Search NASA⌕ Search

SEARCH · Search NASA

Results for “bragg diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Correlated Anion Disorder in Heteroanionic Cubic TiOF 2

Resolving anion configurations in heteroanionic materials is crucial for understanding and controlling their properties. For anion-disordered oxyfluorides, conventional Bragg diffraction cannot fully resolve the anionic structure, necessitating alternative structure determination methods. We have investigated the anionic structure of anion-disordered cubic (ReO 3 -type) TiOF 2 using X-ray pair distribution function (PDF), 19 F MAS NMR analysis, density functional theory (DFT), cluster expansion modeling, and genetic-algorithm structure prediction. Our computational data predict short-range anion ordering in TiOF 2 , characterized by predominant cis-[O 2 F 4 ] titanium coordination, resulting in correlated anion disorder at longer ranges. To validate our predictions, we generated partially disordered supercells using genetic-algorithm structure prediction and computed simulated X-ray PDF data and 19 F MAS NMR spectra, which we compared directly to experimental data. To construct our simulated 19 F NMR spectra, we derived new transformation functions for mapping calculated magnetic shieldings to predicted magnetic chemical shifts in titanium (oxy)fluorides, obtained by fitting DFT-calculated magnetic shieldings to previously published experimental chemical shift data for TiF 4 . We find good agreement between our simulated and experimental data, which supports our computationally predicted structural model and demonstrates the effectiveness of complementary experimental and computational techniques in resolving anionic structure in anion-disordered oxyfluorides. From additional DFT calculations, we predict that increasing anion disorder makes lithium intercalation more favorable by, on average, up to 2 eV, highlighting the significant effect of variations in short-range order on the intercalation properties of anion-disordered materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reaching the third dimension

X-ray imaging is extensively used in medical and materials science. Traditionally, the depth dimension is obtained by turning the sample to gain different views. The famous penetrating properties of X-rays mean that projection views of the subject sample can be readily obtained in the linear absorption regime. 180 degrees of projections can then be combined using computed tomography (CT) methods to obtain a full 3D image, a technique extensively used in medical imaging. In the work now presented in Nature Materials, Stephan Hruszkewycz and colleagues have demonstrated genuine 3D imaging by a new method called 3D Bragg projection ptychography1. Our approach combines the 'side view' capability of using Bragg diffraction from a crystalline sample with the coherence capabilities of ptychography. Thus, it results in a 3D image from a 2D raster scan of a coherent beam across a sample that does not have to be rotated.

36 MATERIALS SCIENCE↗

Structural dynamics in proteins induced by and probed with X-ray free-electron laser pulses

X-ray free-electron lasers (XFELs) enable crystallographic structure determination beyond the limitations imposed upon synchrotron measurements by radiation damage. The need for very short XFEL pulses is relieved through gating of Bragg diffraction by loss of crystalline order as damage progresses, but not if ionization events are spatially non-uniform due to underlying elemental distributions, as in biological samples. Indeed, correlated movements of iron and sulfur ions were observed in XFEL-irradiated ferredoxin microcrystals using unusually long pulses of 80 fs. Here, we report a femtosecond time-resolved X-ray pump/X-ray probe experiment on protein nanocrystals. We observe changes in the protein backbone and aromatic residues as well as disulfide bridges. Simulations show that the latter’s correlated structural dynamics are much slower than expected for the predicted high atomic charge states due to significant impact of ion caging and plasma electron screening. This indicates that dense-environment effects can strongly affect local radiation damage-induced structural dynamics.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Femtosecond laser produced periodic plasma in a colloidal crystal probed by XFEL radiation

With the rapid development of short-pulse intense laser sources, studies of matter under extreme irradiation conditions enter further unexplored regimes. In addition, an application of X-ray Free-Electron Lasers (XFELs) delivering intense femtosecond X-ray pulses, allows to investigate sample evolution in IR pump - X-ray probe experiments with an unprecedented time resolution. Here we present a detailed study of the periodic plasma created from the colloidal crystal. Both experimental data and theory modeling show that the periodicity in the sample survives to a large extent the extreme excitation and shock wave propagation inside the colloidal crystal. This feature enables probing the excited crystal, using the powerful Bragg peak analysis, in contrast to the conventional studies of dense plasma created from bulk samples for which probing with Bragg diffraction technique is not possible. X-ray diffraction measurements of excited colloidal crystals may then lead towards a better understanding of matter phase transitions under extreme irradiation conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward fully automated UED operation using two-stage machine learning model

To demonstrate the feasibility of automating UED operation and diagnosing the machine performance in real time, a two-stage machine learning (ML) model based on self-consistent start-to-end simulations has been implemented. This model will not only provide the machine parameters with adequate precision, toward the full automation of the UED instrument, but also make real-time electron beam information available as single-shot nondestructive diagnostics. Furthermore, based on a deep understanding of the root connection between the electron beam properties and the features of Bragg-diffraction patterns, we have applied the hidden symmetry as model constraints, successfully improving the accuracy of energy spread prediction by a factor of five and making the beam divergence prediction two times faster. The capability enabled by the global optimization via ML provides us with better opportunities for discoveries using near-parallel, bright, and ultrafast electron beams for single-shot imaging. It also enables directly visualizing the dynamics of defects and nanostructured materials, which is impossible using present electron-beam technologies.

36 MATERIALS SCIENCE↗

Model-based iterative reconstruction with adaptive regularization for artifact reduction in electron tomography

Obtaining high-quality 3D reconstructions from electron tomography of crystalline particles embedded in lighter support elements is crucial for various material systems such as catalysts for fuel cell applications. However, significant challenges arise due to the limited tilt range, sparse and low signal-to-noise ratio of the measurements. In addition, small metal particles can cause strong streaking and shading artifacts in the 3D reconstructions when using conventional reconstruction algorithms due to the presence of Bragg diffraction and the large scattering cross-section difference between the materials of the particles and the background support regions. These artifacts lead to errors in the downstream characterization affecting extraction of critical features such as the size of the metal particles, their distribution and the volume of the lighter support regions. In this paper, we present a two-stage algorithm based on metal artifact reduction, utilizing model-based iterative reconstruction methods with adaptive adjustment of regularization parameters. Our approach yields high-quality 3D reconstructions compared to traditional algorithms, accurately capturing both the metal particles as well as the background support. We demonstrate the effectiveness of our algorithm through simulated and experimental bright-field electron tomography data, showing significant improvements in reconstruction quality compared to traditional methods.

97 MATHEMATICS AND COMPUTING↗

Structural evolution during solution-based synthesis of Li 7 P 3 S 11 solid electrolyte by synchrotron X-ray total scattering

Solution-based synthesis has emerged as a promising approach for scalable and efficient synthesis of solid electrolytes (SEs). However, the ionic conductivity of solution-synthesized SEs is much lower than that of SEs synthesized by solid state approaches. The structural evolution during the synthesis of SEs is crucial to explaining the decreased ionic conductivities but has not been well understood. Here, in this work, we use synchrotron X-ray total scattering combined with pair distribution function (PDF) analysis to understand the structural evolution during annealing of the solution-processed precursor for the synthesis of Li 7 P 3 S 11 SEs. Combining Bragg diffraction and diffuse scattering, X-ray total scattering enables detection of structural information including phase transition and crystallinity. The results show that the formation of Li 7 P 3 S 11 glass-ceramic starts at 230 °C. Increasing the annealing temperature helps to improve the crystallinity, but the degree of crystallization is still lower than 70.3% even after annealing at 290 °C when thermal decomposition of Li 7 P 3 S 11 to Li 4 P 2 S 6 has occurred. PDF analysis also revealed the existence of acetonitrile used in the solution-based synthesis in the SEs after annealing at high temperatures. The results rationalize the synthesis–property relationship, explain why annealing at 290 °C provides the highest ionic conductivity at the studied temperatures due to an optimal balance for achieving a high crystallinity while suppressing severe decomposition of Li 7 P 3 S 11 , and provide novel insights to develop approaches for synthesizing superior Li 7 P 3 S 11 SEs on a large scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-enzymatic glucose detection using magnetic nanoemulsions

We probe the optical properties and intermolecular interactions in magnetically responsive nanoemulsions in the presence of glucose. The equilibrium interdroplet distance between the emulsion droplets in an one-dimensional array increases by several nanometers in the presence of glucose because of intermolecular hydrogen bonding with sodium dodecyl sulphate molecules at the oil-water interface that gives rise to stretched lamellae-like structure. The observed large red shift in the diffracted Bragg peak (∼50–100 nm) and the linear response in the glucose concentration range of 0.25–25 mM offer a simple, fast, and cost effective non-enzymatic approach for glucose detection.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Crystal Backlighter Imager: A spherically bent crystal imager for radiography on the National Ignition Facility

The Crystal Backlighter Imager (CBI) is a quasi-monochromatic, near-normal incidence, spherically bent crystal imager developed for the National Ignition Facility (NIF), which will allow inertial confinement fusion capsule implosions to be radiographed close to stagnation. This is not possible using the standard pinhole-based area-backlighter configuration, as the self-emission from the capsule hotspot overwhelms the backlighter signal in the final stages of the implosion. The CBI mitigates the broadband self-emission from the capsule hot spot by using the extremely narrow bandwidth inherent to near-normal-incidence Bragg diffraction. Implementing a backlighter system based on near-normal reflection in the NIF chamber presents unique challenges, requiring the CBI to adopt novel engineering and operational strategies. The CBI currently operates with an 11.6 keV backlighter, making it the highest energy radiography diagnostic based on spherically bent crystals to date. For a given velocity, Doppler shift is proportional to the emitted photon energy. At 11.6 keV, the ablation velocity of the backlighter plasma results in a Doppler shift that is significant compared to the bandwidth of the instrument and the width of the atomic line, requiring that the shift be measured to high accuracy and the optics aligned accordingly to compensate. Experiments will be presented that used the CBI itself to measure the backlighter Doppler shift to an accuracy of better than 1 eV. These experiments also measured the spatial resolution of CBI radiographs at 7.0 μm, close to theoretical predictions. Results will be presented from an experiment in which the CBI radiographed a capsule implosion driven by a 1 MJ NIF laser pulse, demonstrating a significant (>100) improvement in the backlighter to self-emission ratio compared to the pinhole-based area-backlighter configuration.

47 OTHER INSTRUMENTATION↗

Variable Bragg x-ray beam splitters

Beam splitters are utilized in a variety of advanced x-ray instruments and are essential for extending quantum optics techniques to x rays. A new fabrication method has produced thinned Bragg diffracting silicon devices with variable reflectivity and transmission coefficients and negligible absorption losses. Diffraction measurements confirm that silicon continues to exhibit perfect crystal diffraction even for thicknesses below two microns. Devices are machined from standard wafers, with the thinned regions contained within the robust frame of an unperturbed crystal for ease of handling.

Powers, L. T. (ORCID:000900047481248X)↗

First use of an InSb crystal for x-ray imaging spectroscopy of highly ionized tungsten in the Wendelstein 7-X stellarator

Advances in time and space resolved measurements of highly charged states of tungsten (W) through x-ray imaging spectroscopy have enabled investigation of impurity transport in the Wendelstein 7-X (W7-X) stellarator. The high-resolution x-ray imaging spectrometer (HR-XIS) system on W7-X utilizes the Bragg diffraction properties of a set of multiple crystals to measure a range of impurity emission lines within sections of the 1–7 Å wavelength range, including transitions of W. A new indium–antimonide crystal has been installed on the HR-XIS system to allow viewing of the 5.5–6.2 Å region focusing on emissions of W. Consequently, many bright W emission lines from W 40+ to W 47+ were observed in this wavelength range, both in plasmas with injected W and in those with only intrinsic W impurity sources, showing the high sensitivity of the diagnostic. Three W 46+ emissions correspond in wavelength and intensity with calculated photon emissivity coefficients and can be exploited for W transport and concentration applications in plasmas with T e ≳ 2.1 keV. Here, an estimate of the core W density behavior in two separate turbulence-reduced ‘high-performance’ (HP) discharges on W7-X is done using the 5.6893 Å W 46+ line. The n W behavior in HP scenarios can be explained by previous experimental results and neoclassical predictions.

XICS↗

Precision determination of absolute neutron flux

A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using an alpha–gamma counter. The method involves only the counting of measured rates and is independent of neutron cross sections, decay chain branching ratios, and neutron beam energy. For the measurement, a target of 10 B-enriched boron carbide totally absorbed the neutrons in a monochromatic beam, and the rate of absorbed neutrons was determined by counting 478 keV gamma rays from neutron capture on 10 B with calibrated high-purity germanium detectors. A second measurement based on Bragg diffraction from a perfect silicon crystal was performed to determine the mean de Broglie wavelength of the beam to a precision of 0.024%. With these measurements, the detection efficiency of a neutron monitor based on neutron absorption on 6 Li was determined to an overall uncertainty of 0.058%. We discuss the principle of the alpha–gamma method and present details of how the measurement was performed including the systematic effects. We further describe how this method may be used for applications in neutron dosimetry and metrology, fundamental neutron physics, and neutron cross section measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electric field dependent local structure of ( K x N a 1 - x ) 0.5 B i 0.5 Ti O 3

The in situ x-ray pair-distribution function (PDF) characterization technique has been used to study the behavior of (K x Na 1–x ) 0.5 Bi 0.5 TiO 3 , as a function of electric field. As opposed to conventional x-ray Bragg diffraction techniques, PDF is sensitive to local atomic displacements, detecting local structural changes at the angstrom to nanometer scale. Several field-dependent ordering mechanisms can be observed in x = 0.15, 0.18 and at the morphotropic phase boundary composition x = 0.20. X-ray total scattering shows suppression of diffuse scattering with increasing electric-field amplitude, indicative of an increase in structural ordering. Analysis of PDF peaks in the 3–4-Å range shows ordering of Bi-Ti distances parallel to the applied electric field, illustrated by peak amplitude redistribution parallel and perpendicular to the electric-field vector. A transition from < 110 > to < 112 >-type off-center displacements of Bi relative to the neighboring Ti atoms is observable with increasing x. Analysis of PDF peak shift with electric field shows the effects of Bi-Ti redistribution and onset of piezoelectric lattice strain. Furthermore, the combination of these field-induced ordering mechanisms is consistent with local redistribution of Bi-Ti distances associated with domain reorientation and an overall increase in order of atomic displacements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Achieving a near-ideal silicon crystal neutron interferometer using submicrometer fabrication techniques

Perfect-crystal neutron interferometry, which is analogous to Mach-Zehnder interferometry, uses Bragg diffraction to form interfering neutron paths. The measured phase shifts can be used to probe many types of interactions whether it be nuclear, electromagnetic, gravitational, or topological in nature. For a perfect-crystal interferometer to preserve coherence, the crystal must possess a high degree of dimensional tolerance as well as being relatively defect-free with minimal internal stresses. In the past, perfect-crystal neutron interferometers have been produced by a two-step process. First, a resin diamond wheel would be used to remove excess material and shape the interferometer. Afterword, the crystal would be etched to remove surface defects and elevate strains. This process has had limitations in terms of repeatability and in maximizing the final contrast, or fringe visibility, of the interferometer. We have tested various fabrication and post-fabrication techniques on a single perfect-crystal neutron interferometer and measured the interferometer's performance at each step. Here we report a robust, nonetching fabrication process with high final contrast. For the interferometer used in this work, we achieved contrasts of greater than 90% several times and ultimately finished with an interferometer that has 92% contrast and a uniform phase distribution. Published by the American Physical Society 2024

Huber, M. G. (ORCID:0000000237958445)↗

Autoindexing with outlier rejection and identification of superimposed lattices

Constructing a model lattice to fit the observed Bragg diffraction pattern is straightforward for perfect samples, but indexing can be challenging when artifacts are present, such as poorly shaped spots, split crystals giving multiple closely aligned lattices and outright superposition of patterns from aggregated microcrystals. To optimize the lattice model against marginal data, refinement can be performed using a subset of the observations from which the poorly fitting spots have been discarded. Outliers are identified by assuming a Gaussian error distribution for the best-fitting spots and points diverging from this distribution are culled. The set of remaining observations produces a superior lattice model, while the rejected observations can be used to identify a second crystal lattice, if one is present. The prevalence of outliers provides a potentially useful measure of sample quality. The described procedures are implemented for macromolecular crystallography within the autoindexing program labelit.index (http://cci.lbl.gov/labelit).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Epitaxial intergrowths and local oxide relaxations in natural bixbyite Fe 2– x Mn x O 3

The scattering pattern of a crystal obeys the symmetry of the crystal structure through the corresponding Laue group. This is usually also true for the diffuse scattering, containing information about disorder, but here a case is reported where the diffuse scattering is of lower symmetry than the parent crystal structure. The mineral bixbyite has been studied by X-ray and neutron scattering techniques since 1928 with some of the most recent studies characterizing the low-temperature transition to a magnetically disordered spin-glass state. However, bixbyite also exhibits structural disorder, and here single-crystal X-ray and neutron scattering is used to characterize the different modes of disorder present. One-dimensional rods of diffuse scattering are observed in the cubic mineral bixbyite, which break the expected symmetry of the scattering pattern. It is shown that this scattering arises from epitaxial intergrowths of the related mineral, braunite. The presence of this disorder mode is found to be directly observable as well-defined residuals in the average structure refined against the Bragg diffraction. An additional three-dimensional diffuse scattering component is observed in neutron scattering data, which is shown to originate from the substitutional disorder on the Fe/Mn sites. This occupational disorder gives rise to local relaxations of the oxide sublattice, and the pattern of oxide displacements can be rationalized based on crystal-field theory. The combined use of neutron and X-ray single-crystal scattering techniques highlights their great complementarity. In particular, the large sample requirements for neutron scattering experiments prove to be an obstacle in solving the intergrowth disorder due to several growth orientations, whereas for X-ray scattering the one-dimensional nature of the intergrowth disorder renders solving this a more tractable task. On the other hand, the oxide relaxations cannot be resolved using X-rays due to the low Mn/Fe contrast. By combining the two approaches both types of disorder have been characterized.

36 MATERIALS SCIENCE↗

Observation of bound states in the continuum embedded in symmetry bandgaps

In the past decade, symmetry-protected bound states in the continuum (BICs) have proven to be an important design principle for creating and enhancing devices reliant upon states with high-quality (Q) factors, such as sensors, lasers, and those for harmonic generation. However, as we show, current implementations of symmetry-protected BICs in photonic crystal slabs can only be found at the center of the Brillouin zone and below the Bragg diffraction limit, which fundamentally restricts their use to single-frequency applications. By microprinting a three-dimensional (3D) photonic crystal structure using two-photon polymerization, we demonstrate that this limitation can be overcome by altering the radiative environment surrounding the slab to be a 3D photonic crystal. This allows for the protection of a line of BICs by embedding it in a symmetry bandgap of the crystal. This concept substantially expands the design freedom available for developing next-generation devices with high-Q states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

pyCroscopy

Suite of Python Libraries that implement structure data format processing, multivariate analysis, and interactive visualization of microscopy data and other spectral imaging modalities, including scanning probe microscopy, electron microscopy, Bragg diffraction microscopy, and chemical imaging.

Jesse, Stephen↗