1) a series/parallel voltage-switching (V-switch) system; and (2) a system using a pulse width modulation, 400 Hz transistorized chopper. Dynamometer tests were first performed, followed by eV performance predictions and data correlating road tests. During dynamometer tests using chopper control; current, voltage, and power were measured on both the battery and motor sides of the chopper, using three types of instrumentation. Conventional dc instruments provided adequate accuracy for eV power and energy measurements, when used on the battery side of the controller. When using the chopper controller, the addition of a small choke inductor improved system efficiency in the lower duty cycle range (some 8% increase at 50% duty cycle) with both types of motors. Overall system efficiency rankings during road tests were: (1) series motor with V-switch; (2) PM motor with V-switch; (3) series motor with chopper; and (4) PM motor with chopper. Chopper control of the eV was smoother and required less driver skill than V-switch control.

Shipps, P. R.↗

Testing of the Eagle-Picher nickel-iron, the Globe ISOA lead-acid, and the Westinghouse nickel-iron battery subsystems in an electric-vehicle environment

Three full size developmental batteries were tested with electric vehicles; two nickel-iron batteries and a lead-acid battery. Constant speed and driving schedule tests were done on a chassis dynamometer. Several aspects of battery performance were evaluated for capacity, recharge efficiency, voltage response, and self discharge. Each of these three batteries exhibited some strengths and some weaknesses.

Hewitt, R.↗

Online Prediction of Battery Discharge and Estimation of Parasitic Loads for an Electric Aircraft

Predicting whether or not vehicle batteries contain sufficient charge to support operations over the remainder of a given flight plan is critical for electric aircraft. This paper describes an approach for identifying upper and lower uncertainty bounds on predictions that aircraft batteries will continue to meet output power and voltage requirements over the remainder of a flight plan. Battery discharge prediction is considered here in terms of the following components; (i) online battery state of charge estimation; (ii) prediction of future battery power demand as a function of an aircraft flight plan; (iii) online estimation of additional parasitic battery loads; and finally, (iv) estimation of flight plan safety. Substantial uncertainty is considered to be an irremovable part of the battery discharge prediction problem. However, high-confidence estimates of flight plan safety or lack of safety are shown to be generated from even highly uncertain prognostic predictions.

Battery Discharge Prediction↗

NASA/GSFC Testing of Li-Ion Cells: Update

This viewgraph paper presents a report on the ongoing testing of Lithium Ion (Li-Ion) cells. Characterizes cells according to capacity, self-discharge, and mid-discharge voltage. Determines the cycling performance of Li-Ion cells as batteries according to number of cycles, charge voltage, and temperature.

Vaidyanathan, Hari↗

Engineering and Abuse Testing of Panasonic Lithium-Ion Battery and Cells

This viewgraph presentation reviews the performance testing of Lithium Ion batteries and cells under different conditions of charge and discharge. The tests show that the 0.5 C rate of charge and discharge might be the ideal condition for long term cycling. It reviews the issues of overcharge and overdischarge of the cells. The cells and the battery have adequate protection under both conditions to prevent any catastrophic occurrences. Temperatures above 150 C are required to vent the cells or cause a thermal runaway, Since this situation is non-credible in the cabin of the Space Shuffle or ISS this should not pose a problem. The presentation includes graphs and charts showing the charge and discharge capacities of the battery and also the current and voltage profiles. A view of a circuit board which contains the controlling mechanism for the battery is also shown.

Jeevarajan, Judith A.↗

Evaluation of Cycle Life and Characterization of YTP 45 Ah Li-Ion Battery for EMU

Li-ion batteries, with longer cycle life and higher energy density features, are now more and more attractive and applied in multiple fields. The YTP 45 Ah Li-ion battery has been evaluated here and may be employed in EMU in the future. Evaluations were on: (1) Cycle life tests - 500 cycles total (completed 40 cycles in simulated shuttle use mode and 460 cycles in an accelerated use mode, and recorded differential voltage of individual cell in battery); (2) Characterization test - discharge capacity measurement in environment temperature of -10, 25, 50 C before and after 500 cycles; and (3) Thermal testing - charge and discharge at 50 C and -10 C before and after 500 cycles. The battery showed less than a 9% drop of initial discharge capacity and energy within 500 cycles with 475 cycles 59% DOD plus 25 cycles 100% DOD. The EOD voltage ranged from 16.0 to 18.0 V, which fits the requirement for operating the EMU.

Deng, Yi↗

Li-ion rechargeable batteries on Mars Exploration Rovers

Lithium-ion batteries have contributed significantly to the success of NASA's Mars Rovers, Spirit and Opportunity that have been exploring the surface of Mars for the last two years and performing astounding geological studies to answer the ever-puzzling questions of life beyond Earth and the origin of our planets. Combined with the triple-junction solar cells, the lithium-ion batteries have been powering the robotic rovers, and assist in keeping the rover electronics warm, and in supporting nighttime experimentation and communications. The use of Li-ion batteries has resulted in significant benefits in several categories, such as mass, volume, energy efficiency, self discharge, and above all low temperature performance. Designed initially for the primary mission needs of 300 cycles over 90 days of surface operation, the batteries have been performing admirably, over the last two years. After about 670 days of exploration and at least as many cycles, there is little change in the end-of discharge (EOD) voltages or capacities of these batteries, as estimated from the in-flight data and corroborated by ground testing. Aided by such impressive durability from the Li-ion batteries, both from cycling and calendar life stand point, these rovers are poised to extend their exploration well beyond two years. In this paper, we will describe the performance characteristics of these batteries during launch, cruise phase and on the surface of Mars thus far.

litium ion batteries↗

Earth Radiation Budget Satellite (ERBS) orbiting profiles and Ni-Cd use

The Earth Radiation Budget Satellite (ERBS) is one of the more recently launched satellites of the Goddard Space Flight Center. The flight data of the two 50 Ah NASA standard batteries that are being flown on the ERBS are presented. Trend characteristics of the batteries were collected over a period of two years. The parameters that were trended are: the battery end-of-discharge voltage, time in peak power track, and time in constant current mode. All were plotted versus mission elapsed time. The slopes exhibited by the trended parameters indicate no adverse trends that would signify any appreciable degradation in the batteries.

Enciso, Marlon L.↗

NASA Tech Briefs, March 2006

Topics covered include: Medical Signal-Conditioning and Data-Interface System; Instruments for Reading Direct-Marked Data-Matrix Symbols; Processing EOS MLS Level-2 Data; Ground Processing of Data From the Mars Exploration Rovers; Estimating Total Electron Content Using 1,000+ GPS Receivers; NASA Solar Array Demonstrates Commercial Potential; Improved Control of Charging Voltage for Li-Ion Battery; Programmable Pulse-Position-Modulation Encoder; Wavelength-Agile External-Cavity Diode Laser for DWDM; Pattern-Recognition Processor Using Holographic Photopolymer; Submicrosecond Power-Switching Test Circuit; Three-Function Logic Gate Controlled by Analog Voltage; Integrated System for Autonomous Science; Montage Version 3.0; Utilizing AI in Temporal, Spatial, and Resource Scheduling; Satellite Image Mosaic Engine; Architecture for Control of the K9 Rover; HFGMC Enhancement of MAC/GMC; Automated Activation and Deactivation of a System Under Test; Cleaning Carbon Nanotubes by Use of Mild Oxygen Plasmas; Generating Aromatics From CO2 on Mars or Natural Gas on Earth; Attaching Thermocouples by Peening or Crimping; Heat Treatment of Friction-Stir-Welded 7050 Aluminum Plates; Generating Breathable Air Through Dissociation of N2O; High-Performance Scanning Acousto-Ultrasonic System; Correction for Thermal EMFs in Thermocouple Feedthroughs; Using Quasiparticle Poisoning To Detect Photons; Estimating Resolution Lengths of Hybrid Turbulence Models; Education and Training Module in Alertness Management; Cargo-Positioning System for Next-Generation Spacecraft; Micro-Imagers for Spaceborne Cell-Growth Experiments; Holographic Solar Photon Thrusters; Plasma-Based Detector of Outer-Space Dust Particles; and Generation of Data-Rate Profiles of Ka-Band Deep-Space Links.

Source record↗

Orbiting solar observatory battery and power design

The OSO-1 represents a recent vintage satellite, or more recent design satellite. A summary of the battery design used on OSO-1 is presented. The temperature effects on voltage and charging-discharging of the battery system are discussed.

Ford, F. E.↗

Special Test Methods for Batteries

Various methods are described for measuring heat generation in primary and secondary batteries as well as the specific heat of batteries and cell thermal conductance. Problems associated with determining heat generation in large batteries are examined. Special attention is given to monitoring temperature gradients in nickel cadmium cells, the use of auxiliary electrodes for conducting tests on battery charge control, evaluating the linear sweep of current from charge to discharge, and determining zero current voltage. The fast transient behavior of batteries in the microsecond range, and the electrical conductance of nickel sinters in the thickness direction are also considered. Mechanical problems experienced in the vibration of Ni-Cd batteries and tests to simulate cyclic fatigue of the steel table connecting the plates to the comb are considered. Methods of defining the distribution of forces when cells are compressed during battery packaging are also explored.

Gross, S.↗

Full-charge indicator for battery chargers

A full-charge indicator for battery chargers, includes a transistor which is in a conductive state as long as charging current to the battery is not less than a level which indicates that the battery did not reach full charge. When the battery reaches full charge, a voltage drop in a resistor in the charging current path is not sufficient to maintain the transistor in a conducting state, and therefore it is switched off. When this occurs an LED is turned on, to indicate a full charge state of the battery. A photocoupler together with a photocoupler transistor are included. When the transistor is off, the photocoupler activates the photocoupler transistor to shunt out a resistor, thereby reducing the charging current to the battery to a float charging current and prevent the battery from being overcharged and damaged.

Cole, Steven W.↗

A Multiphysics Study to Improve Specific Energy of Primary Batteries for Low Temperature Operation for Deep Space Missions

Several lander missions on the outer planets such as Europa, Enceladus, and Titan require electrical power to operate scientific and communication equipment. The traditional power generation methods, such as a photovoltaic array, are not feasible as their efficiency drops significantly at these vast distances. The novel radioisotope power systems are not practical today based on current lander designs and the effectiveness of these systems. To perform in situ science on distant planets, a high specific energy battery (>700 Wh/kg) needs to operate for about 480 hours under cold temperatures (-40C or 0C) [1]. While a primary battery such as Li-CFx can provide high specific energy at room temperature, its specific capacity decreases significantly at low temperatures. One of the causes for this drop is low ion and electrical conductivity, and slower reaction kinetics. Slower transport and facile kinetics lead to an increase in the battery’s resistance and higher voltage drops during the cell operation, thus reducing specific capacity. Both the transport and kinetics show a strong dependence on temperature. Thus, a small temperature rise can lead to an increase in the reaction rate and ion conductivity; since the temperature, cell resistance, and specific capacity are interdependent. A conventional battery model accounts for ohmic, thermodynamic, and, electrochemical, and chemical decomposition heating. The ohmic heating can be controlled by designing a resistive microstructure and varying the ratios of the active materials [2]. The kinetics can be improved by increasing the surface area, reducing the particle size, or adding a catalyst. These parameters are often optimized to achieve high specific energy at room temperatures. A similar optimization study is not available at low temperatures and for a primary (high specific energy) battery. For this presentation, we will explore the effect of geometrical, microstructural, and material properties on optimal specific capacity at low temperatures through multiphysics simulations. The ion transport resistance depends on the porosity and the tortuosity of an electrode and the separator.

M. Mehta↗

Advances in the design of common pressure vessel nickel hydrogen batteries for aerospace applications

Over 7000 low-earth-orbit (LEO) cycles were demonstrated on a full-size aerospace common pressure vessel (CPV) prototype. The battery demonstrated the capability of the basic CPV design to meet the life and reliability requirements of aerospace missions. Subsequent design modifications have been employed to address the shortcomings of the original design and several new prototypes have been fabricated. These include a 12-cell 125 amp-hour geosynchronous earth-orbit (GEO) battery and a 22-cell 10.5 amp-hour LEO battery. Cells for an 80-cell battery intended to demonstrate the high voltage capability of the CPV design have also been fabricated. In addition, assembly of a 20-cell aircraft starting battery prototype is in progress, and testing of a group of 12-volt, 160 amp-hour terrestrial batteries is continuing.

Zagrodnik, Jeffrey P.↗

Unique battery reconditioning cycle for RCA's geostationary satellites and its applicability for low Earth satellite

Six (6) geostationary spacecraft, manufactured by RCA Astro, are presently operating in orbit. All of their batteries are performing well. They all contain unique battery reconditioning circuitry, permitting individual cell reconditioning to practically zero volts without the danger of cell reversal. This reconditioning is performed just prior to start of each eclipse season. This technique has maintained the battery's end-of-discharge voltage with mission life. The oldest operating RCA Astro geostationary spacecraft, Satcom F1 and F2, have now completed almost 7 and 6-3/4 years in orbit, respectively. Their battery performance, reported herein, show that a major milestone in the mission longevity of nickel-cadmium batteries has heen achieved. Low earth orbit test data show a long lasting effect of maintaining end-of-discharge voltages for nickel cadmium cells using periodic reconditioning. The unique RCA light-weight reconditioning circuitry can accomplish a quick reconditioning and prevent cell reversal. Reconditioning, thus, has the potential for extending mission life of geostationary as well as low earth orbit spacecraft, when two or more batteries are present.

Gaston, S. J.↗

Modeling taper charge with a non-linear equation

Work aimed at modeling the charge voltage and current characteristics of nickel-cadmium cells subject to taper charge is presented. Work reported at previous NASA Battery Workshops has shown that the voltage of cells subject to constant current charge and discharge can be modeled very accurately with the equation: voltage = A + (B/(C-X)) + De to the -Ex where A, B, D, and E are fit parameters and x is amp-hr of charge removed during discharge or returned during charge. In a constant current regime, x is also equivalent to time on charge or discharge.

Mcdermott, P. P.↗