Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Direct Air Capture Using Trapped Small Amines in Hierarchical Nanoporous Capsules on Porous Electrospun Fibers (Final Technical Report)

This report summarizes the carbon capture research and development conducted by The State University of New York at Buffalo (UB) and GTI Energy (GTI) for award “DE-FE0031969: Direct Air Capture Using Trapped Small Amines in Hierarchical Nanoporous Capsules on Porous Electrospun Fibers” sponsored by the U.S. Department of Energy (DOE). The objective of this project is to develop an innovative sorbent structure of trapped small amines in HNC embedded in PEF for DAC. This involves tailoring both sorbent and PEF materials to achieve a compact system for DAC with high capacity for CO 2 at concentrations typically available in air and at near ambient conditions. An innovative sorbent structure of trapped small amines in hierarchical nanoporous capsules (HNC) embedded in porous electrospun fibers (PEF) was developed for direct air capture (DAC). This involves tailoring both sorbent and PEF materials to achieve a compact system for DAC with high capacity for CO 2 at concentrations typically available in air and at near ambient conditions. An interfacial polymerization process was developed, which utilized loaded amines inside mesoporous silica and trimesoyl chloride (TMC) dissolved in organic solvents as the precursors, to generate a polyamide (PA) coating layer on mesoporous silica and thus trap amines. Reaction conditions, including TMC concentration, organic solvents, reaction time, etc., for interfacial polymerization were optimized to effectively trap loaded amines, and cyclic heating-cooling operation was conducted to evaluate the coating quality. Larger pore volume mesoporous silica was also synthesized to increase amine loading and thus increase CO 2 capacity. The optimized sorbent material exhibited CO 2 capacity as high as 4.88 mmol/g under humid DAC conditions and negligible loss (<1%) during 10 cyclic heating-cooling operations. The optimized PA-coated sorbent also showed fast adsorption and desorption kinetics, with <20% t1/2 increase compared to uncoated sorbent. PEF fabrication conditions, including organic solvents for dissolving core and shell polymers, voltage, distance from the nozzle to the collection panel, etc. were adjusted to better incorporate HNC. After incorporating the optimized sorbent material into PEF, the structured sorbent had a CO 2 capacity of approximately 4.0 mmol/g under humid DAC conditions, with capacity loss of 0.17% per cycle and t1/2 increase less than 10%. A techno-economic analysis (TEA) for the process design for a DAC system based on our developed sorbent structure of trapped small amines in HNC embedded in PEF was conducted. The process design included process description and major equipment sizing and energy and mass balances in addition to scale-up research results and estimated capture cost. Aspen Adsorption Simulator was used to fit the experimentally measured breakthrough curves and extract equilibrium and kinetic data of the optimized sorbent. Our results indicated that for a DAC plant with CO 2 productivity of 3,000 tonne/year, the levelized cost of CO 2 capture was $\$$612/tonne, with the largest contribution of 44.33% from the fixed operation cost. Increasing CO 2 productivity, while maintaining similar fixed operation cost, is expected to significantly reduce the CO 2 capture cost. A sensitivity study was also conducted to understand the influence of total plant cost, sorbent cost, CO 2 concentration in the feed, sorbent mat lifetime, sorbent regeneration electricity, and adsorption blower pressure drop on the levelized cost of CO 2 capture, revealing a capture cost range of $\$$520-870/tonne.

36 MATERIALS SCIENCE↗

Efficiency and Demand Flexibility in Large Office Buildings: The Potential for Cost Savings and CO 2 Reductions from Lighting and Cooling Measures

This report presents the estimated impact of lighting and cooling efficiency and demand flexibility measures in large office buildings in each state in the contiguous United States. It provides modeled results for three different metrics: bill savings, regional grid operational costs savings, and carbon dioxide (CO 2 ) emissions reductions. Lighting efficiency and demand flexibility are estimated to reduce load by up to 80 MWh/yr in a single large office building. These load reductions result in customer bill savings of up to $8,800/yr per building, with the highest savings in southern and midwestern states. Grid operating cost savings are estimated at up to $3,240/yr/building, with greatest benefit in southern and northeastern states. CO 2 emissions reduction potential is highest in the Dakotas, Nebraska, across the Midwest, in West Virginia, and in Mississippi (<48,200 kg/yr/building). Comparatively, cooling measures are found to have less load reduction potential (<28.5 MWh/yr/building), with the greatest potential in southern states including Texas, which ranks top of the list across several of the metrics studied. In numerous states, shifting cooling load to off-peak hours is found to increase costs and CO 2 emissions because precooling results in increased load during high-cost or high-CO 2 emissions periods. In general, focusing on cooling efficiency and load shedding has the potential for more savings. In all cases, the specific rate structure is a significant determinant in actual bill savings, which are up to $4,000/yr/building. To realize the full potential for bill savings through an energy measure, building operators must identify how the measure will change the building load pattern and the interaction of this load change with the applicable rate tariff. To realize CO 2 emissions reductions, industry and state coordination is needed to verify which fuel source is on the margin and then to create incentives for end users to reduce load during high-CO 2 emissions hours. Regular updates to data sets and analyses are critical. Regulators and policymakers are well positioned to facilitate the necessary coordination between the electric industry and building energy managers to develop appropriate price signals and incentives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiative Cooling of a Superconducting Resonator

Cooling microwave resonators to near the quantum ground state, crucial for their operation in the quantum regime, is typically achieved by direct device refrigeration to a few tens of millikelvin. However, in quantum experiments that require high operation power such as microwave-to-optics quantum transduction, it is desirable to operate at higher temperatures with non-negligible environmental thermal excitations, where larger cooling power is available. In this Letter, we present a radiative cooling protocol to prepare a superconducting microwave mode near its quantum ground state in spite of warm environment temperatures for the resonator. In this proof-of-concept experiment, the mode occupancy of a 10 GHz superconducting resonator thermally anchored at 1.02 K is reduced to 0.44 ± 0.05 from 1.56 by radiatively coupling to a 70 mK cold load. We report this radiative cooling scheme allows high-operation-power microwave experiments to work in the quantum regime, and opens possibilities for routing microwave quantum states to elevated temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Overall Cooling Effectiveness of Internally Cooled Additively Manufactured Blades

Power generation gas turbine blades must utilize highly effective cooling schemes to withstand moderate heat loads for long operating times. Prior work indicates that gas turbines in the 5-10 MW range primarily utilize internal cooling to prevent further increase of aerodynamic losses that result from film cooling, but few studies focus solely on internal cooling. In this study, three additively manufactured internal cooling designs were tested in the 50 percent span section of the National Experimental Turbine (NExT) blade: a baseline cooling design with pin-fin arrays and rib turbulators, a double wall design with impingement jets and serpentine channels, and an incremental impingement design. The designs were tested in a high-speed linear cascade at exit Reynolds numbers ranging from 700,000 to 1,400,000 at an exit Mach of 0.8. In addition, freestream turbulence and build angle effects on cooling performance were studied.

gas turbine blades↗

EXPERIMENTAL AND MODELLING ANALYSIS OF A LARGE-SCALE TWO-PHASE LOOP THERMOSYPHON

Liquid pumping requires large quantities of electrical energy, including about 7% of the energy of building heating, ventilation, and air conditioning (HVAC) systems. To replace pumped condenser-cooling tower water loops with a passive alternative system, we implemented a commercial-scale two-phase loop thermosyphon (TPLT). The unit consists of a 13 m riser integrated with a commercially available cooling tower and circulation water heater that simulates heat loads up to 25 kW. In addition to providing passive cooling capabilities, the cooling tower unit is also maintenance free, reliable, and can operate in both dry and wet modes. This study characterizes the performance (temperature difference between the evaporator and condenser) and the two-phase flow behavior of the loop under various refrigerant charges. Sight glasses installed throughout the loop are used to identify the operating flow regimes in the riser and downcomer. Over the range of operating conditions, we identified that there is an optimal refrigerant charge range for a specific heat load at which near-isothermal operation can be achieved. We further developed a model to predict the operating flow rate and gravitational height in the downcomer and compared it with the experimental data. The results show that the model agrees with the experimental data, in particular the threshold gravitational head height at which there will be subcooled liquid at the condenser exit, indicating that it can be used as a predictive tool for identifying the optimal loop charge for a given heat load.

Loop thermosyphon, passive two phase↗

GAMBL – A dual-cooled fusion blanket using SiC-based structures

We describe a novel fusion reactor blanket concept called GAMBL – GA Modular BLanket. This design concept exploits the advantages of SiC-based structures while minimizing their limitations. Material microstructures are tailored for different functions throughout the first wall and blanket, including the use of graded W/SiC composites to enhance heat transfer capabilities and resist erosion at the plasma-facing surface. The design contains a decoupled first wall and breeding blanket, which we show can provide adequate tritium breeding. By decoupling the breeding part of the blanket, we can operate at very low PbLi breeder pressure and support gravity loads in simple, radiatively-cooled structural beams that do not contain coolant. First wall performance capabilities are enhanced by eliminating constraints imposed by the deep blanket. We have performed initial fluid, thermal, mechanical and neutronics analysis of this concept to show its capabilities to meet the design requirements. R&D needs are mostly related to materials development. Except for unique manufacturing needs, no new facilities are required beyond existing or planned facilities for the US base program on steel-based DCLL blankets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Abnormal grain growth of 68Cu–16Al–16Zn alloys for elastocaloric cooling via cyclical heat treatments

Abstract Cu-based superelastic shape memory alloys are promising for low-stress elastocaloric cooling. We have synthesized bulk alloys of 68Cu–16Al–16Zn under different conditions in order to promote its grain growth and enhance its elastocaloric properties. High-temperature x-ray diffraction of untreated 68Cu–16Al–16Zn alloy showed that the phase boundary between the α + β mixed phases and the high temperature phase ( β phase) was between 973 K and 1023 K. Based on this result, the 68Cu–16Al–16Zn alloy was heated and cooled in a furnace repeatedly between 773 K and 1173 K. The maximum grain size after heat treatment of the ingot rolled to 67% reached 11.1 mm. The latent heat of the martensitic transformation after grain growth was 6.3 J g −1 , which is higher than the previously reported value for the compound. The stress–strain curve of 68Cu–16Al–16Zn rolled to 67% rolling with cyclical heat treatments showed a maximum stress of 106 MPa at 4.5% strain, with adiabatic temperature change of 5.9 K in heating during stress loading and 5.6 K in cooling in stress removal. Furthermore, no fatigue in the stress–strain behavior was observed up to at least 60 000 mechanical cycles at 2% strain.

36 MATERIALS SCIENCE↗

Exploring Grid-Interactive Efficient Building Strategies for Laboratories Through Energy Modeling

Laboratories are often overlooked in demand flexibility research due to constraints on their operations as mission critical facilities, despite the major role they play in an organization's emissions. Laboratories consume 3-4 times more energy than a typical office building and are commonly the largest energy users on any campus. Consequently, most laboratories in the United States are significant contributors to their organization's carbon footprint if their energy needs are met through the combustion of fossil fuels. As part of the initiative to decarbonize laboratories, this report documents an analysis on specifically grid-interactive efficient building (GEB) opportunities for reducing energy costs and emissions associated with laboratory operations. The goal of this initiative was to provide a case study and guidance on how to use OpenStudio and REopt as modeling tools for GEB technologies and strategies in laboratory environments across different climate zones in the United States. The analysis found that efficiency-based GEB strategies had the most significant impact on laboratory operations, while load-shedding and load-shifting GEB strategies produced smaller results. The culmination of these approaches applied across all five climate zones generated on average: 1) 28% energy cost savings and 30% greenhouse gas (GHG) emissions reductions, and 2) 4% enhanced energy cost savings under a time-of-use (TOU) pricing schedule compared to traditional pricing schemes. Grid-interactive efficiency building measures were found to produce the greatest energy savings in both electricity and natural gas, particularly in regions with high electrical loads, such as warm climates for cooling. Laboratories that had high levels of natural gas consumption, meanwhile, experienced the greatest emission reductions. The report concludes with an analysis on the opportunities for flexible loads in lab spaces and how small-scale measures in addition to opaque pricing structures for peak demand could become barriers to demand flexibility planning. The report also explores how electrifying laboratory buildings with heat pumps could reduce energy costs and GHG emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Conceptual Design of a Conduction-Cooled Superconducting Undulator

In superconducting undulators (SCUs) that are currently operating at the Advanced Photon Source, the undulator magnets are indirectly cooled with liquid helium penetrating through channels in the magnet cores. The liquid helium is stored in a tank that is cooled by cryocoolers. However, a cryogen-free version of a superconducting undulator in which the undulator magnets are conduction-cooled is also possible, as has been realized in the SCUs developed at ANKA. We are currently working on a conceptual design of a conduction-cooled planar superconducting undulator. The measured load lines of cryocoolers and the measured thermal conductance of various thermal links are used in the thermal analysis. Also, various materials for the undulator magnet cores are being considered. This paper reports the thermal design of a conduction-cooled planar SCU.

cryocooler↗

Assessing the impacts of air-sealing on the sizing, operation, and economic feasibility of ground-source heat pumps for electrifying single-family houses in the US

According to recent studies and reports, in single-family houses (SFHs), air-sealing can significantly lower the thermal loads for space heating and cooling. Thus, air-sealing in SFHs could reduce the required size and cost of ground source heat pump (GSHP) systems for electrifying SFHs. Here, this study investigated the costs and benefits of integrating air-sealing with GSHPs for retrofitting existing SFHs when compared with air-source heat pumps. A whole building energy simulation tool integrated with an advanced design tool for modeling ground heat exchangers was used to calculate changes in required GSHP capacity, total borehole length, and building energy consumption with and without air-sealing in SFHs in 16 US climatic regions. The results from this study showed that reducing outdoor air infiltration from 0.8 air changes per hour (ACH) to the minimum ventilation requirement (0.35 ACH) can significantly reduce borehole length (up to 55 %), GSHP capacity (up to 48 %), and total heating electricity reduction, especially in cold climates (up to 44 %). The results also showed that for airtight homes (0.03 ACH infiltration) with a direct outdoor air system, the minimum required borehole length, GSHP capacity, and total heating electricity consumption can be reduced up to 70 %, 68 %, and 67 %, respectively, when compared with SFHs with 0.8 ACH infiltration. Moreover, the life cycle cost analysis showed that air-sealing in conjunction with a GSHP is more profitable than replacing the existing system with an air-source heat pump, even without any incentives for most climatic regions in the US (except for some hot regions).

15 GEOTHERMAL ENERGY↗

PIPII cryoplant non thermal cycling updates

The Proton Improvement Plan-II (PIP-II) is a crucial upgrade to the Fermilab accelerator complex, featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (LINAC) with 23 cryomodules operating at 2K. The LINAC thermohydraulic conditions are satisfied by the cryogenic subsystems: Cryogenic Distribution System (CDS), a helium refrigerator cold box (CB), a warm compression station (WCS) and a helium recovery system (RSYS). The accelerator has a strict requirement of non-thermal cycling of the LINAC cryomodules during planned and unplanned subsystem outages. This paper presents an integrated operating modes analysis of the of the LINAC/CDS thermohydraulic loads satisfied by the CB/WCS cooling system supported by the RSYS inventory management system. The study is based on latest cryoplant and CDS engineering deliverables, as well as the recent performance data from single cryomodule qualification tests performed at the Fermilab PIP-II Injector Test test s tand. The study evaluates both normal and abnormal operating modes, with a focus on identifying integrated scenarios that put subsystems components under stress. The conclusions of this study will help build redundancy to reduce the risk of thermal cycles during planned and unplanned subsystem outages.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advanced Reactors Integrated Energy System: Thermal Energy Storage Island Design

The main topic of this research is integrated energy systems (IES) designed for pairing industrial thermal energy loads with advanced reactors (ARs). The Idaho National Laboratory (INL) Crosscutting Technology Development IES program and the National Reactor Innovation Center (NRIC) are seeking to develop, design, and construct an AR-IES demonstration platform that couples the thermal output from an AR operating at the INL/NRIC Demonstration of Microreactor Experiments (DOME) test bed in the Experimental Breeder II dome to a variable capacity load emulator (i.e., air-cooled radiator) and sensible thermal energy storage (TES) via a molten salt thermal energy transfer fluid. In the rapidly evolving landscape of energy supply and distribution, flexibility has emerged as a prized attribute, surpassing the traditional notions of stability and baseload generation capability. This shift in priorities is particularly evident in the context of nuclear power plants (NPPs), where adaptability over constant output is becoming more important. As our energy infrastructure and resources embraces the rise of distributed energy generation, the inherent variability in net demand continues to grow. Moreover, the use of nuclear energy as a source of heat for decarbonizing the industrial sector is becoming a very pressing topic. In such environment, advanced NPPs are poised to enter a more competitive energy market, delivering both, flexible electricity and heat. This shift motivates the exploration of TES systems, designed to empower NPPs with nimble responsiveness to market fluctuations, flexible heat delivery capabilities, and redefine their role in the energy field. TES systems offer the unique advantage of storing nuclear energy in its original form as heat, thereby affording unparalleled flexibility in its subsequent utilization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES)

The C2SAGES project evaluated the feasibility of a community geothermal system for the planned Windy Ridge affordable housing development in Hinesburg, Vermont. Led by GTI Energy with Vermont Gas Systems, LN Consulting, NREL, and Frontier Energy, the work assessed technical design, energy performance, costs, business models, community engagement, maintenance, workforce development, and permitting. The proposed system was designed to serve 100% of the development’s heating, cooling, and domestic hot water loads. Compared with a baseline using air-source heat pumps and natural gas water heating, the geothermal system was estimated to reduce HVAC and domestic hot water energy use by about 45% to 48%, lower operating and maintenance costs, and reduce 30-year life-cycle costs by 37% for Phase 1 and 10% for Phase 2. Technical testing and modeling indicated that the Windy Ridge site is suitable for a community-scale geothermal system. The project also developed borehole field layouts, piping concepts, pump house designs, controls, maintenance plans, and supporting engineering drawings. The business model analysis found that first cost, ownership structure, and customer affordability remain major deployment challenges. Utility-led maintenance and operation were viewed favorably, but traditional utility cost-recovery models may require subsidy or revised financing structures to be practical for affordable housing. Community engagement highlighted the need for clear public education, transparent financing, reliable long-term maintenance, trained technicians, and the potential to pair geothermal systems with weatherization. Overall, the report concludes that community geothermal is technically feasible and offers meaningful energy, emissions, and life-cycle cost benefits, but broader deployment will depend on workable financing models and workforce readiness.

15 GEOTHERMAL ENERGY↗

Techno-Economic Analysis for the Addition of a Thermal Energy Storage System to a Central Plant

Increasing energy demand and rising peak loads present significant challenges for energy management in commercial and institutional settings. As climate change drives greater cooling needs, central plants must navigate the complex tradeoffs between operational efficiency, cost control, and grid stability. Thermal energy storage (TES) systems offer a viable solution by shifting energy consumption from peak to off-peak periods, thereby reducing peak demand, lowering utility expenses, and improving grid resilience. However, the success of TES implementation hinges on appropriate system sizing, effective control strategies, and alignment with local utility rate structures. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills. Drawing on historical load profiles and utility tariffs, we assess three TES sizing approaches and their corresponding control strategies from both energy and economic perspectives. This article utilizes a model-based approach to assess the impact of TES sizing and control strategies on the techno-economic feasibility of integrating TES into an existing central plant. The models employed for this analysis were calibrated using 4 years of historical data. Here, the results demonstrated that utility tariffs and the campus's operational profiles dictate the most feasible sizing and control methods. The findings offer valuable insights for institutions and commercial building managers exploring sustainable energy solutions. By demonstrating how optimized TES strategies can improve operational efficiency while achieving financial savings, this study highlights the potential for TES to align performance with cost effectiveness in real-world applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization of static heat loads of the PIP-II cryomodules based on prototype HB650 cryomodule test results

During the first cool down of the prototype HB650 cryomodule (pHB650 CM), high static heat loads have been measured compared to the estimation. Several analysis and calculations have been performed to explain this difference which led to cool down this cryomodule two additional times. Before each cool down, repairs and upgrades have been done, and instrumentations were added to identify the issues and quantify their impact on the heat loads. Based on these findings, the production cryomodule design and assembly process have been updated to align the future heat loads measurements with the estimations.

43 PARTICLE ACCELERATORS↗

Progress in Fast Modular Reactor Conceptual Design

The Fast Modular Reactor (FMR) is a 100-MW(thermal) gas-cooled fast reactor being developed by General Atomics Electromagnetic System with the goal of developing a FMR for flexible and dispatchable power to the U.S. electricity market in the mid-2030s. The conceptual design aims to develop and verify simplified design features. These include an inert helium gas coolant, pellet-loaded fuel rods, installations with air cooling as ultimate heat sink, and small and passive heat removal systems. The goal is to ensure the development of a safe, maintainable, cost-effective, and distributed nuclear energy-generating station. The baseline technologies selected to achieve this goal are a helium coolant that is an inert gas with no chemical reaction with structural components, not activated, single phase, enabling high-temperature operation and a high thermal efficiency Brayton cycle; conventional uranium dioxide (UO 2 ) fuel, which is the most widely used and well-known fuel material, capable of high burnup (100 MWd/kg) and a long fuel life; and silicon carbide composite (SiGA®) cladding and internal structures that are chemically inert in the helium environment, exceptionally radiation tolerant, and being derisked by accident tolerant fuel technology development. Further, the reactor was specifically designed with passive safety features, including high-temperature in-core materials and a reactor vessel cooling system consisting of cooling panels of naturally circulating water. The passive safety of the core was confirmed for the depressurized loss-of–forced cooling accident, which showed the peak cladding temperature at ~1600°C during the transient, which is below the current design limit of 1800°C. The conceptual design of the FMR has been conducted for the reactor system, vessel system, generator and turbomachine, instrumentation and control, residual heat removal system, plant service system, and containment, as well as pre-application licensing documents.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗