Search NASA⌕ Search

SEARCH · Search NASA

Results for “capillary”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Capillary Pump Loop (CPL) heat pipe development status report

The capillary pump loop (CPL) was re-introduced as a potential candidate for the management of large heat loads. It is currently being evaluated for application in the thermal management of large space structures. Test efforts were conducted to establish the feasibility of the CPL heat pipe design.

Source record↗

Generation of capillary instabilities by external disturbances in a liquid jet

The receptivity problem in a circular liquid jet is considered. A time harmonic axial pressure gradient is imposed on the steady, parallel flow of a jet of liquid emerging from a circular duct. Using a technique developed in plasma physics a casual solution to the forced problem is obtained over certain ranges of Weber number for a number of mean velocity profiles. This solution contains a term which grows exponentially in the downstream direction and can be identified with a capillary instability wave. Hence, it is found that the externally imposed disturbances can indeed trigger instability waves in a liquid jet. The amplitude of the instability wave generated relative to the amplitude of the forcing is computed numerically for a number of cases.

Leib, S. J.↗

Thermal-capillary model for Czochralski growth of semiconductor materials

The success of efficiently calculating the temperature field, crystal radius, melt mensicus, and melt/solid interface in the Czochralski crystal growth system by full finite-element solution of the government thermal-capillary model is demonstrated. The model predicts realistic response to changes in pull rate, melt volume, and the thermal field. The experimentally observed phenomena of interface flipping, bumping, and the difficulty maintaining steady-state growth as the melt depth decreases are explained by model results. These calculations will form the basis for the first quantitative picture of Cz crystal growth. The accurate depiction of the melt meniscus is important in calculating the crystal radius and solidification interface. The sensitivity of the results to the equilibrium growth angle place doubt on less sophisticated attempts to model the process without inclusion of the meniscus. Quantitative comparison with experiments should be possible once more representation of the radiation and view factors in the thermal system and the crucible are included. Extensions of the model in these directions are underway.

Derby, J. J.↗

Functional and performance tests of two capillary pumped loop engineering models

This paper presents the results of the functional and performance tests for two capillary pumped loop (CPL) engineering models. Both CPL systems are aluminum/ammonia transport systems which contain eight parallel evaporators and six parallel condensers in a single loop. Tests conducted include the transport limit, heat load shearing between evaporators, liquid inventory/temperature control by the reservoir, pressure priming under heat load, diode function of condensers, and isolation of a single deprimed evaporator. Consistent performance results were obtained for both systems. Transport capabilities of up to 70 kw-m with individual evaporators managing up to 1.7 kw, with a corresponding input heat flux of 15w/sq cm, were demonstrated. These tests demonstrated the ability of a CPL system to operate over a wide range of conditions and thus established the viability of these systems for high power thermal management of large spacecraft, such as the NASA Space Station.

Ku, J.↗

Capillary pumped loop GAS and Hitchhiker flight experiments

Flight experiments of a capillary pumped loop (CPL) aboard the Space Shuttle on both the Get Away Special (GAS) and Hitchhiker-G (H/H-G) carriers are described. These tests have shown that a two-phase heat transfer loop utilizing a wicking material as the system pumping mechanism can operate successfully in a zero-g environment. The CPL operating modes demonstrated were start-up, heat load sharing/natural priming, liquid inventory and temperature control via the reservoir, dryout recovery, and isolation of a single pump deprime. Also investigated were high and low power limits, and inlet subcooling requirements. In these CPL flight experiments, successful system operation was demonstrated at input power levels up to 560 watts and inlet subcooling below 2 C.

Ku, J.↗

Thermal-capillary analysis of Czochralski and liquid encapsulated Czochralski crystal growth

Results are presented from finite element analysis of the Czochralski (CZ) and Liquid Encapsulated Czochralski (LEC) crystal growth processes based on a thermal-capillary model which governs the heat transfer in the system simultaneously with setting the shapes of the melt/solid interface, the melt and encapsulant menisci, and the radius of a steadily growing crystal. Calculations are performed for the small-scale growth of silicon (CZ) and gallium arsenide (LEC). The effects of melt volume and crucible position relative to the heater on the radius of the crystal and the shape of the melt/solid interface are predicted for the CZ system, and the importance of including an accurate representation of the melt meniscus for modeling the process is demonstrated. The additional effect of an encapsulant layer on heat transfer is treated for the LEC method for the cases of totally transparent and opaque encapsulant. The responses of these LEC prototype systems are examined for changes in pull rate and encapsulant volume.

Derby, J. J.↗

Thermal-capillary analysis of Czochralski and liquid encapsulated Czochralski crystal growth. II - Processing strategies

The pseudosteady-state heat transfer model developed in a previous paper is augmented with constraints for constant crystal radius and melt/solid interface deflection. Combinations of growth rate, and crucible and bottom-heater temperatures are tested as processing parameters for satisfying the constrained thermal-capillary problem over a range of melt volumes corresponding to the sequence occuring during the batchwise Czochralski growth of a small-diameter silicon crystal. The applicability of each processing strategy is judged by the range of existence of the solution, in terms of melt volume and the values of the axial and radial temperature gradients in the crystal.

Derby, J. J.↗

Thermal-capillary analysis of small-scale floating zones Steady-state calculations

Galerkin finite element analysis of a thermal-capillary model of the floating zone crystal growth process is used to predict the dependence of molten zone shape on operating conditions for the growth of small silicon boules. The model accounts for conduction-dominated heat transport in the melt, feed rod and growing crystal and for radiation between these phases, the ambient and a heater. Surface tension acting on the shape of the melt/gas meniscus counteracts gravity to set the shape of the molten zone. The maximum diameter of the growing crystal is set by the dewetting of the melt from the feed rod when the crystal radius is large. Calculations with small Bond number show the increased zone lengths possible for growth in a microgravity environment. The sensitivity of the method to the shape and intensity of the applied heating distribution is demonstrated. The calculations are compared with experimental observations.

Duranceau, J. L.↗

Investigation of thermal-fluid mechanical characteristics of the capillary pump and the pumped two-phase loop

This first semi-annual report summarized progress made on NASA Goddard Space Flight Center (GSFC) Grant NAG 5-834 during the period September 1, 1986 to February 28, 1987. The goal of the project is to gain a better understanding of the transient behavior of the Capillary Pump Loop (CPL) developed and tested by the GSFC. The investigation is directed toward development of analytical models to represent the transient thermal-fluid mechanic processes occurring in different parts of the CPL engineering model. Evaluation of the available test data has been the starting point for the investigation. Based on results of this evaluation, supplementary tests will be conducted by using a CPL test system already operational in the Heat Transfer laboratory of the university. Of particular interest is the oscillatory behavior of the CPL engineering model exhibited during some of the earlier test runs conducted at NASA-GSFC and Johnson Space Center (JSC).

Kiper, Ali M.↗

The generation of capillary instabilities on a liquid jet

The coupling between imposed disturbances and capillary instabilities on a liquid jet is examined. It is shown that in most physical situations the forcing produces neutral waves, which can then turn into growing waves as the profile relaxes or may be amplified nonlinearly by a mechanism of the type considered by Akylas and Benney (1980). The effectiveness of the coupling is expressed quantitatively by numerically computed values of the 'coupling coefficient'.

Leib, S. J.↗

Verification of an analytic modeler for capillary pump loop thermal control systems

A number of computer programs have been written to model two-phase heat transfer systems for space use. These programs support the design of thermal control systems and provide a method of predicting their performance in the wide range of thermal environments of space. Predicting the performance of one such system known as the capillary pump loop (CPL) is the intent of the CPL Modeler. By modeling two developed CPL systems and comparing the results with actual test data, the CPL Modeler has proven useful in simulating CPL operation. Results of the modeling effort are discussed, together with plans for refinements to the modeler.

Schweickart, R. B.↗

The centring dynamics of a thin liquid shell in capillary oscillations

The physical mechanism governing the centring of a hollow liquid shell in capillary oscillations, which has been observed in experiments, is investigated theoretically. First, the shell is assumed to be inviscid and to have a thickness that is much less than its spherical radius. A system of one-dimensional nonlinear equations of motion is derived using a thin-sheet model. From a numerical study the nonlinear effects of the wave are found to cause the core to oscillate slowly relative to the shell while the centre of mass of the whole system remains stationary. The effects of small viscosity are then considered in an approximation. Finally the strength of the centring mechanism is compared with that of the decentring effect due to buoyancy. The findings are consistent with the limited experimental information available.

Lee, Chun P.↗

Capillary-Pumped Heat-Transfer Loop

New type of capillary-pumped heat-transfer loop primes itself at startup. Removes substantial quantities of heat like that generated by people and equipment in rooms and vehicles. Creates continuous path for its working fluid; both vapor and liquid move in same direction. Key element in operation of loop is formation of slugs of liquid, condensed from vapor and moved along loop by vapor bubbles before and after it. Both evaporator and condenser contain axial arteries carrying water. Heat entering evaporator from heat source provides energy for transport of fluid and heat. Dimensions in inches.

Source record↗

Ceramic Wick For Capillary-Pumped Heat Pipe

Fibrous ceramic wick allows choice of working fluid and high-temperature fabrication and/or operation. Wick material resists degradation at temperatures from -195 to +1,500 degrees C. Liquid refrigerant fills bore of silica/alumina wick. After flowing by capillary action through pores of wick, refrigerant evaporates from finned outer surface of wick and enters heat pipe, flowing toward condenser section.

Seidenberg, Benjamin↗

Capillary heat transport and fluid management device

A passive heat transporting and fluid management apparatus including a housing in the form of an extruded body member having flat upper and lower surfaces is disclosed. A main liquid channel and at least two vapor channels extend longitudinally through the housing from a heat input end to a heat output end. The vapor channels have sintered powdered metal fused about the peripheries to form a porous capillary wick structure. A substantial number of liquid arteries extend transversely through the wicks adjacent the respective upper and lower surfaces of the housing, the arteries extending through the wall of the housing between the vapor channels and the main liquid channel and open into the main liquid channel. Liquid from the main channel enters the artery at the heat input end, wets the wick and is vaporized. When the vapor is cooled at the heat output end, the condensed vapor refills the wick and the liquid reenters the main liquid channel.

James W Owen↗

Exploratory study of temperature oscillations related to transient operation of a Capillary Pumped Loop heat pipe

An analytical study has been conducted for better understanding of a peculiar transient behavior which was displayed in testing of a Capillary Pumped Loop (CPL) heat pipe system. During several test runs of this CPL system varying degrees of surface temperature oscillations occurred in the inlet line of the evaporators. Although several theories have been forwarded to explain this observed phenomenon, a satisfactory understanding of causes of these oscillations is still missing. The present investigation derives the conditions which lead to such oscillatory temperature behavior in evaporator inlet section of the mentioned CPL system. Stability characteristics of these temperature oscillations were investigated.

Kiper, A. M.↗

An improved high power hybrid capillary pumped loop

In order to improve performance testing, NASA's High-Power Spacecraft Thermal Management system has been modified through (1) an augmentation of heat-dissipation capacity of the condenser sink for steady-state high power operation, (2) the addition of more pressure transducers for pressure-drop monitoring in various system components, (3) the installation of pressure-contact thermocouples on the evaporators to measure heating surface temperature, (4) the provision of a coolant loop to one of the evaporator plates, (5) the placing of a transient fluid flow-monitoring load cell in the reservoir, and (6) the reorientation of the reservoir to reduce compressed vapor effects. The system is now capable of 10 hours of continuous capillary mode operation at an input power level of 20 kW.

Ku, Jentung↗

Testing of a controller for a hybrid capillary pumped loop thermal control system

A controller for a series hybrid capillary pumped loop (CPL) system that requires no moving parts does not resrict fluid flow has been tested and has demonstrated improved performance characteristics over a plain CPL system and simple hybrid CPL systems. These include heat load sharing, phase separation, self-regulated flow control and distribution, all independent of most system pressure drop. In addition, the controlled system demonstrated a greater heat transport capability than the simple CPL system but without the large fluid inventory requirement of the hybrid systems. A description of the testing is presented along with data that show the advantages of the system.

Schweickart, Russell↗