Search NASA⌕ Search

SEARCH · Search NASA

Results for “conductive liquid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Study of Heat Transfer and Flow Characteristics of Rising Taylor Bubbles

Practical application of flow boiling to ground- and space-based thermal management systems hinges on the ability to predict the systems heat removal capabilities under expected operating conditions. Research in this field has shown that the heat transfer coefficient within two-phase heat exchangers can be largely dependent on the experienced flow regime. This finding has inspired an effort to develop mechanistic heat transfer models for each flow pattern which are likely to outperform traditional empirical correlations. As a contribution to the effort, this work aimed to identify the heat transfer mechanisms for the slug flow regime through analysis of individual Taylor bubbles.An experimental apparatus was developed to inject single vapor Taylor bubbles into co-currently flowing liquid HFE 7100. The heat transfer was measured as the bubble rose through a 6 mm inner diameter heated tube using an infrared thermography technique. High-speed flow visualization was obtained and the bubble film thickness measured in an adiabatic section. Experiments were conducted at various liquid mass fluxes (43-200 kgm2s) and gravity levels (0.01g-1.8g) to characterize the effect of bubble drift velocityon the heat transfer mechanisms. Variable gravity testing was conducted during a NASA parabolic flight campaign.Results from the experiments showed that the drift velocity strongly affects the hydrodynamics and heat transfer of single elongated bubbles. At low gravity levels, bubbles exhibited shapes characteristic of capillary flows and the heat transfer enhancement due to the bubble was dominated by conduction through the thin film. At moderate to high gravity, traditional Taylor bubbles provided small values of enhancement within the film, but large peaks in the wake heat transfer occurred due to turbulent vortices induced by the film plunging into the trailing liquid slug. Characteristics of the wake heat transfer profiles were analyzed and related to the predicted velocity field. Results were compared and shown to agree with numerical simulations of colleagues from EPFL, Switzerland.In addition, a preliminary study was completed on the effect of a Taylor bubble passing through nucleate flow boiling, showing that the thinning thermal boundary layer within the film suppressed nucleation, thereby decreasing the heat transfer coefficient.

capillary flow↗

Metallized gelled propellants: Oxygen/RP-1/aluminum combustion experiments

A series of combustion experiments using metallized gelled liquid propellants were conducted. These experiments used a small 30- to 40-lb(sub f) thrust engine composed of a modular injector, igniter, chamber and nozzle. The fuels used were traditional liquid RP-1 and gelled RP-1 with 0-wt percent, 5-wt percent, and 44-wt percent loadings of aluminum and gaseous oxygen and the oxidizer. Ten different injectors were used during the testing: 6 were for the baseline O2/RP-1 tests and 4 for the gelled fuels. Relatively high C-star efficiencies were obtained with gelled RP-1 (0-wt% RP-1/Al) and metallized 5-wt% RP-1/Al over the O/F range tested: 90-98%. A peak of 98 percent efficiency was reached with ungelled O2/RP-1 and up to 95% efficiency was obtained with gelled RP-1/Al (55-wt% Al). Injector erosion was evident with the 55-wt% testing, while there was little or no erosion seen with the gelled RP-1 with 0 and 5-wt% Al. A protective layer of gelled fuel formed in the firings that minimized the damage to the rocket injector face. This effect may provide a useful technique for engine cooling.

Palaszewski, Bryan↗

Critical levitation loci for spheres on cryogenic fluids.

The conditions which allow a fluid to support a sphere having a higher specific gravity than its own are investigated. Three basic parameters which together define the maximum floating conditions are considered, including the Bond number, the wetting angle of the interface, and the ratio of solid-liquid specific gravities. The Bond number represents the ratio of buoyancy to surface tension forces. An analysis of the forces at the sphere-liquid interface is conducted to determine the optimum levitation loci, that is, the conditions permitting flotation of a maximum density sphere. Data for glycerine, carbon tetrachloride, and water spheres floating on a liquid nitrogen surface appear to be in good agreement with the analysis. Data for Teflon spheres on water also appear to be in agreement with the analytical results.

Hendricks, R. C.↗

Heat-transfer tests of aqueous ethylene glycol solutions in an electrically heated tube

As part of an investigation of the cooling characteristics of liquid-cooled engines, tests were conducted with an electrically heated single-tube heat exchanger to determine the heat-transfer characteristics of an-e-2 ethylene glycol and other ethylene glycol-water mixtures. Similar tests were conducted with water and commercial butanol (n-butyl alcohol) for check purposes. The results of tests conducted at an approximately constant liquid-flow rate of 0.67 pound per second (Reynolds number, 14,500 to 112,500) indicate that at an average liquid temperature 200 degrees f, the heat-transfer coefficients obtained using water, nominal (by volume) 30 percent-70 percent and 70 percent-30 percent glycol-water mixtures are approximately 3.8, 2.8, and 1.4 times higher, respectively, than the heat-transfer coefficients obtained using an-e-2 ethylene glycol.

Bernardo, Everett↗

Containerless Liquid-Phase Processing of Ceramic Materials

The present project builds on the results of research supported under a previous NASA grant to investigate containerless liquid-phase processing of molten ceramic materials. The research used an aero-acoustic levitator in combination with cw CO2 laser beam heating to achieve containerless melting, superheating, undercooling, and solidification of poorly-conducting solids and liquids. Experiments were performed on aluminum oxide, binary aluminum oxide-silicon dioxide materials, and oxide superconductors.

Weber, J. K. Richard↗

Experimental Effervescence and Freezing Point Depression Measurements of Nitrogen in Liquid Methane-Ethane Mixtures

NASA is designing an unmanned submarine to explore the depths of the hydrocarbon-rich seas on Saturn's moon Titan. Data from Cassini indicates that the Titan north polar environment sustains stable seas of variable concentrations of ethane, methane, and nitrogen, with a surface temperature near 93 K. The submarine must operate autonomously, study atmosphere/sea exchange, interact with the seabed, hover at the surface or any depth within the sea, and be capable of tolerating variable hydrocarbon compositions. Currently, the main thermal design concern is the effect of effervescence on submarine operation, which affects the ballast system, science instruments, and propellers. Twelve effervescence measurements on various liquid methane-ethane compositions with dissolved gaseous nitrogen are thus presented from 1.5 bar to 4.5 bar at temperatures from 92 K to 96 K to simulate the conditions of the seas. After conducting effervescence measurements, two freezing point depression measurements were conducted. The freezing liquid line was depressed more than 15 K below the triple point temperatures of pure ethane (90.4 K) and pure methane (90.7 K). Experimental effervescence measurements will be used to compare directly with effervescence modeling to determine if changes are required in the design of the thermal management system as well as the propellers.

Submarine↗

Metallized Gelled Propellant Heat Transfer Tests Analyzed

A series of rocket engine heat transfer experiments using metallized gelled liquid propellants was conducted at the NASA Lewis Research Center. These experiments used a small 20- to 40-lbf thrust engine composed of a modular injector, an igniter, a chamber, and a nozzle. The fuels used were traditional liquid RP-1 and gelled RP-1 with 0-, 5-, and 55-wt % loadings of aluminum particles. Gaseous oxygen was used as the oxidizer. Heat transfer measurements were made with a rocket engine calorimeter chamber and nozzle with a total of 31 cooling channels. Each channel used water flow to carry heat away from the chamber and the attached thermocouples; flow meters allowed heat flux estimates at each of the 31 stations.

Palaszewski, Bryan A.↗

Agreement between experimental and theoretical effects of nitrogen gas flowrate on liquid jet atomization

Two-phase flows were investigated by using high velocity nitrogen gas streams to atomize small-diameter liquid jets. Tests were conducted primarily in the acceleration-wave regime for liquid jet atomization, where it was found that the loss of droplets due to vaporization had a marked effect on drop size measurements. In addition, four identically designed two-fluid atomizers were fabricated and tested for similarity of spray profiles. A scattered-light scanner was used to measure a characteristic drop diameter, which was correlated with nitrogen gas flowrate. The exponent of 1.33 for nitrogen gas flowrate is identical to that predicted by atomization theory for liquid jet breakup in the acceleration-wave regime. This is higher than the value of 1.2 which was previously obtained at a sampling distance of 4.4 cm downstream of the atomizer. The difference is attributed to the fact that drop-size measurements obtained at a 2.2 cm sampling distance are less effected by vaporization and dispersion of small droplets and therefore should give better agreement with atomization theory. Profiles of characteristic drop diameters were also obtained by making at least five line-of-sight measurements across the spray at several horizontal positions above and below the center line of the spray.

Ingebo, Robert D.↗

Agreement between experimental and theoretical effects of nitrogen gas flowrate on liquid jet atomization

Two-phase flows were investigated by using high velocity nitrogen gas streams to atomize small-diameter liquid jets. Tests were conducted primarily in the acceleration-wave regime for liquid jet atomization, where it was found that the loss of droplets due to vaporization had a marked effect on drop-size measurements. In addition, four identically designed two-fluid atomizers were fabricated and tested for similarity of spray profiles. A scattered-light scanner was used to measure a characteristic drop diameter, which was correlated with nitrogen gas flowrate. The exponent of 1.33 for nitrogen gas flowrate is identical to that predicted by atomization theory for liquid jet breakup in the acceleration-wave regime. This is higher than the value of 1.2 which was previously obtained at a smapling distance of 4.4 cm downstream of the atomizer. The difference is attributed to the fact that drop-size measurements obtained at a 2.2 cm sampling distance are less affected by vaporization and dispersion of small droplets and therefore should give better agreement with atomization theory. Profiles of characteristic drop diameters were also obtained by making at least five line-of-sight measurements across the spray at several horizontal positions above and below the center line of the spray.

Ingebo, Robert D.↗

Fabrication and Testing of Low Cost 2D Carbon-Carbon Nozzle Extensions at NASA/MSFC

Subscale liquid engine tests were conducted at NASA/MSFC using a 1.2 Klbf engine with liquid oxygen (LOX) and gaseous hydrogen. Testing was performed for main-stage durations ranging from 10 to 160 seconds at a chamber pressure of 550 psia and a mixture ratio of 5.7. Operating the engine in this manner demonstrated a new and affordable test capability for evaluating subscale nozzles by exposing them to long duration tests. A series of 2D C-C nozzle extensions were manufactured, oxidation protection applied and then tested on a liquid engine test facility at NASA/MSFC. The C-C nozzle extensions had oxidation protection applied using three very distinct methods with a wide range of costs and process times: SiC via Polymer Impregnation & Pyrolysis (PIP), Air Plasma Spray (APS) and Melt Infiltration. The tested extensions were about 6" long with an exit plane ID of about 6.6". The test results, material properties and performance of the 2D C-C extensions and attachment features will be discussed.

Greene, Sandra Elam↗

Results of the Fluid Merging Viscosity Measurement International Space Station Experiment

The purpose of FMVM is to measure the rate of coalescence of two highly viscous liquid drops and correlate the results with the liquid viscosity and surface tension. The experiment takes advantage of the low gravitational free floating conditions in space to permit the unconstrained coalescence of two nearly spherical drops. The merging of the drops is accomplished by deploying them from a syringe and suspending them on Nomex threads followed by the astronaut s manipulation of one of the drops toward a stationary droplet till contact is achieved. Coalescence and merging occurs due to shape relaxation and reduction of surface energy, being resisted by the viscous drag within the liquid. Experiments were conducted onboard the International Space Station in July of 2004 and subsequently in May of 2005. The coalescence was recorded on video and down-linked near real-time. When the coefficient of surface tension for the liquid is known, the increase in contact radius can be used to determine the coefficient of viscosity for that liquid. The viscosity is determined by fitting the experimental speed to theoretically calculated contact radius speed for the same experimental parameters. Recent fluid dynamical numerical simulations of the coalescence process will be presented. The results are important for a better understanding of the coalescence process. The experiment is also relevant to liquid phase sintering, free form in-situ fabrication, and as a potential new method for measuring the viscosity of viscous glass formers at low shear rates.

Ethridge, Edwin C.↗

A New Antiwear Additive/Surface Pretreatment for PFPE Liquid Lubricants

Pin-on-disk tribology experiments were conducted on a perfluoroalkylelher (PFPE) liquid lubricant with and without a new PFPE lubricant antiwear additive material, a silane. It was found that the silane provided moderate improvement in the antiwear performance of the PFPE lubricant when applied to the metallic surface as a surface coating or when added to the PFPE as a dispersion (emulsion). Slightly better results were obtained by using the combination of a surface coating and an emulsion of the silane. The silane emulsions or coatings did not affect the friction properties of the lubricant. Micro-Fourier transformation infrared (muFTIR) spectroscopy analysis was performed to study silane transfer films and the degradation of the PFPE. The silane was found to mitigate degradation of the PFPE which may have been the major reason for the improved antiwear performance observed.

Morales, Wilfredo↗

Developing a Hybrid Space Suit Simulator as a Research Tool for Assessing Extravehicular Activity Relevant Workload

Suited testing time is limited and hard to come by, expensive, and requires a whole team to operate and monitor the suit; however, pressurized spacesuits are not always necessary for initial developmental efforts or assessment of informatics. The Human Physiology, Performance, Protection & Operations Laboratory (H-3PO) at NASA Johnson Space Center (JSC) is developing a Hybrid Space Suit Simulator (HS3) to support characterization of human performance during planetary surface exploration analogs. The primary goal of HS3 is to create a low cost, modular, and unpressurized suit simulator for use as a research tool which provides relevant physical and cognitive workload approximations with EVA-like immersion during planetary extravehicular activity (EVA) simulations. HS3 consists of a soft suit, communication, thermal control, gloves, boots, helmet, and integrated bioinformatics/sensors. The modular design of HS3 allows it to be modified to support test objectives as needed. HS3 enables H-3PO and NASA to complete critical human health and performance testing to address open risks and knowledge gaps in a timely, repeatable, and controlled manner. Four engineering runs were completed with HS3 as a baseline for capability. General workload was assessed while traversing on a passive treadmill and conducting geology tasks. Liquid cooling temperature, suit temperature, and metabolic rates were collected during one extended three-hour engineering run. For the duration of the engineering run the suit temperature was 26.6 ± 1.58 °C while suit humidity was 53.7 ± 5.11 %. Helmet temperature was higher than suit temperature at 27.8 ± 1.58 °C. Helmet humidity was lower than average suit humidity at 50.12 ± 11.3 °C. The liquid cooling temperature remained stable at 22.4 ± 1.62 °C. Resting metabolic rate was 597 ± 88 BTU/hr while metabolic rate increased during traverse tasks at 1500 ± 319 BTU/hr and geology tasks at 921 ± 129 BTU/hr. Following the engineering runs, a characterization study will be conducted. The subjects will perform EVA-like scenarios in both a shirtsleeve only and donned HS3, consisting of EVA task circuit focused on traversing, geological rock sampling, and task board manipulation. The characterization study will provide data capability for implementing HS3 in analog EVA testing environments.

Monica Hew↗

A (He-3)-gap heat switch for use below 2 K in zero g

We have designed and tested a compact heat switch that has a simple design and a very large ON/OFF ratio. The design uses concentric cylinders of copper that can be fabricated with higher precision and with thinner web thickness than other designs. It is assembled with a technique that carefully controls the narrow gap between adjacent segments. These features allow a very large surface area for conduction to be fitted into a small volume. The conduction medium is liquid or gaseous He-3, which is put into or taken out of the switch by a small nearby charcoal pump in order to avoid an external mechanical pump and a long pump line. Measurements of its performance down to 1 K show an ON/OFF conduction ratio of about 4000.

Roach, Pat R.↗

A He-3-gap heat switch for use below 2 K in zero G

We have designed and tested a compact heat switch that has a simple design and a very large ON/OFF ratio. The design uses concentric cylinders of copper that can be fabricated with higher precision and with thinner web thickness than other designs. It is assembled with a technique that carefully controls the narrow gap between adjacent segments. These features allow a very large surface area for conduction to be fitted into a small volume. The conduction medium is liquid or gaseous He-3 which is put into or taken out of the switch by a small nearby charcoal pump in order to avoid an external mechanical pump and a long pump line. Measurements of its performance down to 1 K show an ON/OFF conduction ratio of about 4000.

Roach, Pat R.↗

Flow Visualization of Low Prandtl Number Fluids using Electrochemical Measurements

It is well established that residual flows exist in contained liquid metal processes. In 1-g processing, buoyancy forces often drive these flows and their magnitudes can be substantial. It is also known that residual flows can exist during microgravity processing, and although greatly reduced in magnitude, they can influence the properties of the processed materials. Unfortunately, there are very few techniques to visualize flows in opaque, high temperature liquid metals, and those available are not easily adapted to flight investigation. In this study, a novel technique is developed that uses liquid tin as the model fluid and solid-state electrochemical cells constructed from Yttria-Stabilized Zirconia (YSZ) to establish and measure dissolved oxygen boundary conditions. The melt serves as a common electrode for each of the electrochemical cells in this design, while independent reference electrodes are maintained at the outside surfaces of the electrolyte. By constructing isolated electrochemical cells at various locations along the container walls, oxygen is introduced or extracted by imposing a known electrical potential or passing a given current between the melt and the reference electrode. This programmed titration then establishes a known oxygen concentration boundary condition at the selected electrolyte-melt interface. Using the other cells, the concentration of oxygen at the electrolyte-melt interface is also monitored by measuring the open-circuit potentials developed between the melt and reference electrodes. Thus the electrochemical cells serve to both establish boundary conditions for the passive tracer and sense its path. Rayleigh-Benard convection was used to validate the electrochemical approach to flow visualization. Thus, a numerical characterization of the second critical Rayleigh numbers in liquid tin was conducted for a variety of Cartesian aspect ratios. The extremely low Prandtl number of tin represents the lowest value studied numerically. Additionally, flow field oscillations are visualized and the effect of tilt on convecting systems is quantified. Experimental studies of the effect of convection in liquid tin are presented. Three geometries are studied: (1) double electrochemical cell with vertical concentration gradients; (2) double cell with horizontal concentration gradients; and (3) multiple cells with vertical temperature gradients. The first critical Rayleigh number transition is detected with geometry (1) and it is concluded that current measurements are not as affected by convection as EMF measurements. The system is compared with numerical simulations in geometry (2), and oscillating convection is detected with geometry (3).

Crunkleton, D.↗

Use of Ionic Liquids in Rod-Coil Block Copolyimides for Improved Lithium Ion Conduction

Solvent-free, solid polymer electrolytes (SPE) have the potential to improve safety, increase design flexibility and enhance performance of rechargeable lithium batteries. Solution based electrolytes are flammable and typically incompatible with lithium metal anodes, limiting energy density. We have previously demonstrated use of polyimide rod coil block copolymers doped with lithium salts as electrolytes for lithium polymer batteries. The polyimide rod blocks provide dimensional stability while the polyethylene oxide (PEO) coil portions conduct ions. Phase separation of the rods and coils in these highly branched polymers provide channels with an order of magnitude improvement in lithium conduction over polyethylene oxide itself at room temperature. In addition, the polymers have been demonstrated in coin cells to be compatible with lithium metal. For practical use at room temperature and below, however, at least an order of magnitude improvement in ion conduction is still required. The addition of nonvolatile, room temperature ionic liquids has been shown to improve the ionic conductivity of high molecular weight PEO. Herein we describe use of these molten salts to improve ionic conductivity in the rod-coil block copolymers.

Meador, Mary Ann B.↗

Time and Space Resolved Heat Flux Measurements During Nucleate Boiling with Constant Heat Flux Boundary Conditions

The lack of temporally and spatially resolved measurements under nucleate bubbles has complicated efforts to fully explain pool-boiling phenomena. The objective of this current work was to acquire time and space resolved temperature distributions under nucleating bubbles on a constant heat flux surface using a microheater array with 100x 100 square microns resolution, then numerically determine the wall to liquid heat flux. This data was then correlated with high speed (greater than l000Hz) visual recordings of The bubble growth and departure from the heater surface acquired from below and from the side of the heater. The data indicate that microlayer evaporation and contact line heat transfer are not major heat transfer mechanisms for bubble growth. The dominant heat transfer mechanism appears to be transient conduction into the liquid as the liquid rewets the wall during the bubble departure process.

Yerramilli, Vamsee K.↗