Search NASA⌕ Search

SEARCH · Search NASA

Results for “cleanup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Identifying Controlling Variables for Mercury Vapors in Alpha-4 at Y-12: Two Year Data Collection Update

Multiple sensor packages were deployed at Alpha-4 by SRNL, in collaboration with United Cleanup Oak Ridge LLC (UCOR), to monitor mercury vapor concentrations and meteorological parameters. These sensors collected data, inside and outside of the legacy-use facility, for approximately two years. Though data gaps still exist, particularly in colder months, several controlling variables were identified that govern mercury vapor concentrations within Alpha-4. Temperature, barometric pressure gradients, humidity, and wind speed have been identified as controlling variables. A strong positive correlation was seen between mercury vapor concentrations and temperature which generally followed diurnal fluctuations. Temperatures below approximately 10 degrees Celsius did not show any spikes above the PEL, indicating more work can be performed at any time during the winter months – more data should be collected to confirm consistency in this finding. Additionally, spikes in mercury vapor concentrations above that of the permissible exposure limit (PEL; 100 µg/m 3 ) occurred primarily in late afternoon or evening/overnight hours (between 3 PM and 6 AM), which suggests D&D operations might be best scheduled during morning or daytime hours prior to the late afternoon. However, a limited number of spikes did occur outside of the identified window, although this may be attributed to disturbances in air flow and mercury vapor release from work activities performed inside of the Alpha-4 building. The analysis conducted allows for a strong predictive capability for estimating mercury vapor concentrations based upon accurate meteorological parameters. Still, additional data collection, particularly in the winter months, could help to strengthen the predictive power and validate the identified data trends. Further, increased temporal resolution could also help to better characterize the incipient stages of the increases and decreases in the mercury vapor concentration. Continued monitoring support by SRNL at Y-12 is underway at Alpha-4 to further close remaining data gaps and support deactivation and decommissioning work. Within a collaborative effort with UCOR, the SRNL team is collecting mercury vapor data to study the efficacy of a novel mercury suppressant, FerroBlack® which was recently deployed at Alpha-4. In addition, modifications to the current monitoring setup to increase measurement resolution is also being investigated.

54 ENVIRONMENTAL SCIENCES↗

Comparison of RESRAD-ONSITE and PRG/DCC Calculators and Application to Navy Environmental Media

The purpose of this project is to develop an improved Navy-wide approach for estimating risk and calculating cleanup goals for radiologically impacted environmental media (e.g., soils). This comparative analysis focused on the new features added (or improved) to the PRG/DCC Calculators since the 2015 comparison study (Yu et al. 2015a). RESRAD-ONSITE code Version 7.2 and the PRG/DCC Calculators available on the USEPA website between January and June of 2024 were used.

54 ENVIRONMENTAL SCIENCES↗

Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan

The Pantex Plant Ogallala Aquifer and Perched Groundwater Contingency Plan has been developed in accordance with the requirements identified in the: • Interagency Agreement for the Pantex Superfund Site, Article 8.5 Work to be Performed, • Compliance Plan Provision of Hazardous Waste Permit No. 50284, and • Record of Decision for Groundwater, Soil, and Associated Media, Pantex Plant. A Long‐Term Monitoring System Design has been designed to monitor conditions in the perched groundwater including changes in the perched aquifer as a result of implementing the response actions. Monitoring is required for verifying the effectiveness of perched groundwater response actions (i.e., conditions in the perched aquifer are being affected as intended) and for confirming that the perched aquifer and Ogallala Aquifer characterization as defined in the Resource Conservation and Recovery Act Facility Investigation Report and the Corrective Measure Studies/Feasibility Study remains accurate. If monitoring results obtained through the monitoring network identify an unexpected condition or deviation, contingent actions will be considered and implemented as necessary to ensure continued protection of the Ogallala Aquifer and human health and the environment. Potential deviations to expected technology performance may be encountered for each of the four primary response actions that compose the selected remedy for perched groundwater; Playa 1 Pump and Treat System, Southeast Area Pump and Treat System, Southeast Area In‐Situ Bioremediation System (comprised of the Southeast In‐Situ Bioremediation System Original System, Southeast Area In‐Situ Bioremediation System Extension System, Offsite In‐Situ Bioremediation System, Perchlorate/Chromium ISB, Northeast ISB and County Road 8 ISB), and Zone 11 In‐Situ Bioremediation System. Monitoring will also be conducted to determine if there are deviations to the expected characterization, e.g., contaminants not expected as a result of the RCRA Facility Investigation characterization. Deviations to expected conditions in the Ogallala Aquifer could also be encountered if the response actions in the perched groundwater are not performing as expected, i.e., preventing contaminants from migrating to the Ogallala Aquifer. Currently, Pantex has begun investigation of detections of high explosives above groundwater protection standards in wells on the Texas Tech University property and a plume that is moving to the northeast from that area. Due to those detections, this Plan recognizes the fact that future detections in the Ogallala will be focused on first‐ time detections of analytes. After a remedy is determined, this Plan will require modification to address-deviations and contingent actions. This Plan was developed to identify the contingent actions necessary to mitigate impacts resulting from deviations to site conditions or response action performance. The Plan defines the environmental problem being addressed by the response actions, clarifies the expected conditions and objectives of the response actions, and identifies the potential deviations to the response actions (due to site conditions or technology performance) that could be encountered. The deviations were evaluated to determine the likelihood of occurrence, potential impact, and time to respond to avoid impact. The Plan also identifies the monitoring outlined in the Long‐Term Monitoring System Design Report (Consolidated Nuclear Security, 2024) and Sampling Analysis Plan (PanTeXas Deterrence, 2024) that will be used to detect the deviations. Lastly, the Plan specifies the contingent actions that could be implemented in response to the deviations. Because each response focuses on a discrete portion of the perched aquifer and contaminant plume, each response action has a different set of expected conditions, and therefore differing impacts from deviations to the site and technology expectations. As a result, the contingent actions are identified for each response action and potential deviation including specific constituents, location, and conditions. If deviations are encountered that impact the ability of the response action to meet performance objectives, the contingent actions will be focused on ensuring the response action can meet the performance objective. Contingent actions may be implemented as interim actions (ISMs/removal actions) in accordance with the Record of Decision, Interagency Agreement, and Hazardous Waste Permit‐50284, if warranted by the specific circumstances. For deviations to site characterization expected conditions, the contingent action will focus on determination of the source of the deviation, determination of the appropriate response, and evaluation of additional work to be completed. However, if the deviation to characterization impacts the performance of the response action, the contingent action will again focus on ensuring performance objectives can be met. Early source term removals and cleanup actions have been implemented to protect the Ogallala Aquifer. Because of these actions and based on modeling results, the expected conditions in the Ogallala Aquifer are that constituents of concern will not be detected above the Groundwater Protection Standards (GWPSs) nor will they reach potential points of exposure above the GWPS. The primary deviation of concern for the Ogallala is if constituents are detected in the Ogallala Aquifer near or above GWPSs. If it occurs, this change in expected conditions would require further evaluation of site and contaminant characteristics to determine an appropriate course of action. The evaluation would include additional monitoring, source identification, implementation of interim protective measures (if necessary), and delineation of extent. These evaluations are necessary to determine an appropriate response action for the Ogallala. The primary goal of the Plan is to provide for the continued protection of the Ogallala Aquifer and the health of its consumers. In recognition, this Plan presents a flexible and rational approach for making future decisions associated with confirming the change in perched and Ogallala aquifer conditions and identifying a response (technical activities, changes to response actions, regulatory oversight, and public involvement).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Management of the Three Mile Island, Unit 2, Accident Corium and Severely Damaged Fuel Debris

The Three Mile Island, Unit Two (TMI-2) pressurized water reactor core melted down in 1979 due to an untimely combination of maintenance problems that led to a loss of feedwater, followed by a series of operational misunderstandings and errors. The melted core recovery process required development of a wide array of tools. After approximately three years of water management and other cleanup actions, the first views of the core revealed a much higher degree of damage than previously expected. Approximately 62 metric tons of the core had melted, leaving only 42 of the 177 fuel assemblies standing with a majority of rods intact. The core to be recovered was composed of loose debris and a solidified mass of formerly molten fuel. Robotic tools that had been designed for the task were of limited effectiveness due to the range of material types and phases. Over a period of several years, the central melt was broken up, primarily by use of a core-boring drill originally designed to acquire samples through the depth of the debris field. The broken pieces were loaded into specially designed debris canisters by use of long-handled pick-and-place tools and suctioned into baffled knockout canisters using an airlift vacuum system. A remotely operable underwater plasma arc torch was developed for removal of the lower core support structure to be able to retrieve the fuel pieces and secondary melt that had accumulated on the bottom reactor vessel head. Canister design played a central role in defining the initial retrieval process and later affected transportation, interim wet and its current interim dry storage. Due to concerns about the potential for radiolysis of residual water in the debris and other canister material, the canisters were fitted with hydrogen recombiner catalyst units to prevent a buildup of flammable gas and potential pressurization. To confirm the effectiveness of the recombiners during shipping, eight dewatered canisters were kept sealed for up to 205 days with periodic sampling of the headspace gas. The highest hydrogen value (9 vol%) was observed in a canister held for 147 days while the longest stored canister resulted in a 5% hydrogen concentration. The oxygen concentration never exceeded 0.5 %, and the primary backfill was >80% argon, meaning there was no flammability risk. Radiolytic hydrogen was also observed in wet pool storage, where the vented canisters discharged a portion of the water backfill as a result of gas production. The 344 canisters (268 fuel debris, 62 filter, and 12 knockout type) were dewatered, loaded in groups of seven into a double barrier shipping cask, and transported to the U.S. Department of Energy site in Idaho for 10 years of pool storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Review of Carbon-14 Removal by Ion Exchange Resins and Potential Remediation Application in the 100-K Area

During operations at the U.S. Department of Energy Hanford Site, releases of chemical and radioactive waste resulted in contamination of the soil and groundwater beneath portions of the site, including inadvertent releases of carbon-14 in the 100-K Area. Ongoing environmental cleanup efforts in the 100-K Area are focused on hexavalent chromium [Cr(VI)] and thus have not yet addressed the two carbon-14 groundwater plumes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

U.S. Efforts in Support of Examinations at Fukushima Daiichi - September 2024 Meeting Notes

Information obtained from Fukushima Daiichi Nuclear Power Station (Daiichi) is required to inform future Decontamination and Decommissioning (D&D) activities, improving the ability of the Tokyo Electric Power Company Holdings, Incorporated (TEPCO Holdings) to characterize potential hazards and to ensure the safety of workers involved with cleanup activities. This information also has important implications for the safety and operation of U.S. Commercial nuclear power plants. A collaborative U.S. and Japanese effort was initiated in 2014 by the Department of Energy Office of Nuclear Energy to identify Daiichi examination needs and evaluate recent Daiichi examination data to address these needs. This document summarizes information presented at and findings, action items, and recommendations by U.S. and Japanese experts in reactor safety and plant operations during the September 2024 Forensics Effort meeting. Significant safety insights were obtained in several areas: system and component performance, radionuclide surveys and sampling, debris end-state location, combustible gas effects, and plant operations and maintenance. In addition to reducing uncertainties and knowledge gaps in severe accident modeling progression, these insights continue to be used to assess whether additional updates are needed in guidance for severe accident prevention, mitigation, and emergency planning. Furthermore, Daiichi-related activities, such as code modeling improvements and analysis, testing, and new technology deployment efforts, have the potential to offer additional safety and economic benefits to the operating fleet and new light water reactor (LWR) and non-LWR designs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Physical and Hydraulic Properties of RCRA Borehole Samples from the Hanford Site : Final Report, Fiscal Years 2023-2024

Sediment from 44 core samples collected from Resource Conservation and Recovery Act (RCRA) boreholes drilled in the 200 East and 200 West areas of the Hanford Site were characterized for physical and hydraulic properties (Table S.1). Characterization data included gravimetric water contents and matric potentials, grain-size distributions, saturated hydraulic conductivity, water retention characteristics, and unsaturated hydraulic conductivity. These properties provide site-specific data and parameters that can be used in subsurface flow and contaminant transport models to assess the transport and fate of contaminants in the vadose zone and underlying aquifer systems. The analyzed core samples come from specific areas and depth intervals at the Hanford Site that were targeted for sampling to address data gaps identified by site contractors (Khaleel 2020). X-ray computed tomography (XCT) was used to evaluate the general textural characteristics of the samples and to determine which samples to use for further physical and hydraulic property characterization. Subsequent sample selection was determined by consensus after review of the XCT images by Pacific Northwest National Laboratory, Central Plateau Cleanup Company, and INTERA staff.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automated Air Sealing Demonstration: Denver Federal Center Building 40

This project aimed to demonstrate building airtightness achieved by automated air sealing in a commercial building setting. The automated air sealing demonstrated in this project uses a modified blower door to pressurize and distribute the sealing aerosol to achieve the required building airtightness. To demonstrate this technology, Building 40 at the Denver Federal Center, a federally owned campus under the jurisdiction, custody and control of the U.S. General Services Administration (GSA), was selected for testing (Figure 2). This building is currently undergoing several retrofit projects, including increasing insulation, installing high-performance windows, and adding advanced equipment, control systems, and automated air sealing. This demonstration project involved installing automated air sealing and measuring the improvements in the building's airtightness. The automated air sealing was installed over two days by AeroBarrier, the vendor. An external blower door test contractor measured the airtightness of the demonstration space before and after air sealing. The new airtightness value and the percentage increase in airtightness were used to evaluate the energy savings potential of automated air sealing. These airtightness values were used to compute the energy savings and CO 2 emissions reduction for different climate zones, building types, and initial airtightness conditions. In addition, the heating, ventilation and air conditioning (HVAC) load reduction attributable to the reduced building air leakage was studied. This study included research to determine the cost and time reduction of automated air sealing. Finally, the automated air sealing performance was evaluated qualitatively using a focus group discussion that included GSA and Bristol, the general contractor. The installation has shown the demonstration site, with a floor size of 4,462 ft 2 , air leakage has reduced by more than 50% in less than 7 hours, including preparation, site sealing, and cleanup. The performance objectives were classified as quantitative or qualitative based on the evaluation metrics used to assess the project’s success. The key performance objectives for this project were the level of airtightness achieved, the time and cost required to perform the sealing, and the HVAC load reduction attributable to air sealing. Table 1 shows the quantitative performance objectives.

42 ENGINEERING↗

Technology and Innovation Roadmap

This Technology and Innovation Roadmap outlines the Hanford Tank Waste Operations & Closure, LLC (H2C) strategic approach for advancing the Hanford Tank Waste Treatment Mission (HTWTM) through technology development. Our focus is on addressing technology needs that address risks, enhance efficiency, ensure worker safety, and uphold environmental standards. This Roadmap identifies key technology initiatives essential for the successful completion of the Hanford Site tank waste cleanup. Updated annually, it incorporates insights from the U.S. Department of Energy (DOE), the Integrated Tank Disposition Contractor (ITDC) H2C, recognized national lab experts, and fieldwork specialists. The Roadmap includes approximately 100 technology elements, each detailed in Technology Element Description Summaries (TEDS) and summarized in catalog sheets. These elements are crucial for aligning technology development activities with mission objectives across the HTWTM. With the initiation of the Direct-Feed Low-Activity Waste (DFLAW) program and the operation of the Tank Side Cesium Removal (TSCR) system, our focus now shifts to the support of scaled up production in East Area; applying similar and exploring new treatment alternatives to West Area Tank Waste; and advancing retrieval, delivery and treatment technologies for waste managed as high-level waste (HLW) across the Hanford tank farms. This transition is reflected in the technology and maturation (TM&E) charts, which highlight the evolving technology priorities. This document serves as a guide for navigating the challenges and opportunities in technology development at the Hanford Site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Overview on Current Activities of Conduction-Cooled SRF Accelerators and their Applications

When Nb3Sn was reintroduced to the SRF community as an alternative to pure niobium, one key motivation has been to reduce the cryogenic requirements of new and existing accelerators by shifting from 2 K to 4 K operation. Meanwhile, a variety of implementations beyond research machines are being explored. The combination of Nb3Sn with conventional cryocoolers, enabling cryogen-free operation, has paved the way for the development of compact, standalone systems suitable for applications far beyond research, such as enhancing the durability of synthetics via crosslinking or sterilizing food and medical equipment, as well as environmental cleanup when it comes to decontaminating liquid and solid waste material. So, while fundamental R&D continues to refine Nb3Sn resonators, exploring improvements such as replacing the niobium substrate with copper, parallel research efforts are investigating how the increased beam power provided by SRF could expand the commercial use of electron beams. This presentation aims to deliver a comprehensive overview of ongoing research efforts to harness the benefits of SRF through Nb3Sn and conduction cooling.

Vennekate, John [Thomas Jefferson National Acceler↗

Vertical Characterization of Flow and Contaminant Concentration in New Hanford Extraction Wells

Effective groundwater remediation should focus on high-concentration, low-permeability zones within the aquifer, as these areas often present significant challenges to contaminant removal. Characterizing the vertical distribution of contamination in an aquifer is therefore critical for optimizing and monitoring pump-and-treat (P&T) systems to meet target cleanup timelines. Flow patterns driven by hydraulic gradients and variations in permeability are described to provide insight into contaminant mass removal from long-screened wells. The objective of this multi-phase work is to provide actionable recommendations for improving remedy performance monitoring and P&T operations, which ongoing evaluations will address. This report summarizes the preliminary results of vertical flow and contaminant distribution monitoring in new extraction wells at the Hanford Site.

54 ENVIRONMENTAL SCIENCES↗

MatLib-1.2: Nuclear Material Properties Library

The U.S. Nuclear Regulatory Commission (NRC) uses the computer code Fuel Analysis under Steady-state and Transients (FAST) to model steady-state and transient fuel behavior to support regulatory decisions. FAST relies on a material properties library (MatLib) that contains the thermal and mechanical properties of the nuclear materials and coolants of interest to support the US commercial nuclear industry. MatLib contains properties for a variety of nuclear fuels, cladding and other structural materials, gases, and coolants. In this document, material property correlations for the materials contained within MatLib are presented and discussed. When available, comparisons are made between the material property correlations and available data. Additionally, uncertainties are quantified on the material proper- ties, which is then used by the NRC to support uncertainty quantification for best-estimate plus uncertainty safety evaluation reviews. This document describes MatLib-1.2, which was updated from MatLib-1.1 to include cleanup of the code for streamlined calls to MatLib from the main FAST source code, and to enable easier readability of the code by developers that maintain and enhance the FAST code. The results of MatLib did not change between MatLib-1.1 and MatLib-1.2; however, the source code changes warranted incrementing the minor numbering of the software version number. The changes may result in faster execution times of FAST-1.2 as compared to FAST-1.1. This document is one of a series of documents on FAST; the other documents detail the models used by FAST as well as its integral assessment to experiments and commercial data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial Uncertainty Analysis of Carbon Tetrachloride Contamination and Remediation in the Ringold A and Lower Mud Units at the Central Plateau

The long-term effectiveness of groundwater cleanup at the Hanford Site Central Plateau depends on predictive models that can capture key uncertainties in contaminant fate and transport. Carbon tetrachloride (CCl 4 ), a persistent and toxic compound, presents particular challenges due to variability in degradation rates, uncertainty in initial plume distribution, and subsurface heterogeneity. These uncertainties directly influence plume persistence, migration pathways, and remedy performance, and thus must be systematically evaluated to support long-term remediation planning. To address these gaps, a large-scale Monte Carlo analysis was conducted using the Plateau to River (P2R) model framework. The modeling approach parameterized three primary uncertainty factors: (1) degradation rate, (2) initial plume distribution, and (3) hydraulic conductivity. Degradation was represented as a first-order process, with half-lives ranging from 70 to 700 years. Initial plume distributions were created using a geostatistical simulation method (sgsim), which generates many equally plausible versions of how contaminants might be distributed underground. From this, 100 different scenarios were mapped onto the P2R grid. Variability in hydraulic conductivity was represented in a similar way, with 100 scenarios each for the Ringold Lower Mud and Ringold A units (layers 6 and 7), based on fitted exponential variograms and conditioned to well data. In total, more than 1000 realizations were simulated to assess plume behavior under uncertainty. Results demonstrate that degradation kinetics exert the strongest control over plume persistence: Shorter half-lives produced rapid mass reduction, while longer half-lives yielded persistent plumes with limited attenuation. A nonlinear response was observed, with steep mass reductions at half-lives greater than 200 years and near-linear declines beyond this threshold, reflecting interactions between degradation and pumping. The initial plume distribution strongly influenced early transport patterns, with broader sources generating larger plume footprints, although pump-and-treat operations constrained plume migration to managed areas. By comparison, hydraulic conductivity variability in the Ringold units had only a secondary influence, modifying spreading behavior without altering the dominant migration pathways governed by source configuration and hydraulic controls. Overall, the analysis highlights that uncertainty in degradation rate and initial plume configuration are the primary drivers of variability in plume predictions, while conductivity heterogeneity plays a limited role. These findings underscore the need for improved site-specific data on degradation processes and source characterization to enhance the reliability of long-term performance assessments and to better inform remedial decision-making at the Central Plateau.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2024 ASER Summary: Annual Site Environmental Report Summary (Rev. 2)

The Laboratory’s Governing Policy for the Environment: (1) We are committed to act as stewards of our environment to achieve our mission in accordance with all applicable environmental requirements. (2) We set continual improvement objectives and targets, measure and document our progress, and share our results with our workforce, sponsors, and the public. (3) We reduce our environmental risk through legacy cleanup, pollution prevention, and long-term management programs.

54 ENVIRONMENTAL SCIENCES↗

Hydrogen production from high-volume organic construction and demolition wastes

The Energy & Environmental Research Center (EERC) has partnered with Simonpietri Enterprises, LLC (SEL) with the objective of developing an integrated waste preparation, gasification, and syngas cleanup process capable of using a high-volume, negative-value, highly contaminated feedstock consisting of construction and demolition (C&D) waste to economically produce 99+% pure hydrogen. The target is to achieve $\$$1/kg H2 at a modular scale ranging from 5- to 50-MWe-equivalent size by testing the gasification of organic C&D debris containing treated waste lumber and construction materials, permanently sequestering contaminants into the ash. C&D debris waste is one the largest-volume waste streams in the United States; is already aggregated and available across the country, lending itself to hub operations; and has fewer alternatives for energy conversion than are available for coal, biomass, and municipal solid waste because of contamination from treated lumber and other construction materials.

08 HYDROGEN↗

Summary of Analytical Services for the Hanford Site Radionuclide NESHAP Program

This document is a summary of the point source analytical requirements used to demonstrate compliance for the Department of Energy (DOE) Hanford Site operations with 40 Code of Federal Regulations (CFR) Part 61, “National Emission Standards for Hazardous Air Pollutants,” (NESHAP) Subpart H, “National Emission Standards for Emissions of Radionuclides Other Than Radon From Department of Energy Facilities,” and the Washington Administrative Code (WAC) 246-247, “Radiation Protection – Air Emissions.” This reference collects information from multiple source documents and is not intended to create, supersede, replace or over-ride any existing contractual, DOE, federal or state statutes, regulations, compliance agreements, orders, permits, licenses or other requirements. The requirement source document governs where any difference may exist. The Hanford Mission Integration Solutions (HMIS) Environmental organization has been contracted by DOE to manage and report data collected from the sampling and monitoring of radioactive air emissions point sources, colloquially called stacks. The Environmental organization coordinates the analyses and reporting of samples collected at various facilities across the Hanford Site. These facilities operate approximately 52 stacks that require sampling, monitoring or estimating radioactive air emissions. The stacks are operated by Bechtel National, Inc. (BNI), Central Plateau Cleanup Company (CPCCo), Hanford Tank Waste Operations & Closure (H2C), Hanford Laboratory Management and Integration (HLMI), and Pacific Northwest National Laboratory (PNNL). Stack samples from CPCCo, HLMI and H2C facilities are collected by the operating contractor staff, delivered to HMIS, and then shipped to an offsite contracted laboratory for analyses. The field and laboratory sample data uploaded into the Sample Management and Analytical Results Tracking (SMART) database are used to calculate sample volumes and concentrations. Sample concentrations are evaluated for compliance with federal and state regulations, permits, and license requirements. The SMART database also calculates total curies released for sampled point sources and stacks. Point source effluent concentrations and releases are published annually in publicly available reports. The BNI and PNNL operate several DOE-Hanford Field Office (HFO) stacks subject to the requirements of 40 CFR 61, Subpart H and WAC 246-247. The concentrations, curies released and dose modeling evaluation for these stacks are included in the DOE-HFO annual radionuclide NESHAP report. The sample collection, analyses and emissions estimates for these stacks are outside the scope of HMIS contracted responsibilities and not addressed further in this document.

54 ENVIRONMENTAL SCIENCES↗

Geophysical Imaging of Flow and Transport (GIFT): FY24 Status Report

The GIFT (Geophysical Imaging of Flow and Transport) system will improve predictive capabilities as a platform for collecting multi-physical (MP) time-lapse datasets from well-controlled laboratory experiments. This will enable more accurate prediction of multi-phase fluid flow during delivery and transport of insitu remedial amendments as important components of the overall Hanford Site cleanup mission. Design and construction of the GIFT system, which consists of a meter-scale test cell and a network of custom gas circulation and analysis systems, was accomplished in fiscal year (FY) 2024, with plans to add liquid circulation to the system and use this new capability for multi-phase deep vadose experiments starting in FY25.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Site Revegetation Monitoring Report for Fiscal Year 2022

This report describes the monitoring of areas revegetated by various contractors on the Hanford Site. Revegetation sites include those revegetated by the River Corridor Closure Contractor and CH2M Hill Plateau Remediation Company that were transitioned to Mission Support Alliance (MSA) in 2017. These sites, along with sites revegetated by MSA between 2017 and 2020, were transitioned to Hanford Mission Integration Solutions (HMIS) in 2021. HMIS performs revegetation monitoring activities for these transitioned sites and for sites revegetated by HMIS and other contractors in subsequent years to determine revegetation site success. This report contains data collected in 2022 documenting the recovery of revegetation areas associated with the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 cleanup of National Priorities List waste sites and restoration of lands disturbed by ongoing mission activities at the Hanford Site in Richland, Washington. It contains vegetation monitoring data for 53 sites selected to be representative sites for areas planted between the years of fiscal year (FY) 2007 and FY 2022.

54 ENVIRONMENTAL SCIENCES↗