Search NASA⌕ Search

SEARCH · Search NASA

Results for “cost sensitivity analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Energy and cost savings results for advanced technology systems from the Cogeneration Technology Alternatives Study /CTAS/

The Cogeneration Technology Alternatives Study (CTAS), a program undertaken to identify the most attractive advanced energy conversion systems for industrial cogeneration applications in the 1985-2000 time period, is described, and preliminary results are presented. Two cogeneration options are included in the analysis: a topping application, in which fuel is input to the energy conversion system which generates electricity and waste heat from the conversion system is used to provide heat to the process, and a bottoming application, in which fuel is burned to provide high temperature process heat and waste heat from the process is used as thermal input to the energy conversion system which generates energy. Steam turbines, open and closed cycle gas turbines, combined cycles, diesel engines, Stirling engines, phosphoric acid and molten carbonate fuel cells and thermionics are examined. Expected plant level energy savings, annual energy cost savings, and other results of the economic analysis are given, and the sensitivity of these results to the assumptions concerning fuel prices, price of purchased electricity and the potential effects of regional energy use characteristics is discussed.

Sagerman, G. D.↗

Sensitivity analysis of design parameters in RowWise borehole layout for ground heat exchangers

Ground source heat pump systems offer a promising pathway toward energy-efficient building heating and cooling. The performance and cost-effectiveness of these systems heavily depend on the design of the ground heat exchanger (GHE), particularly the spatial placement of boreholes used in large commercial buildings. Among various borefield layout strategies, the RowWise approach generates and optimizes borehole configurations within irregular polygonal land boundaries, providing land-use efficiency and installation flexibility. While multiple geometric design parameters constrain the RowWise layout, their influence on the system thermal performance and total drilling requirements remains unclear. Thus, this study presents a sensitivity analysis of key design parameters influencing the RowWise layout of vertical borehole GHEs, including the perimeter spacing ratio, borehole spacing, borehole field rotation angle, and borehole length. GHEDesigner and Ray Tune are employed to generate and assess different RowWise configurations. A series of parametric simulations was conducted to quantify the impact of each parameter on geometric distribution, economic cost, and computational speed. The results provide critical insights into the sensitivity and relative importance of different design parameters of RowWise method, offering practical guidance for designers aiming to optimize GHE layouts by balancing thermal efficiency, land constraints, and economic feasibility.

Xu, Dikai [Purdue University]↗

Analysis of the cost, schedule, and risk for Lynx mirror assembly production

This paper analyzes a recently published model for Lynx Mirror Assembly production duration, to understand the sensitivity of duration to various factors. The factors considered are finite process yield, knowledge of the individual process times and finite server reliability. In all of these cases, closed form estimates are given along with numerical examples. This initial analysis indicates that accurate and precise knowledge of the process times is fundamental to making an accurate prediction of schedule duration. Analysis of the failure of any given server is also explained and can be used as the basis of a rational sparing policy.

Jonathan W. Arenberg↗

The value of in-reservoir energy storage for flexible dispatch of geothermal power

Geothermal systems making use of advanced drilling and well stimulation techniques have the potential to provide tens to hundreds of gigawatts of clean electricity generation in the United States by 2050. With near-zero variable costs, geothermal plants have traditionally been envisioned as providing “baseload” power, generating at their maximum rated output at all times. However, as variable renewable energy sources (VREs) see greater deployment in energy markets, baseload power is becoming increasingly less competitive relative to flexible, dispatchable generation and energy storage. Herein we conduct an analysis of the potential for future geothermal plants to provide both of these services, taking advantage of the natural properties of confined, engineered geothermal reservoirs to store energy in the form of accumulated, pressurized geofluid and provide flexible load-following generation. We develop a linear optimization model based on multi-physics reservoir simulations that captures the transient pressure and flow behaviors within a confined, engineered geothermal reservoir. We then optimize the investment decisions and hourly operations of a power plant exploiting such a reservoir against a set of historical and modeled future electricity price series. Further, we find that operational flexibility and in-reservoir energy storage can significantly enhance the value of geothermal plants in markets with high VRE penetration, with energy value improvements of up to 60% relative to conventional baseload plants operating under identical conditions. Across a range of realistic subsurface and operational conditions, our modeling demonstrates that confined, engineered geothermal reservoirs can provide large and effectively free energy storage capacity, with round-trip storage efficiencies comparable to those of leading grid-scale energy storage technologies. Optimized operational strategies indicate that flexible geothermal plants can provide both short- and long-duration energy storage, prioritizing output during periods of high electricity prices. Sensitivity analysis assesses the variation in outcomes across a range of subsurface conditions and cost scenarios.

15 GEOTHERMAL ENERGY↗

Probabilistic Analysis of Ground-Holding Strategies

The Ground-Holding Policy Problem (GHPP) has become a matter of great interest in recent years because of the high cost incurred by aircraft suffering from delays. Ground-holding keeps a flight on the ground at the departure airport if it is known it will be unable to land at the arrival airport. The GBPP is determining how many flights should be held on the ground before take-off and for how long, in order to minimize the cost of delays. When the uncertainty associated with airport landing capacity is considered, the GHPP becomes complicated. A decision support system that incorporates this uncertainty, solves the GHPP quickly, and gives good results would be of great help to air traffic management. The purpose of this thesis is to modify and analyze a probabilistic ground-holding algorithm by applying it to two common cases of capacity reduction. A graphical user interface was developed and sensitivity analysis was done on the algorithm, in order to see how it may be implemented in practice. The sensitivity analysis showed the algorithm was very sensitive to the number of probabilistic capacity scenarios used and to the cost ratio of air delay to ground delay. The algorithm was not particularly sensitive to the number of periods that the time horizon was divided into. In terms of cost savings, a ground-holding policy was the most beneficial when demand greatly exceeded airport capacity. When compared to other air traffic flow strategies, the ground-holding algorithm performed the best and was the most consistent under various situations. The algorithm can solve large problems quickly and efficiently on a personal computer.

Sheel, Minakshi↗

A computationally-efficient method for flamelet calculations

A new open-source code for the simulation of the diffusion flamelet equations is proposed. Emphasis is placed on using an approximate Jacobian to reduce the computational cost of the matrix operations. Performance of the proposed solvers is tested by performing flamelet calculations with kinetic mechanisms of varying sizes. For the unity Lewis number equations, the present iterative Newton solver using an approximate Jacobian greatly outperforms direct Newton solvers using exact Jacobians. The computation cost scales linearly with the number of species, leading to a reduction in solution times by two orders of magnitude for mechanisms containing thousands of species. The applicability of the Jacobian approximations to the solution of the non-unity Lewis number flamelet equations is assessed. The approximations are generally inadequate to solve the full non-unity Lewis number equations but can be used in some applications depending on the balance of terms in the flamelet equations. As an example, the flamelet solver is applied to the study of sooting tendencies in laminar co-flow diffusion flames where modified non-unity Lewis number flamelet equations, previously shown to accurately reproduce experimentally-measured Yield Sooting Indices (YSI), are solved. Here, the accelerated flamelet solver is well suited for sensitivity analysis and uncertainty quantification with large detailed kinetic mechanisms, tasks for which the computational cost was previously prohibitive.

42 ENGINEERING↗

The impact of climate on solvent-based direct air capture systems

Direct air capture (DAC) is increasingly seen as a critical technology to reach mid-century net-zero targets and limit climate change to well below 2 °C. While the commercialization of DAC technologies is being pursued by numerous companies, there remains remarkably little information on their performance under “real-world” conditions. In this paper, for the first time, we investigate the influence of temperature and relative humidity of air on the CO 2 capture rate at the air contactor, overall energy requirement, CO 2 capture efficiency, and levelized cost of liquid-solvent based DAC systems. We observe that the overall energy demand decreases from 11.1 to 8.3 GJ/tCO 2 as the CO 2 capture rate increases from 40 to 85 % and that high capture rates can only be achieved in hot and humid climate conditions. We observe that a CO 2 capture rate of 75 % is only possible above 17 °C and 90 % relative humidity, and this drops dramatically at lower temperatures. It is also observed that water evaporation in the air contactor is highest at dry and low relative humidity, as expected. The sensitivity analysis showed that CO 2 capture efficiency is relatively insensitive to climate conditions for the liquid-solvent based DAC plant. Lastly, the levelized cost of natural gas standalone scenario varies from $240/tCO 2 to $409/tCO 2 , and this is more sensitive to temperature than relative humidity. The levelized cost of the natural gas stand-alone case is between 7 % and 10 % lower than that of an electric grid-connected case across all climate conditions.

54 ENVIRONMENTAL SCIENCES↗

Hazard and risk analysis framework for nuclear power plant–based integrated energy systems

Employing integrated energy systems (IESs) with nuclear power plants (NPPs) can improve NPP utilization by leveraging dedicated thermal and electric power delivery, but it may also increase operational safety risks. This paper presents a framework to identify and quantify hazards and risks for such IESs. The framework combines accidentology to review past industrial accidents with failure modes and effects analysis (FMEA) to identify potential future incidents. Hydrogen explosion and toxic chemical release hazards are of particular concern. Explosion consequences are quantified using the Bauwens-Dorofeev (Bauwens) and trinitrotoluene equivalent mass (TNT-EM) methods, while chemical release consequences are computed using the Gaussian atmospheric dispersion method. Operational disturbances from direct electrical and thermal integration that may affect NPP safety are modeled using probabilistic risk analysis (PRA). Hazards and risks are then evaluated for regulatory compliance. The framework is applied to IESs comprising pressurized or boiling water reactors supplying three levels of thermal and electrical power to industrial customers. Case studies include high-temperature steam electrolysis hydrogen plants of varying capacities and a synthetic fuel production plant. Sensitivity analysis examines piping component failures in the PRA model as a precursor to cost estimation for thermal extraction line design. Additionally, Fussel-Vessely (FV) and risk increase importance (RII) measures identify risk-informed design improvements for the thermal extraction system. FMEA highlights hazards such as loss of offsite power, prompt loss of electrical load, loss of thermal output, and immediate steam diversion, in addition to hydrogen explosions and toxic chemical releases. Both Bauwens and TNT-EM methods suggest maintaining several hundred meters of separation between the NPP and hydrogen facility to mitigate explosion risks. PRA results show a maximum initiating event frequency increase of 1.15% and an overall risk increase of 0.28%. Importance measure analysis identifies upstream pipe leak isolation components as critical. Evaluating the results against safety regulations, it is concluded that hazards and risks can be managed to comply with regulations through risk-informed thermal and electrical connection designs, component selection, maintenance programs, and safe separation distances between NPPs and integrated industrial facilities.

08 - HYDROGEN↗

Impact of the numerical solution approach of a plant hydrodynamic model (v0.1) on vegetation dynamics

Abstract. Numerous plant hydrodynamic models have started to be implemented in vegetation dynamics models, reflecting the central role of plant hydraulic traits in driving water, energy, and carbon cycles, as well as plant adaptation to climate change. Different numerical approximations of the governing equations of the hydrodynamic models have been documented, but the numerical accuracy of these models and its subsequent effects on the simulated vegetation function and dynamics have rarely been evaluated. Using different numerical solution methods (including implicit and explicit approaches) and vertical discrete grid resolutions, we evaluated the numerical performance of a plant hydrodynamic module in the Functionally Assembled Terrestrial Ecosystem Simulator (FATES-HYDRO version 0.1) based on single-point and global simulations. Our simulation results showed that when near-surface vertical grid spacing is coarsened (grid size >10 cm), the model significantly overestimates aboveground biomass (AGB) in most of the temperate forest locations and underestimates AGB in the boreal forest locations, as compared to a simulation with finer vertical grid spacing. Grid coarsening has a small effect on AGB in the tropical zones of Asia and South America. In particular, coarse surface grid resolution should not be used when there are large and prolonged water content differences among soil layers at depths due to long dry-season duration and/or well-drained soil or when soil evaporation is a dominant fraction of evapotranspiration. Similarly, coarse surface grid resolution should not be used when there is lithologic discontinuity along the soil depth. This information is useful for uncertainty quantification, sensitivity analysis, or the training of surrogate models to design the simulations when computational cost limits the use of ensemble simulations.

54 ENVIRONMENTAL SCIENCES↗

Electric Propulsion Upper-Stage for Launch Vehicle Capability Enhancement

The NASA In-Space Propulsion Technology Project Office initiated a preliminary study to evaluate the performance benefits of a solar electric propulsion (SEP) upper-stage with existing and near-term small launch vehicles. The analysis included circular and elliptical Low Earth Orbit (LEO) to Geosynchronous Earth Orbit (GEO) transfers, and LEO to Low Lunar Orbit (LLO) applications. SEP subsystem options included state-of-the-art and near-term solar arrays and electric thrusters. In-depth evaluations of the Aerojet BPT-4000 Hall thruster and NEXT gridded ion engine were conducted to compare performance, cost and revenue potential. Preliminary results indicate that Hall thruster technology is favored for low-cost, low power SEP stages, while gridded-ion engines are favored for higher power SEP systems unfettered by transfer time constraints. A low-cost point design is presented that details one possible stage configuration and outlines system limitations, in particular fairing volume constraints. The results demonstrate mission enhancements to large and medium class launch vehicles, and mission enabling performance when SEP system upper stages are mounted to low-cost launchers such as the Minotaur and Falcon 1. Study results indicate the potential use of SEP upper stages to double GEO payload mass capability and to possibly enable launch on demand capability for GEO assets. Transition from government to commercial applications, with associated cost/benefit analysis, has also been assessed. The sensitivity of system performance to specific impulse, array power, thruster size, and component costs are also discussed.

Kemp, Gregory E.↗

Examination of Factors Affecting the Cost and Performance of a Natural Gas Combined Cycle Equipped with Carbon Dioxide Capture

The purpose of this Technical Note is to report the findings of an examination of the effect of plausible deviations in select study assumptions on the reported cost and performance estimates for a power plant case drawn from NETL’s “Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity” (known as the Fossil Energy Baseline). An F-Class NGCC power plant equipped with state-of-the-art, solvent-based, post-combustion carbon dioxide (CO2) capture (95 percent carbon capture rate)—designated as Case B31B.95—was selected for this work. This sensitivity analysis provides insight into the effects of parameter variations within and across selected categories—ambient conditions, construction cost, natural gas (NG) price, capacity factor, and finance—on the plant performance and capital and operating and maintenance (O&M) costs, and the subsequent impact on common figures of merit.

20 FOSSIL-FUELED POWER PLANTS↗

Making coal relevant for small scale applications: Modular gasification for syngas/engine CHP applications in challenging environments

Small-scale coal gasification technology, coupled to a reciprocating engine generator, has the potential for making coal a cost competitive resource for meeting the flexible energy needs and resiliency requirements of utilities across the United States. To maintain grid stability and reliability, electrical generation must be regulated to match the load at the proper voltage and frequency. With the expansion of intermittent sources into the grid, such as wind and solar, frequency and voltage regulation become increasingly important and challenging. This work presents the results of a Front End Engineering Design (FEED) effort to detail the engineering and preliminary economics of a small-scale, air blown, fixed-bed gasification process, operating at near-atmospheric pressure, with gas cleanup to provide syngas and pyrolysis liquid fuels for use in reciprocating engine generators for combined heat and power at the University of Alaska Fairbanks. A very detailed assessment of capital and operating costs allows the evaluation of a levelized cost of electricity of 208.06 $/MWh, which can be reduced through the selling of by-products (steam for heating purposes and pyrolysis liquids to be used for power generation in an existing diesel engine). Here, a combined sensitivity analysis, based on the Monte Carlo approach, has been carried out to evaluate the effects of the uncertainties (capital and operating costs and plant annual availability) on the LCOE.

01 COAL, LIGNITE, AND PEAT↗

Dual-loop Solvent-based CCS for Net Negative CO 2 Emissions with Lower Cost

This final technical report details the successful design, construction, and operational validation of an innovative dual-loop CO 2 capture technology designed to achieve deep decarbonization (>99%) from Natural Gas Combined Cycle (NGCC) power plants that results in the electricity with carbon intensity of approximate 42 kg CO 2 -eq/MWh, less than the electricity produced by solar PV. The integrated process couples a primary aqueous solvent (in this project, a water lean solvent – WLS) absorption loop for bulk CO 2 removal with a secondary potassium hydroxide (KOH) polishing loop featuring electrochemical regeneration. This architecture leverages the higher exergy efficiency of the primary loop while utilizing the fastest kinetic of the secondary loop to capture dilute residual CO 2 , achieving an overall capture rate of 99.9% and co-producing pure hydrogen after moisture being condensed and dehydrated. Technical feasibility was established through a comprehensive 2,000-hour experimental campaign on a bench-scale fully-integrated unit (using 4” absorber and 4” stripper) with the feeding flue gas flowrate in the range of 8-20 cfm, confirming the attainment of Technology Readiness Level (TRL) 4. The project executed extensive parametric testing followed by 1,000 hours of continuous steady-state testing, demonstrating exceptional process stability with the electrochemical regenerator exhibiting less than a 10% reduction in electrical conductivity over the duration of the campaign. Operational characterization gathering on the bench unit revealed distinct energy profiles for the hybrid system: the primary loop required approximately 280 kJ mol -1 for bulk removal, while the polishing loop required approximately 1,600 kJ mol -1 specifically when reducing dilute CO 2 concentrations from ~740 ppm down to <50 ppm. (Please note those energy values/numbers can only be viewed as relative relationship and should not be extrapolated as absolute values required for CO 2 capture). Furthermore, dynamic testing validated the system’s flexibility for utility applications, demonstrating a rapid process response time of <30 minutes to changes in flue gas flowrate. Emission monitoring confirmed that the dual-loop architecture effectively mitigates solvent losses, utilizing a water wash to remove entrained aerosols to <1 ppm. The Techno-Economic Analysis (TEA) indicates a cost of capture of $\$$59.3/tonne and a Levelized Cost of Electricity (LCOE) of 71.7 $\$$/MWh at the overall capture efficiency of 99.8% of total carbon in the flue gas stream, with sensitivity analysis identifying an economic optimum when the primary loop captures 97% of the total CO 2 . A Life Cycle Assessment (LCA) confirms the technology’s potential for net-negative emissions, determining a Global Warming Potential (GWP) of 52 kg CO 2 -eq/MWh—significantly lower than the baseline—which further decreases to 42 kg CO 2 -eq/MWh when crediting the displacement of conventional hydrogen production.

03 NATURAL GAS↗

Pilot-Scale Testing of an Integrated Circuit for the Extraction of Rare Earth Minerals and Elements from Coal and Coal Byproducts Using Advanced Separation Technologies

The primary objective of this project was to develop and demonstrate an integrated pilot-scale circuitry for recovering high-value rare earth elements (REEs) from coal and coal byproducts. The target performance was to produce a mixed REE product with content of at least two percent by weight on a dry mass basis in a cost-effective and environmentally benign manner. During the first nine months of the project period (Phase 2 Budget Period 2), pilot plant construction was completed including all field site startup activities such as permitting, engineering design, procurement/bidding, unit fabrication, site construction, equipment installation, module assembly, safety training, and circuit shakedown. During the remaining 21 months of project period (Phase 2 Budget Period 3), detailed field-testing activities were performed including feedstock sample collection and preparation, exploratory testing, circuit modification, detailed parametric study, and performance optimization. A detailed techno-economic analysis was performed based on the pilot plant testing findings which provided various scenarios for REE production. The project successfully accomplished the proposed target performance by producing mixed rare earth oxide (REO) with greater than 90% purity by weight in a continuous pilot scale operation from two distinctly different coarse refuse materials (i.e., West Kentucky No. 13 and Fire Clay coal seams), and at least three secondary sources (i.e., heap leach process and naturally formed acid mine drainage system). Project partners included the University of Kentucky, Virginia Tech, West Virginia University, Alliance Coal, Blackhawk Mining, Mineral Refining Company, and Mineral Separation Technologies. The pilot scale test facility was constructed at a former mining complex owned by Alliance Natural Resource Partners (Alliance Coal). The site was rehabilitated to accommodate the equipment installation, construction and fabrication, electrical power requirement, water line management and containment. The process units constructed and installed included X-ray sorting unit, crushing and grinding unit, physical separation unit, acid leaching unit, solvent extraction unit, and wastewater management unit. A rare earth mineral concentration unit was constructed as a standalone unit for flexible operation. A detailed environmental assessment and control plan was carried out to identify and quantify any potential impacts of the pilot-scale processing circuitry on the human and eco-system health and well-being. Corresponding mitigation strategies and control measures were provided. A conceptual flowsheet was developed to effectively remove thorium and uranium from high purity rare earth oxide mix or any potential radionuclide enriched stream. The two distinct feedstock materials were secured from the Blackhawk Mining Complex in eastern Kentucky where the Fire Clay (Hazard No. 4) seam is processed. The West Kentucky No. 13 (Baker) coarse refuse material was collected from an active process stream at an Alliance coal preparation plant located in western Kentucky. Characterization analysis indicated that both of feed materials generated from the two sources contained >300 ppm of TREEs on a dry whole mass basis which met the requirements for a qualified feed stock. The two feedstocks were further upgraded using a dual x-ray sorter to prepare the feed material for hydrometallurgical circuit. Thermal treatment on feed material prior to leaching was found to: 1) improve the leaching recovery of REEs, 2) increase the leaching kinetics, and 3) allow the leaching reaction to occur at lower acidity. Roasting at 600°C was selected as the pre-treatment condition for both West Kentucky No. 13 and Fire Clay coarse refuse material. Over 40% of leaching recovery was achieved by roasting West Kentucky No. 13 material having a top particle size of 3 mm in the pilot scale operation using 1.2M sulfuric acid leaching at 75OC. Initial pilot scale testing involved continuous operation of the pilot plant for 94 hours. The leaching unit was operated at solid-to-liquid ratio of 1 to 10 (w/v) using 0.5M sulfuric acid solution at a temperature of 75°C. The continuous solvent extraction circuit utilized rougher and cleaner units with DEHPA and TBP as the extractants. An innovative stripping circuit was developed to accumulate the REE concentration in the stripping solution to a level above 600 ppm. A bleed stream from the recycled strip solution was treated using oxalic acid precipitation which produced a high grade rare earth oxalate. The oxalate product was roasted to remove the oxalate which produced a rare earth oxide product having a purity greater 90%. Due to high concentrations of contaminant ions in the pregnant leach solution (PLS), a modified flowsheet was developed that involved pre-concentration of the REEs using multiple stages of precipitation and redissolution. The advantage of this process was improved removal of contamination before the downstream purification process and a significant cost reduction relative to the circuit that utilized the solvent extraction process. The modified circuitry included processes involving leaching, multistage precipitation, redissolution, and oxalate precipitation followed by roasting of the oxalate product. The circuit produced a mixed REO that was 92.96% pure from the initial test. A detailed parametric test plan was carried out which involved varying key parameters including solids feed rate, acid flowrate, acid concentration, multistage precipitation pH, redissolution pH, oxalate precipitation dosage and pH. The response variables included REE recovery, contaminant recovery, REO product grade and overall chemical consumption. Test results indicated that the acid-to-solid ratio is the key parameter to leaching efficiency as performance deteriorated with an increase in solids concentration. The optimal pH determined for REE precipitation and redissolution was 6.5 and 2.5, respectively. Additional tests were conducted to further improve the flowsheet. Recirculating a portion of the PLS to the feed of the leach tanks improved the leaching performance by lowering the pH of the leaching system and reducing the contamination recovery by shortening the residence time. Moreover, the removal of Al prior to REE precipitation significantly reduced the oxalic acid consumption in the oxalate precipitation circuit. The modified circuit produced over 90% grade REO by weight from both West Kentucky No. 13 and Fire Clay coarse refuse material in pilot scale continuous test programs. A case analysis model was developed to project the REE and major contaminants concentration in each PLS stream based on the leaching condition, pH cut point, and oxalic acid dosage. A correlation was established using empirical and semi-empirical models. Using the models, chemical consumption required for each stage was predicted based on the projected performance of the hydrometallurgy circuit. After identifying the optimum conditions, validation tests were carried out for the treatment of both West Kentucky No. 13 and Fire Clay coarse refuse materials in the pilot plant. The actual circuit performance and chemical consumptions were very close to the model predictions. Other than the two coarse refuse sources, several secondary feedstocks were also tested in the pilot plant facility. A “heap leach” system was constructed using the coarse refuse material generated from cleaning the West Kentucky No. 13 seam coal. Using the two stage SX rougher and cleaner circuit, a concentrate with a grade >90% REO was produced while recovering >97% of the REEs from the heap leach PLS. Naturally generated acid mine drainage (AMD) from West Kentucky No.13 mine was processed using the multistage precipitation circuit in the pilot plant in a test conducted for a period of 32 hours. The final grade of the mix RE oxide produced from the AMD was 90.84% with an overall circuit recovery of 64%. The primary source of REE was the selective precipitation steps involving iron and aluminum rejection. The hydrophobic-hydrophilic separation (HHS) process was proven to effectively recover coal from fine waste materials. For REM recovery, the HHS process was able to produce concentrates at grades of approximately 1.8% REE on an ash basis; however, recovery values were typically low, <10%, under the optimal conditions determined in the laboratory-scale testing. Staged testing of the pilot-scale HHS process for coal recovery and semi-continuous laboratory testing for REM testing showed that a total concentration ratio of more than 15x was observed for the REM recovery process. A circuit simulation package was developed for REE extraction and purification using a spreadsheet-based platform (Microsoft Excel). The REESim circuit simulation package is configured to track the mass and volume flows of components passing through a series of unit operations specified and configured by the user. The mass rates can then be utilized by the user to determine important performance indicators such as product mass yields, concentrate purity levels, element-by-element recoveries, and so forth. The techno-economic analysis showed that the roasting and leaching operations were the most expensive capital items, each contributing approximately 30% to the total capital cost. One notable contributor to the high production costs was the low REE recovery observed in the pilot scale trials. The product basket price was shown to have a strong influence on the economic viability of the scenarios, with the scandium price being the most significant influencer. Operating cost was shown to be extremely sensitive to REE recovery, REE feed grade, and leaching acid consumption. An analysis of ten different scenarios for a 500 t/h commercial operation revealed that three were economically favorable, producing internal rates of return varying from 27.7% to 33.1% and payback periods of 4 to 5 years. The project successfully developed and demonstrated a process to recover REEs from coal and coal byproducts in a pilot-plant operation which consistently produced over 90% grade REO mix from varies types of feedstocks. Commercialization analysis showed that the technology readiness level successfully achieved TRL 6 at the end of the project and demonstrated the need and the potential for scaling the process to further advance the technologies toward the goal of providing a domestic supply of REEs at a commercial scale.

01 COAL, LIGNITE, AND PEAT↗

Optimal Pathways from Alternative Carbon Feedstocks to Organic Commodity Chemicals

The use of biogenic and waste feedstocks is a promising strategy to improve the chemical sector's supply chain resiliency and carbon intensity. To help inform research efforts that transform these feedstocks into industrial chemicals, we used a systematic analysis framework to consistently evaluate the economics and environmental impacts of >200 alternative production pathways for 51 organic commodity chemicals in the United States under an optimistic future scenario that reflects the potential upper bounds of process scalability, energy availability, and carbon uptake. Lower-impact and lower-cost alternative pathways were identified for all but three chemicals, with 75% using thermochemical routes and half leveraging existing manufacturing infrastructure. Scenario analysis shows that the ranking of these pathways for half of the assessed chemicals is particularly sensitive to carbon uptake assumptions and criteria prioritization (i.e., cost only, environmental impact only, or both), with changes in electricity grid mix, hydrogen source, and underlying mass and energy flow data proving less influential. Implementing alternative pathways for just 11 chemicals could support a transition to net-zero greenhouse gas emissions from chemical production by 2050, with 11% lower cost than business as usual, similar water requirements, quadrupled electricity demand, and the use of most available woody biomass. These findings provide an exploratory guide toward a future chemical industry that harnesses alternative feedstocks.

09 BIOMASS FUELS↗

Bipolar Membrane Electrodialyzers as Flexible Demand Response Resources: Co-Optimization of Cost Savings and Product Formation

Bipolar membrane electro dialyzers (BPMED) are widely used for chemical production and processing, including in the emerging ocean alkalinity enhancement (OAE) industry. In this paper, we explore the potential of BPMED devices as flexible electrochemical loads within power system operations. Using a multi-objective optimization framework, we evaluate BPMED operation across 24-hour and monthly horizons to examine how dispatch strategies respond to electricity price and grid conditions. Simulation results show that altering the relative weights of the choices in the objective function strongly shape the operating patterns, with cost-focused strategies that suppress the operation during peak prices. Furthermore, we propose alternative formulations that optimize operations to achieve both cost savings and alignment with periods of lower grid-side carbon intensity (CI), as low grid-side CI is key to maximize OAE efficiency. Additionally, a detailed sensitivity analysis highlights the importance of device properties, where low area-specific resistance (ASR) of membrane and high current efficiency (CE) are observed to jointly unlock cost-effective operation. However, even modest shunt efficiency losses are observed to erode performance and decrease system value. Importantly, the analysis demonstrates that BPMED can serve as a controllable and flexible demand response resource, shifting load to support multiple grid-side objectives, including (but not limited to) renewable integration, alleviate peak demand, and provide co-benefits for system reliability. These findings underscore BPMED’s dual role as a process technology and a grid-supporting asset, pointing to promising pathways for operational optimization of multiple objectives.

Bhattacharya, Saptarshi (ORCID:0000000308902060)↗

Data-Enabled Predictive Control for Building HVAC Systems

Model predictive control is widely used as a control technology for the computation of optimal control inputs of building heating, ventilating, and air conditioning (HVAC) systems. However, both the benefits and widespread adoption of model predictive control (MPC) are hindered by the effort of model creation, calibration, and accuracy of the predictions. In this paper, we apply the data-enabled predictive control (DeePC) algorithm for designing controls for building HVAC systems. The algorithm solely depends on input/output data from the system to predict future state trajectories without the need for system identification. The algorithm relies on the idea that a vector space of all input–output trajectories of a discrete-time linear time-invariant (LTI) system is spanned by time-shifts of a single measured trajectory, given the input signal is persistently exciting. Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated building modeled in EnergyPlus is a modified commercial large office prototype building served by an air handling unit-variable air volume HVAC system. Temperature setpoints of zones are used as control variables to minimize the HVAC energy cost of the building considering a time-of-use electricity rate structure. Furthermore, sensitivity analysis is conducted to gain insights into the effect of parameter tuning on DeePC performance. Simulation results are used to illustrate the performance of the algorithm and compare the algorithm with model-based MPC and occupancy-based setpoint controller. Overall, DeePC achieves similar performance compared to MPC for lower engineering effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spacecraft design sensitivity for a disaster warning satellite system

A disaster warning satellite (DWS) is described for warning the general public of impending natural catastrophes. The concept is responsive to NOAA requirements and maximizes the use of ATS-6 technology. Upon completion of concept development, the study was extended to establishing the sensitivity of the DWSS spacecraft power, weight, and cost to variations in both warning and conventional communications functions. The results of this sensitivity analysis are presented.

Maloy, J. E.↗