At least 181 records · Page 10

An Array of Frequency Selective Bolometers (FSB) for the Spectral Energy Distribution (SPEED) Camera

The SPEED camera is being developed to study the spectral energy distributions of high redshift galaxies using the Heinrich Hertz Telescope (HHT) in Arizona. SPEED requires a small cryogenic detector array of 2x2 pixels with each pixel having four frequency bands in the 150-350 GHz range. Here we describe the development of the detector array of these high efficiency FSBs. The FSB design provides the multi-pixel multi-spectral band capability required for SPEED in a compact stackable array. The SPEED bolometers will use proximity effect superconducting transition edge sensors as their temperature-sensing element allowing for higher levels of multiplexing in future applications.

Silverberg, R. F.↗

Implanted Silicon Resistor Layers for Efficient Terahertz Absorption

Broadband absorption structures are an essential component of large format bolometer arrays for imaging GHz and THz radiation. We have measured electrical and optical properties of implanted silicon resistor layers designed to be suitable for these absorbers. Implanted resistors offer a low-film-stress, buried absorber that is robust to longterm aging, temperature, and subsequent metals processing. Such an absorber layer is readily integrated with superconducting integrated circuits and standard micromachining as demonstrated by the SCUBA II array built by ROE/NIST (1). We present a complete characterization of these layers, demonstrating frequency regimes in which different recipes will be suitable for absorbers. Single layer thin film coatings have been demonstrated as effective absorbers at certain wavelengths including semimetal (2,3), thin metal (4), and patterned metal films (5,6). Astronomical instrument examples include the SHARC II instrument is imaging the submillimeter band using passivated Bi semimetal films and the HAWC instrument for SOFIA, which employs ultrathin metal films to span 1-3 THz. Patterned metal films on spiderweb bolometers have also been proposed for broadband detection. In each case, the absorber structure matches the impedance of free space for optimal absorption in the detector configuration (typically 157 Ohms per square for high absorption with a single or 377 Ohms per square in a resonant cavity or quarter wave backshort). Resonant structures with -20% bandwidth coupled to bolometers are also under development; stacks of such structures may take advantage of instruments imaging over a wide band. Each technique may enable effective absorbers in imagers. However, thin films tend to age, degrade or change during further processing, can be difficult to reproduce, and often exhibit an intrinsic granularity that creates complicated frequency dependence at THz frequencies. Thick metal films are more robust but the requirement for patterning can limit their absorption at THz frequencies and their heat capacity can be high. patterned absorber structures that offer low heat capacity, absence of aging, and uniform, predictable behavior at THz frequencies. We have correlated DC electrical and THz optical measurements of a series of implanted layers and studied their frequency dependence of optical absorption from .3 to 10 THz at cryogenic temperatures. We have modeled the optical response to determine the suitability of the implanted silicon resistor as a function of resistance in the range 10 Ohms/sq to 300 Ohms/sq.

Chervenak, J. A.↗

Absolute response and noise equivalent power of cyclotron resonance-assisted InSb detectors at submillimeter wavelengths

Spectra are presented of the responsivity and noise equivalent power (NEP) of liquid-helium-cooled InSb detectors as a function of magnetic field in the range 20-110 per cm. The measurements are all made using a Fourier transform spectrometer with thermal sources. The results show a discernable peak in the detector response at the conduction electron cyclotron resonance (CCR) frequency for magnetic fields as low as 3 kG. The magnitude of responsivity at the resonance peaks is roughly constant with magnetic field and is comparable to the low-frequency hot-electron bolometer response. The NEP at the peaks is found to be comparable to the best long wavelength results previously reported. For example, NEP = 4.5 x 10 to the 13th W/(square root of Hz) at 4.2 K, 6 kG, and 40 per cm was measured. The InSb CCR will provide a much improved detector for laboratory spectroscopy, as compared with hot electron bolometers, in the 20-100 per cm range.

Brown, E. R.↗

Fundamental Limits on the Imaging and Polarisation Properties of Far-Infrared Detectors

Far-infrared bolometric detectors are used extensively in ground-based and space-borne astronomy, and thus it is important to understand their optical behaviour precisely. We have studied the intensity and polarisation response of free-space bolometers, and shown that when the size of the absorber is reduced below a wavelength, the response changes from being that of a classical optical detector to that of a few-mode antenna. We have calculated the modal content of the reception patterns, and found that for any volumetric detector having a side length of less than a wavelength, three magnetic and three electric dipoles characterize the behaviour. The size of the absorber merely determines the relative strengths of the contributions. The same formalism can be applied to thin-film absorbers, where the induced current is forced to flow in a plane. In this case, one magnetic and two electric dipoles characterize the behaviour. The ability to model easily the intensity, polarisation, and straylight characteristics of electrically-small detectors will be of great value when designing high-performance polarimetric imaging arrays.

Thomas, Christopher N.↗

Proceedings of the Twelfth International Symposium on Space Terahertz Technology

The Twelfth International Symposium on Space Terahertz Technology was held February 14-16, 2001 in San Diego, California, USA. This symposium was jointly sponsored by the National Aeronautics and Space Administration (NASA) and the Jet Propulsion Laboratory, California Institute of Technology. The symposium featured sixty nine presentations covering a wide variety of technical topics relevant to Terahertz Technology. The presentations can be divided into five broad technology areas: Hot Electron Bolometers, superconductor insulator superconductor (SIS) technology, local oscillator (LO) technology, Antennas and Measurements, and Direct Detectors. The symposium provides scientists, engineers, and researchers working in the terahertz technology and science fields to engineers their work and exchange ideas with colleagues.

Mehdi, Imran↗

Selenium immersed thermistor bolometer study

The noise characteristics of thermistor bolometers immersed in layers of arsenic/selenium glass uniform in composition were examined. Using a controlled deposition technique, layers of glass were deposited, thermistor bolometers immersed, and their electrical characteristics measured after various thermal treatments. Markedly improved stability of the detector noise was observed using this new technique.

Rolls, W. H.↗

Neutron transmutation doped Ge bolometers

Some conclusions reached are as follow. Neutron Transmutation Doping (NTD) of high quality Ge single crystals provides perfect control of doping concentration and uniformity. The resistivity can be tailored to any given bolometer operating temperature down to 0.1 K and probably lower. The excellent uniformity is advantaged for detector array development.

Haller, E. E.↗

Tunable Antireflection Layers for Planar Bolometer Arrays

It remains a challenge to obtain high-efficiency coupling of far-infrared through millimeter radiation to large-format detector arrays. The conventional approach of increasing detector coupling is to use reflective backshorts. However, this approach often results in excessive systematic errors resulting from reflections off the backshort edge. An alternate approach to both increasing quantum efficiency and reducing systematics associated with stray light is to place an antireflective coating near the front surface of the array. When incorporated with a resistive layer and placed behind the detector focal plane, the AR coating can serve to prevent optical ghosting by capturing radiation transmitted through the detector. By etching a hexagonal pattern in silicon, in which the sizes of the hexes are smaller than the wavelength of incident radiation, it is possible to fabricate a material that has a controllable dielectric constant, thereby allowing for simple tunable optical device fabrication. To this end, we have fabricated and tested tunable silicon "honeycomb" AR layers and AR/resistive layer devices. These devices were fabricated entirely out of silicon in order to eliminate problems associated with differential contraction upon detector cooling.

Brown, Ari-David↗

Mid-infrared detector development for the Origins Space Telescope

Mid-infrared detector arrays operating from 2.8 to 20 μm are baselined in the design of the Origins Space Telescope Mid-Infrared Spectrometer Instrument. This instrument is designed to detect and measure the spectral signatures of gases of biogenic origin in the atmospheres of exoplanets as they transit their host stars. In order to make these detections, the detector array’s pixels need to have high-signal stability when exposed to a constant flux in multiple time-series integration over a typical transit time of a few hours. With the use of a densified pupil spectrometer design, pointing effects can be mitigated because pointing variations do not displace spectra on the detector and each wavelength of light is averaged over a large number of pixels, giving good spectrophotometric stabilities. The current state-of-the-art detector arrays do not achieve these stabilities, although with a feasible development program this level of performance should be achievable. Three detector technologies are under consideration for this development, HgCdTe arrays, Si:As impurity band conduction arrays, and transition edge super-conductor bolometer arrays. We primarily treat the HgCdTe technology development, but also introduce the paths forward for the other two technologies. After a few years-long investigative programs, a down-select will be undertaken to select the flight technology.

Astronomy↗

Comparing complex impedance and bias step measurements of Simons Observatory transition edge sensors

The Simons Observatory (SO) will perform ground-based observations of the cosmic microwave background (CMB) with several small and large aperture telescopes, each outfitted with thousands to tens of thousands of superconducting aluminum manganese (AlMn) transition-edge sensor bolometers (TESs). In-situ characterization of TES responsivities and effective time constants will be required multiple times each observing-day for calibrating time-streams during CMB map-making. Effective time constants are typically estimated in the field by briefly applying small amplitude square-waves on top of the TES DC biases, and fitting exponential decays in the bolometer response. These so-called “bias step” measurements can be rapidly implemented across entire arrays and therefore are attractive because they take up little observing time. However, individual detector complex impedance measurements, while too slow to implement during observations, can provide a fuller picture of the TES model and a better understanding of its temporal response. Here, we present the results of dark TES characterization of many prototype SO bolometers and compare the effective thermal time constants measured via bias steps to those derived from complex impedance data.

Nicholas F. Cothard↗

A 100 micro Kelvin bolometer system for SIRTF

Progress toward a prototype of 100 mK bolometric detection system for the Space Infrared Telescope Facility (SIRTF) is described. Two adiabatic demagnetization refrigerators (ADR's) were constructed and used to investigate the capabilities necessary for orbital operation. The first, a laboratory ADR, demonstrated a hold time at 0.1 K of over 12 hours, with temperature stability approx. 3 micro-K RMS achieved by controlling the magnetic field. A durable salt pill and an efficient support system have been demonstrated. A second ADR, the SIRTF flight prototype, has been built and will be flown on a balloon. Techniques for magnetic shielding, low heat leak current leads, and a mechanical heat switch are being developed in this ADR. Plans for construction of 100 mK bolometers are discussed. Three important cosmological investigations which will be carried out by these longest wavelength SIRTF detectors are described.

Bernstein, G. M.↗

Fabrication of Phononic Filter Structures for Far-IR/sub-mm Detector Applications

A photon noise limited sub-mm/far-IR cold telescope in space will require detectors with noise equivalent power (NEP) less than 1x10-19W/Hz1/2for imaging applications and at least an order of magnitude lower for spectroscopic studies. The detector NEP can be reduced by lowering the operation temperature and improving the thermal isolation between the bolometer and a heat bath. We report on the fabrication of membrane isolated transition edge sensor bolometers incorporating compact (<50 μm) thermal isolation beams based on phononic filters. Phononic filters are created by etching quasi-periodic nanoscale structures into supporting thermo-mechanical beams. The cross-sectional dimensions of the etched features are less than the thermal wavelength at the operating temperature, enabling coherent phonon transport to take place in one dimension. The phonon stop-band can be tuned by adjusting the scale of the quasi-periodic structures. Cascading multiple filter stages can increase bandwidth and provide improved thermal isolation similar to the function of a multi-stage electrical filter. We describe the fabrication of AlMn based transition edge sensor bolometers on silicon and silicon nitride membranes isolated by one-and two-dimensional phononic filters. The phononic filters are patterned through electron beam lithography and isolated with deep reactive ion etching.

Phononic↗

Electromagnetic Considerations for Planar Bolometer Arrays in the Single Mode Limit

Filled arrays of planar bolometers are finding astronomical applications at wavelengths as long as several millimeters. In an effort to keep focal planes to a reasonable size while maintaining large numbers of detectors, a common strategy is to push these arrays to operate close to or at the single mode limit. Doing so introduces several new challenges that are not experienced in the multi-mode case of far-infrared detectors having similar pixel sizes. First, diffractive effects of the pixels themselves are no longer insignificant and will ultimately contribute to the resolution limit of the optical system in which they reside. We use the method of Withlngton et al. (2003) to model the polarized diffraction in this limit. Second, it is necessary to re-examine the coupling between the radiation and the absorbing element that is thermally connected to the bolometers. The small f-numbers that are often employed to make use of large focal planes makes backshort construction problematic. We introduce a new strategy to increase detector efficiency that uses an antireflective layer on the front side of the detector array. In addition, typical methods for stray light control that rely on multiple reflections in a lossy medium fail due to physical size constraints. For this application, we find that resonant absorbers are a more effective strategy that can be implemented in the space available.

Wollack, Edward J.↗

5,120 Superconducting Bolometers for the PIPER Balloon-Borne CMB Polarization Experiment

We are constructing the Primordial Inflation Polarization Explorer (PIPER) to measure the polarization of the cosmic microwave background (CMB) and search for the imprint of gravity waves produced during an inflationary epoch in the early universe. The signal is faint and lies behind confusing foregrounds, both astrophysical and cosmological, and so many detectors are required to complete the measurement in a limited time. We will use four of our matured 1,280 pixel, high-filling-factor backshort-under-grid bolometer arrays for efficient operation at the PIPER CMB wavelengths. All four arrays observe at a common wavelength set by passband filters in the optical path. PIPER will fly four times to observe at wavelengths of 1500, 1100, 850, and 500 microns in order to separate CMB from foreground emission. The arrays employ leg-isolated superconducting transition edge sensor bolometers operated at 145 mK; tuned resonant backshorts for efficient optical coupling; and a second-generation superconducting quantum interference device multiplexer readout. We describe the design, development, and performance of PIPER bolometer array technology to achieve background-limited sensitivity for a cryogenic balloon-borne telescope.

Benford, Dominic J.↗

5,120 Superconducting Bolometers for the PIPER Balloon-Borne CMB Polarization Experiment

We are constructing the Primordial Inflation Polarization Explorer (PIPER) to measure the polarization o[ the cosmic microwave background (CMB) and search for the imprint of gravity waves produced during an inflationary epoch in the early universe. The signal is faint and lies behind confusing foregrounds, both astrophysical and cosmological, and so many detectors are required to complete the measurement in a limited time. We will use four of our matured 1,280 pixel, high-filling-factor backshort-under-grid bolometer arrays for efficient operation at the PIPER CMB wavelengths. All four arrays observe at a common wavelength set by passband filters in the optical path. PIPER will fly four times to observe at wavelengths of 1500, 1100, 850, and 500 microns in order to separate CMB from foreground emission. The arrays employ leg-isolated superconducting transition edge sensor bolometers operated at 128mK; tuned resonant backshorts for efficient optical coupling; and a second-generation superconducting quantum interference device (SQUID) multiplexer readout. We describe the design, development, and performance of PIPER bo|ometer array technology to achieve background-limited sensitivity for a cryogenic balloon-borne telescope.

Benford, Dominic J.↗

An Ultrasensitive Hot-Electron Bolometer for Low-Background SMM Applications

We are developing a hot-electron superconducting transition-edge sensor (TES) that is capable of counting THz photons and operates at T = 0.3K. The main driver for this work is moderate resolution spectroscopy (R approx. 1000) on the future space telescopes with cryogenically cooled (approx. 4 K) mirrors. The detectors for these telescopes must be background-limited with a noise equivalent power (NEP) approx. 10(exp -19)-10(exp -20) W/Hz(sup 1/2) over the range v = 0.3-10 THz. Above about 1 THz, the background photon arrival rate is expected to be approx. 10-100/s), and photon counting detectors may be preferable to an integrating type. We fabricated superconducting Ti nanosensors with a volume of approx. 3x10(exp -3) cubic microns on planar substrate and have measured the thermal conductance G to the thermal bath. A very low G = 4x10(exp -14) W/K, measured at 0.3 K, is due to the weak electron-phonon coupling in the material and the thermal isolation provided by superconducting Nb contacts. This low G corresponds to NEP(0.3K) = 3x10(exp -19) W/Hz(sup 1/2). This Hot-Electron Direct Detector (HEDD) is expected to have a sufficient energy resolution for detecting individual photons with v > 0.3 THz at 0.3 K. With the sensor time constant of a few microseconds, the dynamic range is approx. 50 dB.

bolometers↗

The IR energy distribution of SS433

The infrared energy distribution of the emission-line object SS 433 in the range 1 to 10 microns is determined. Photometric measurements were made with a 2.2-m telescope using an InSb detector and a 6-arcsec diaphragm for 1.2- to 4.8-micron observations and a gallium-doped germanium bolometer with a 6-arcsec diaphragm for 8- to 13-micron observations. Results indicate the presence of substantial night-to-night flux density and color variations, and a decrease in flux density at wavelengths greater than 5 microns. The energy cut-off is used to estimate a physical size of 1 AU for the emitting region and an electron density of 10 to the 11th/cu cm on the basis of a model of reddened free-free emission from an ionized plasma, with self-absorption of radiation over 5 microns. The greater variability observed at longer wavelengths is also interpreted in terms of this model.

Wynn-Williams, C. G.↗

MgB2-Based Bolometer Array for Far Infra-Red Thermal Imaging and Fourier Transform Spectroscopy Applications

The mid-superconducting critical temperature (T(sub c) approximately 39 K) of the simple binary, intermetallic MgB, [1] makes it a very good candidate for the development of the next generation of electrooptical devices (e.g. [2]). In particular, recent advances in thin film deposition teclmiques to attain higb quality polycrystalline thin film MgB, deposited on SiN-Si substrates, with T(sub c) approximately 38K [3] coupled with the low voltage noise performance of the film [4] makes it higbly desirable for the development of moderately cooled bolometer arrays for integration into future space-bourne far infra-red (FIR) spectrometers and thermal mappers for studying the outer planets, their icy moons and other moons of interest in the 17-250 micrometer spectral wavelength range. Presently, commercially available pyroelectric detectors operating at 300 K have specific detectivity, D(*), around 7 x 10(exp 8) to 2 x 10(exp 9) centimeters square root of Hz/W. However, a MgB2 thin film based bolometer using a low-stress (less than 140 MPa) SiN membrane isolated from the substrate by a small thermal conductive link, operating at 38 K, promises to have two orders of magnitude higher specific detectivity [5][6].

Lakew, B.↗