The trend in neutron sciences is toward integrating compact, high-brightness moderators into new or upgraded facilities. Transporting neutrons from the source to the sample position with a phase-space distribution tailored to specific requirements is crucial to leverage high source brilliance. Here we have investigated four guide concepts using Monte Carlo ray tracing simulations: Montel beamline with nested Kirkpatrick–Baez mirrors, curved-tapered beamline with a bender and straight sections, straight-elliptical beamline, and curved-elliptical beamline. The straight-elliptical (curved-elliptical) beamline features two half-ellipse guides connected by a straight (non-straight) guide section. The neutron transport efficiency and phase space homogeneity have been quantitatively compared. Our results show that the straight-elliptical beamline performs best because of few neutron bounces on the guide surface with small reflection angles, minimizing flux loss. The Montel beamline provides the best spatial confinement of neutrons within the desired region; however, there is a high thermal-neutron loss due to large reflection angles. The curved-tapered beamline suffers from significant flux loss due to high bounces, and it shows a non-uniform angular distribution related to broad ranges of bounces and reflection angles. The non-straight guide section of the curved-elliptical beamline increases the phase space inhomogeneity, leading to a spatially non-uniform beam profile. The results apply to general neutron instruments that require transporting thermal and cold neutrons from a compact, high-brilliance moderator to the sample location with a moderate phase-space volume.
Supported metal clusters are widely used in catalysis for many important reactions. To understand the catalytic properties, in situ/operando characterization techniques, such as X-ray absorption spectroscopy (XAS), provide essential details of the size, shape, and chemical composition of the cluster and the nature of the active sites. New-generation synchrotrons combined with focusing beamlines provide high-flux-density X-rays for improved detection sensitivity as well as higher time and spatial resolution. Understanding the effects of a high-flux-density X-ray beam on the catalyst during the actual measurement, whether XAS or another synchrotron-based technique, is crucial. This is especially important for in situ and operando studies where both the high flux density and reaction conditions can affect the catalyst structure. In this work, we investigated the effect of the flux density on rhodium clusters supported on Al 2 O 3 at two different beamlines: National Synchrotron Light Source II beamline 08-ID and Stanford Synchrotron Radiation Light Source (SSRL) beamline 4-1. We show that the higher flux density at beamline 08-ID causes the reduction of the highly dispersed RhO x /Al 2 O 3 catalyst, even at room temperature. Additionally, exposure to the higher flux density X-rays at beamline 08-ID during in situ reduction results in significant agglomeration of the Rh clusters. The final size of the Rh nanoparticles reduced at 310 °C is equivalent to that of particles formed after the reduction at 600–650 °C in the absence of the beam. Significant beam-induced reduction and agglomeration is also shown for Ni supported on beta zeolite during in situ reduction at an intermediate-flux-density beamline 9-3 at SSRL, indicating that beam-induced changes in heterogeneous catalysts could be common at intermediate- and high-flux-density beamlines. We provide precautions and recommendations for detecting and minimizing beam damage during in situ/operando XAS measurements.
The Advanced Photon Source (APS) has been upgraded with a multi-bend achromat lattice, achieving significantly reduced electron beam emittance and enhanced X-ray coherence. Precise characterization of these properties is essential for optimizing beamline performance and enabling new experiments that take full advantage of the upgraded source. We report on measurements of source size and transverse coherence properties using grating interferometry at two beamlines: the APS 3-ID-B undulator beamline and the 1-BM-B bending magnet beamline. The results confirm the world-record horizontal emittance of the upgraded APS below 30 pm rad and validate the theoretical design parameters. We further investigate the impact of optical aberrations and mechanical vibrations at the 12-ID-C beamline on coherence preservation. These measurements establish a benchmark for future beamline enhancements and demonstrate the effectiveness of grating interferometry for high-precision beam characterization. Our findings provide critical insights into synchrotron beam dynamics, coherence degradation mechanisms, and strategies for optimizing beamline X-ray optics at next-generation light sources.
At the Department of Energy’s Oak Ridge National Laboratory, the Second Target Station (STS) beamline sources for preliminary design have been used to perform a shielding analysis of the bunker. The simulations in this report used the ST11 beamline source, primarily the ST11 neutron source, because that source provides conservative prompt total dose rate estimates for all beamlines. Prompt total dose rates (i.e., neutron plus photon dose rates when the beam is on) were calculated on top of the bunker roof, outside the bunker wall, and in the basement below the bunker and instrument floor. Design changes were made to ensure the prompt total dose rate in these areas does not exceed 0.25 mrem/h. This report documents the required shielding thicknesses to meet this dose rate limit. There is one exception to this: for a combination of open and closed beamlines, the prompt total dose rate outside the bunker across from the closed beamline, where there is less shielding due to the lack of beamline shielding, slightly exceeds 0.25 mrem/h. A future analysis will document the shielding modifications required to reduce the calculated prompt total dose rates for this configuration to less than 0.25 mrem/h once more details regarding the STS high density concrete density and composition are known. Finally, prompt total dose rates inside the bunker were simulated. The results of this simulation show that the majority of prompt total dose rate in the bunker is due to neutrons, and a few percent of the total is caused by secondary photons created by the neutrons. The contribution to prompt total dose rate inside the bunker by the primary photons that enter each beamline from the target/moderator area is at least two orders of magnitude less than the neutron contribution. This means prompt total dose rate contributions due to primary photons inside and outside the bunker can be neglected.
Analytical tools and models have been developed as a starting point for directly assessing dose in the Annular Core Research Reactor Facility (ACRRF) due to reactor operation. Key results include peak dose along the Central Cavity (CC) centerline (beamline) at the cavity level, dose throughout the High-Bay (HB), and dose on the facility roof for partially-shielded reactor operation where the 4” insert is removed from the CC Shield Plug (SP). Model results in the beamline are benchmarked against measured doses from passive dosimetry evaluations. Personnel total (neutron and gamma) dose in the ACRRF HB is calculated using Monte Carlo N-Particle (MCNP). Various CC and SP configurations are analyzed, including unshielded (no SP) and partially shielded (SP installed but 4” insert removed). Novel application of Variance Reduction (VR) techniques, namely the Surface Source Write (SSW) and Surface Source Read (SSR) capabilities in MCNP, enable impressive resolution (in a Monte Carlo modeling sense) of dose throughout much the facility. The VR techniques reduce stochastic error for challenging tallies, with more advanced techniques explored in the companion to this report (Part B) [1]. Supplementary studies (including a verification analysis) and pedagogic evaluations in Part B involve neutron spectra, angular distributions, and the dose impact of facility characteristics. With the SP 4” insert removed and the Lead-Boron (44”) Bucket (LB–44) in the reactor cavity, Total Effective Dose (TED) within the CC beamline is ≈140 rem per 300 MJ of reactor yield (or 3900 rem per hour at 100% Steady-State (SS) power). With no SP (unshielded) and a Free-Field (FF) cavity, TED within the beamline is ≈610 rem per 300 MJ (or 17000 rem per hour at 100% SS power). Due to the predicted collimation of radiation by the reactor pool (and partial SP, if present), beamline dose is much greater than the scattered radiation field surrounding the cavity and reactor tank. Comparisons are made to beamline dosimetry measurements to validate the model. Model predictions agree reasonably well (⪅10%) with measured quantities of neutron fluence, gamma fluence, and spectral metrics. Away from the beamline, comparisons made to previous dose measurements in the HB agreement within an order of magnitude.
The Activated Materials Laboratory (AML), located in the Long Beamline Building of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL), provides a centralized radiological capability for preparing, handling, and supporting synchrotron experiments on activated materials. As a Nuclear Science User Facilities (NSUF) partner facility, the AML enables the receipt of radioactive shipments, open-form sample handling, encapsulation, transport of specimens to and from APS beamlines, and experimentation with dedicated equipment. The partnership includes the APS 1-ID and 20-ID beamlines, which provide high-energy x-ray scattering, tomography, and diffraction microscopy techniques for ex-situ, in-situ, and grainresolved three-dimensional (3D) characterization. All samples supported through the AML and partner beamlines must meet radiological limits of less than 100 mrem/h at 30 cm. This FY26 progress report summarizes the first full year of AML operations as an NSUF partner facility and highlights progress in both user support and capability development. By the end of FY26, the AML had received a total of 10 NSUF-awarded projects, including 2 Consolidated Innovative Nuclear Research (CINR), 7 Rapid Turnaround Experiment (RTE), and 1 Super RTE projects. Beamtime was fully delivered for 3 RTE projects and partially delivered for 1 CINR project, demonstrating successful workflows for receipt, encapsulation, beamline transfer, and radiological experiment execution. These efforts demonstrated safe radiological experiments at APS beamlines for samples with dose rates above the historical 5 mrem/h threshold and now up to 100 mrem/h at 30 cm, marking an important milestone for neutron-irradiated materials research. During FY26, the AML also expanded its experimental capabilities. A Psylotech xTS load frame with in-grip rotation was deployed for room-temperature mechanical testing with threedimensional x-ray characterization during interrupted loading. A Linkam TS1500V vacuum heater was commissioned for thermally driven studies, and temperature calibration experiments were performed to establish specimen-relevant thermal profiles. In parallel, a customized split-tube furnace for high-temperature mechanical testing entered commissioning, and initial work began on robotic sample handling to reduce worker dose and improve operational efficiency. Data workflow and beamline operations continued to mature. Together, these developments demonstrate that the AML is becoming a unique national resource for safe, efficient, and scientifically advanced characterization of activated materials at the APS.
The Advanced Photon Source (APS) at Argonne National Laboratory (ANL) was designed and built as one of the first large 3rd generation synchrotrons operated at 7 GeV. The United States Department of Energy (DOE) Office of Science funded the construction and continues to fund the operation of this national facility. Furthermore, the beamlines were originally operated by Collaborative Access Teams (CAT), which allowed a strong involvement of research institutes, universities, and industry. Today 43 of 68 beamlines are operated by the X-ray Science Division (XSD) and 35 beamlines are directly funded by the DOE Office of Science. The APS became operational in 1995, and was planned right from the beginning with 4 beamlines dedicated to high-energy x-rays above 40 keV: 1-ID designed to study engineering materials science, 6-ID-D for magnetism and condensed matter research, 11-ID-B dedicated to magnetic Compton scattering using an Elliptical Multipole Wiggler, and 11-ID-C for materials science and condensed matter physics. These stations were later joined by the bending magnet beamlines 6-BM for white beam studies and 17-BM for rapid powder diffraction. CAT operated beamlines such as 15-ID for crystallography or 16-ID for high-pressure studies also use the high-energy x-ray regime frequently. The program in Compton scattering ended in 2004 and the wiggler was replaced by an undulator. 11-ID-B became the first dedicated station for Pair Distribution Function (PDF) Analysis.
The NSLS-II network and computing infrastructure has been significantly updated recently. The re-IP process in 2020-2021 enabled the NSLS-II network to be routable to the rest of the BNL campus. Then, standardization of the operating systems and deployment procedures helped to deliver a consistent environment to workstations and servers used by all NSLS-II beamlines. In particular, the RedHat Enterprise Linux 8 was deployed to 700+ machines using the RedHat Satellite infrastructure management product, and all critical services (IOCs, databases, etc.) were migrated to the new OS. NFS users’ home directories are consistent across all of the machines, which eliminates the need for the individual configuration of the user environment on each host. The standard suite of software packages is available to the beamline staff and users, which includes the system packages (deployed via RPM) as well as the conda environments for data acquisition and analysis. Security measures were implemented to comply with the industry standards, which include multi-factor authentication (using Duo), secure screen lock for the beamline machines, and advanced access control to the experimental data that is stored in shared central storage available on all hosts. These major enhancements facilitated sharing the experimental data (currently for a number of selected beamlines, with a plan to extend it to the whole facility in the nearest future) with the users via an externally facing JupyterHub instance. The beamlines keep using the Bluesky data acquisition framework to orchestrate their experiments, and the new infrastructure enabled them to use a next-generation data access library called tiled.
X-ray absorption spectroscopy (XAS) beamlines worldwide are steadily increasing their emphasis on full photon-in/photon-out spectroscopies, such as resonant inelastic X-ray scattering (RIXS), resonant X-ray emission spectroscopy (RXES) and high energy resolution fluorescence detection XAS (HERFD-XAS). In such cases, each beamline must match the choice of emission spectrometer to the scientific mission of its users. Previous work has recently reported a miniature tender X-ray spectrometer using a dispersive Rowland refocusing (DRR) geometry that functions with high energy resolution even with a large X-ray spot size on the sample. This instrument has been used in the laboratory in multiple studies of non-resonant X-ray emission spectroscopy using a conventional X-ray tube, though only for preliminary measurements at a low-intensity microfocus synchrotron beamline. This paper reports an extensive study of the performance of a miniature DRR spectrometer at an unfocused wiggler beamline, where the incident monochromatic flux allows for resonant studies which are impossible in the laboratory. Here, the results support the broader use of the present design and also suggest that the DRR method with an unfocused beam could have important applications for materials with low radiation damage thresholds and that would not survive analysis on focused beamlines.
Free-electron-laser-based beamlines utilize fully coherent laser pulses with extremely narrow bandwidth allowing direct use of X-rays without monochromators. This could be very beneficial for all users of current and future fourth-generation diffraction-limited synchrotron light sources (DL-SLSs) who need narrowband full-coherence high-brightness X-ray pulses. Based on our previous finding, i.e. that separating the two stages of echo-enabled harmonic generation (EEHG) with a few extra bending-magnet sections provides an effective way to increase the momentum compaction of chicane 1, one can simultaneously achieve adequate prebunching at extremely high harmonics as well as keep the energy modulation to the ideal minimum. This could open the door for cascaded EEHG, toward fully coherent tender and hard X-ray wavelengths. Built on our compact design of a twin-pulse seeding electron beam with an adjustable delay and timing jitter at the level of a few femtoseconds, a cascaded EEHG can be implemented, which includes two EEHG beamlines, where the radiation pulse generated by the first beamline with harmonic $h$ 1 could be used as the input seed laser pulse to the second beamline with harmonic $h$ 2 . Hence, the second radiator could potentially reach very high harmonics [$h$ = $h$ 1 (20)$h$ 2 (25–100)] from 500 to 2000, corresponding to tender and hard X-ray wavelengths. It is demonstrated that the cascaded EEHG scheme is compatible with almost any current or planned fourth-generation DL-SLS, with significant benefits for space-limited storage rings in particular. The main advantage is that this scheme requires almost no change of the storage-ring lattice and is fully compatible with other beamlines. Current proposals for rings with much longer straight sections would add self-amplified spontaneous emission as another viable option for storage-ring-based free-electron lasers.
We present an integrated system that combines advanced wavefront diagnostics with artificial intelligence (AI) to automate and optimize X-ray optics at synchrotron beamlines. This system couples real-time wavefront sensing with AI-driven control algorithms to achieve precise beam alignment, stabilization, and performance optimization. A key feature is the use of multi-fidelity transfer learning, which enables knowledge gained from both real-world beamline optimizations and ultra-realistic digital twin simulations to be effectively applied to in situ optimization. By leveraging multi-objective bayesian optimization, the system continuously refines its performance, reducing optimization time and minimizing the need for manual adjustments. Designed for seamless deployment, it operates with existing beamline hardware and provides an intuitive graphical interface. Initial deployments at the advanced photon source beamlines have demonstrated its ability to enhance beam stability, improve reproducibility, and significantly streamline alignment procedures. This AI-enhanced control framework represents a significant step toward fully autonomous beamline operation in next-generation synchrotron facilities.
AC local bumps of the beam orbit developed at NSLS-II are successfully used for accelerator physics studies. Recently, AC bumps localized at light-generating insertion devices (ID) are considered by NSLS-II beamline scientists as a possible user operation mode. The AC perturbation of the X-ray beam in a controllable way will provide a possibility to investigate the effects of the source size and temporal evolution on the coherence of the photon beam. It also can be used to average out the spatial non-uniformity of the beam intensity caused by the beamline optics. Before the implementation of the AC orbit bumps into user operations, we must investigate if the electron beam perturbation affects the other beamlines. A proof-of-principle experiment was carried out: an AC bump was created and well localized in the CSX and/or FXI beamline. Transparency of this AC bump to other beamlines has been studied, the results are discussed.
Particle accelerators are vital tools in physics, medicine, and industry, requiring precise tuning to ensure optimal beam performance. However, real-world deviations from idealized simulations make beam tuning a time-consuming and error-prone process. In this work, we propose an explanation-driven framework for providing actionable insight into beamline operations, with a focus on the injector beamline at the Continuous Electron Beam Accelerator Facility (CEBAF). We represent beamline configurations as heterogeneous graphs, where setting nodes represent elements that human operators can actively adjust during beam tuning, and reading nodes passively provide diagnostic feedback. To identify the most influential setting nodes responsible for differences between any two beamline configurations, our approach first predicts the resulting changes in reading nodes caused by variations in settings, and then learns importance scores that capture the joint influence of multiple setting nodes. Experimental results on real-world CEBAF injector data demonstrate the framework’s ability to generate interpretable insights that can assist human operators in beamline tuning and reduce operational overhead.
A sudden loss of vacuum can be catastrophic for superconducting particle accelerators. In such an event, air leaks into the liquid-helium-cooled accelerator beamline tube and condenses on its inner surface, causing rapid boiling of the helium and dangerous pressure build-up. Understanding the coupled heat and mass transfer processes is important for the design of the beamline cryogenic system. Our past experimental study on nitrogen gas propagating in a copper tube cooled by normal liquid helium (He I) has revealed a nearly exponential slowing down of the gas front. A theoretical model that accounts for the interplay of the gas dynamics and the condensation was developed, which successfully reproduced various key observations. However, since many accelerator beamlines are actually cooled by superfluid helium (He II) in which the heat transfer is via a non-classical thermal counterflow mode, we need to extend our work to the He II cooled tube. This paper reports our systematic measurements using He II and the numerical simulations based on a modified model that accounts for the He II heat-transfer characteristics. By tuning the He II peak heat-flux parameter in our model, we have reproduced the observed gas dynamics in all experimental runs. The fine-tuned model is then utilized to reliably evaluate the heat deposition in He II. Finallly, this work not only advances our understanding of condensing gas dynamics but also has practical implications to the design codes for beamline safety.
We introduce a new style of multileaf collimator which employs rotors with angularly dependent radius to control the masking aperture: a rotor-based multileaf collimator (RMLC). Using a padlock-inspired mechanism, a single motor can set dozens of rotors, i.e. leaves, independently. This is especially important for an ultra-high vacuum (UHV) compatible MLC, since this reduces the number of actuators and vacuum feedthroughs required by more than an order of magnitude. This new RMLC will complement previous work employing a UHV compatible MLC with an emittance exchange beamline to create arbitrarily shaped beams on demand. A feed-forward control system which abstracts away the complexity of the RMLC operation, and is adaptable to real beamline conditions, is discussed and demonstrated in simulation.