Search NASA⌕ Search

SEARCH · Search NASA

Results for “collimators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Self-imaging-based laser collimation testing technique

Laser collimation is required in many experiments based on lasers. Some laser experiments demand a high quality of collimation, e.g., the optical coherent processor, image transformer, and Fourier transform generator. A device is required to test the collimation of lasers in such experiments. We have suggested a modification in existing collimation testing techniques by which sensitivity can be improved. Theoretical analysis and experimental results demonstrate twice the improvement in sensitivity when used with previous techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental and Numerical Studies on the Proposed Application of Hollow Electron Beam Collimation for the LHC at CERN

This thesis work was carried out in the framework of the U.S. LHC Accelerator Research Program (USLARP), a collaboration between the European Organization for Nuclear Research (CERN) and the U.S. Department of Energy. The first half of the work was completed at Fermilab (USA), the location of the Tevatron, a proton-antiproton collider and the second largest particle collider in the world. The second half was completed at CERN (Switzerland), the location of the largest proton collider in the world (Large Hadron Collider (LHC)). This thesis characterizes a Hollow Electron Beam (HEB) for possible usage at the LHC to enhance its collimation through Hollow Electron Beam Lenses (HEBLs). Collimation is a long established principle in high energy particle accelerators. Hollow Electron Beam Collimation (HEBC) aims to enhance current collimation systems by controlling diffusion of primary halo particles into the limiting aperture. It works on the principle of a transverse radial electric field that kicks the primary halo particles outwards upon each pass in a multi-pass system. The transverse field is produced by a HEB that is coaxially aligned with the accelerator beam, producing a negligible electric field in the center and a strong transverse electric field at amplitudes higher than the inner radius of the electron beam. Ideally, halo particles are affected without perturbation of the beam core. One of the main advantages of this system is to decrease the dependence on instantaneous loss spikes and beam jitter. A solid experimental basis of HEBC was accumulated at the Tevatron. The application of this technique at the LHC is now under investigation. The aim of this thesis is to present a preliminary report to support a future optimal conceptual design report. It characterizes the available hardware in order to facilitate the design of a Hollow Electron Gun (HEG) for the LHC, characterizes the effect on beam diffusion by determining the transverse electric fields of the electron beam and initiates 3D simulations in order to determine the effect of the HEBL on the beam core. Experiments were conducted in the Tevatron Electron Lens Test Stand (TELTS) at Fermi National Accelerator Lab (Fermilab) (USA) in the lower Linear Accelerator (LINAC) gallery.

43 PARTICLE ACCELERATORS↗

EPICS Controlled Collimator for Controlling Beam Sizes in HIPPO

Controlling the beam spot size and shape in a diffraction experiment determines the probed sample volume. The HIPPO - High-Pressure-Preferred Orientation– neutron time-offlight diffractometer is located at the Lujan Neutron Scattering Center in Los Alamos National Laboratories. HIPPO characterizes microstructural parameters, such as phase composition, strains, grain size, or texture, of bulk (cm-sized) samples. In the current setup, the beam spot has a 10 mm diameter. Using a collimator, consisting of two pairs of neutron absorbing boron-nitride slabs, horizontal and vertical dimensions of a rectangular beam spot can be defined. Using the HIPPO robotic sample changer for sample motion, the collimator would enable scanning of e.g. cylindrical samples along the cylinder axis by probing slices of such samples. The project presented here describes implementation of such a collimator, in particular the motion control software. We utilized the EPICS (Experimental Physics Interface and Control System) software interface to integrate the collimator control into the HIPPO instrument control system. Using EPICS, commands are sent to commercial stepper motors that move the beam windows.

43 PARTICLE ACCELERATORS↗

MCNP modelling of the Thermo SPA3 with Tungsten (Rees model) collimator

A Thermo Model SPA3 2”x2” NaI probe fitted with a Tungsten collimator has been modelled using MCNP6. The collimator was assumed to be machinable Tungsten which typically includes Ni and Fe. Various ratios of these additives are used in industry and for the purposes of these calculations the collimator was assumed to contain 7% Ni and 3% Fe with a density of 17.0 g/cm 3 . The dimensions of the collimator were based on measurements taken by Mike Fanning. The above detector model was used, in a manner similar to the approach described in LA-UR-19-32358, to calculate photopeak count rates per unit activity per unit area (i.e. cpm per pCi/cm 2 ) conversion factors for various contamination scenarios.

61 RADIATION PROTECTION AND DOSIMETRY↗

WNR Facility Flight Path 90L Advanced Collimation Development

In November 2020, an advanced neutron beam transport and collimation system was installed and commissioned at flight path (FP) 90L within the Weapons Neutron Research (WNR) facility. This new collimation system was developed as a replacement for the legacy neutron collimation present at WNR FP90L. The need for this upgrade, design of this collimation system, installation at the experimental flight path, and results of this recent effort will be detailed.

43 PARTICLE ACCELERATORS↗

Coronal Jet Collimation by Nonlinear Induced Flows

Our objective is to study the collimation of solar jets by nonlinear forces corresponding to torsional Alfvén waves together with external forces. We consider a straight, initially non-rotating, untwisted magnetic cylinder embedded in a plasma with a straight magnetic field, where a shear between the internal and external flows exists. By implementing magnetohydrodynamic theory and taking into account the second-order thin flux tube approximation, the balance between the internal nonlinear forces is visualized. The nonlinear differential equation containing the ponderomotive, magnetic tension, and centrifugal forces in the presence of the shear flow is obtained. The solution presents the scale of influence of the propagating torsional Alfvén wave on compressive perturbations. Explicit expressions for the compressive perturbations caused by the forces connected to the torsional Alfvén wave show that, in the presence of a shear flow, the magnetic tension and centrifugal forces do not cancel each other’s effects as they did in its absence. This shear flow plays in favor of the magnetic tension force, resulting in a more efficient collimation. Regarding the ponderomotive force, the shear flow has no effect. The phase relations highlight the interplay of the shear flow and the plasma- β . As the shear flow and plasma- β increase, compressive perturbation amplitudes emerge. We conclude that the jet collimation due to the torsional Alfvén wave highly depends on the location of the jet. The shear flow tightens the collimation as the jet elevates up to the solar corona.

79 ASTRONOMY AND ASTROPHYSICS↗

Collimator of multiple plates with axially aligned identical random arrays of apertures

A collimator is disclosed for examining the spatial location of distant sources of radiation and for imaging by projection, small, near sources of radiation. The collimator consists of a plurality of plates, all of which are pierced with an identical random array of apertures. The plates are mounted perpendicular to a common axis, with like apertures on consecutive plates axially aligned so as to form radiation channels parallel to the common axis. For near sources, the collimator is interposed between the source and a radiation detector and is translated perpendicular to the common axis so as to project radiation traveling parallel to the common axis incident to the detector. For far sources the collimator is scanned by rotating it in elevation and azimuth with a detector to determine the angular distribution of the radiation from the source.

Hoover, R. B.↗

Diffraction effects on angular response of X-ray collimators

Angular responses have been measured for X-ray collimators with half-widths ranging from minutes of arc down to 10 arcsec. In the seconds-of-arc range, diffraction peaks at off-axis angles can masquerade as side lobes of the collimator angular response. Measurements and qualitative physical arguments lead to a rule of thumb for collimator design; namely, the angle of first minimum in the Fraunhofer single-slit diffraction pattern should be less than one-fourth of the collimator geometrical full-width at half-maximum intensity.

Blake, R. L.↗

Generation of a parallel X-ray beam and its use for testing collimators

A technique is described, by which a glass strip may be bent to match any curve of large radius of curvature, to a high degree of accuracy, so that it may be used as a glancing incidence X-ray or extreme ultraviolet optical element. The desired match is obtained by applying the optimum combination of end couples and by varying the cross-sectional moment of inertia along the length of the strip. A particular case, that of a parabola for use as a laboratory X-ray collimator, is considered in detail. The analysis predicts that a collimation of one or two arc seconds should be obtainable in practice, with simple and inexpensive apparatus. A prototype collimator to be used for the testing of space payloads using geometric (McGrath) collimators is described and laboratory results presented.

Underwood, J. H.↗

Multiprism collimator

A special purpose optical collimator system which generates multiple collimated light beams with precisely related angular separation of the beams, is comprised of a stack of relatively flat plate-like refracted prisms in the form of wedges. Each prism has a specified angular deviation, mounted on top of one another in a fixture which holds the wedges so that they are adapted to operate at minimum angular deviation and thus are relatively insensitive to rotational and angular charges. A collimated sources of monochromatic light, generated for example by a helium-neon laser and a collimated beam expander, provides a common incident beam to the wedges whereupon a number equally spaced emergent beams are provided.

Minott, P. O.↗

Two normal incidence collimators designed for the calibration of the extreme ultraviolet explorer

Two Dall-Kirkham, normal incidence collimators have been designed to calibrate the imaging properties of the Extreme Ultraviolet Explorer over the wavelength region from 114 to 2000 A. The mirrors of the short-wavelength, 25-cm diameter collimator are superpolished Zerodur which have been multilayer coated for optimal reflectivity at 114 A. The mirrors of the long-wavelength, 41.25-cm diameter collimator are gold coated Zerodur for high reflectance above 300 A. The design, performance, and future use of these collimators in the extreme ultra-violet is discussed.

Jelinsky, Sharon R.↗

Carbon nanotube collimator fabrication and application

Apparatus, methods, systems and devices for fabricating individual CNT collimators. Micron size fiber coated CNT samples are synthesized with chemical vapor deposition method and then the individual CNT collimators are fabricated with focused ion beam technique. Unfocused electron beams are successfully propagated through the CNT collimators. The CNT nano-collimators are used for applications including single ion implantation and in high-energy physics, and allow rapid, reliable testing of the transmission of CNT arrays for transport of molecules.

Chow, Lee↗

Collimator with attachment mechanism and system

A self-aligning collimator for a radiation imaging device that is secured and aligned through the use of a plurality of small magnets. The collimator allows for the rapid exchange, removal, or addition of collimators for the radiation imaging device without the need for tools. The accompanying method discloses the use of magnets and accompanying magnetic fields to align and secure collimators in a radiation imaging assembly.

47 OTHER INSTRUMENTATION↗

Monolithic collimator and energy analyzer for ion spectrometry

Disclosed are various examples related to ion or particle spectrometry utilizing a monolithic collimator and energy analyzer. In one example, a particle selection device includes a single substrate including a curved channel energy analyzer section and a straight channel collimator section, wherein particles pass through the collimator section and enter the energy analyzer section of the substrate. The channel outlets in the collimator section are aligned with the channel inlets of the energy analyzer section. Electric and/or magnetic fields can be applied across the channels of the energy analyzer for ion or particle discrimination. A particle detector at the outlet of the energy analyzer section can provide indications of detected ions and/or particles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Collimation and tagging instrumentation for the GlueX Photon Beamline

A new high energy polarized photon source is being constructed for the GlueX experiment at Jefferson Lab. Linear polarization is obtained using coherent bremsstrahlung from an oriented diamond radiator. By collimating the photon beam to a fraction of the characteristic bremsstrahlung angle $m_e/E_0$, linear polarization of 40\% is obtained at a photon energy of 9~GeV, for an incident electron beam of 12~GeV. Active stabilization of the photon beam spot on the collimator face is required in order to establish and maintain the alignment of the beam on the collimator axis with the required degree of accuracy. A photon beam centroid monitor has been developed for this purpose, based on the design of an electron beam halo detector that was invented for use at SLAC 30 years ago. Beam tests of this device in Hall B at 6 GeV show that it has the required bandwidth and sensitivity to be used in an active feedback loop in the electron beam steering controls. Such a feedback circuit is capable of locking the Hall D photon beam on the Hall D collimator with the required accuracy for GlueX at frequencies up to 1~kHz, over a wide range in beam current.

Jones, Richard↗

Real-Time Target Position Estimation Using Stereoscopic Kilovoltage/Megavoltage Imaging and External Respiratory Monitoring for Dynamic Multileaf Collimator Tracking

Purpose: To develop a real-time target position estimation method using stereoscopic kilovoltage (kV)/megavoltage (MV) imaging and external respiratory monitoring, and to investigate the performance of a dynamic multileaf collimator tracking system using this method. Methods and Materials: The real-time three-dimensional internal target position estimation was established by creating a time-varying correlation model that connected the external respiratory signals with the internal target motion measured intermittently using kV/MV imaging. The method was integrated into a dynamic multileaf collimator tracking system. Tracking experiments were performed for 10 thoracic/abdominal traces. A three-dimensional motion platform carrying a gold marker and a separate one-dimensional motion platform were used to reproduce the target and external respiratory motion, respectively. The target positions were detected by kV (1 Hz) and MV (5.2 Hz) imaging, and external respiratory motion was captured by an optical system (30 Hz). The beam-target alignment error was quantified as the positional difference between the target and circular beam center on the MV images acquired during tracking. The correlation model error was quantified by comparing a model estimate and measured target positions. Results: The root-mean-square errors in the beam-target alignment that had ranged from 3.1 to 7.6 mm without tracking were reduced to <1.5 mm with tracking, except during the model building period (6 s). The root-mean-square error in the correlation model was submillimeters in all directions. Conclusion: A novel real-time target position estimation method was developed and integrated into a dynamic multileaf collimator tracking system and demonstrated an average submillimeter geometric accuracy after initializing the internal/external correlation model. The method used hardware tools available on linear accelerators and therefore shows promise for clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electromagnetic Real-Time Tumor Position Monitoring and Dynamic Multileaf Collimator Tracking Using a Siemens 160 MLC: Geometric and Dosimetric Accuracy of an Integrated System

Purpose: Dynamic multileaf collimator tracking represents a promising method for high-precision radiotherapy to moving tumors. In the present study, we report on the integration of electromagnetic real-time tumor position monitoring into a multileaf collimator-based tracking system. Methods and Materials: The integrated system was characterized in terms of its geometric and radiologic accuracy. The former was assessed from portal images acquired during radiation delivery to a phantom in tracking mode. The tracking errors were calculated from the positions of the tracking field and of the phantom as extracted from the portal images. Radiologic accuracy was evaluated from film dosimetry performed for conformal and intensity-modulated radiotherapy applied to different phantoms moving on sinusoidal trajectories. A static radiation delivery to the nonmoving target served as a reference for the delivery to the moving phantom with and without tracking applied. Results: Submillimeter tracking accuracy was observed for two-dimensional target motion despite the relatively large system latency of 500 ms. Film dosimetry yielded almost complete recovery of a circular dose distribution with tracking in two dimensions applied: 2%/2 mm gamma-failure rates could be reduced from 59.7% to 3.3%. For single-beam intensity-modulated radiotherapy delivery, accuracy was limited by the finite leaf width. A 2%/2 mm gamma-failure rate of 15.6% remained with tracking applied. Conclusion: The integrated system we have presented marks a major step toward the clinical implementation of high-precision dynamic multileaf collimator tracking. However, several challenges such as irregular motion traces or a thorough quality assurance still need to be addressed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of a Lanthanum Bromide Detector and a New Conception Collimator for Radiopharmaceuticals Molecular Imaging in Oncology

We have realized and tested a new-design compact gamma camera for high resolution SPET (Single Photon Emission Tomography), and small animals' radio-pharmaceutical molecular imaging. The camera is based on a 'continuous' Lanthanum tri-Bromide crystal, and a new Low Energy (LE) collimator. The crystal is interfaced to a 2x2 array of Hamamatsu-H8500 position sensitive photo-multipliers. The lead collimator features parallel hexagonal 1.0 mm holes, 18 mm length, 0.2 mm septa and 10x10 cm{sup 2} detection area. It was newly designed to fully exploit the high spatial resolution a Lanthanum crystal may provide. To better evaluate its role, we have compared our camera to three other systems with similar crystals and photomultipliers, but employing traditional collimators, either pinhole or parallel. The new camera seems to be complementary to pinhole systems and shows a very attractive trade-off between spatial resolution and detection area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗