Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlated imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Multiscale Characterization of Additive Manufacturing Components with Computed Tomography, 3D X-ray Microscopy, and Deep Learning

Additive manufacturing (AM) facilitates the creation of complex-geometry parts, driving advancements in lightweight aerospace components, high-efficiency engine cooling channels, and customized medical implants. However, ensuring the quality and reliability of AM parts remains challenging due to internal defects, surface irregularities, porosity, and residual trapped powder, which are often inaccessible to traditional inspection methods. Recent developments in X-ray computed tomography (XCT) and 3D X-ray microscopy (XRM), particularly systems equipped with resolution-at-a-distance (RaaD™) capabilities, enable high-resolution, non-destructive evaluation of AM components across multiple scales, from sub-micrometer to macroscopic levels. This paper explores modern XCT and XRM techniques for multiscale characterization of AM parts, focusing on their ability to detect and analyze defects such as porosity, cracks, inclusions, and surface roughness, while offering insights into defect formation mechanisms, material properties, and process-induced variations. The integration of deep learning (DL) frameworks, including Simurgh, DeepRecon, and DeepScout, enhances XCT/XRM workflows by reducing scan times, improving resolution recovery, and enabling accurate defect detection even with limited projection data. These DL-based methods overcome limitations of traditional reconstruction techniques, enabling faster, more reliable characterization of dense materials like Inconel 718 and novel alloys such as AlCe. Applications include process parameter optimization, high-throughput quality control, and multistage AM process evaluation, with DL-enhanced workflows accelerating analysis times from weeks to days. Correlative imaging approaches further validate XCT and XRM data against scanning electron microscopy (SEM) images of physically sectioned samples, confirming the accuracy of DL-based reconstructions and enabling comprehensive defect analysis. While challenges remain in generalizing DL models to diverse materials and imaging conditions, improvements in resolution, noise reduction, and defect detection highlight the transformative potential of these methods. This multiscale and correlative approach enables precise identification and correlation of microstructural features with the overall performance of AM components. By integrating advanced XCT, XRM, and DL techniques, this paper demonstrates a significant leap forward in AM characterization, offering valuable insights into the relationships between processing parameters, microstructure, and part performance, and driving innovations that enhance the quality and reliability of AM products for demanding industrial applications.

Additive manufacturing↗

Ring Pull Strain Analysis

Ring Pull Strain Analysis (RPSA) is a framework for analysis of Digital Image Correlation (DIC) data of gaugeless ring pull testing. It is meant for analysis of rings cut from tube cross sections and pulled in a displacement-controlled tensile test. This code takes load frame data, images take during testing, and csv files from the DIC analysis of those images and allows the user to analyze and plot data from the test. Some important features of the software include getting the strain values as a function of radial distance and angle, plotting of the strain around the ring, and stress-strain analysis of the load frame data. Additional capability is included with Ring Pull Coating Analysis (RPCA, also part of the software). Additional images are taken of samples with an outer coating and are used to correlate failure of the coating with strain values measured with DIC.

Beck, Peter↗

Evolution of tensile and shear cracking in crystalline rocks under compression

Here we performed laboratory-scale unconfined compression experiments on Barre granite specimen with a single pre-existing flaw to study the evolution of tensile and shear cracking that occurs during different stress levels. Moment tensor inversion of acoustic emission (AE) events in combination with the nonelastic strain component obtained through the 2D digital image correlation (DIC) technique are used to track the changes in the source mechanisms of the stress-induced cracks. The mode of deformation computed from the image based strain profiles, enables visual comparison of the nucleation, growth and interaction of the tensile and shear cracks with the microseismic source mechanism observed by moment tensor inversion of the AE events. Comparing the results obtained from the two techniques on the same dataset demonstrates a quantitative correlation between the acoustic and visual observations in terms of the cracking mechanisms obtained at different stages of cracking from crack initiation at the flaw tips to the failure of the rock specimen.

58 GEOSCIENCES↗

Experimental Evaluation of Geopolymer, Nano-Modified, and Neat Class H Cement by Using Diametrically Compressive Tests

Abstract Cement is the prime barrier material to maintain zonal isolation during wellbore life-cycle. Different types of the cement have different performances on sealability. The primary objective of this study is evaluation of three types of cement systems, neat Class H, nano-synthetic graphite, and rock-based geopolymer cements, on interfacial bond integrity. Diametrical compressive tests are used on casing–cement–formation systems. Cement performances are tested in a conventional configuration (Berea Sandstone). A universal testing system is utilized to analyze the relationship applied load–axial strain and the digital image correlation (DIC) technique is used to generate the strain field maps. Based on the relationship and DIC results, bond strengths in different cement systems are evaluated. Additionally, microscope images provide insight explanations of the bond from micro-view. Based on the experimental results, failures of all cases initiate and propagate from the casing–cement interface. Then, radial cracks develop through the formation. This is because the mechanical interlocking bonds are formed only at the cement–sandstone interface to enhance the bond strength. The comparison of geopolymer and nano-modified cements with the conventional cement (neat Class H) shows that the unconventional cements have a lower maximum load and higher axial strain before failure of the samples. It indicates that both the two kinds of cements are more ductile than conventional cement and can support more deformation before the initiation of cracks.

Energy & Fuels↗

Hyperdimensional Imaging Contrast Using an Optical Fiber

Fluorescence properties of a molecule can be used to study the structural and functional nature of biological processes. Physical properties, including fluorescence lifetime, emission spectrum, emission polarization, and others, help researchers probe a molecule, produce desired effects, and infer causes and consequences. Correlative imaging techniques such as hyperdimensional imaging microscopy (HDIM) combine the physical properties and biochemical states of a fluorophore. Here we present a fiber-based imaging system that can generate hyper-dimensional contrast by combining multiple fluorescence properties into a single fluorescence lifetime decay curve. Fluorescence lifetime imaging microscopy (FLIM) with controlled excitation polarization and temporally dispersed emission can generate a spectrally coded, polarization-filtered lifetime distribution for a pixel. This HDIM scheme generates a better contrast between different molecules than that from individual techniques. This setup uses only a single detector and is simpler to implement, modular, cost-efficient, and adaptable to any existing FLIM microscope. We present higher contrast data from Arabidopsis thaliana epidermal cells based on intrinsic anthocyanin emission properties under multiphoton excitation. This work lays the foundation for an alternative hyperdimensional imaging system and demonstrates that contrast-based imaging is useful to study cellular heterogeneity in biological samples.

47 OTHER INSTRUMENTATION↗

Ring Pull Strain Analysis

Ring Pull Strain Analysis (RPSA) is a framework for analysis of Digital Image Correlation (DIC) data of gaugeless ring pull testing. It is meant for analysis of rings cut from tube cross sections and pulled in a displacement-controlled tensile test. This code takes load frame data, images take during testing, and csv files from the DIC analysis of those images and allows the user to analyze and plot data from the test. Some important features of the software include getting the strain values as a function of radial distance and angle, plotting of the strain around the ring, and stress-strain analysis of the load frame data.

Beck, Peter↗

Imaging from Macro to Nanoscale: Multimodal Advances in Chemical and Biomedical Imaging

Imaging increasingly serves as a multiscale framework for linking molecular mechanisms to cellular behavior, tissue architecture, and organ phenotypes in biology and unraveling fundamental processes in chemistry, physics and materials science. This Perspective highlights recent advances in chemical and biomedical imaging across macro-, micro-, and nanoscales, using representative examples published in Chemical and Biomedical Imaging (CBMI). At the macroscale, we discuss chemically selective MRI, including endogenous and exogenous CEST strategies, together with photoacoustic imaging as a hybrid modality with functional and chemical contrast. At the microscale, we consider fluorescence, label-free optical and vibrational imaging, and selected X-ray approaches that expand sensitivity, specificity, and temporal resolution in biological and materials systems. At the nanoscale, we highlight super-resolution fluorescence microscopy, single-molecule methods, tip-enhanced Raman spectroscopy, and correlative imaging strategies that resolve local heterogeneity and molecular organization. Across scales, a common theme emerges that advances in probes, contrast mechanisms, instrumentation, and sample handling are enabling chemically informed imaging that connects molecular specificity with biological context.

multiscale imaging↗

Correlating results from high resolution EBSD with TEM- and ECCI-based dislocation microscopy: Approaching single dislocation sensitivity via noise reduction

High resolution electron backscatter diffraction (HREBSD), an SEM-based diffraction technique, may be used to measure the lattice distortion of a crystalline material and to infer the geometrically necessary dislocation content. Uncertainty in the image correlation process used to compare diffraction patterns leads to an uneven distribution of measurement noise in terms of the lattice distortion, which results in erroneous identification of dislocation type and density. This work presents a method of reducing noise in HREBSD dislocation measurements by removing the effect of the most problematic components of the measured distortion. The method is then validated by comparing with TEM analysis of dislocation pile-ups near a twin boundary in austenitic stainless steel and with ECCI analysis near a nano-indentation on a tantalum oligocrystal. Finally, the HREBSD dislocation microscopy technique is able to resolve individual dislocations visible in TEM and ECCI and correctly identify their Burgers vectors.

36 MATERIALS SCIENCE↗

X-ray microscopy enables multiscale high-resolution 3D imaging of plant cells, tissues, and organs

Capturing complete internal anatomies of plant organs and tissues within their relevant morphological context remains a key challenge in plant science. While plant growth and development are inherently multiscale, conventional light, fluorescence, and electron microscopy platforms are typically limited to imaging of plant microstructure from small flat samples that lack a direct spatial context to, and represent only a small portion of, the relevant plant macrostructures. We demonstrate technical advances with a lab-based X-ray microscope (XRM) that bridge the imaging gap by providing multiscale high-resolution three-dimensional (3D) volumes of intact plant samples from the cell to the whole plant level. Serial imaging of a single sample is shown to provide sub-micron 3D volumes co-registered with lower magnification scans for explicit contextual reference. High-quality 3D volume data from our enhanced methods facilitate sophisticated and effective computational segmentation. Advances in sample preparation make multimodal correlative imaging workflows possible, where a single resin-embedded plant sample is scanned via XRM to generate a 3D cell-level map, and then used to identify and zoom in on sub-cellular regions of interest for high-resolution scanning electron microscopy. In total, we present the methodologies for use of XRM in the multiscale and multimodal analysis of 3D plant features using numerous economically and scientifically important plant systems.

59 BASIC BIOLOGICAL SCIENCES↗

Poisson’s ratio of eTPU molded bead foams in compression via in situ synchrotron X-ray microtomography

In situ synchrotron X-ray microtomography was used to characterize the bulk deformation behavior by computing the Poisson's ratio of expanded thermoplastic polyurethane (eTPU) molded bead foams used in footwear midsole during compression. Quantitative data on morphological characteristics were obtained using an iterative image processing workflow. Image correlation on the 4D datasets using DVC was performed to calculate the volumetric and axial strain to estimate the Poisson ratio. Strain maps from DVC showed the influence of variability in ligament thickness distribution on the global mechanical behavior exhibited which dominated the response seen in these bead foams. Lastly, our results showed a strong correlation between Poisson ratio and distribution of ligament thickness in foams.

36 MATERIALS SCIENCE↗

CD46-Targeted Theranostics for PET and 225 Ac-Radiopharmaceutical Therapy of Multiple Myeloma

Multiple myeloma is a plasma cell malignancy with an unmet clinical need for improved imaging methods and therapeutics. Recently, we identified CD46 as an overexpressed therapeutic target in multiple myeloma and developed the antibody YS5, which targets a cancer-specific epitope on this protein. We further developed the CD46-targeting PET probe [ 89 Zr]Zr-DFO-YS5 for imaging and [ 225 Ac]Ac-DOTA-YS5 for radiopharmaceutical therapy of prostate cancer. These prior studies suggested the feasibility of the CD46 antigen as a theranostic target in multiple myeloma. Herein, we validate [ 89 Zr]Zr-DFO-YS5 for immunoPET imaging and [ 225 Ac]Ac-DOTA-YS5 for radiopharmaceutical therapy of multiple myeloma in murine models. In vitro saturation binding was performed using the CD46 expressing MM.1S multiple myeloma cell line. ImmunoPET imaging using [ 89 Zr]Zr-DFO-YS5 was performed in immunodeficient (NSG) mice bearing subcutaneous and systemic multiple myeloma xenografts. For radioligand therapy, [ 225 Ac]Ac-DOTA-YS5 was prepared, and both dose escalation and fractionated dose treatment studies were performed in mice bearing MM1.S-Luc systemic xenografts. Tumor burden was analyzed using BLI, and body weight and overall survival were recorded to assess antitumor effect and toxicity. [ 89 Zr]Zr-DFO-YS5 demonstrated high affinity for CD46 expressing MM.1S multiple myeloma cells (K d = 16.3 nmol/L). In vitro assays in multiple myeloma cell lines demonstrated high binding, and bioinformatics analysis of human multiple myeloma samples revealed high CD46 expression. [ 89 Zr]Zr-DFO-YS5 PET/CT specifically detected multiple myeloma lesions in a variety of models, with low uptake in controls, including CD46 knockout (KO) mice or multiple myeloma mice using a nontargeted antibody. In the MM.1S systemic model, localization of uptake on PET imaging correlated well with the luciferase expression from tumor cells. A treatment study using [ 225 Ac]Ac-DOTA-YS5 in the MM.1S systemic model demonstrated a clear tumor volume and survival benefit in the treated groups. Our study showed that the CD46-targeted probe [ 89 Zr]Zr-DFO-YS5 can successfully image CD46-expressing multiple myeloma xenografts in murine models, and [ 225 Ac]Ac-DOTA-YS5 can effectively inhibit the growth of multiple myeloma. These results demonstrate that CD46 is a promising theranostic target for multiple myeloma, with the potential for clinical translation.

59 BASIC BIOLOGICAL SCIENCES↗

In situ , in vivo , and in operando imaging and spectroscopy of liquids using microfluidics in vacuum

This review offers a succinct overview of the development of a vacuum-compatible microfluidic reactor system for analysis at the liquid vacuum interface (SALVI), and its diverse applications in in situ, in vivo, and in operando imaging of liquid surfaces as well as the air-liquid (a-l), liquid-liquid (l-l), and solid-liquid (s-l) interfaces in the past decade. SALVI is one of the first microfluidics-based reactors that has enabled direct analysis of volatile liquids in vacuum surface tools such as scanning electron microscopy (SEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Its integration into ambient and vacuum spectroscopy and microscopy is illustrated. Several applications are highlighted including (1) imaging nanoparticles in liquid using in situ SEM; (2) mapping the evolving l-l interface using in situ x-ray absorption spectroscopy and ToF-SIMS; (3) following complex a-l interfacial oxidation reaction products using in situ ToF-SIMS; (4) capturing biological interfaces of cells and microbes via in vivo multimodal and correlative imaging; and (5) monitoring the dynamic solid electrode and liquid electrolyte interface using in operando molecular imaging. Finally, outlook and recommendations are presented. Besides showing the holistic information volume obtained by real-time multiplexed imaging, this review intends to convey the importance of tool development in revolutionizing surface and interface analysis using vacuum platforms previously limited to solid surfaces. Microfluidics is manifested to be not limited to ambient conditions in many examples in this review. Moreover, fundamental interfacial phenomena underpinning mass and charge transfer can now be pursued in real time via innovated chemical imaging and spectroscopy.

42 ENGINEERING↗

Comparison of EBSD, DIC, AFM, and ECCI for active slip system identification in deformed Ti-7Al

The use of SEM-DIC, AFM, ECCI, and HR-EBSD to characterize slip-system activity was assessed on the same material volume of Ti-7Al. This study presents a robust comparison of the various methods for the first time, including an assessment of their advantages and disadvantages, and how they can be used effectively in a complementary fashion. The analysis of the different approaches was carried out in a blind, round-robin manner at three different universities. A Ti-7Al specimen was deformed in uniaxial tension to approximately 3% axial strain, and the active slip systems were independently identified using (i) trace analysis; (ii) in-SEM digital image correlation, (iii) observations of residual dislocations from ECCI, and (iv) long-range rotation gradients through HR-EBSD, with consistent trace identification in all cases. Displacement data from AFM was used to augment SEM-DIC displacement data by providing complementary out-of-plane displacement information. Furthermore, short-range dislocation gradients (measured by DIC) provided insight into the residual geometrically necessary dislocation (GND) content, and was consistent with the GND content extracted from EBSD data and ECCI images, confirming the presence of residual GNDs on the dominant slip systems resulting in visible slip bands. Furthermore, these approaches can be used in tandem to provide multi-modal information on slip band identification, strain and orientation gradients, out-of-plane displacements, and the presence of GNDs and SSDs, all of which can be used to inform and validate the development of dislocation-based crystal plasticity and strain gradient models.

36 MATERIALS SCIENCE↗

Graphene Electric Field Sensor Enables Single Shot Label-Free Imaging of Bioelectric Potentials

The measurement of electrical activity across systems of excitable cells underlies current progress in neuroscience, cardiac pharmacology, and neurotechnology. However, bioelectricity spans orders of magnitude in intensity, space, and time, posing substantial technological challenges. The development of methods permitting network-scale recordings with high spatial resolution remains key to studies of electrogenic cells, emergent networks, and bioelectric computation. Here, for this work, we demonstrate single-shot and label-free imaging of extracellular potentials with high resolution across a wide field-of-view. The critically coupled waveguide-amplified graphene electric field (CAGE) sensor leverages the field-sensitive optical transitions in graphene to convert electric potentials into the optical regime. As a proof-of-concept, we use the CAGE sensor to detect native electrical activity from cardiac action potentials with tens-of-microns resolution, simultaneously map the propagation of these potentials at tissue-scale, and monitor their modification by pharmacological agents. This platform is robust, scalable, and compatible with existing microscopy techniques for multimodal correlative imaging.

47 OTHER INSTRUMENTATION↗

Dynamic fracture of glass fiber-reinforced ductile polymer matrix composites and loading rate effect

Here, the dynamic fracture of S-2 glass fiber-reinforced polymer matrix composites (FRPMCs) was investigated in this study. The matrix ductility was improved by a recently developed network topology modification technique via mixing partially reacted substructures (mPRS). The composite material was manufactured and characterized by micro-CT scanning and scanning electron microscopy (SEM). Dynamic single-edge notched bending (d-SENB) experiments were performed on the composites by using a modified split-Hopkinson pressure bar. Each specimen’s fracture process was visualized by ultrafast X-ray imaging. Such in-situ radiography enabled identifying the damage initiation below 50-micron scale and inspecting its propagation through the internal structures of opaque composites, thereby accurately quantifying the composites’ mechanical properties. Furthermore, the identical d-SENB experiments were designed and the digital image correlation (DIC) was employed to monitor the stress wave propagation on the composite specimens. The force and deflection measurements were modified and correlated to the physical damage processes. Besides, quasi-static SENB experiments were conducted to identify the loading rate effects on the composites’ fracture behaviors. The force and deflection history, bending stiffness, energy dissipation, and fracture toughness at different loading rates were quantified and compared. Finally, post-fracture analysis by micro-CT scanning and SEM provided physical observations on the variation of the fracture morphology by different loading rates.

42 ENGINEERING↗

Full-field quantitative visualization of shock-driven pore collapse and failure modes in PMMA

The dynamic collapse of pores under shock loading is thought to be directly related to hot spot generation and material failure, which is critical to the performance of porous energetic and structural materials. However, the shock compression response of porous materials at the local, individual pore scale is not well understood. This study examines, quantitatively, the collapse phenomenon of a single spherical void in PMMA at shock stresses ranging from 0.4 to 1.0 GPa. Using a newly developed internal digital image correlation technique in conjunction with plate impact experiments, full-field quantitative deformation measurements are conducted in the material surrounding the collapsing pore for the first time. The experimental results reveal two failure mode transitions as shock stress is increased: (i) the first in situ evidence of shear localization via adiabatic shear banding and (ii) dynamic fracture initiation at the pore surface. Numerical simulations using thermo-viscoplastic dynamic finite element analysis provide insights into the formation of adiabatic shear bands (ASBs) and stresses at which failure mode transitions occur. Further numerical and theoretical modeling indicates the dynamic fracture to occur along the weakened material inside an adiabatic shear band. Finally, analysis of the evolution of pore asymmetry and models for ASB spacing elucidate the mechanisms for the shear band initiation sites, and elastostatic theory explains the experimentally observed ASB and fracture paths based on the directions of maximum shear.

42 ENGINEERING↗

The Toughness of Interlocking Metasurfaces

Interlocking metasurfaces (ILMs) are arrays of autogenous latching unit cells patterned across a surface. These create structural joints similar to bioinspired suture joints but patterned over a 2D surface rather than a 1D seam. This enables ILMs to be an alternative to conventional joining technologies such as bolts, welds, and adhesives. However, compared to conventional joining methods, relatively little is known of the engineering considerations for designing structural ILMs. Herein, the interfacial toughness of an archetypal ILM is examined for the first time. Under the conditions studied here, the ILM is substantially tougher than the material from which it is made, in this case, exhibiting up to a 50% increase in interfacial crack initiation energy over the solid base material, a photocured 3D‐printed polymer. Through experimental tests using in‐situ digital image correlation along with complementary computational analyses, the mechanism of toughening in the ILM structure and the origins of toughness anisotropy are revealed. The increase in toughness is associated with cross‐cell interactions, that is, load‐sharing across unit cells, which give rise to a finite process zone length with different effective material properties. In this way, ILM toughening is analogous to crack blunting in ductile materials or fiber bridging in composites; yet here, the ILM is composed of a single‐phase base material and so the architected toughening is geometric in nature and hence amenable to future topological optimization.

fracture↗

The Role of Transition Metals on Chemo-Mechanical Instabilities in Prussian Blue Analogues For K-Ion Batteries: The Case Study on KNHCF Versus KMHCF

Prussian blue analogues (PBAs) cathodes can host diverse monovalent and multivalent metal ions due to their tunable structure. However, their electrochemical performance suffers from poor cycle life associated with chemo-mechanical instabilities. This study investigates the driving forces behind chemo-mechanical instabilities in Ni- and Mn-based PBAs cathodes for K-ion batteries by combining electrochemical analysis, digital image correlation, and spectroscopy techniques. Capacity retention in Ni-based PBA is 96% whereas it is 91.5% for Mn-based PBA after 100 cycles at C/5 rate. During charge, the potassium nickel hexacyanoferrate (KNHCF) electrode experiences a positive strain generation whereas the potassium manganese hexacyanoferrate (KMHCF) electrode undergoes initially positive strain generation followed by a reduction in strains at a higher state of charge. Overall, both cathodes undergo similar reversible electrochemical strains in each charge–discharge cycle. There is ~0.80% irreversible strain generation in both cathodes after 5 cycles. XPS studies indicated richer organic layer compounds in the cathode-electrolyte interface (CEI) layer formed on KMHCF cathodes compared to the KNHCF ones. Faster capacity fades in Mn-based PBA, compared to Ni-based ones, is attributed to the formation of richer organic compounds in CEI layers, rather than mechanical deformations. In conclusion, understanding the driving forces behind instabilities provides a guideline to develop material-based strategies for better electrochemical performance.

25 ENERGY STORAGE↗