Search NASA⌕ Search

SEARCH · Search NASA

Results for “computerized procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Identification of the feeding arteries of hepatocellular carcinomas by performing dual arterial phase CT during pre-transarterial chemoembolization angiography

Purpose: This study evaluated the usefulness of performing dual arterial phase computed tomography (CT) during pre-transarterial chemoembolization (TACE) angiography for identifying the feeding arteries of hepatocellular carcinomas (HCC). Materials and methods: Dual arterial phase CT was performed during pre-TACE angiography in 73 patients with 139 HCC. Ten HCC underwent this procedure twice, so the total number of examined HCC was 149. Early and late arterial phase images were obtained 6 seconds after injection of an iodinated contrast material serially during a single breath-hold. The feeding artery was defined as the branch of the hepatic artery that was connected to the enhanced areas of the tumor. For HCC that could not be visualized on the early arterial phase images, fusion images superimposing the early and late arterial phase images were constructed. Furthermore, technical success defined as successful catheterization of the subsegmental or more distal feeding artery was evaluated. Results: The feeding artery was correctly identified on dual arterial phase CT in 146 of the 149 tumors (98.0%). In two HCC, the feeding arteries could not be identified due to severe motion artifacts, and in one, due to the presence of anastomosis between the right and left hepatic arteries. Catheterization of the subsegmental feeding artery was successful in all TACE procedures (technical success rate: 100%). Conclusion: Performing dual arterial phase CT during angiography appears to be useful for identifying the feeding arteries of HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ipsilateral Dual-Site, Same-Sitting Percutaneous Lung Biopsy: A Feasibility Study

PurposePatients with thoracic malignancies often have more than one site of pulmonary, nodal or pleural disease within one hemithorax. In addition, large heterogeneous lesions may comprise distinct, mixed pathological entities. Histological analysis of these lesions can alter tumour staging and treatment options. We investigated the feasibility, safety and benefit of performing image-guided percutaneous lung biopsy (PLB) of two lesions in the same hemithorax at a single sitting.Materials and MethodsTen consecutive outpatients with two or more potential disease foci within the same hemithorax were analysed over a 15-month period. The mean age of the patients was 66 years (range 46–81 years). Patients underwent CT-guided coaxial 20G core biopsy of both lesions, with separate coaxial punctures for each lesion. Patients were managed as per established local institution ambulatory lung biopsy protocol using small-calibre Heimlich-valve chest drain (HVCD) to treat significant post-PLB pneumothorax in an outpatient setting. Data regarding lesion characteristics, diagnoses and complications were recorded.ResultsAll 10 patients (n = 20 biopsies, 100% technical success) received informative histological diagnosis on both lesions. This altered management in all cases. Although a high rate of pneumothorax occurred (60%; 6/10), only two of these patients required treatment with HVCD. No other significant complications occurred in those patients with small asymptomatic pneumothoraces or those that required HVCD placement.ConclusionsDual-site lung biopsy, performed as a single procedure, is potentially a safe and effective technique for diagnosing patients with multiple thoracic lesions, and can provide useful staging information to guide patient management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative effectiveness of coronary CT angiography vs stress cardiac imaging in patients following hospital admission for chest pain work-up: The Prospective First Evaluation in Chest Pain (PERFECT) Trial

Background: Because the frequency of cardiac event rates is low among chest pain patients following either performance of coronary CT angiography (CCTA) or stress testing, there is a need to better assess how these tests influence the central management decisions that follow from cardiac testing. The present study was performed to assess the relative impact of CCTA vs stress testing on medical therapies and downstream resource utilization among patients admitted for the work-up of chest pain. Methods: The admitted patients were randomized in a 1:1 ratio to either cardiac imaging stress test or CCTA. Primary outcomes were time to discharge, change in medication usage, and frequency of downstream testing, cardiac interventions, and cardiovascular re-hospitalizations. We randomized 411 patients, 205 to stress testing, and 206 to CCTA. Results: There were no differences in time to discharge or initiation of new cardiac medications at discharge. At 1 year follow-up, there was no difference in the number of patients who underwent cardiovascular downstream tests in the CCTA vs stress test patients (21% vs 15%, P = .1) or cardiovascular hospitalizations (14% vs 16%, P = .5). However, there was a higher frequency of invasive angiography in the CCTA group (11% vs 2%, P = .001) and percutaneous coronary interventions (6% vs 0%, P < .001). Conclusions: Randomization of hospitalized patients admitted for chest pain work-up to either CCTA or to stress testing resulted in similar discharge times, change in medical therapies at discharge, frequency of downstream noninvasive testing, and repeat hospitalizations. However, a higher frequency of invasive coronary angiography and revascularization procedures were performed in the CCTA arm. (ClinicalTrials.gov number, NCT01604655.)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-institutional Validation Study of Commercially Available Deformable Image Registration Software for Thoracic Images

Purpose: To assess the accuracy of the commercially available deformable image registration (DIR) software for thoracic images at multiple institutions. Methods and Materials: Thoracic 4-dimensional (4D) CT images of 10 patients with esophageal or lung cancer were used. Datasets for these patients were provided by DIR-lab ( (dir-lab.com)) and included a coordinate list of anatomic landmarks (300 bronchial bifurcations) that had been manually identified. Deformable image registration was performed between the peak-inhale and -exhale images. Deformable image registration error was determined by calculating the difference at each landmark point between the displacement calculated by DIR software and that calculated by the landmark. Results: Eleven institutions participated in this study: 4 used RayStation (RaySearch Laboratories, Stockholm, Sweden), 5 used MIM Software (Cleveland, OH), and 3 used Velocity (Varian Medical Systems, Palo Alto, CA). The ranges of the average absolute registration errors over all cases were as follows: 0.48 to 1.51 mm (right-left), 0.53 to 2.86 mm (anterior-posterior), 0.85 to 4.46 mm (superior-inferior), and 1.26 to 6.20 mm (3-dimensional). For each DIR software package, the average 3-dimensional registration error (range) was as follows: RayStation, 3.28 mm (1.26-3.91 mm); MIM Software, 3.29 mm (2.17-3.61 mm); and Velocity, 5.01 mm (4.02-6.20 mm). These results demonstrate that there was moderate variation among institutions, although the DIR software was the same. Conclusions: We evaluated the commercially available DIR software using thoracic 4D-CT images from multiple centers. Our results demonstrated that DIR accuracy differed among institutions because it was dependent on both the DIR software and procedure. Our results could be helpful for establishing prospective clinical trials and for the widespread use of DIR software. In addition, for clinical care, we should try to find the optimal DIR procedure using thoracic 4D-CT data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-206-05: A Comparison of Head Phantoms Used for Dose Determination in Imaging Procedures

Purpose: To determine similarities and differences between various head phantoms that might be used for dose measurements in diagnostic imaging procedures. Methods: We chose four frequently used anthropomorphic head phantoms (SK-150, PBU-50, RS-240T and Alderson Rando), a computational patient phantom (Zubal) and the CTDI head phantom for comparison in our study. We did a CT scan of the head phantoms using the same protocol and compared their dimensions and CT numbers. The scan data was used to calculate dose values for each of the phantoms using EGSnrc Monte Carlo software. An .egsphant file was constructed to describe these phantoms using a Visual C++ program for DOSXYZnrc/EGSnrc simulation. The lens dose was calculated for a simulated CBCT scan using DOSXYZnrc/EGSnrc and the calculated doses were validated with measurements using Gafchromic film and an ionization chamber. Similar calculations and measurements were made for PA radiography to investigate the attenuation and backscatter differences between these phantoms. We used the Zubal phantom as the standard for comparison since it was developed based on a CT scan of a patient. Results: The lens dose for the Alderson Rando phantom is around 9% different than the Zubal phantom, while the lens dose for the PBU-50 phantom was about 50% higher, possibly because its skull thickness and the density of bone and soft tissue are lower than anthropometric values. The lens dose for the CTDI phantom is about 500% higher because of its totally different structure. The entrance dose profiles are similar for the five anthropomorphic phantoms, while that for the CTDI phantom was distinctly different. Conclusion: The CTDI and PBU-50 head phantoms have substantially larger lens dose estimates in CBCT. The other four head phantoms have similar entrance dose with backscatter hence should be preferred for dose measurement in imaging procedures of the head. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP1-04: Pseudo-In-Vivo Dose Verification of a New Mono-Isocentric Technique for the Treatment of Multiple Brain Metastases

Purpose: To validate dose calculation and delivery accuracy of a recently introduced mono-isocentric technique for the treatment of multiple brain metastases in a realistic clinical case. Methods: Anonymized CT scans of a patient were used to model a hollow phantom that duplicates anatomy of the skull. A 3D printer was used to construct the phantom of a radiologically bone-equivalent material. The hollow phantom was subsequently filled with a polymer gel 3D dosimeter which also acted as a water-equivalent material. Irradiation plan consisted of 5 targets and was identical to the one delivered to the specific patient except for the prescription dose which was optimized to match the gel dose-response characteristics. Dose delivery was performed using a single setup isocenter dynamic conformal arcs technique. Gel dose read-out was carried out by a 1.5 T MRI scanner. All steps of the corresponding patient’s treatment protocol were strictly followed providing an end-to-end quality assurance test. Pseudo-in-vivo measured 3D dose distribution and calculated one were compared in terms of spatial agreement, dose profiles, 3D gamma indices (5%/2mm, 20% dose threshold), DVHs and DVH metrics. Results: MR-identified polymerized areas and calculated high dose regions were found to agree within 1.5 mm for all targets, taking into account all sources of spatial uncertainties involved (i.e., set-up errors, MR-related geometric distortions and registration inaccuracies). Good dosimetric agreement was observed in the vast majority of the examined profiles. 3D gamma index passing rate reached 91%. DVH and corresponding metrics comparison resulted in a satisfying agreement between measured and calculated datasets within targets and selected organs-at-risk. Conclusion: A novel, pseudo-in-vivo QA test was implemented to validate spatial and dosimetric accuracy in treatment of multiple metastases. End-to-end testing demonstrated that our gel dosimetry phantom is suited for such QA procedures, allowing for 3D analysis of both targeting placement and dose.

60 APPLIED LIFE SCIENCES↗

Comparison of Balloon-Occluded Retrograde Transvenous Obliteration (BRTO) Using Ethanolamine Oleate (EO), BRTO Using Sodium Tetradecyl Sulfate (STS) Foam and Vascular Plug-Assisted Retrograde Transvenous Obliteration (PARTO)

PurposeTo compare the clinical outcomes of balloon-occluded retrograde transvenous obliteration (BRTO) using ethanolamine oleate (EO), BRTO using sodium tetradecyl sulfate (STS) foam, and vascular plug-assisted retrograde transvenous obliteration (PARTO).Materials and MethodsFrom April 2004 to February 2015, ninety-five patients underwent retrograde transvenous obliteration for gastric varices were analyzed retrospectively. BRTO with EO was performed in 49 patients, BRTO with STS foam in 25, and PARTO in 21. Among them, we obtained follow-up data in 70 patients. Recurrence of gastric varices was evaluated by follow-up endoscopy or CT. Medical records were reviewed for the clinical efficacy. Statistical analyses were performed by Kaplan–Meier method, Chi-square, Fisher’s, and Kruskal–Wallis tests.ResultsTechnical and clinical success was 94.7 %. As major complications, a hemoglobinuria and a death due to disseminated intravascular coagulation (DIC) were occurred in two patients with BRTO using EO. Recurrence occurred more frequently in PARTO group (P < 0.05). Recurrence occurred in three patients in BRTO using EO group and four patients in PARTO group with 3.2 and 32.8 % of each expected 1-year recurrence rates. There was no recurrence in BRTO using STS group. Abdominal pain occurred more frequently in BRTO using EO than BRTO using STS foam and PARTO (P < 0.05). Procedure time of PARTO was shorter than two conventional BRTOs (P < 0.05).ConclusionsBRTO using STS foam or PARTO is better than BRTO using EO for treatment of gastric varices in terms of complication or procedure time. However, PARTO showed frequent recurrence of gastric varices during the long-term follow-up rather than BRTO.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies

PurposeWhen using laser guidance for cone-beam computed tomography (CBCT)-guided needle interventions, planned needle paths are visualized to the operator without the need to switch between entry- and progress-view during needle placement. The current study assesses the effect of laser guidance during CBCT-guided biopsies on fluoroscopy and procedure times.Materials and MethodsProspective data from 15 CBCT-guided biopsies of 8–65 mm thoracic and abdominal lesions assisted by a ceiling-mounted laser guidance technique were compared to retrospective data of 36 performed CBCT-guided biopsies of lesions >20 mm using the freehand technique. Fluoroscopy time, procedure time, and number of CBCT-scans were recorded. All data are presented as median (ranges).ResultsFor biopsies using the freehand technique, more fluoroscopy time was necessary to guide the needle onto the target, 165 s (83–333 s) compared to 87 s (44–190 s) for laser guidance (p < 0.001). Procedure times were shorter for freehand-guided biopsies, 24 min versus 30 min for laser guidance (p < 0.001).ConclusionThe use of laser guidance during CBCT-guided biopsies significantly reduces fluoroscopy time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of oncological {sup 18}F-FDG PET/CT imaging based on a multiparameter analysis

Purpose: This paper describes a method to achieve consistent clinical image quality in {sup 18}F-FDG scans accounting for patient habitus, dose regimen, image acquisition, and processing techniques. Methods: Oncological PET/CT scan data for 58 subjects were evaluated retrospectively to derive analytical curves that predict image quality. Patient noise equivalent count rate and coefficient of variation (CV) were used as metrics in their analysis. Optimized acquisition protocols were identified and prospectively applied to 179 subjects. Results: The adoption of different schemes for three body mass ranges (<60 kg, 60–90 kg, >90 kg) allows improved image quality with both point spread function and ordered-subsets expectation maximization-3D reconstruction methods. The application of this methodology showed that CV improved significantly (p < 0.0001) in clinical practice. Conclusions: Consistent oncological PET/CT image quality on a high-performance scanner was achieved from an analysis of the relations existing between dose regimen, patient habitus, acquisition, and processing techniques. The proposed methodology may be used by PET/CT centers to develop protocols to standardize PET/CT imaging procedures and achieve better patient management and cost-effective operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Demonstration of SuperLig{sup R} 605 and SuperLig{sup R} 644 in a Regeneration Flow Sheet to Remove Radioactive Strontium and Cesium from Seawater - 16236

Remediation techniques are needed for efficient removal of radioactive strontium and cesium from seawater. Molecular Recognition Technology, using selective SuperLig{sup R} resins, demonstrates a clean chemistry approach to solving this problem. Molecular Recognition Technology offers high levels of separation of chemically pure metal contaminants, whose subsequent disposal is compatible with simple waste forms (grout and glass). SuperLig{sup R} resins can be regenerated with common reagents and used many times, limited by a dose of 1 E+9 Rad, which assures low volumes of secondary solid waste. The metal selectivity of the SuperLig{sup R} resin ensures that the solid waste is of low residual activity. These properties of sustainability are illustrated in a project that demonstrated the ability of two SuperLig{sup R} resins to selectively remove Cs and Sr from a seawater mimic representative of the contaminated seawater in Fukushima, Dai'ichi, Japan harbor. Removal of radioactive Sr-90 and Cs-134/Cs-137 from seawater using conventional ion exchange or a complexing agent is complicated by the presence of large excesses of competing ions such as Na, K, Ca, and Mg, which can be co-extracted. These competing ions, if co-extracted, reduce the capacity of a single pass resin with the consequent increase in volume of spent resin or decrease in capacity of a regenerable resin. The successful demonstration reported in this study has shown the ability of two proprietary resins, SuperLig{sup R} 605 and SuperLig{sup R} 644, to remove Sr and Cs, respectively, with high selectivity from simulated solutions containing these metal ions together with major constituents of seawater at their normal concentrations. This effort was part of a demonstration project to investigate methods for removal of Sr-90 and Cs-134/Cs-137 from 160,000 cubic meters of seawater impounded at Fukushima, Dai'ichi, Japan harbor. SuperLig{sup R} resins can be regenerated by elution with small volumes of simple acid solutions. SuperLig{sup R} resins have a high tolerance to radiation, with their performance not being degraded by doses of 1.0 E+9 Rad. Estimates, based on the results obtained, are that Cs and Sr levels in the volume of seawater in the Fukushima, Dai'ichi, Japan harbor could be reduced to desired discharge limits in 200 days with some 30 cubic meters of the two SuperLig{sup R} resins and that decontamination factors of 10 or more could be achieved. Results of the demonstration, together with advantages of the Molecular Recognition Technology process over conventional procedures for these separations are presented and discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation Dose Reduction in CT Fluoroscopy-Guided Cervical Transforaminal Epidural Steroid Injection by Modifying Scout and Planning Steps

Background and PurposeIn CT fluoroscopy (CTF)-guided cervical transforaminal epidural steroid injection (TFESI), the majority of radiation dose is contributed by the planning CT scan rather than the CTF procedure itself. We replaced the planning helical CT with a spot CTF and accordingly changed the patient posture during scout and planning scans. The aim of this study was to test whether radiation dose reduction would be achieved by this protocol modification while still maintaining technical performance.MethodsOverall, 338 consecutive procedures before (control group: n = 163) and after (study group: n = 175) instituting the above-mentioned protocol modification were analyzed retrospectively, comparing patient characteristics (age, sex, neck diameter, and level injected) and technical performance [technical success rate, dose-length product (DLP), inadvertent contrast flow incidence, number of CTF acquisitions, and procedural time] between the two groups.ResultsAll injections were technically successful at every level from C3–C4 to C7–T1 without serious complications in both groups. The median DLP of the study group (7.92 mGy·cm) was significantly reduced compared to that of the control group (39.05 mGy·cm, P < 0.001). There were no significant differences between the two groups regarding the incidence of inadvertent contrast flow (20.6 vs. 17.2 %, P = 0.426), number of CTF acquisitions (median 5 vs. 4, P = 0.123), and the procedural time (median 6.62 vs. 6.90 min, P = 0.100).ConclusionsWhen conducting CTF-guided cervical TFESIs, a significant radiation dose reduction (median 79.7 % in DLP) can be achieved by modifying scout and planning steps, without compromising the technical performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fusion Imaging and Virtual Navigation to Guide Percutaneous Thermal Ablation of Hepatocellular Carcinoma: A Review of the Literature

As medical imaging advancements have improved the detectability of hepatocellular carcinoma (HCC) in early stages, the approach to percutaneous thermal ablation for curative treatment has concomitantly advanced. Although many centers are adopting cross-sectional imaging to guide percutaneous ablation, the majority of procedures are still performed under ultrasound (US) guidance worldwide. Challenges to ultrasound guidance may present due to relatively poor resolution particularly with small or isoechoic lesions, or due to intervening structures such as the bowel or diaphragm that obstruct lesional visualization. Fusion imaging (FI) systems have been employed to address these challenges. By merging or synchronizing the real-time images from US with a previously obtained cross-sectional study, FI mitigates the inherent limitations of each individual imaging modality and expands procedural feasibility and technical outcomes. This manuscript reviews the current literature on the use of FI during percutaneous thermal ablation of HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ACC/AATS/AHA/ASE/ASNC/HRS/SCAI/SCCT/SCMR/STS 2019 Appropriate Use Criteria for Multimodality Imaging in the Assessment of Cardiac Structure and Function in Nonvalvular Heart Disease

This document is the second of 2 companion appropriate use criteria (AUC) documents developed by the American College of Cardiology, American Association for Thoracic Surgery, American Heart Association, American Society of Echocardiography, American Society of Nuclear Cardiology, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, and Society of Thoracic Surgeons. The first document (J Am Coll Cardiol 2017;70:1647-1672) addresses the evaluation and use of multimodality imaging in the diagnosis and management of valvular heart disease, whereas this document addresses this topic with regard to structural (nonvalvular) heart disease. While dealing with different subjects, the 2 documents do share a common structure and feature some clinical overlap. The goal of the companion AUC documents is to provide a comprehensive resource for multimodality imaging in the context of structural and valvular heart disease, encompassing multiple imaging modalities. Using standardized methodology, the clinical scenarios (indications) were developed by a diverse writing group to represent patient presentations encountered in everyday practice and included common applications and anticipated uses. Where appropriate, the scenarios were developed on the basis of the most current American College of Cardiology/American Heart Association Clinical Practice Guidelines. A separate, independent rating panel scored the 102 clinical scenarios in this document on a scale of 1 to 9. Scores of 7 to 9 indicate that a modality is considered appropriate for the clinical scenario presented. Midrange scores of 4 to 6 indicate that a modality may be appropriate for the clinical scenario, and scores of 1 to 3 indicate that a modality is considered rarely appropriate for the clinical scenario. The primary objective of the AUC is to provide a framework for the assessment of these scenarios by practices that will improve and standardize physician decision making. AUC publications reflect an ongoing effort by the American College of Cardiology to critically and systematically create, review, and categorize clinical situations in which diagnostic tests and procedures are utilized by physicians caring for patients with cardiovascular diseases. The process is based on the current understanding of the technical capabilities of the imaging modalities examined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

BAM challenges for design testing of waste containers for the final repository KONRAD

Up to the end of this decade, corresponding to the planned date of starting operation in the final disposal KONRAD for non-heat generating waste in Germany, a lot of efforts are needed to condition and package the radioactive waste in containers certified by BfS (Federal Institute for Radiation Protection). This waste is produced by public sector and industry as well as nuclear energy facilities, which result in more than a half of the actually declared quantity growing especially after the phase out decision of nuclear power production in Germany and the subsequent decommissioning of nuclear power plants. BAM (Federal Institute for Materials Research and Testing) acts as responsible authority on behalf of BfS for design testing under consideration of the KONRAD requirements. Within the assessment procedure of containers, BAM has to verify the application documents, including material qualification, container geometry, corrosion protection, leakage rate and operational and accidental loading, and to evaluate quality assurance measures. Besides the previous completed approvals for various containers such as steel sheet and cast iron box-shaped containers and concrete cylindrical ones, BAM is actually carrying assessments for other types such as cast iron cylindrical containers and 'old' steel sheet box shaped ones. The so called 'old' containers present already loaded containers without any KONRAD certification, currently stored at licensed interim storages. In the benefit of the container assessment, BAM operates design testing facilities for drop and fire tests which are also used for research objectives to improve and expand the evaluation methods such as research project ConDrop. The latter deals with numerical simulations and analyses tools for further precise predictions about unfavorable drop test scenarios, safety margins, and design sensitivities for steel sheet containers. Furthermore, during the assessment procedure, several specifications about the containers, the inventory to be disposed and the required safety level have been intensely debated by authorities and applicants. Based on its experience in qualifying containers, BAM has been commissioned to identify insufficiently specified aspects in the waste acceptance criteria and to propose clearer definitions with regard to the secondary regulations in the planning approval notice. This paper focuses on aspects of the contribution of BAM in certifying KONRAD waste containers. This will include the current state of design testing procedures, evaluation methods that are available or are being developed and the main topics within the KONRAD requirements being actually specified by BAM. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TU-F-201-00: Radiochromic Film Dosimetry Update

Since the introduction of radiochromic films (RCF) for radiation dosimetry, the scope of RCF dosimetry has expanded steadily to include many medical applications, such as radiation therapy and diagnostic radiology. The AAPM Task Group (TG) 55 published a report on the recommendations for RCF dosimetry in 1998. As the technology is advancing rapidly, and its routine clinical use is expanding, TG 235 has been formed to provide an update to TG-55 on radiochromic film dosimetry. RCF dosimetry applications in clinical radiotherapy have become even more widespread, expanding from primarily brachytherapy and radiosurgery applications, and gravitating towards (but not limited to) external beam therapy (photon, electron and protons), such as quality assurance for IMRT, VMAT, Tomotherapy, SRS/SRT, and SBRT. In addition, RCF applications now extend to measurements of radiation dose in particle beams and patients undergoing medical exams, especially fluoroscopically guided interventional procedures and CT. The densitometers/scanners used for RCF dosimetry have also evolved from the He-Ne laser scanner to CCD-based scanners, including roller-based scanner, light box-based digital camera, and flatbed color scanner. More recently, multichannel RCF dosimetry introduced a new paradigm for external beam dose QA for its high accuracy and efficiency. This course covers in detail the recent advancements in RCF dosimetry. Learning Objectives: Introduce the paradigm shift on multichannel film dosimetry Outline the procedures to achieve accurate dosimetry with a RCF dosimetry system Provide comprehensive guidelines on RCF dosimetry for various clinical applications One of the speakers has a research agreement from Ashland Inc., the manufacturer of Gafchromic film.

60 APPLIED LIFE SCIENCES↗

Molten Salt Oxidation of Ion Exchange and Oils in Carbonate Salts and Evaporator Residue - 16531

Molten Salt Oxidation is a well-studied and robust technology. Recently, renewed interest in the technology has been seen due to limitations on the use of incineration for hazardous and radioactive waste streams. The nuclear research center at Rez, near Prague, has been investigating a bench scale molten salt oxidation system to provide insight for the design of a pilot scale system to condition spent ion exchange resin and scintillator oils. The use of both an eutectic K/Na/Li carbonate salt and a simulated residue salt for liquid waste obtained from evaporated primary coolant of nuclear reactors was examined. In these studies the usable capacity of the salts were examined. Materials doped with surrogate radioisotopes were processed and the capture efficiency was measured. Corrosion of the reactor vessel is of significant engineering concern. Corrosion coupon tests were performed for Inconel HX and stainless steel. These tests provided corrosion rates to assist in design of pilot scale systems. While the bench scale reactor's detention time was too short to provide complete combustion, the values of emissions were tracked and showed an increase in the combustion efficiency at temperatures greater than 750 deg. C. A two part reactor has been designed and work is planned to continue to optimize the system. Additionally, further work has examined the final conditioning of salt which has been saturated with radionuclides after processing organic waste streams A conceptual pilot plant has been designed to solidify radionuclide saturated salt into a form acceptable for repositories according to EU directives. Saturated salt is milled to a powder and immobilized in a matrix with a high percentage of waste loading. Both geo-polymer and polysiloxane matrices have been methods for low temperature immobilization. Conditioning in this manner decreases operating and capital costs when compared to current conditioning technologies and procedures utilized for high volume reduction factors of final waste forms. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flat-Panel Cone-Beam Ct-Guided Radiofrequency Ablation of Very Small (≤1.5 cm) Liver Tumors: Technical Note on a Preliminary Experience

PurposeThe aim of the present study was to investigate the technical feasibility of flat-panel cone-beam CT (CBCT)-guided radiofrequency ablation (RFA) of very small (<1.5 cm) liver tumors.Materials and MethodsPatients included were candidates for hepatic percutaneous RFA as they had single biopsy-proven hepatic tumors sized ≤1.5 cm and poorly defined on ultrasonography. Following apnea induction, unenhanced CBCT scans were acquired and used to deploy the RF electrode with the aid of a virtual navigation system. If the tumor was not clearly identified on the unenhanced CBCT scan, a right retrograde arterial femoral access was established to carry out hepatic angiography and localize the tumor. Patients’ lesions and procedural variables were recorded and analyzed.ResultsThree patients (2 male and 1 female), aged 68, 76, and 87 years were included; 3 lesions (2 hepato-cellular carcinoma and 1 metastasis from colorectal cancer) were treated. One patient required hepatic angiography. Cycles of apnea used to acquire CBCT images and to deploy the electrode lasted <120 s. Mean fluoroscopic time needed to deploy the electrode was 36.6 ± 5.7 min. Mean overall procedural time was 66.0 ± 22.9 min. No peri- or post-procedural complications were noted. No cases of incomplete ablation were noted at 1-month follow-up.ConclusionPercutaneous CBCT-guided liver RFA with or without arterial hepatic angiography is technically feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calibration of time-of-flight cameras for accurate intraoperative surface reconstruction

Purpose: In image-guided surgery (IGS) intraoperative image acquisition of tissue shape, motion, and morphology is one of the main challenges. Recently, time-of-flight (ToF) cameras have emerged as a new means for fast range image acquisition that can be used for multimodal registration of the patient anatomy during surgery. The major drawbacks of ToF cameras are systematic errors in the image acquisition technique that compromise the quality of the measured range images. In this paper, we propose a calibration concept that, for the first time, accounts for all known systematic errors affecting the quality of ToF range images. Laboratory and in vitro experiments assess its performance in the context of IGS.Methods: For calibration the camera-related error sources depending on the sensor, the sensor temperature and the set integration time are corrected first, followed by the scene-specific errors, which are modeled as function of the measured distance, the amplitude and the radial distance to the principal point of the camera. Accounting for the high accuracy demands in IGS, we use a custom-made calibration device to provide reference distance data, the cameras are calibrated too. To evaluate the mitigation of the error, the remaining residual error after ToF depth calibration was compared with that arising from using the manufacturer routines for several state-of-the-art ToF cameras. The accuracy of reconstructed ToF surfaces was investigated after multimodal registration with computed tomography (CT) data of liver models by assessment of the target registration error (TRE) of markers introduced in the livers.Results: For the inspected distance range of up to 2 m, our calibration approach yielded a mean residual error to reference data ranging from 1.5 ± 4.3 mm for the best camera to 7.2 ± 11.0 mm. When compared to the data obtained from the manufacturer routines, the residual error was reduced by at least 78% from worst calibration result to most accurate manufacturer data. After registration of the CT data with the ToF data, the mean TRE ranged from 3.7 ± 2.1 mm for point-based and 5.7 ± 1.9 mm for surface-based registration for the best camera to 6.2 ± 3.4 and 11.1 ± 2.8 mm, respectively. Compared to data provided by the manufacturer, the mean TRE decreased by 8%–60% for point-based and by 18%–74% for surface-based registration.Conclusions: Using the proposed calibration approach improved the measurement accuracy of all investigated ToF cameras. Although evaluated in the context of intraoperative image acquisition, the proposed calibration procedure can easily be applied to other medical applications using ToF cameras, such as patient positioning or respiratory motion tracking in radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗