Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

A Comparison of Classical and Aggregation-Based Algebraic Multigrid Preconditioners for High-Fidelity Simulation of Wind Turbine Incompressible Flows

This paper presents a comparison of parallel strong scaling performance of classical and aggregation algebraic multigrid (AMG) preconditioners in the context of wind turbine simulations. Fluid motion is governed by the incompressible Navier--Stokes equations, discretized in space with control-volume finite elements and in time with an inexact projection scheme using an implicit integrator. A discontinuous-Galerkin sliding-mesh algorithm captures rotor motion. The momentum equations are solved with iterative Krylov methods, preconditioned by symmetric Gauss--Seidel (SGS) in Trilinos and $\ell_1$ SGS in hypre. The mass-continuity equation is solved with GMRES preconditioned by AMG and can account for the majority of simulation time. Reducing this continuity solve time is crucial. Wind turbine simulations present two unique challenges for AMG preconditioned solvers: the computational meshes include strongly anisotropic elements, and mesh motion requires matrix reinitialization and computation of preconditioners at each time step. Detailed timing profiles are presented and analyzed, and best practices are discussed for both classical and aggregation-based AMG. Results are presented for simulations of two different wind turbines with up to 6 billion grid points on two different computer architectures. For moving mesh problems that require linear-system reinitialization, the well-established strategy of amortizing preconditioner setup costs over a large number of time steps to reduce the solve time is no longer valid. Instead, results show that faster time to solution is achieved by reducing preconditioner setup costs at the expense of linear-system solve costs. Standard smoothed aggregation with Chebyshev relaxation was found to perform poorly when compared with classical AMG in terms of solve time and robustness. However, plain aggregation was comparable to classical AMG.

97 MATHEMATICS AND COMPUTING↗

Chemical Upcycling of Polyethylene, Polypropylene, and Mixtures to High-Value Surfactants

Conversion of plastic wastes to fatty acids is an attractive means to supplement the sourcing of these high-value, high-volume chemicals. We report a method for transforming polyethylene (PE) and polypropylene (PP) at ~80% conversion to fatty acids with number-average molar masses of up to ~700 and 670 daltons, respectively. The process is applicable to municipal PE and PP wastes and their mixtures. Temperature-gradient thermolysis is the key to controllably degrading PE and PP into waxes and inhibiting the production of small molecules. The waxes are upcycled to fatty acids by oxidation over manganese stearate and subsequent processing. PP ..beta..-scission produces more olefin wax and yields higher acid-number fatty acids than does PE ..beta..-scission. We further convert the fatty acids to high-value, large-market-volume surfactants. Industrial-scale technoeconomic analysis suggests economic viability without the need for subsidies.

deconstruction↗

Increasing Tumor Volume is Predictive of Poor Overall and Progression-Free Survival: Secondary Analysis of the Radiation Therapy Oncology Group 93-11 Phase I-II Radiation Dose-Escalation Study in Patients with Inoperable Non-Small-Cell Lung Cancer

Purpose: Patients with non-small-cell lung cancer (NSCLC) in the Radiation Therapy Oncology Group (RTOG) 93-11 trial received radiation doses of 70.9, 77.4, 83.8, or 90.3 Gy. The locoregional control and survival rates were similar among the various dose levels. We investigated the effect of the gross tumor volume (GTV) on the outcome. Methods and Materials: The GTV was defined as the sum of the volumes of the primary tumor and involved lymph nodes. The tumor response, median survival time (MST), and progression-free survival (PFS) were analyzed separately for smaller ({<=}45 cm{sup 3}) vs. larger (>45 cm{sup 3}) tumors. Results: The distribution of the GTV was as follows: {<=}45 cm{sup 3} in 79 (49%) and >45 cm{sup 3} in 82 (51%) of 161 patients. The median GTV was 47.3 cm{sup 3}. N0 status and female gender were associated with better tumor responses. Patients with smaller ({<=}45 cm{sup 3}) tumors achieved a longer MST and better PFS than did patients with larger (>45 cm{sup 3}) tumors (29.7 vs. 13.3 months, p < 0.0001; and 15.8 vs. 8.3 months, p < 0.0001, respectively). Increasing the radiation dose had no effect on the MST or PFS. On multivariate analysis, only a smaller GTV was a significant prognostic factor for improved MST and PFS (hazard ratio [HR], 2.12, p = 0.0002; and HR, 2.0, p = 0.0002, respectively). The GTV as a continuous variable was also significantly associated with the MST and PFS (HR, 1.59, p < 0.0001; and HR, 1.39, p < 0.0001, respectively). Conclusions: Radiation dose escalation up to 90.3 Gy did not result in improved MST or PFS. The tumor responses were greater in node-negative patients and women. An increasing GTV was strongly associated with decreased MST and PFS. Future radiotherapy trials patients might need to use stratification by tumor volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Escalated Stereotactic Body Radiation Therapy for Patients With Intermediate- and High-Risk Prostate Cancer: Initial Dosimetry Analysis and Patient Outcomes

Purpose: To report the short-term clinical outcomes and acute and late treatment-related genitourinary (GU) and gastrointestinal (GI) toxicities in patients with intermediate- and high-risk prostate cancer treated with dose-escalated stereotactic body radiation therapy (SBRT). Methods and Materials: Between 2011 and 2014, 24 patients with prostate cancer were treated with SBRT to the prostate gland and proximal seminal vesicles. A high-dose avoidance zone (HDAZ) was created by a 3-mm expansion around the rectum, urethra, and bladder. Patients were treated to a minimum dose of 36.25 Gy in 5 fractions, with a simultaneous dose escalation to a dose of 50 Gy to the target volume away from the HDAZ. Acute and late GU and GI toxicity outcomes were measured according to the National Cancer Institute Common Terminology Criteria for Adverse Events toxicity scale, version 4. Results: The median follow-up was 25 months (range, 18-45 months). Nine patients (38%) experienced an acute grade 2 GU toxicity, which was medically managed, and no patients experienced an acute grade 2 GI toxicity. Two patients (8%) experienced late grade 2 GU toxicity, and 2 patients (8%) experienced late grade 2 GI toxicity. No acute or late grade ≥3 GU or GI toxicities were observed. The 24-month prostate-specific antigen relapse-free survival outcome for all patients was 95.8% (95% confidence interval 75.6%-99.4%), and both biochemical failures occurred in patients with high-risk disease. All patients are currently alive at the time of this analysis and continue to be followed. Conclusions: A heterogeneous prostate SBRT planning technique with differential treatment volumes (low dose: 36.25 Gy; and high dose: 50 Gy) with an HDAZ provides a safe method of dose escalation. Favorable rates of biochemical control and acceptably low rates of acute and long-term GU and GI toxicity can be achieved in patients with intermediate- and high-risk prostate cancer treated with SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of Property Composition Models For RPP-WTP LAW Glasses (Final Report)

This report describes the development of property-composition models for low-activity waste (LAW) glasses for the River Protection Project Waste Treatment Plant (RPP-WTP) at the Hanford site. The RPP-WTP will separate Hanford tank wastes into LAW and high-level waste (HLW) streams and each stream will be vitrified separately. The development of LAW and HLW glass formulations for the RPP-WTP has been reported previously and is an ongoing activity. Acceptable formulations must meet a variety of processability, product quality, and waste loading requirements that are dictated either by the RPP-WTP contract or by the characteristics of the particular treatment processes that have been selected. These requirements amount to constraints on the acceptable ranges of certain glass properties. These properties are determined first and foremost by the composition of the glass or glass melt. Thus, while there is no direct way of controlling the glass properties of interest during production, there are simple and extremely effective methods of achieving the same result by instead controlling the glass composition. This basic principle is no different from that used to produce enormous volumes of commercial glass to meet exacting product specifications. An essential difference in waste vitrification, however, is that one of the raw materials (the waste itself) can be subject to considerable compositional uncertainty and variability. Thus, waste vitrification facilities and associated process control systems (of which, the operating envelope in glass formulation space is a key part) must, of course, be designed to be robust with respect to such variations. The determination of quantitative relationships between the glass properties that must be controlled and the glass composition can play an important role in the development of such facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Magnus: A New Resistive MHD Code with Heat Flow Terms

We present a new magnetohydrodynamic (MHD) code for the simulation of wave propagation in the solar atmosphere, under the effects of electrical resistivity—but not dominant—and heat transference in a uniform 3D grid. The code is based on the finite-volume method combined with the HLLE and HLLC approximate Riemann solvers, which use different slope limiters like MINMOD, MC, and WENO5. In order to control the growth of the divergence of the magnetic field, due to numerical errors, we apply the Flux Constrained Transport method, which is described in detail to understand how the resistive terms are included in the algorithm. In our results, it is verified that this method preserves the divergence of the magnetic fields within the machine round-off error (∼1×10{sup −12}). For the validation of the accuracy and efficiency of the schemes implemented in the code, we present some numerical tests in 1D and 2D for the ideal MHD. Later, we show one test for the resistivity in a magnetic reconnection process and one for the thermal conduction, where the temperature is advected by the magnetic field lines. Moreover, we display two numerical problems associated with the MHD wave propagation. The first one corresponds to a 3D evolution of a vertical velocity pulse at the photosphere–transition–corona region, while the second one consists of a 2D simulation of a transverse velocity pulse in a coronal loop.

79 ASTRONOMY AND ASTROPHYSICS↗

Patient geometry-driven information retrieval for IMRT treatment plan quality control

Purpose: Intensity modulated radiation therapy (IMRT) treatment plan quality depends on the planner's level of experience and the amount of time the planner invests in developing the plan. Planners often unwittingly accept plans when further sparing of the organs at risk (OARs) is possible. The authors propose a method of IMRT treatment plan quality control that helps planners to evaluate the doses of the OARs upon completion of a new plan. Methods: It is achieved by comparing the geometric configurations of the OARs and targets of a new patient with those of prior patients, whose plans are maintained in a database. They introduce the concept of a shape relationship descriptor and, specifically, the overlap volume histogram (OVH) to describe the spatial configuration of an OAR with respect to a target. The OVH provides a way to infer the likely DVHs of the OARs by comparing the relative spatial configurations between patients. A database of prior patients is built to serve as an external reference. At the conclusion of a new plan, planners search through the database and identify related patients by comparing the OAR-target geometric relationships of the new patient with those of prior patients. The treatment plans of these related patients are retrieved from the database and guide planners in determining whether lower doses delivered to the OARs in the new plan are feasible. Results: Preliminary evaluation is promising. In this evaluation, they applied the analysis to the parotid DVHs of 32 prior head-and-neck patients, whose plans are maintained in a database. Each parotid was queried against the other 63 parotids to determine whether a lower dose was possible. The 17 parotids that promised the greatest reduction in D{sub 50} (DVH dose at 50% volume) were flagged. These 17 parotids came from 13 patients. The method also indicated that the doses of the other nine parotids of the 13 patients could not be reduced, so they were included in the replanning process as controls. Replanning with an effort to reduce D{sub 50} was conducted on these 26 parotids. After replanning, the average reductions for D{sub 50} of the 17 flagged parotids and nine unflagged parotids were 6.6 and 1.9 Gy, respectively. These results demonstrate that the quality control method has accurately identified not only the parotids that require dose reductions but also those for which dose reductions are marginal. Originally, 11 of out the 17 flagged parotids did not meet the Radiation Therapy Oncology Group sparing goal of V(30 Gy)<50%. Replanning reduced them to three. Additionally, PTV coverage and OAR sparing of the original plans were compared to those of the replans by using pairwise Wilcoxon p test. The statistical comparisons show that replanning compromised neither PTV coverage nor OAR sparing. Conclusions: This method provides an effective quality control mechanism for evaluating the DVHs of the OARs. Adoption of such a method will advance the quality of current IMRT planning, providing better treatment plan consistency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-72: A Retrospective Correlation Analysis On Dose-Volume Control Points and Treatment Outcomes

Purpose: To quantify correlation between dose-volume control points and treatment outcomes. Specifically, two outcomes are analyzed: occurrence of radiation induced dysphagia and target complications. The results inform the treatment planning process when competing dose-volume criteria requires relaxations. Methods: 32 patients, treated with whole-field sequential intensity modulated radiation therapy during 2009–2010 period, are considered for this study. Acute dysphagia that is categorized into 3 grades is observed on all patients. 3 patients are observed in grade 1, 17 patients in grade 2, and 12 patients in grade 3. Ordinal logistic regression is employed to establish correlations between grades of dysphagia and dose to cervico-thoracic esophagus. Particularly, minimum (Dmin), mean (Dmean), and maximum (Dmax) dose control points are analyzed. Additionally, target complication, which includes local-regional recurrence and/or distant metastasis, is observed on 4 patients. Binary logistic regression is used to quantify correlation between target complication and four dose control points. Namely, ICRU recommended dose control points, D2, D50, D95, and D98 are analyzed. Results: For correlation with dysphagia, Dmin on cervico-thoracic esophagus is statistically significant (p-value = 0.005). Additionally, Dmean on cervico-thoracic esophagus is also significant in association with dysphagia (p-value = 0.012). However, no correlation was observed between Dmax and dysphagia (p-value = 0.263). For target complications, D50 on the target is a statistically significant dose control point (p-value = 0.032). No correlations were observed between treatment complications and D2 (p-value = 0.866), D95 (p-value = 0.750), and D98 (p-value = 0.710) on the target. Conclusion: Significant correlations are observed between radiation induced dysphagia and Dmean (and Dmin) to cervico-thoracic esophagus. Additionally, correlation between target complications and median dose to target (D50) is observed. Quantification of these correlations can inform treatment planners when any competing objectives requires relaxation of target D50 or Dmean (or Dmin) to cervico-thoracic esophagus.

60 APPLIED LIFE SCIENCES↗

Reporting the Radionuclide Inventory of the DWPF Product

In the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS), the radionuclides contained in the liquid high-level waste currently stored at SRS are being converted into a durable borosilicate glass. This glass in its sealed stainless-steel canister, the DWPF product, eventually must be sent to a federal repository for final disposal. In order to ensure that the DWPF product is suitable for acceptance by the U. S. Department of Energy’s (DOE) Civilian Radioactive Waste Management System (CRWMS)*, the DOE Office of Environmental Management (DOE-EM) established the Waste Acceptance Product Specifications for Vitrified High-Level Waste Forms (WAPS). DOE-EM is tentatively performing surrogate CRWMS waste acceptance functions, as the office was eliminated in 2009, for review and concurrence of technical baseline documents and waste form non conformances. The specifications are divided into five sections, dealing with the waste form (borosilicate glass) itself, the canister, the canistered waste form, quality assurance, and documentation and other administrative requirements. The DWPF is required to document its compliance with the specifications in the Waste Form Compliance Plan (WCP), the Waste Form Qualification Report (WQR), the Production Records, and the Storage and Shipping Records. The WCP provides general information about the DWPF process and product, and a general description of the methods and programs by which the DWPF will demonstrate compliance with each specification in the WAPS. The WCP was vital to DWPF startup with respect to operations planning and also assurance to DOE that the canistered waste forms would be acceptable for disposal at any future High-Level Waste (HLW) geologic repository. The WQR is a compilation of the results of the testing and analysis programs identified in the WCP. The WQR details the method of compliance with each specification, and the testing performed to demonstrate the effectiveness of each method. The WQR is published in separate volumes which each correspond to one or more of the specifications. The WQR also contains a description of the DWPF’s Glass Product Control Program. Each volume contains Part and Item designators which indicate the corresponding item(s) in the WCP. The Production Records, and the Storage and Shipping Records document that each DWPF product has been produced and stored in compliance with the WAPS. This document, Volume 4 of the WQR, responds to WAPS Specifications 1.2.2, 1.6, and 3.14 which require that the DWPF report the radionuclide inventory of each canistered waste form, and of each waste type. This volume describes the systems the DWPF uses to determine and report the radionuclide inventory of the glass product, and provides evidence that these systems allow the DWPF to satisfy the WAPS specification. This volume of the WQR has been prepared to establish that methods are available to determine and report the radionuclide inventory, and that the DWPF is ready to collect the facility-specific data necessary to provide definitive estimates of the errors associated with the use of these methods.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Applying Infrared Thermography as a Quality-Control Tool for the Rapid Detection of Proton-Electrolyte-Membrane-Fuel-Cell Catalyst-Layer-Thickness Variations

As fuel cells become more prominent, new manufacturing and production methods are needed to enable increased volumes with high quality. One necessary component of this industrial growth will be the accurate measurement of the variability of a wide range of material properties during the manufacturing process. In this study, a method to detect defects in fuel cell catalyst layers is investigated through experiment and mathematical simulation. The method uses infrared thermography and direct-current electronic-excitation methods to detect variations in platinum-containing catalyst-layer thickness with high spatial and temporal resolution. Data analysis, operating-condition impacts, and detection limits are explored, showing the measurement of defects on the millimeter length scale. Overall, the experimental and modeling results demonstrate great potential of this technique as a nondestructive method to measure defects that is amenable to use on roll-to-roll manufacturing lines.

08 HYDROGEN↗

Adaptive Image-Guided Radiotherapy (IGRT) Eliminates the Risk of Biochemical Failure Caused by the Bias of Rectal Distension in Prostate Cancer Treatment Planning: Clinical Evidence

Purpose: Rectal distension has been shown to decrease the probability of biochemical control. Adaptive image-guided radiotherapy (IGRT) corrects for target position and volume variations, reducing the risk of biochemical failure while yielding acceptable rates of gastrointestinal (GI)/genitourinary (GU) toxicities. Methods and Materials: Between 1998 and 2006, 962 patients were treated with computed tomography (CT)-based offline adaptive IGRT. Patients were stratified into low (n = 400) vs. intermediate/high (n = 562) National Comprehensive Cancer Network (NCCN) risk groups. Target motion was assessed with daily CT during the first week. Electronic portal imaging device (EPID) was used to measure daily setup error. Patient-specific confidence-limited planning target volumes (cl-PTV) were then constructed, reducing the standard PTV and compensating for geometric variation of the target and setup errors. Rectal volume (RV), cross-sectional area (CSA), and rectal volume from the seminal vesicles to the inferior prostate (SVP) were assessed on the planning CT. The impact of these volumetric parameters on 5-year biochemical control (BC) and chronic Grades {>=}2 and 3 GU and GI toxicity were examined. Results: Median follow-up was 5.5 years. Median minimum dose covering cl-PTV was 75.6 Gy. Median values for RV, CSA, and SVP were 82.8 cm{sup 3}, 5.6 cm{sup 2}, and 53.3 cm{sup 3}, respectively. The 5-year BC was 89% for the entire group: 96% for low risk and 83% for intermediate/high risk (p < 0.001). No statistically significant differences in BC were seen with stratification by RV, CSA, and SVP in quartiles. Maximum chronic Grades {>=}2 and 3 GI toxicities were 21.2% and 2.9%, respectively. Respective values for GU toxicities were 15.5% and 4.3%. No differences in GI or GU toxicities were noted when patients were stratified by RV. Conclusions: Incorporation of adaptive IGRT reduces the risk of geometric miss and results in excellent biochemical control that is independent of rectal volume/distension while maintaining very low rates of chronic GI toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RadVolViz: An Information Display-Inspired Transfer Function Editor for Multivariate Volume Visualization

In volume visualization transfer functions are widely used for mapping voxel properties to color and opacity. Typically, volume density data are scalars which require simple 1D transfer functions to achieve this mapping. If the volume densities are vectors of three channels, one can straightforwardly map each channel to either red, green or blue, which requires a trivial extension of the 1D transfer function editor. Here, we devise a new method that applies to volume data with more than three channels. These types of data often arise in scientific scanning applications, where the data are separated into spectral bands or chemical elements. Our method expands on prior work in which a multivariate information display, RadViz, was fused with a radial color map, in order to visualize multi-band 2D images. In this work, we extend this joint interface to blended volume rendering. The information display allows users to recognize the presence and value distribution of the multivariate voxels and the joint volume rendering display visualizes their spatial distribution. We design a set of operators and lenses that allow users to interactively control the mapping of the multivariate voxels to opacity and color. This enables users to isolate or emphasize volumetric structures with desired multivariate properties. Furthermore, it turns out that our method also enables more insightful displays even for RGB data. We demonstrate our method with three datasets obtained from spectral electron microscopy, high energy X-ray scanning, and atmospheric science.

36 MATERIALS SCIENCE↗

POINT: Partially Observable Imitation Network for Traffic Signal Control

Smart traffic signals bring together transportation infrastructure and advance technologies to improve the mobility and efficiency of urban transportation network. Adaptive traffic signal control studies can be categorized into modeling-based approaches and learning-based approaches. In order to take advantages of these two systems, this study developed an offline-online combined Partial Observable Imitation Network for Traffic signal control (POINT). In the offline system, the traffic signal timing optimization problem was formulated as a Mixed Integer Nonlinear Programming (MINLP) given complete traffic information, i.e., second-by-second speeds and locations of all vehicles. Furthermore, the objective of MINLP is to minimize total travel delays considering individual vehicle trajectories under Connected Vehicle (CV) environment. The calculated optimal solutions under various traffic conditions were considered as the ”expert” decisions. In the online system, an imitation neural network model was developed to learn the ”expert” signal plans generated from offline system. Given partial observable traffic conditions in real time, e.g., the aggregate-level of traffic volume, the POINT model can compute the signal timing parameters in the online system. The numerical results demonstrated that the proposed method outperformed other state-of-the-art signal control method under high and unbalanced traffic demand levels in terms of reducing travel delays and queue length.

33 ADVANCED PROPULSION SYSTEMS↗

Development of Dose-Volume Relation Model for Gamma Knife Surgery of Non-Skull Base Intracranial Meningiomas

Purpose: To provide a dose-volume relationship for gamma knife surgery (GKS) of non-skull base intracranial meningiomas. Methods and Materials: The radiologic outcomes of GKS of 82 imaging-defined benign meningiomas located at non-skull base areas were analyzed. A total of 80 patients were included and all underwent treatment with GKS as the first and the only treatment modality. The mean patient age was 55.0 years (range, 26-78) and the mean tumor volume was 5.6 cm{sup 3} (range, 0.5-16.8). On average, 14.6 Gy (range, 10-20) was applied to the 50% isodose surface. The binary logistic regression method was applied to find prognostic factors of signal change (SC) on T{sub 2}-weighted magnetic resonance imaging after GKS. Results: The actuarial tumor control rate was 91.6% at 5 years. A total of 29 lesions (35.4%) showed newly developed or aggravated SCs. The volume irradiated {>=}14 Gy was the only statistically significant (p < .01) prognostic factor of SC. A dose-volume relation model obtained from the cases without SC estimated a 12.2% SC probability. Conclusion: This model can be used in GKS to treat small- to medium-size (<9.2 cm{sup 3}) non-skull base meningiomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of synthesis conditions on the nanopowder properties of Ce{sub 0.9}Zr{sub 0.1}O{sub 2}

Graphical abstract: . The synthesis of nanocrystalline Ce{sub 0.9}Zr{sub 0.1}O{sub 2} powders via the gel-combustion method, using different fuels, and following either stoichiometric or non-stoichiometric pH-controlled routes is investigated. Research highlights: {yields} All samples exhibited the fluorite-type crystal structure, nanometric average crystallite size and negligible carbon content. {yields} Synthesis conditions strongly affect the average crystallite size, the degree of agglomeration, the specific surface area and the pore volume. {yields} Our results indicate that, by controlling the synthesis conditions it is possible to obtain solids with custom-made morphological properties. -- Abstract: In this work, the synthesis of nanocrystalline Ce{sub 0.9}Zr{sub 0.1}O{sub 2} powders via the gel-combustion method, using different fuels, and following either stoichiometric or non-stoichiometric pH-controlled routes is investigated. The objective is to evaluate the effect of synthesis conditions on the textural and morphological properties, and the crystal structure of the synthesized materials. The solids were characterized by nitrogen physisorption, Scanning Electron Microscopy (SEM), X-ray powder diffraction (XPD), and Carbon-Hydrogen-Nitrogen Elemental Analysis (CHN). All the powders exhibited nanometric crystallite size, fluorite-type structure and negligible carbon content. Synthesis conditions strongly affect the average crystallite size, the degree of agglomeration, the specific surface area and the pore volume. Our results indicate that, by controlling the synthesis conditions it is possible to obtain solids with custom-made morphological properties.

36 MATERIALS SCIENCE↗

Stretchable Mould Interconnect Optimization: Peeling Automation and Carrierless Techniques

The primary bottleneck of the stretchable mold interconnect (SMI) technology is its reliance on carrier boards. These are necessary to handle the meandered circuit during production and to ensure dimensional stability of the flexible circuit board before encapsulation. However, for all the problems it solves, it also introduces a new major problem by requiring a peeling step – which is difficult to automate. This manuscript aims to present some of the work that went into eliminating this problem, discussing both unsuccessful and functioning methods to tackle this conundrum and some of the experimental work that went into verifying these techniques. First, alterations to the design to simplify peeling are considered, followed by adhesivebased peeling processes and mechanical pin-based systems. Next, masking and structuring of the carrier board adhesive are considered. Finally, two carrierless methods which circumvent the problems are discussed, a two-step process – which cuts temporary support structures after partial encapsulation – and a technique whereby the frame is designed to fail in a controlled manner during the first use of the circuit, creating a carrierless process feasible for high-volume production.

Plovie, Bart↗

Relating Dose Outside the Prostate With Freedom From Failure in the Dutch Trial 68 Gy vs. 78 Gy

Purpose: For prostate cancer patients at risk for subclinical spread of the disease, we investigated whether incidental dose outside the target was associated with tumor control. Methods and Materials: We selected 352 intermediate-risk (mainly T2b-T3a) and high-risk (mainly T3b) patients treated in a randomized trial. Target volume was prostate (68-78 Gy) and seminal vesicles (50-78 Gy). Failure (clinical or biochemical) was evaluated at 4 years. To compare three-dimensional dose distributions, an automated mapping procedure was introduced. Between patients, these maps provide an approximate identification of corresponding anatomical locations. Maps of the dose difference between patients with and without failure were constructed. Univariate and multivariate analyses were performed including the dose in selected points. Results: Dose differences were mainly found in the obturatorial region for the high-risk patients, and in the presacral region for the intermediate risk group (>7 Gy, p < 0.01). Univariate hazard ratios per 10 Gy for selected dose points were 0.83 (p = 0.01, obturatorial) and 0.72 (p = 0.002, presacral). These hazard ratios were stable under multivariate analysis correcting for established prognostic factors, hospital, and dose to the prostate. Conclusions: Patients without failure have received on average a higher dose to regions where regional cancer spread could be expected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Planning Target Volume D95 and Mean Dose Should Be Considered for Optimal Local Control for Stereotactic Ablative Radiation Therapy

Purpose: To identify the optimal dose parameters predictive for local/lobar control after stereotactic ablative radiation therapy (SABR) in early-stage non-small cell lung cancer (NSCLC). Methods and Materials: This study encompassed a total of 1092 patients (1200 lesions) with NSCLC of clinical stage T1-T2 N0M0 who were treated with SABR of 50 Gy in 4 fractions or 70 Gy in 10 fractions, depending on tumor location/size, using computed tomography-based heterogeneity corrections and a convolution superposition calculation algorithm. Patients were monitored by chest CT or positron emission tomography/CT and/or biopsy after SABR. Factors predicting local/lobar recurrence (LR) were determined by competing risk multivariate analysis. Continuous variables were divided into 2 subgroups at cutoff values identified by receiver operating characteristic curves. Results: At a median follow-up time of 31.7 months (interquartile range, 14.8-51.3 months), the 5-year time to local recurrence within the same lobe and overall survival rates were 93.8% and 44.8%, respectively. Total cumulative number of patients experiencing LR was 40 (3.7%), occurring at a median time of 14.4 months (range, 4.8-46 months). Using multivariate competing risk analysis, independent predictive factors for LR after SABR were minimum biologically effective dose (BED{sub 10}) to 95% of planning target volume (PTVD95 BED{sub 10}) ≤86 Gy (corresponding to PTV D95 physics dose of 42 Gy in 4 fractions or 55 Gy in 10 fractions) and gross tumor volume ≥8.3 cm{sup 3}. The PTVmean BED{sub 10} was highly correlated with PTVD95 BED{sub 10.} In univariate analysis, a cutoff of 130 Gy for PTVmean BED{sub 10} (corresponding to PTVmean physics dose of 55 Gy in 4 fractions or 75 Gy in 10 fractions) was also significantly associated with LR. Conclusions: In addition to gross tumor volume, higher radiation dose delivered to the PTV predicts for better local/lobar control. We recommend that both PTVD95 BED{sub 10} >86 Gy and PTVmean BED{sub 10} >130 Gy should be considered for SABR plan optimization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗