Search NASA⌕ Search

SEARCH · Search NASA

Results for “criticality safety evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Updates to the n+ 63,65 Cu RRR+URR Evaluations [Slides]

This work updates neutron reactions on 63,65 Cu. It also discusses the motivations of the research which is to correct deficiencies in benchmark performance since critical assembly configurations use Cu as a reflector. This presentation discusses the incorporation of URR parameters fit to 2017 63 Cu(n, γ) measurement by Weigand et al., as well as preliminary work on angular distributions and states that validation against copper-sensitive ICSBEP benchmarks is ongoing. The presentation concludes by stating that R -matrix analysis coupled to consistent average parameters used in the URR have been performed for 63,65 Cu isotopes, that future work will focus on the angular distributions, and that an analysis of additional data measured on natural Cu sample is in progress.

07 ISOTOPE AND RADIATION SOURCES↗

IER 498: Godiva-IV CAAS benchmark [Slides]

This presentation discusses the benchmark of the IER 498: Godiva-IV criticality accident alarm system (CAAS). It details the goal of the project which is to create a CAAS benchmark capability for Godiva-IV in order to create a shielding benchmark for NCSP software and data, to add geometrically diverse benchmark/benchmarks to the ICSBEP Handbook, to enable more precise measurements at NCERC, and to help assure CAAS performance is as-stated. It also states that work was completed on CED-1 in 2019 and that future work includes the completion of CED-2 in 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation and Validation of the n+ 63,65 Cu Cross Sections [Slides]

This presentation discusses the objective of the research which is to update n+ 63,65 Cu cross section evaluations with recently measured data to resolve discrepancies in benchmark performance. It also discusses the models used which are the R -matrix analysis and the analysis of angular distribution coefficients. Additionally, the validation methods that were used are discussed, including the Rez shielding benchmark and the ICSBEP criticality benchmarks. In conclusion, he n+ 63,65 Cu cross sections have been updated via R-matrix analysis up to 100 keV. An increased average capture cross section and the adoption of experimentally based Legendre coefficients lead to improved performance in reactivity benchmarks. In the fast region, the adoption of the JENDL-4.0 cross sections above 4.0 MeV improves the performance in shielding benchmarks. Ultimately, the n 63,65 Cu ENDF files will be submitted to ENDF/B-VIII.1.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

VALID Past, Present, and Future [Slides]

This presentation discusses the Verified, Archived Library of Inputs and Data (VALID) procedure which is managed per computational procedure under the overall SCALE quality assurance plan. The principle behind VALID is that two independent, qualified people prepare and review the model, while a dual, independent check acts as a primary barrier to prevent errors in the library. A final check by VALID QAC of procedural compliance is then performed. The future for VALID includes plans to add more experiments, a review for all ICSBEP cases containing Deuterium, ZEUS intermediate and fast spectrum evaluations, intermediate enrichment experiments, other cases of interest to sponsors, and mixed/intermediate spectrum experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FY21 Progress of the Oak Ridge Health Physics Research Reactor CAAS Benchmark Evaluation [Slides]

The FY21 version of the evaluation, focusing on element 57 dose at 3 meters, was presented at the ICSBEP Technical Review Group meeting in October 2021 and was not accepted for 2022 publication in the handbook. The main issue was identified and replacement of the element 57 neutron dose benchmark metric by neutron fluence (closer to what was measured) is required. A subgroup was formed, confident for the updated neutron fluence evaluation to be accepted in the ICSBEP handbook. The updated evaluation will be presented again at the 2022 ICSBEP TRG for publication in the 2023 handbook.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multi-group Examination of Nickel-Reflected HEU System [Slides]

Researchers noted an unusually large bias for 8-in. nickel reflected HEU sphere in HMF-003 between the 252- group library and the CE library in SCALE 6.2.4. The bias was investigated by reviewing reactions that $k_{eff}$ is sensitive to using TSUNAMI and collecting reaction rate data using tools within SCALE. For this system, bias is primarily due to the elastic scattering in nickel. Researchers compared new multigroup structures in SCALE 6.3. For this system, reduction in CE-to-MG bias seen in the 302-group and further improved in the 1597-group structure. When researchers compared ENDF/B-VIII.0 in SCALE 6.3, library showed improved results with new nickel evaluation. However, the MG-to-CE bias can still be large as large biases can occur in any system. This example highlights the importance of validating results with measured systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

140,142 Ce Neutron Cross Section Resolved Resonance Region Evaluation [Abstract]

A resolved resonance region evaluation of 140,142 Ce has been carried out by Oak Ridge National Laboratory. Requested by the US Nuclear Criticality Safety Program, this evaluation is based on recent high-resolution transmission and capture high-resolution measurements of nat Ce and 142 Ce conducted at JRC-GEEL at the Geel Linear Accelerator facility, as well as recently measured thermal constants available from the EXFOR database. Starting from the resonance parameters from the ENDF/B-VIII.0 library and following a preliminary R-matrix analysis, an updated set of resonance parameters and corresponding covariance information was derived by the fit of these experimental datasets using the Reich-Moore approximation of the R-matrix theory as implemented in the SAMMY code system. The resolved resonance region upper energy limit for 140 Ce was kept at 200 keV while the 142 Ce resonance region was extended from 13 to 26 keV. This new evaluation was found to be in good agreement not only with several integral quantities of interest to the reactor physics community, but also with the stellar Maxwellian-averaged cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

R-matrix Resolved Resonance Region Evaluation of 140,142 Ce

Oak Ridge National Laboratory completed the resolved resonance region (RRR) evaluation of the two most abundant cerium isotopes, 140 Ce (88.45%) and 142 Ce (11.11%), as requested by the US Nuclear Criticality Safety Program. These evaluations are based on recent high-resolution transmission and capture measurements performed on nat Ce and highly enriched 142 Ce samples at the JRC-Geel Linear Accelerator facility, as well as measured thermal constants available from the EXFOR database. Starting from the resonance parameters of the ENDF/B-VIII.0 library followed by a preliminary R-matrix analysis, an updated set of resonance parameters and corresponding covariance information were derived by fitting these measured data using the Reich–Moore approximation of the R -matrix theory, as implemented in the SAMMY code system. The 140 Ce RRR upper energy limit was kept at 200 keV, whereas the 142 Ce resonance region was extended from 13 to 26 keV. Updated statistical properties were obtained for the new evaluations and compared to those derived from the ENDF/B-VIII.0 nuclear data library. The new evaluation work improved some of the discrepancies found in previous work, such as the capture resonance integral and stellar Maxwellian-averaged cross sections. These integral quantities were mainly derived from the fit of the latest measured data, especially the neutron capture yield data for 142 Ce isotope.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Verification and validation testing and tools: comparison between MCNP code versions and nuclear data libraries [Slides]

This presentation discusses the primary goal of software testing which is to test the code for correctness. It also discusses the results for individual suites and the role of validation and verification also referred to in the presentation as V&V. In summation, the V&V framework enables easy comparison between calculations performed with different code versions and/or nuclear data libraries. This entire framework will be distributed with the upcoming MCNP6.3 release. V&V test suites shown and several that were not (Criticality, LAQGSM, Lockwood) will be distributed in the new framework.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast-Spectrum Critical Assemblies with a Pb-HEU Core Surrounded by a Copper Reflector

The Department of Energy invests tens of millions of dollars each year to develop the next generation of nuclear engineering modeling & simulation (M&S) tools. These M&S tools are used to analyze advanced reactor designs and the safety of current nuclear operations. As computers become more powerful, we are able to enhance resolution in our calculations. This improved resolution is taking us to a point where the limitations of simulation capability are in the quality of data, including our ability to quantify the uncertainty and sensitivity of the data. In order to accurately model systems of interest, the industry must improve key nuclear data measurements and our confidence of how well we understand the data. Thus, M&S tools need evaluated and quality-assured experimental data for validation purposes. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) compiles benchmark experiment data in a handbook that can be used by criticality safety engineers to validate computer codes and cross-section libraries at nuclear facilities. Both critical and subcritical experiments are included in the handbook. Figure 1 organizes all the benchmark evaluations that have been performed by the isotope of interest, in this case Pb, and the neutron energy within the system. Compared to other isotopes of interest for nuclear applications, there are few benchmark evaluations for Pb systems. This has caused the latest nuclear cross-section libraries to over/underestimate changes in the neutron population compared to experimental results. Therefore, this evaluation fills an important knowledge gap in benchmark evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmark Evaluation of one Dimensional Array of HEU Moderated and Reflected by Lucite [Poster]

Two critical experiments with HEU-Lucite were performed using the Planet Universal Critical Assembly Machine at Los Alamos National Laboratory in 2019. HEU foils were interleaved with Lucite in a column stack for moderation and reflection from the square Lucite plates. The evaluation of the experiments is presented. A Monte-Carlo (MCNP6) calculation model was developed for the determination of uncertainties and their effect on the multiplication factor. Experimental uncertainties were found to be low with the overall uncertainty in k eff approximately 240 pcm. The comparison of calculations with experimental data is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NDCS Group Meeting Work overview: NCSP Task ORNL IP&D-5 [Slides]

The presentation discusses the primary goal of the NCSP Task IP&D-5 which is to use available data from HPRR operation to create a benchmark report for inclusion in the ICSBEP, as a Criticality Accident Alarm System (CAAS) shielding benchmark. The presentation elaborates on the HPRR operation and how it relates to the KENO VI model, sulfur pellets measurements, and calculation methodology between KENO and MAVRIC FW-CADIS. The presentation concludes by stating that some work is still needed to evaluate uncertainties and to explain the discrepancy computation/experiment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

R -Matrix Analysis and Statistical Properties of Dysprosium Isotopes in the Neutron Energy Ranges Up To A Few Kev

In support of the Nuclear Criticality Safety Program, a set of evaluated resonance parameters was generated for seven dysprosium isotopes in the neutron energy range from thermal up to a few keV. The evaluation methodology used the Reich-Moore approximation to fit, with the R-matrix code SAMMY, the high-resolution capture and transmission measurements on natural and enriched samples recently performed at the Rensselaer Polytechnic Institute Gaerttner LINear ACcelerator facility. Additional transmission data measured on enriched samples by Liou at the Columbia University Nevis synchrocyclotron in the mid-seventies were used to gauge the neutron widths above 15 eV. Thermal constants such as absorption and (in)coherent scattering cross sections and corresponding scattering lengths were calibrated to the National Institute of Standards and Technology’s compilation except for 161,164 Dy isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Credible Criticality Safety Margin in the 30B Package with LEU+ UF 6 and Hypothetical Water Ingress

The commercial nuclear industry is pursuing advancements in fuel and reactor design that increase the uranium enrichment above 5 wt. % 235 U. These advancements will necessitate the ability to transport bulk quantities of UF 6 at increased enrichments. Currently, the 30B cylinder is the primary container used by the industry for UF 6 storage and transportation and has a long history of successful shipments. This container can support up to 2,277 kg of UF 6 at a maximum enrichment of 5 wt. % 235 U. Previous evaluations have assessed the potential impact of criticality safety for 30B transport at higher enrichments but assumed moderator intrusion would not require evaluation. Although current regulations allow for the exception of moderator intrusion for UF 6 packages through the design and quality control of the package content, this exception is limited to enrichments up to 5 wt. % 235 U. Thus, an investigation of moderator intrusion into a 30B cylinder should be performed. Moderator intrusion into a 30B cylinder is a unique condition for criticality safety evaluation in transportation because of the violent chemical reactions that occur between UF 6 and H 2 O. The resulting intrusion is strongly dependent on the breach size, breach location, breach interface solid/ullage of the UF 6 content, the UF 6 distribution (which is temperature dependent), and temperature/pressure conditions which are dynamic in accident conditions. Additionally, the complexity of the HF-UO 2 F 2 -H 2 O interface that occurs during the event can influence the potential solubility of uranium in the system, as well as influence the amount of UF 6 reaction with H 2 O. With the operating experience from Orano Federal Services LLC, the UF 6 chemical expertise from Oak Ridge National Laboratory (ORNL), and the criticality safety expertise from ORNL, this paper evaluates the neutronic conditions (i.e., k eff ) that apply the understood chemistry and experimental conditions that occur during moderator intrusion of a breached 30B cylinder under postulated accidents. This report examines the historical evaluations of UF 6 transport and expands these evaluations for the enrichments expected for nuclear industry advancement. These simulations primarily feature a homogeneous mixture of UF 6 and H 2 O as an infinite media system and as a sphere with water reflection given an impurity limit of 0.5 wt. % UF 6 . This report demonstrates that this H/U limit is valid up to 8 wt. % enrichment for both H 2 O and HF as the moderating mixture. The water-reflected homogeneous mixed spheres evaluated demonstrate the amount of safety margin applied by restricting the 30B cylinder impurity limit to 0.5 wt. %. Additionally, this report evaluates moderator ingress scenarios of a 30B cylinder. The 30B cylinder simulations vary the cylinder orientation, the mass of UF 6 in the system, the mass of H 2 O in the system, and how much H 2 O has reacted with UF 6 . The moderator ingress of a 30B cylinder was evaluated for the water-reflected homogeneous mixed spheres to demonstrate the amount of safety margin applied by restricting the 30B cylinder impurity limit to 0.5 wt. %. These simulations are standard practice and are independent of the UF 6 -H 2 O reaction. This work also explored more complex simulations that layer the H 2 O over the UF 6 , which incorporates the amount of reacted UF 6 as a separate layer and considers solubility limits of UO 2 F 2 in H 2 O as it is produced. This approach is intended to simulate the postulated event of a large hairline crack occurring on a submerged cylinder. Finally, this work considers the potential of H 2 O mixing into the UF 6 solid heterogeneously using a sponge-like model. The water ingress into the UF 6 is treated as random size spheres, and the reaction products form into a layer over the spheres.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

UNF-ST&DARDS Enhancements for RCCA Data in As-loaded Dual Purpose Cask Models

This report summarizes the work performed to enable detailed modeling of rod cluster control assembly (RCCAs) in dual purpose canisters (DPCs) in as-loaded configurations using the Used Nuclear Fuel – Storage, Transportation & Disposal Analysis Resource and Data System (UNF-ST&DARDS). The goal of this project was to evaluate the reactivity impact that RCCAs have on k eff of DPCs with pressurized water reactor (PWR) fuel to potentially use the additional margin in future post-closure criticality safety analysis. This preliminary evaluation determined the number of DPCs that currently require compensatory actions prior to emplacement in a repository because of their high reactivity under post-closure criticality scenarios, which could be made acceptable by including the as-loaded RCCAs as specified in the Unified Database (UDB). This report briefly describes the modeling methods currently used within UNF-ST&DARDS and the modifications made to automate inclusion of the as-loaded RCCAs in the DPCs for post-closure criticality calculations for the loss of neutron absorber (NA) scenarios, or NA models. For the Zion site, the loss of basket scenarios, or degraded basket (DB) models, are also included. Discussion is also provided regarding the UDB data compared to available site-specific loading map data for the sites, which are specifically evaluated herein. This report compares the modifications to a similar evaluation for the Zion by site conducted by Walker as an initial validation. After the partial validation, all existing PWR sites with applicable NA models within the UDB were evaluated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluating the 238 U PFNS Including Chi-Nu Experimental Data

This report documents an evaluation of 238 U prompt fission neutron spectra (PFNS) which is a deliverable for a FY2024 Q4 NCSP (Nuclear Criticality Safety Program) milestone. This evaluation is new; its prior input is based on extended Los Alamos and exciton models implemented in the code CoH. Experimental covariances were estimated for five experimental data sets. One of these data sets that was measured by the Chi-Nu team of LANL and LLNL. It covers the 238 U PFNS for continuous incident-neutron energies of 1–20 MeV and outgoing-neutron energies from 10 keV– 10 MeV with high precision. Contrary to Chi-Nu data, previous data sets were measured in a limited energy range. The resulting evaluated data correspond well to the experimental PFNS taken into account for the evaluation. The evaluated PFNS also produce average mean energies in agreement with associated Chi-Nu data. If one uses the new evaluated data to predict the neutron multiplication factor, k eff , of the Flattop, Flattop-Pu and BigTen ICSBEP critical assemblies (which all have thick reflectors with high percentages of 238 U), the differences of simulated values compared to those using ENDF/B-VIII.1β3 is modest (less than 25 pcm). In addition to that, the new PFNS predict on average 238 U LLNL pulsed-sphere neutron-leakage spectra slightly better than ENDF/BVIIII.0 and ENDF/B-VIII.1β3 PFNS. The differences are, however, well within the experimental uncertainties.

238U↗