Search NASA⌕ Search

SEARCH · Search NASA

Results for “composition of the lunar atmosphere”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

166 records · Page 10

Overview of NASA's Ocean Color Instrument Solar Calibration Architecture, Pre-Launch Tests and Preliminary On-Orbit Results

Launched in February 2024, the PACE mission represents NASA’s next investment in ocean biology, clouds, and aerosol data records. A key feature of PACE is the inclusion of an advanced satellite radiometer known as the Ocean Color Instrument (OCI), a global mapping radiometer that combines multispectral and hyperspectral remote sensing. Like its predecessors, OCI will provide two day global coverage of TOA radiances. Unlike its predecessors, OCI will cover a spectral range from 340nm to 2260nm. Below 900nm, OCI will include two spectrometers that continuously span the ultraviolet to 600nm and 600nm to near-infrared spectral regions to provide hyperspectral radiances sampled every 2.5 nm, with a bandwidth of 5 nm for each channel. Wavelengths above 900nm are measured in seven discrete multispectral bands of varying bandwidths, six of which are at similar wavelengths to those on heritage missions to support both atmospheric and ocean color applications. Nominal spatial resolution is similar to the SeaWiFS instrument with 1050 m at nadir. As for SeaWiFS, the pixel size increases due to a ~20 degree tilt and as a function of scan angle. Variations in the radiometric sensitivity of each OCI channel over time will be monitored by solar diffuser measurements for short term instrument gain adjustments and independent lunar measurements for trend adjustments of long time periods, similar to the approach employed for the VIIRS instrument [4]. The OCI flight-unit was built at NASA’s Goddard Space Flight Center. At the time of this writing, OCI has completed on-orbit commissioning activities and normal science operations have begun. A key aspect of the OCI architecture is the capability to trend absolute and relative calibration changes over the course of mission life with solar calibration. Every 24 hours, the PACE spacecraft performs an inertial hold as the ground track nears the North Pole which orients a Quasi-Volume Diffuser (QVD) mounted on OCI towards the sun. By knowing the irradiance of the sun and the reflectivity of the target, the absolute radiance at the input to the OCI aperture can be computed as OCI scans the target. The allowable absolute uncertainty budget for each solar calibration measurement is 1.6% 1-sigma below 900nm at beginning of life (BOL) and the allowable relative uncertainty budget is ~0.26% 1-sigma. The Solar Calibration Assembly (SCA) consists of three targets selectable via a single mechanism which also opens a door. The targets consist of a Daily Bright Target (DBT), Monthly Bright Target (MBT), and Daily Dim Target (DDT). The bright targets are quartz QVDs with the monthly target being used to track the degradation of the daily target. The dim target is used to track CCD linearity using Progressive Time-Delay Integration (PTDI). A composite baffle is attached to the SCA housing aperture to block Earth shine and stray light from the spacecraft. The SCA assembly is mounted to a view port ~90° from OCI nadir. This paper provides an overview of driving solar calibration requirements, error-budgets and early trade studies which drove the solar calibration assembly (SCA) architecture and on-orbit maneuver. Measurements of the diffuser Bidirectional Reflectance Distribution Function (BRDF) at TNO, Netherlands and GSFC are briefly described. Optical modelling and test results at the sub-system and instrument level are included. Finally, preliminary measurements on-orbit are compared to pre-launch predictions.

ocean color↗

Coronagraphic Observations of the Lunar Sodium Exosphere 2018-2019

Remote observations of the lunar sodium corona have been obtained with the Goddard Lunar Coronagraph located at the Winer Observatory in Sonoita, Arizona. We previously reported the results of observations in the spring, 2017, observing season (Killen et al., 2019). We report herein the results of the 2018–2019 observing campaign. We show definitive effects on the corona - the extended lunar sodium exosphere above 150 km from the surface - of enhanced ion flux onto the Moon as measured by the ARTEMIS ElectroStatic Analyzer. The three observations in this dataset with the largest column abundances are associated with entrance of the Moon into the magnetosheath. The enhancement in the exosphere due to ion flux is not long-lived after the enhanced ion influx decreases, confirming the findings of Killen et al., 2012. The column abundance is greatest at both the dawn and dusk terminators as predicted and simulated by Smyth and Marconi, 1995. The cause of the increased scale height at the terminators is consistent with radiation pressure acceleration anti-sunward. We report a shallow decline of column abundance with increasing latitude which is also consistent with radiation pressure acceleration. Most of our measured scale heights are on the order of 800–1800 km, increasing at high latitudes, consistent with the data set published in Killen et al., 2019. Although the intensity extrapolated to the surface decreases with latitude, the scale height increases with latitude, so that the exospheric column decreases more slowly with increasing latitude than does a cosine function.

moon↗

Variable Pressure - Scanning Electron Microscopy (VP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Miniature Variable Pressure - Scanning Electron Microscopy (MVP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗