Search NASA⌕ Search

SEARCH · Search NASA

Results for “building management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Community-scale interaction of energy efficiency and demand flexibility in residential buildings

Demand-side management (DSM) strategies, including energy efficiency (EE) and demand flexibility (DF), contribute to cost-effective operation of the electricity grid. From a system-level perspective, such programs reduce costs, enhance reliability, and reduce network issues. Similarly, DSM programs help participating customers reduce utility bills while maintaining occupant comfort. Understanding the relationship between EE and DF is key to realizing the full potential of DSM programs. In this study, we modeled an all-electric residential community based on a 498-home community that is planned for construction in Fort Collins, Colorado in the United States. We used this community model to study the relationship between different EE measures, including building envelope upgrades and smart appliances, and DF enabled by a home energy management system (HEMS) responding to a time-varying tariff. Various EE levels in the homes – code-minimum, zero energy ready, and even higher levels of envelope efficiency – were simulated. DF is enabled by the HEMS, which coordinates behind-the-meter resources, including flexible building loads, PV, and home battery systems, to minimize utility bills while maintaining occupant comfort. When comparing to the code-minimum homes, EE upgrades alone reduce HVAC energy use during peak hours by up to 50% and the HVAC utility bill by up to $312/year. With the addition of HEMS, the average daily peak demand can be reduced by up to 0.58 MW or 1.2 kW/home in the higher envelope efficiency homes. The combination of EE upgrades, HEMS, and home battery systems is expected to save homeowners up to $590/year while increasing community load flexibility. However, HEMS and home battery systems are less effective in increasing the DF in the more efficient homes due to the lower load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A critical review of cyber-physical security for building automation systems

Modern Building Automation Systems (BASs), as the brain that enable the smartness of a smart building, often require increased connectivity both among system components as well as with outside entities, such as the cloud, to enable low-cost remote management, optimized automation via outsourced cloud analytics, and increased building-grid integrations. As smart buildings move towards open communication technologies, providing access to BASs through the building's intranet, or even remotely through the Internet, has become a common practice. However, increased connectivity and accessibility come with increased cyber security threats. BASs were historically developed as closed environments with limited cyber-security considerations. As a result, BASs in many buildings are vulnerable to cyber-attacks that may cause adverse consequences, such as occupant discomfort, excessive energy usage, and unexpected equipment downtime. Therefore, there is a strong need to advance the state-of-the-art in cyber-physical security for BASs and provide practical solutions for attack mitigation in buildings. However, an inclusive and systematic review of BAS vulnerabilities, potential cyber-attacks with impact assessment, detection & defense approaches, and cyber resilient control strategies is currently lacking in the literature. This review paper fills the gap by providing a comprehensive up-to-date review of cyber-physical security for BASs at three levels in commercial buildings: management level, automation level, and field level. The general BASs vulnerabilities and protocol-specific vulnerabilities for the four dominant BAS protocols (i.e., BACnet, KNX, LonWorks, and Modbus) are reviewed, followed by a discussion on four attack targets and seven potential attack scenarios. Furthermore, the impact of cyber-attacks on BASs is summarized as signal corruption, signal delaying, and signal blocking. The typical cyber-attack detection and defense approaches are identified at the three levels. Cyber resilient control strategies for BASs under attack are categorized into passive and active resilient control schemes. Open challenges and future opportunities are finally discussed.

97 MATHEMATICS AND COMPUTING↗

Life cycle Management of 324 Project High-Activity, Mixed/Low-Level Radioactive Waste - 20506

U.S. DOE contractor CH2M Hill Plateau Remediation Company (CHPRC) manages the 324 Building and is preparing to remotely excavate and disposition the radioactive soil beneath the building to allow further deactivation of the building. The 324 Building is a non-reactor Category 2 Nuclear Facility located in the 300 Area of the Hanford Site. Records indicate that in October 1986, approximately 516 liters of a concentrated liquid waste stream containing cesium-137 ({sup 137}Cs) and strontium-90 ({sup 90}Sr) spilled onto the floor of a hot cell, B-Cell, in the 324 Building. The spill contained an estimated 1.3 million curies (Ci) of radioactivity. A breach in the sump of B-Cell was discovered in November 2009 during characterization of the soil under the building. Exposure rates in excess of 10,000 R/hr were detected through a system of access pipes installed under the hot cell, and an estimated 1.557 E+05 Ci of {sup 137}Cs and 6.842 E+04 Ci of {sup 90}Sr are in the soil beneath B-Cell. The magnitude of the soil contamination below B-Cell represents one of the most challenging remediation activities in the DOE complex. The objective of CHPRC's 324 Project is to remotely excavate and disposition the highly contaminated soil under the hot cell so building deactivation and stabilization activities can resume. Depending on the volume and radioactivity of contaminated soil under B-Cell, the material will be dispositioned either at the Hanford Site's Environmental Restoration Disposal Facility (ERDF) or in grout monoliths that will be created in the hot cells (A, C and D) next to B-Cell during future building demolition activities. The current project scope includes installing structural supports under the walls of B-Cell and using remotely operated equipment to remove debris from the hot cell, remove debris mixed with grout on the floor, saw through and remove the cell floor and liner, and excavate contaminated soil under B-Cell to a depth of up to 3.66 meters (12 feet). Addition or removal of debris in A-Cell may be required to support B-Cell cleanout and excavation activities. The base approach is to disposition debris and soil bins in the Radiochemical Engineering Cell (REC) monoliths, and subsequently disposition the monoliths during building demolition. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Key Grid-Interactive Efficient Building Technologies for Federal and Commercial Facilities

This report serves as a resource for building owners and managers interested in deploying GEB technologies in federal and commercial facilities. This document also provides an overview of smart buildings and the prioritization and categorization of GEB technologies that have a high potential to provide grid services.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency and Indoor Environmental Quality Assessment Guide

This report provides thorough guidance when preparing for an energy and indoor environmental quality (IEQ) assessment. It includes step-by-step instructions, detailed insights, and practical examples for the various phases of an energy and IEQ assessment. IEQ encompasses indoor building conditions—such as air quality, thermal comfort, acoustics, and lighting— and is a growing field of interest among a diverse range of stakeholders (e.g., building owners and managers) due to the effects it has on occupant health and productivity. IEQ improvement strategies often provide overlapping opportunities for increasing building energy efficiency, creating a win-win situation for building operations.

Esaki-Kua, Lauren↗

Online transfer learning strategy for enhancing the scalability and deployment of deep reinforcement learning control in smart buildings

In recent years, advanced control strategies based on Deep Reinforcement Learning (DRL) proved to be effective in optimizing the management of integrated energy systems in buildings, reducing energy costs and improving indoor comfort conditions when compared to traditional reactive controllers. However, the scalability and implementation of DRL controllers are still limited since they require a considerable amount of time before converging to a near-optimal solution. This issue is currently addressed in literature through the offline pre-training of the DRL agent. However this solution results in two main critical issues: (1) the need to develop a building surrogate model to perform the training task, and (2) the need to perform a fine-tuning process over several training episodes to obtain a near-optimal control policy. In this context, this paper introduces an Online Transfer Learning (OTL) strategy that exploits two knowledge-sharing techniques, weight-initialization and imitation learning, to transfer a DRL control policy from a source office building to various target buildings in a simulation environment coupling EnergyPlus and Python. A DRL controller based on discrete Soft Actor–Critic (SAC) is trained on the source building to manage the operation of a cooling system consisting of a chiller and a thermal storage. Several target buildings are defined to benchmark the performance of the OTL strategy with that of a Rule-Based Controller (RBC) and two DRL-based control strategies, deployed in offline and online fashion. The strategy adopted for OTL emulates the real world implementation with a simulation process by implementing the transferred DRL agent for a single episode in the target buildings. Target buildings have the same geometrical features and are served by the same energy system as the source building, but differ in terms of weather conditions, electricity price schedules, occupancy patterns, and building envelope efficiency levels. The results show that the OTL strategy can reduce the cumulated sum of temperature violations on average by 50% and 80% respectively when compared to RBC and online DRL while enhancing the energy system operation with electricity cost savings ranging between 20% and 40%. Furthermore, the OTL agent performs slightly worse than the offline DRL controller but it does not require any modeling effort and can be implemented directly on target buildings emulating a real-world implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ten questions concerning Large Language Models (LLMs) for building applications

Large Language Models (LLMs) are emerging as powerful AI tools capable of transforming how building information is collected, processed, analyzed, and applied across diverse research areas. Their capabilities can help building operators, facility managers and other stakeholders such as designers, architects and engineers by providing actionable insights for decision-making across planning, construction, operations, and maintenance of buildings and facilities. This paper explores ten key questions concerning the role of LLMs in shaping sustainable, intelligent, and human-centric buildings. From fundamental definitions to advanced applications, we examine how LLMs facilitate decision-making across the life cycle of buildings and energy systems. LLMs can enhance life cycle assessments (LCA), building energy simulations, and real-time data integration, empowering more efficient and adaptive human-AI environments. They can also contribute to streamlining regulatory compliance, improving post-occupancy evaluations, and fostering more inclusive and participatory design processes. Additionally, this paper addresses the ethical challenges posed by LLMs, such as bias, data privacy, and environmental impacts, and explores their potentials in advancing intelligent digital twins (DT) for ongoing building operations and maintenance. Built upon our applied research using LLMs and the review of tools, datasets, and research gaps, we provide a forward-looking perspective on how LLMs can drive innovation, collaboration, and productivity in the built environment while supporting ethical and effective implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Management Information System Powers NREL's Intelligent Campus

NREL's Intelligent Campus program leverages its own laboratory buildings as research instruments to study renewable energy, energy efficiency, and energy storage, integration, and analysis with real, quantitative measurements. At the heart of NREL's Intelligent Campus program is its Energy Management Information System (EMIS), a family of tools and services used to manage building and campus energy use. NREL's EMIS includes capabilities, such as benchmarking and monthly utility tracking, interval meter analytics, equipment fault detection and diagnostics, condition-based monitoring, and supervisory control, enabling unprecedented energy management capabilities. The system serves as a demonstration project for other federal facilities interested in learning about its design, features, and benefits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy Management Information System Powers NREL's Intelligent Campus

NREL's Intelligent Campus program leverages its own laboratory buildings as research instruments to study renewable energy, energy efficiency, and energy storage, integration, and analysis with real, quantitative measurements. At the heart of NREL's Intelligent Campus program is its Energy Management Information System (EMIS), a family of tools and services used to manage building and campus energy use. NREL's EMIS includes capabilities, such as benchmarking and monthly utility tracking, interval meter analytics, equipment fault detection and diagnostics, condition-based monitoring, and supervisory control, enabling unprecedented energy management capabilities. The system serves as a demonstration project for other federal facilities interested in learning about its design, features, and benefits.

EMIS↗

Very High Efficiency Dedicated Outdoor Air System Field Site Re-Evaluation

The study reported here evaluated the long-term performance of Very High Efficiency (VHE) Dedicated Outside Air Systems (DOASs) installed at eight sites that participated in field evaluation studies performed by the Northwest Energy Efficiency Alliance (NEEA) and Institute for Market Transformation (IMT) from 2015 through 2020. The study compared the energy performance of the systems in 2021-2022 to the findings of the original evaluation. It also evaluated the indoor environmental quality (IEQ) as perceived by occupants and building operator feedback before and after the system conversion. The findings of the study are important for building owners and managers who are considering adopting VHE DOASs. The study found that the systems: (1) consistently saved energy over the long term, (2) improved occupant comfort, and (3) received positive feedback from building operators. All of the sites had similar or improved energy savings over the pre-conversion system compared to the original evaluation savings, and only one site had a small reduction in energy savings. The sites averaged 48 percent whole site energy savings compared to the pre-conversion system. The continued energy performance of these sites provides strong evidence that the energy savings achieved by VHE DOAS retrofits will be sustained long term. The study also investigated the changes in occupant comfort resulting from the VHE DOAS retrofit. Responses to a survey sent to the sites’ occupants revealed that the conversion resulted in a better indoor environment for the occupants. Most respondents reported that their satisfaction increased, and dissatisfaction decreased post-conversion. Overall occupants were 43 percent more satisfied and 30 percent less dissatisfied post-conversion compared to pre-conversion. The study's findings suggest that a VHE DOAS can be a solution to improve the energy efficiency, reduce energy costs, and increase occupant comfort in buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-efficient building technologies

Buildings consume one-third of the total final energy produced on the globe and are responsible for almost 40 percent of total carbon dioxide generation annually. The latest carbon dioxide burden of buildings approached 10 Gigatons in the year 2019. Energy-efficient building technologies are necessary to address the climate change induced by greenhouse gases and fulfill the growth in demand and continuously depleting energy reserves. To meet the net-zero carbon footprint goals, sustainable, renewable energy resources, efficient building technologies, and demand management strategies are needed. Achieving zero emissions will require buildings to be equipped with energy-efficient technologies while completely avoiding on-site fossil fuel consumption and being only powered by renewable energy. In this context, this chapter provides an overview of various building technologies, including envelopes, materials, equipment, appliances, and integration concepts, which will play a significant role in lowering the overall energy consumption in both existing building stock and new buildings. Specifically, the following areas are discussed in detail: emerging building envelope designs, thermal comfort and refrigeration equipment, bridging technologies for improved energy efficiency in the ongoing energy transition, hybrid renewable (photovoltaic) configurations, energy storage technologies, miscellaneous appliances, refrigerants, and renewable fuels. The influence of key design and operating characteristics on annual carbon footprint is presented.

Cheekatamarla, Praveen↗

kessel

Kessel is a tool to create and drive continuous integration (CI) and developer workflows through a unified interface across multiple code projects and environments. It serves as a driver and integration layer for build systems and package managers, providing a flexible library of reusable components to build and execute complex workflows consistently.

Berger, Richard [@lanl]↗

Provider and User Perspectives on Automated Fault Detection and Diagnostic Products for Packaged Rooftop Units

The goal of this project was to understand, based on the primary reporting of AFDD providers and building owners, 1) the features currently available for RTU AFDD in the market today, 2) how RTU AFDD is used by building owners and managers, 3) how well RTU AFDD meets their needs, and 4) what barriers stand in the way of its broad industry adoption. To achieve this goal, 13 AFDD providers were asked about their products and seven building owners were questioned about their practical experience related to the automated detection, diagnosis, and communication of RTU faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decarbonization Considerations: Grid-Interactive Efficient Buildings [Slides]

The Federal Energy Management Program (FEMP) is helping federal agencies understand how to meet decarbonization goals with grid interactive efficient buildings (GEB). This training will provide attendees with an introduction to GEB, how to work with utilities, and opportunities for federal sites.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY25 MOOSE Usability Improvements: 3D Meshing Capabilities, Initiation of Geometry Support for Monte Carlo Tools, and Enhancement of MOOSE/Workbench User Input Interactions

Usability improvements have been made to MOOSE and Workbench in FY25 to enhance usability and user workflows. Assorted enhancement have been made to MOOSE’s intrinsic meshing capabilities in order to enable more flexible and complex meshing of nuclear reactor systems, in particular for 3D applications. Mesh generators have been added to perform operations such as batch mesh generation, surface mesh generation, and creation of 3D transition layers. These mesh generation capabilities make it much easier to generate high quality non-extruded 3D meshes. Additionally, work to integrate Monte Carlo reactor physics simulations into MOOSE-based multi-physics workflows has reached another milestone with the implementation of the Constructive Solid Geometry (CSG) base framework. This framework lays the foundation for mesh generators to offer the user a generic CSG output option (as opposed to a finite element mesh). To support users, workshop on the MOOSE Reactor Module was delivered which featured hands-on examples using the NEAMS Workbench on INL’s High Performance Computing system. Recent updates to the NEAMS Workbench, WASP, and the MOOSE language server have introduced several improvements aimed at making MOOSE-based simulation setup and input management faster, more accurate, and easier to use. Key capabilities that have been added include multi-tab-stop autocompletion, visual input diagnostics, developer-directed data visualizations, upgraded ParaView integration, and Workspace-level file tracking. Together, these changes make it easier for users to build, validate, and manage complex MOOSE-based simulation models — especially those involving reusable components, included files, and datasets. The improvements are designed to save time, reduce input errors, and help users get to a successful simulation run faster, with more confidence in the results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Facility Cybersecurity Framework Best Practices

Federal facilities are increasingly adopting automation and connecting to the Internet creating an energy-internet-of-things environment that converges operational technology (OT) and information technology (IT). Today's buildings increasingly weave together networked sensors and cyber and physical systems that enable data to be collected, aggregated, exchanged, stored and monetized in new ways. Building technological advances have created new energy technology, services, markets and value creation opportunities (e.g. transactive energy, two-way grid communications, machine learning, and increased use of renewable and distributed energy resources). But as larger data sets are being exchanged at faster speeds between an increasing number of OT systems, it becomes more difficult to protect the security of the data lifecycle and the physical equipment it interacts with. These challenges are especially difficult to overcome because the economic and environmental gain (interoperability, big data, social networks and ubiquitous information sharing) are driving these prominent trends in the digital age. Often cybersecurity is an afterthought. The U.S. Department of Energy’s (DOE) Federal Energy Management Program (FEMP) funded the Pacific Northwest National Laboratory (PNNL) to develop various cybersecurity tools, trainings, and reports to aid federal facility managers – and other building owners and operators – in better applying frameworks and lessons learned from the National Institute of Standards and Technology (NIST) Cybersecurity Framework (CSF), risk management framework (RMF), DOE’s cybersecurity capability maturity model (C2M2), and a wide variety of industry best practices and guidance documents (i.e., NIST 800 series, Department of Defense United Facilities Criteria). This set of tools, collectively known as the FEMP Facility-Related Control System Cyber Toolkit (FRCS Cyber Toolkit)2, is focused on cybersecurity concerns from facility-related control systems and other operational technology (OT), such as industrial control systems (ICS). The FRCS Cyber Toolkit can be applied across six of the sixteen critical infrastructure sectors designated by the Department of Homeland Security, including government facilities, healthcare and public health, commercial facilities (e.g., public assembly, offices, lodging), financial services (e.g., banking and insurance), emergency services (e.g., fire and police stations), and information technology. With increasingly converged IT and OT systems, it is crucial to address OT cybersecurity considerations and assess how the seam of these two systems could impact the overall cybersecurity posture of a facility. The objective of this report is to provide an overview of the best possible method to use FRCS Cyber Toolkit (section 2.0) and distilled cybersecurity best practices for the federal facilities to address growing non-linear cyber threats (section 3.0). Recommendations in this document are aggregated from several NIST and other documents (see Appendix A for additional details).

97 MATHEMATICS AND COMPUTING↗

Maximum-impact Adversary Design for Network-based Control System: A Case Study on Grid-interactive Efficient Buildings

The Internet of Things (IoT) technology has dramatically improved the efficiency of today's building operation and management. By connecting controllable devices into a communication network, control signals can be easily passed to the devices, and operating status can be acquired from measurable ends with minimal effort. However, this all-connected configuration could also expose the network-based control system (NBCS) to malicious actions, such as cyberattacks. One of the common NBCSs is the building automation system. With the promotion of grid-interactive efficient buildings (GEBs), there has been increasing attention on securing the buildings from the network perspective. This research proposes a maximum-impact adversary design framework so that the adversary can provide the most adversarial impact on the controlled system while remaining stealthy. The proposed framework is numerically demonstrated on a network-based building energy and control system. The building energy system is built in a Modelica-based simulation environment and controlled by the state-of-the-art ASHRAE Guideline 36 control sequences. The control commands at the supervisory level, generated from the Guideline 36 controller, are assumed to be sent to local devices through communication networks using the BACnet protocol. Simulation results show that the proposed maximum-impact adversary on such a system can stealthily affect the building system's performance to its maximum extent. It is anticipated that results can be used by researchers and practitioners in the building automation industry to design efficient and robust cyber-attack detection algorithms, especially for stealthy attacks.

Chu, Mengyuan↗