Heating rate distributions at Mach 10 on a circular body earth-to-orbit transport vehicle
A 0.0055-scale model of a single-stage-to-orbit transport vehicle with a circular body configuration was tested at Mach 10 to obtain heat transfer measurements and surface flow patterns. Phase-change paint and oil-flow tests were performed in the Langley 31-Inch Mach-10 Tunnel at angles of attack from 20 through 40 deg in 5-deg increments. Heat-transfer coefficient data are given for all angles of attack, and detailed oil-flow photographs are presented for windward and leeward surfaces at 25 and 40 deg angle of attack. Heating was found to similar to that previously determined for the Space Shuttle Orbiter, so that existing thermal protection systems would appear to be adequate for the proposed circular-body configurations.