Search NASA⌕ Search

SEARCH · Search NASA

Results for “chromatography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Structural characterization and biological activity of an α-glucan from the mollusk Marcia hiantina (Lamarck, 1818)

Marcia hiantina (Mollusca, Bivalvia) (Lamarck, 1818), is an edible clam mainly distributed along the tropical coastal regions. Recent researches have demonstrated that clams can possess compounds, including polysaccharides, with a wide range of biological actions including antioxidant, immunomodulatory and antitumor activities. Here an α-glucan was isolated from M. hiantina by hot water, purified by anion exchange chromatography, and its structure was characterized by a combination of multiple nuclear magnetic resonance (NMR) methods (1D 1 H, 1 H- 1 H COSY, 1 H- 1 H TOCSY, 1 H- 1 H NOESY, 1 H- 13 C HSQC and 1 H- 13 C HSQC-NOESY spectra), gas chromatography-mass spectrometry, and high performance size exclusion chromatography (HPSEC). The analysis from NMR, monosaccharide composition, methylation analyses and HPSEC combined with multi angle light scattering (MALS) of M. hiantina-derived α-glycan confirmed a branched polysaccharide exclusively composed of glucose (Glc), mostly 4-linked in its backbone, branched occasionally at 6-positions, and having a molecular weight of ~ 570 kDa. The mollusk α-glucan was subjected to four cell-based assays: (i) viability of three cell lines (RAW264.7, HaCaT, and HT-29), (ii) activity on lipopolysaccharide (LPS)-induced prostaglandin production in RAW264.7 cells, (iii) inhibitory activities of in H 2 O 2 - and LPS-induced reactive oxygen species (ROS) production in HMC3 cells, and (iv) HaCaT cell proliferation. Furthermore, results have indicated no cytotoxicity, potent inhibition of both H 2 O 2 - and LPS-induced ROS, and potent cell proliferative activity.

59 BASIC BIOLOGICAL SCIENCES↗

Chemical changes in thirdhand smoke associated with remediation using an ozone generator

Ozonation is a common remediation approach to eliminate odors from mold, tobacco and fire damage in buildings. Little information exists to: 1) assess its effectiveness; 2) provide guidance on operation conditions; and 3) identify potential risks associated with the presence of indoor ozone and ozonation byproducts. The goal of this study is to evaluate chemical changes in thirdhand smoke (THS) aerosols induced by high levels of ozone, in comparison with THS aerosols aged under similar conditions in the absence of ozone. Samples representing different stages of smoke aging in the absence of ozone, including freshly emitted secondhand smoke (SHS) and THS, were collected inside an 18-m 3 room-sized chamber over a period of 42 h after six cigarettes were consumed. The experiments involved collection and analysis of gas phase species including volatile organic compounds (VOCs), volatile carbonyls, semivolatile organic compounds (SVOCs), and particulate matter. VOC analysis was carried out by gas chromatography/mass spectrometry with a thermal desorption inlet (TD-GC/MS), and volatile carbonyls were analyzed by on-line derivatization with dinitrophenylhydrazine (DNPH), followed by liquid chromatography with UV/VIS detection. SVOCs were extracted from XAD-coated denuders and Teflon-coated fiberglass filters in the absence of ozone. In those extracts, tobacco-specific nitrosamines (TSNAs) and other SVOCs were analyzed by gas chromatography with positive chemical ionization-triple quadrupole mass spectrometric detection (GC/PCI-QQQ-MS), and polycyclic aromatic hydrocarbons (PAHs) were quantified by gas chromatography with ion trap mass spectrometric detection (GC/IT-MS) in selected ion monitoring mode. Particulate matter concentration was determined gravimetrically. In a second experiment, a 300 mg h -1 commercial ozone generator was operated during 1 h, one day after smoke was generated, to evaluate the remediation of THS by ozonation. VOCs and volatile carbonyls were analyzed before and after ozonation. Extracts from fabrics that were exposed in the chamber before and after ozonation as surrogates for indoor furnishings were analyzed by GC/IT-MS, and aerosol size distribution was studied with a scanning mobility particle sizer. Ozone concentration was measured with a photometric detector. An estimated 175 mg ozone reacted with THS after 1 h of treatment, corresponding to 58% of the total O 3 released during that period. Fabric-bound nicotine was depleted after ozonation, and the surface concentration of PAHs adsorbed to fabric specimens decreased by an order of magnitude due to reaction with ozone, reaching pre-smoking levels. These results suggest that ozonation has the potential to remove harmful THS chemicals from indoor surfaces. However, gas phase concentrations of volatile carbonyls, including formaldehyde, acetaldehyde and acetone were higher immediately after ozonation. Ultrafine particles (UFP, in most cases with size <60 nm) were a major ozonation byproduct. UFP number concentrations peaked shortly after ozonation ended, and remained at higher-than background levels for several hours. Based on these results, minimum re-entry times after ozone treatment were predicted for different indoor scenarios. Clearly defining re-entry times can serve as a practical measure to prevent acute exposures to ozone and harmful ozonation byproducts after treatment. This study evaluated potential benefits and risks associated with THS remediation using ozone, providing insights into this technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An efficient LC-MS method for isomer separation and detection of sugars, phosphorylated sugars, and organic acids

Abstract Assessing central carbon metabolism in plants can be challenging due to the dynamic range in pool sizes, with low levels of important phosphorylated sugars relative to more abundant sugars and organic acids. Here, we report a sensitive liquid chromatography–mass spectrometry method for analysing central metabolites on a hybrid column, where both anion-exchange and hydrophilic interaction chromatography (HILIC) ligands are embedded in the stationary phase. The liquid chromatography method was developed for enhanced selectivity of 27 central metabolites in a single run with sensitivity at femtomole levels observed for most phosphorylated sugars. The method resolved phosphorylated hexose, pentose, and triose isomers that are otherwise challenging. Compared with a standard HILIC approach, these metabolites had improved peak areas using our approach due to ion enhancement or low ion suppression in the biological sample matrix. The approach was applied to investigate metabolism in high lipid-producing tobacco leaves that exhibited increased levels of acetyl-CoA, a precursor for oil biosynthesis. The application of the method to isotopologue detection and quantification was considered through evaluating 13C-labeled seeds from Camelina sativa. The method provides a means to analyse intermediates more comprehensively in central metabolism of plant tissues.

Plant Sciences↗

Evaluation of 134 Ce/ 134 La as a PET Imaging Theranostic Pair for 225 Ac α-Radiotherapeutics

225 Ac-targeted α-radiotherapy is a promising approach to treating malignancies, including prostate cancer. However, α-emitting isotopes are difficult to image because of low administered activities and a low fraction of suitable γ-emissions. The in vivo generator 134 Ce/ 134 La has been proposed as a potential PET imaging surrogate for the therapeutic nuclides 225 Ac and 227 Th. In this report, we detail efficient radiolabeling methods using the 225 Ac-chelators DOTA and MACROPA. These methods were applied to radiolabeling of prostate cancer imaging agents, including PSMA-617 and MACROPA-PEG 4 -YS5, for evaluation of their in vivo pharmacokinetic characteristics and comparison to the corresponding 225 Ac analogs. Methods: Radiolabeling was performed by mixing DOTA/MACROPA chelates with 134 Ce/ 134 La in NH 4 OAc, pH 8.0, at room temperature, and radiochemical yields were monitored by radio–thin-layer chromatography. In vivo biodistributions of 134 Ce-DOTA/MACROPA.NH 2 complexes were assayed through dynamic small-animal PET/CT imaging and ex vivo biodistribution studies over 1 h in healthy C57BL/6 mice, compared with free 134 CeCl 3 . In vivo, preclinical imaging of 134 Ce-PSMA-617 and 134 Ce-MACROPA-PEG 4 -YS5 was performed on 22Rv1 tumor–bearing male nu/nu-mice. Ex vivo biodistribution was performed for 134 Ce/ 225 Ac-MACROPA-PEG 4 -YS5 conjugates. Results: 134 Ce-MACROPA.NH 2 demonstrated near-quantitative labeling with 1:1 ligand-to-metal ratios at room temperature, whereas a 10:1 ligand-to-metal ratio and elevated temperatures were required for DOTA. Rapid urinary excretion and low liver and bone uptake were seen for 134 Ce/ 225 Ac-DOTA/MACROPA. NH 2 conjugates in comparison to free 134 CeCl 3 confirmed high in vivo stability. An interesting observation during the radiolabeling of tumor-targeting vectors PSMA-617 and MACROPA-PEG 4 -YS5—that the daughter 134 La was expelled from the chelate after the decay of parent 134 Ce—was confirmed through radio–thin-layer chromatography and reverse-phase high-performance liquid chromatography. Both conjugates, 134 Ce-PSMA-617 and 134 Ce-MACROPA-PEG 4 -YS5, displayed tumor uptake in 22Rv1 tumor–bearing mice. The ex vivo biodistribution of 134 Ce-MACROPA.NH 2 , 134 Ce-DOTA and 134 Ce-MACROPA-PEG 4 -YS5 corroborated well with the respective 225 Ac-conjugates. Conclusion: These results demonstrate the PET imaging potential for 134 Ce/ 134 La-labeled small-molecule and antibody agents. The similar 225 Ac and 134 Ce/ 134 La-chemical and pharmacokinetic characteristics suggest that the 134 Ce/ 134 La pair may act as a PET imaging surrogate for 225 Ac-based radioligand therapies.

07 ISOTOPE AND RADIATION SOURCES↗

A lipidomics platform to analyze the fatty acid compositions of non-polar and polar lipid molecular species from plant tissues: Examples from developing seeds and seedlings of pennycress (Thlaspi arvense)

The lipidome comprises the total content of molecular species of each lipid class, and is measured using the analytical techniques of lipidomics. Many liquid chromatography-mass spectrometry (LC-MS) methods have previously been described to characterize the lipidome. However, many lipidomic approaches may not fully uncover the subtleties of lipid molecular species, such as the full fatty acid (FA) composition of certain lipid classes. Here, we describe a stepwise targeted lipidomics approach to characterize the polar and non-polar lipid classes using complementary LC-MS methods. Our “polar” method measures 260 molecular species across 12 polar lipid classes, and is performed using hydrophilic interaction chromatography (HILIC) on a NH2 column to separate lipid classes by their headgroup. Our “non-polar” method measures 254 molecular species across three non-polar lipid classes, separating molecular species on their FA characteristics by reverse phase (RP) chromatography on a C30 column. Five different extraction methods were compared, with an MTBE-based extraction chosen for the final lipidomics workflow. A state-of-the-art strategy to determine and relatively quantify the FA composition of triacylglycerols is also described. This lipidomics workflow was applied to developing, mature, and germinated pennycress seeds/seedlings and found unexpected changes among several lipid molecular species. During development, diacylglycerols predominantly contained long chain length FAs, which contrasted with the very long chain FAs of triacylglycerols in mature seeds. Potential metabolic explanations are discussed. The lack of very long chain fatty acids in diacylglycerols of germinating seeds may indicate very long chain FAs, such as erucic acid, are preferentially channeled into beta-oxidation for energy production.

59 BASIC BIOLOGICAL SCIENCES↗

Mapping Influenza-Induced Posttranslational Modifications on Histones from CD8+ T Cells

T cell function is determined by transcriptional networks that are regulated by epigenetic programming via posttranslational modifications (PTMs) to histone proteins and DNA. Bottom-up mass spectrometry (MS) can identify histone PTMs, whereas intact protein analysis by MS can detect species missed by bottom-up approaches. We used a novel approach of online two-dimensional liquid chromatography-tandem MS with high-resolution reversed-phase liquid chromatography (RPLC), alternating electron transfer dissociation (ETD) and collision-induced dissociation (CID) on precursor ions to maximize fragmentation of uniquely modified species. The first online RPLC separation sorted histone families, then RPLC or weak cation exchange hydrophilic interaction liquid chromatography (WCX-HILIC) separated species heavily clad in PTMs. Tentative identifications were assigned by matching proteoform masses to predicted theoretical masses that were verified with tandem MS. We used this innovative approach for histone-intact protein PTM mapping (HiPTMap) to identify and quantify proteoforms purified from CD8 T cells after in vivo influenza infection. Activation significantly altered PTMs following influenza infection, histone maps changed as T cells migrated to the site of infection, and T cells responding to secondary infections had significantly more transcription enhancing modifications. Thus, HiPTMap identified and quantified proteoforms and determined changes in CD8 T cell histone PTMs over the course of infection.

mass spectrometry↗

Plasma-Based Ambient Desorption/Ionization Mass Spectrometry for the Analysis of Liquid Crystals Employed in Display Devices

Liquid-crystal displays (LCDs) are the most frequently used display technology worldwide these days. Due to the rather complex manufacturing process and purity requirements for the chemicals used, quality control and display failure analysis are important analytical tasks. Currently, the state-of-the-art techniques (e.g., high-performance liquid chromatography (HPLC), gas chromatography (GC) coupled to mass spectrometry (MS), time-of-flight secondary ion mass spectrometry (TOF-SIMS), or high-resolution microscopy) are costly and time-consuming. Hence, a new pathway to precisely analyze liquid-crystalline materials and LCDs in their native state is reported. A new approach for direct analysis via plasma-based ambient desorption/ionization mass spectrometry (ADI-MS) offers an inexpensive and faster alternative. In this study, direct analysis in real time (DART), the low-temperature plasma (LTP) probe, and flowing atmospheric-pressure afterglow (FAPA) ADI sources coupled to high-resolution mass spectrometry (HR-MS) are compared based on their capabilities and performance for liquid-crystal analysis. These sources enable direct analyte desorption from a sample surface at ambient conditions and ionize the vaporized analyte molecules in a subsequent step. Primarily, the ionization capabilities of the three ADI sources are compared for individual liquid-crystal standards, mixtures of liquid crystals (LCs), and complex liquid crystal/additive mixtures applied in commercially available LCDs. Furthermore, direct surface analysis from a glass substrate is also performed with ADI-MS to compare their applicability to this type of sample matrix. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and Evaluation of a Gas Chromatograph-Atmospheric Pressure Chemical Ionization Interface for an Exactive Orbitrap Mass Spectrometer

Various separation and mass spectrometric (MS) techniques have furthered our ability to study complex mixtures, and the desire to measure every analyte in a system is of continual interest. For many complex mixtures, such as the total molecular content of a cell, it is becoming apparent that no one single separation technique or analysis is likely to achieve this goal. Therefore, having a variety of tools to measure the complexity of these mixtures is prudent. Orbitrap MSs are broadly used in systems biology studies due to their unique performance characteristics. However, GC-Orbitraps have only recently become available, and instruments that can use gas chromatography (GC) cannot use liquid chromatography (LC) and vice versa. This limits small molecule analyses, such as those that would be employed for metabolomics, lipidomics, or toxicological studies. Thus, a simple, temporary interface was designed for a GC and Thermo Scientific™ Ion Max housing unit. This interface enables either GC or LC separation to be used on the same MS, an Exactive™ Plus Orbitrap, and utilizes an atmospheric pressure chemical ionization (APCI) source. The GC-APCI interface was tested against a commercially available atmospheric pressure photoionization (APPI) interface for three types of analytes that span the breadth of typical GC analyses: fatty acid methyl esters (FAMEs), polyaromatic hydrocarbons (PAHs), and saturated hydrocarbons. The GC-APCI-Orbitrap had similar or improved performance to the APPI and other reported methods in that it had a lower limit of quantitation, better signal to noise, and lower tendency to fragment analytes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of gas chromatographic pattern recognition and classification tools for compliance and forensic analyses of fuels: A review

Gas chromatography (GC) is undoubtedly the analytical technique of choice for analyzing the composition of petroleum-based fuels. Over the past twenty years, as comprehensive two-dimensional gas chromatography (GC×GC) has evolved, fuel analysis has often been highlighted in scientific reports, as their complexity allows for illustration of the impressive peak capacity gains afforded by GC×GC. Indeed, several research groups in recent years have applied GC×GC and chemometrics to demonstrate the potential of these analytical tools to address important compliance (tax evasion, tax credits, physical quality standards) and forensic (arson investigations, oil spills) applications involving fuels. None the less, routine use of GC×GC in forensic laboratories has been limited largely by (1) legal and regulatory guidelines, (2) lack of chemometrics training, and (3) concerns about the reproducibility of GC×GC. The goal of this review is to highlight recent advances in one-dimensional GC (1D-GC) and GC×GC analyses of fuels for compliance and forensic applications, in an effort to assist scientists in overcoming the aforementioned hindrances. An introduction to 1D-GC principles, GC×GC technology (column stationary phases and modulators) and several chemometric techniques will be provided. More specifically, chemometric techniques will be broken down into (1) signal pre-processing, (2) peak decomposition, identification and quantification, and (3) classification and pattern recognition. Examples of compliance and forensic applications will be discussed, with particular emphasis on the demonstrated success of the employed chemometric techniques. Overall, this review will hopefully make 1D-GC and GC×GC coupled with chemometric data analysis tools more accessible to the larger scientific community, and aid in eventual widespread standardization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The production and separation of 161 Tb with high specific activity at the University of Utah

Targeted radiotherapy (TRT) is an increasingly prominent area of research in nuclear medicine, particularly in the context of treating cancerous tumors. One radionuclide of considerable interest for TRT is terbium-161 (t 1/2 = 6.95 days), which undergoes beta emission and shares similar decay properties as 177 Lu (FDA-approved as LUTATHERA® and PLUVICTO®). Besides beta emission, 161 Tb also emits a significant number of conversion and Auger electrons further enhancing its therapeutic potential. Terbium-161 can be produced using nuclear reactors through an indirect neutron capture reaction, $^{160}_{64}$Gd(n,γ) $^{161}_{64}$Gd → (3.7 min, β – ) $^{161}_{65}$Tb, from 160 Gd targets. However, a key challenge in utilizing 161 Tb for TRT lies in effectively separating target and product materials to attain high specific activity for radiolabeling. Here, we detail the production of no-carrier added 161 Tb using low flux research reactors (mean thermal (< 0.625 eV) neutron flux: 1.356 ×10 12 n • cm –2 • s –1 ) like the University of Utah TRIGA Reactor, using enriched 160 Gd 2 O 3 targets (1.5 ± 0.3 µCi of 161 Tb per mg of 160 Gd target per hour of irradiation). We also developed a separation technique based on cation exchange and extraction chromatography, suitable for mCi level irradiations with targets exceeding 200 milligrams. In a simulated full-scale irradiation, 161 Tb was successfully isolated from large mass targets using cation exchange (AG 50W-X8, with 2-hydroxyisobutyric acid at 70 mM, pH 4.75) and extraction chromatography (LN Resin, 0.5 – 0.75 M HNO 3 ) methods. Here, this resulted in high apparent molar activities of [ 161 Tb]Tb-DOTA (113 ± 3 MBq/nmol), demonstrating high purity 161 Tb relevant for potential future preclinical applications.

161Tb↗

Different reactivity to glutathione but similar tumor cell toxicity of chalcones and their quinolinone analogues

Non-enzyme catalyzed nucleophilic addition of reduced glutathione (GSH) onto two open-chain sulfonamide chalcones and two quinolinone-chalcone hybrids were studied to investigate the relationship between tumor cell cytotoxic activities and GSH-reactivities of the compounds. The consumption of the chalcones or the quinolinone-chalcone hybrids due to conjugation with GSH was evaluated by analytical high-performance liquid chromatography, and the formed diastereomeric adducts were identified by liquid chromatography–mass spectrometry. When the reaction was conducted with the open-chain chalcones, the equilibria were shifted towards formation of the respective GSH-conjugates. On the other hand, the cyclic chalcone derivatives with the quinolinone moiety were found to equilibrate to mixtures containing predominantly the reactants despite the strong electron withdrawing group present in the B-ring of the compounds. The observed opposite behavior can be rationalized by reduced thiol-reactivity of the quinolinone-chalcone hybrids and fast decomposition of their GSH-conjugates. A combined X-ray diffraction and theoretical approach were used to explain the observed difference in the reactivities towards GSH. However, structural differences did not influence tumor cell (SF-295, PC-3 and HCT-116) cytotoxicity of the evaluated compounds. Accordingly, the altered GSH-reactivity seems to be not a determining factor in the tested tumor cell cytotoxic activity of the investigated compounds.

60 APPLIED LIFE SCIENCES↗

Evaluation of SR/ TEVA/ TRU triple stack for separation of activation products

A rapid method to separate Ta, Po, Au, Pt, and W from a sample containing mixed fission and activation products was developed using three commercially available extraction chromatography resins stacked in series. When the separation was tested using all the target activation products, even those with short half-lives were measurable. Finally, combining multiple extraction chromatography resin cartridges in tandem allows for multiple short-lived activation products to be separated from one sample addition without the complication of multiple steps.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Novel insight into the kinetics of amide bond glycolysis for nylon-6 depolymerization

Chemical recycling of nylon-6 to short-chain oligomers and monomer ε-caprolactam via catalytic glycolysis is a potential solution for plastic waste remediation. Here, in this work, the kinetics of amide bond glycolysis (with ethylene glycol) in nylon-6 and the model compound N-phenethyl-3-phenylpropanamide (M1) were evaluated at 473 K in the presence of the cyclic amidine catalyst 1,5,7-triazabicyclo[4.4.0]dec-5-ene. Rates of polymer glycolysis were determined by the time-dependent shift in molecular weight distribution, whereas rates of M1 glycolysis were determined using liquid chromatography. The similarity of the first-order rate constants for glycolysis of nylon-6 and M1 at 473 K with 0.03 M amidine catalyst (5 mol% relative to amide bonds), 1.22 × 10 −5 s −1 and 2.18 × 10 −5 s −1 , respectively, confirmed the suitability of M1 as a model compound for nylon-6 glycolysis. Similar rates of glycolysis in the presence of other cyclic amidine catalysts as well as sodium methoxide revealed little influence of base strength. Glycolysis rates were unexpectedly non-linear in catalyst loading and deactivation occurred with long reaction times, presumably by non-selective decomposition of products as detected by liquid chromatography.

Depolymerization rate and rate constant↗

Machine learning-based ethylene concentration estimation, real-time optimization and feedback control of an experimental electrochemical reactor

With the increase in electricity supply from clean energy sources, electrochemical reduction of carbon dioxide (CO 2 ) has received increasing attention as an alternative source of carbon-based fuels. As CO 2 reduction is becoming a stronger alternative for the clean production of chemicals, the need to model, optimize and control the electrochemical reduction of the CO 2 process becomes inevitable. However, on one hand, a first-principles model to represent the electrochemical CO 2 reduction has not been fully developed yet because of the complexity of its reaction mechanism, which makes it challenging to define a precise state-space model for the control system. On the other hand, the unavailability of efficient concentration measurement sensors continues to challenge our ability to develop feedback control systems. Gas chromatography (GC) is the most common equipment for monitoring the gas product composition, but it requires a period of time to analyze the sample, which means that GC can provide only delayed measurements during the operation. Moreover, the electrochemical CO 2 reduction process is catalyzed by a fast-deactivating copper catalyst and undergoes a selectivity shift from the product-of-interest at the later stages of experiments, which can pose a challenge for conventional control methods. To this end, machine learning (ML) techniques provide a potential approach to overcome those difficulties due to their demonstrated ability to capture the dynamic behavior of a chemical process from data. Motivated by the above considerations, we propose a machine learning-based modeling methodology that integrates support vector regression and first-principles modeling to capture the dynamic behavior of an experimental electrochemical reactor; this model, together with limited gas chromatography measurements, is employed to predict the evolution of gas-phase ethylene concentration. The model prediction is directly used in a proportional-integral (PI) controller that manipulates the applied potential to regulate the gas-phase ethylene concentration at energy-optimal set-point values computed by a real-time process optimizer (RTO). Specifically, the RTO calculates the operation set-point by solving an optimization problem to maximize the economic benefit of the reactor. Finally, suitable compensation methods are introduced to further account for the experimental uncertainties and handle catalyst deactivation. The proposed modeling, optimization, and control approaches are the first demonstration of active control for a CO 2 electrolyzer and contribute to the automation and scale-up efforts for electrified manufacturing of fuels and chemicals starting from CO 2 .

42 ENGINEERING↗

Temperature-dependent changes in gas chromatographic separation metrics for trihexyl(tetradecyl)phosphonium-based ionic liquid stationary phases and comparison to conventional polysiloxane stationary phases

Here, to assess whether the trihexyl(tetradecyl)phosphonium chloride ([P 66614 + ][Cl - ]) ionic liquid (IL), employed as a gas chromatographic stationary phase, exhibits temperature-dependent phase transitions or structural heterogeneity, retention thermodynamics for probe molecules of varied chemical structure were investigated by gas chromatography (GC) over the temperature range of 25 to 64 °C using van’t Hoff analysis. All van’t Hoff plots for n-alkanes (C8–C12) and other probe analytes were linear, indicating the absence of detectable phase-transition behavior. The [P 66614 + ][Cl - ] IL was further compared with the [P 66614 + ] bis[(trifluoromethyl)sulfonyl]imide ([P 66614 + ][NTf 2 - ]) IL and commercial polysiloxane stationary phases in terms of temperature-dependent resolution behavior and chromatographic selectivity over the temperature range of 28–52 °C. The resolution factors of analytes in mixtures obtained using gas chromatography–mass spectrometry (GC–MS) and the summation of resolution values decreased smoothly with temperature on both IL stationary phases and on the dimethylphenylcyano-substituted polymeric stationary phase (OV-1701), whereas the poly(50% diphenyl/50% dimethyl siloxane) stationary phase (SPB-50) exhibited irregularities in its temperature-dependent summation of resolution profile, showing a distinct maximum in the temperature range of 34–40 °C. Selectivity values for the IL stationary phases were largely determined by the anion, with the [P 66614 + ][Cl - ] IL providing enhanced separation between polar and aromatic analytes, while the [P 66614 + ][NTf 2 - ] IL favored dispersive and π-π interactions that resulted in a reversal of elution order for some aliphatic–aromatic and alkyne-containing analyte pairs. Capillary columns prepared using different surface activation methods and coated with identical [P 66614 + ][Cl - ] IL stationary phase showed indistinguishable temperature-dependent trends in summation of resolution value and selectivity. An evaluation of analyte-specific selectivity provides insight into the characteristic separation behavior of the stationary phases and enables identification of analyte classes that are more efficiently separated on the [P 66614 + ]-based IL stationary phases compared to conventional stationary phase materials.

Chromatographic selectivity↗

Apolipoprotein A-I modulates HDL particle size in the absence of apolipoprotein A-II

Human high-density lipoproteins (HDLs) are a complex mixture of structurally related nanoparticles that perform distinct physiological functions. We previously showed that human HDL containing apolipoprotein A-I (APOA1) but not apolipoprotein A-II (APOA2), designated LpA-I, is composed primarily of two discretely sized populations. Here, we isolated these particles directly from human plasma by antibody affinity chromatography, separated them by high-resolution size-exclusion chromatography and performed a deep molecular characterization of each species. The large and small LpA-I populations were spherical with mean diameters of 109 Å and 91 Å, respectively. Unexpectedly, isotope dilution MS/MS with [ 15 N]-APOA1 in concert with quantitation of particle concentration by calibrated ion mobility analysis demonstrated that the large particles contained fewer APOA1 molecules than the small particles; the stoichiometries were 3.0 and 3.7 molecules of APOA1 per particle, respectively. MS/MS experiments showed that the protein cargo of large LpA-I particles was more diverse. Human HDL and isolated particles containing both APOA1 and APOA2 exhibit a much wider range and variation of particle sizes than LpA-I, indicating that APOA2 is likely the major contributor to HDL size heterogeneity. We propose a ratchet model based on the trefoil structure of APOA1 whereby the helical cage maintaining particle structure has two “settings”—large and small—that accounts for these findings. This understanding of the determinants of HDL particle size and protein cargo distribution serves as a basis for determining the roles of HDL subpopulations in metabolism and disease states.

59 BASIC BIOLOGICAL SCIENCES↗

Formation of Ligand Clusters on Multimodal Chromatographic Surfaces

Multimodal chromatography is a powerful tool which uses multiple modes of interaction, such as charge and hydrophobicity, to purify protein-based therapeutics. In this work, we performed molecular dynamics simulations of a series of multimodal cation-exchange ligands immobilized on a hydrophilic self-assembled monolayer surface at the commercially relevant surface density (1 ligand/nm2). We found that ligands that were flexible and terminated in a hydrophobic group had a propensity to aggregate on the surface, while less flexible ligands containing a hydrophobic group closer to the surface did not aggregate. For aggregating ligands, we report this resulted in the formation of a surface pattern that contained relatively large patches of hydrophobicity and charge whose sizes exceeded the length scale of the individual ligands. On the other hand, lowering the surface density to 1 ligand/3 nm 2 reduced or eliminated this aggregation behavior. In addition, the introduction of a flexible linker (corresponding to the commercially available ligand) enhanced cluster formation and allowed aggregation to occur at lower surface densities. Further, the use of flexible linkers enabled hydrophobic groups to collapse to the surface, reducing their accessibility. Finally, we developed an approach for quantifying differences in the observed surface patterns by calculating distributions of the patch size and patch length. This clustering phenomenon is likely to play a key role in governing protein–surface interactions in multimodal chromatography. This new understanding of multimodal surfaces has important implications for developing improved predictive models and designing new classes of multimodal separation materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative insights for diagnosing performance bottlenecks in lithium–sulfur batteries

Lithium–sulfur (Li–S) batteries hold significant promise for electric vehicles and aviation due to their high energy density and cost-effectiveness. However, understanding the root causes of performance degradation remains a formidable challenge, as the interplay of multiple factors obscures key failure mechanisms. A major limitation has been the inability to quantify soluble sulfur species within practical detection limits accurately and to correlate electrochemical processes with associated physical inventory changes. Here, we introduce the high-performance liquid chromatography-ultraviolet spectroscopy and gas chromatography sequential characterization (HUGS) toolkit, capable of precisely quantifying seven distinct sulfur and polysulfide species at concentrations as low as 40 ppb. HUGS has been successfully applied to practical coin and pouch cells without requiring cell modification. Furthermore, our self-developed software, Dr HUGS, enhanced the data analysis speed by over 30 times, enabling multi-source data integration and delivering comprehensive analysis results within minutes. Using HUGS, we identify significant capacity losses from inactive lithium and sulfur during initial cycles and sulfide-rich solid–electrolyte interphase (SEI) formation on the anode during later cycles. Notably, our findings reveal that soluble polysulfides have minimal contributions to capacity loss, challenging long-standing assumptions. Moreover, HUGS demonstrates that constant-pressure setups in Li–S pouch cells improve compositional uniformity compared to constant-gap configurations. For sulfurized polyacrylonitrile (SPAN) cathodes, unique issues such as non-sulfide SEI formation and lithium pulverization are observed, which can be mitigated through localized high-concentration electrolytes to enhance lithium inventory retention. By enabling precise quantification of critical inventory components, HUGS provides transformative insights into failure mechanisms across various electrolytes and cathode chemistries, guiding rational design strategies for next-generation energy storage systems.

25 ENERGY STORAGE↗