Search NASA⌕ Search

SEARCH · Search NASA

Results for “cross calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The gallium anomaly

In order to test the end-to-end operations of gallium solar neutrino experiments, intense electron-capture sources were fabricated to measure the responses of the radiochemical SAGE and GALLEX/GNO detectors to known fluxes of low-energy neutrinos. Such tests were viewed at the time as a cross-check, given the many tests of 71 Ge recovery and counting that had been routinely performed, with excellent results. However, the four 51 Cr and 37 Ar source experiments yielded rates below expectations, a result commonly known as the Ga anomaly. As the intensity of the electron-capture sources can be measured to high precision, the neutrino lines they produce are fixed by known atomic and nuclear rates, and the neutrino absorption cross section on 71 Ga is tightly constrained by the lifetime of 71 Ge, no simple explanation for the anomaly has been found. To check these calibration experiments, a dedicated experiment BEST was performed, utilizing a neutrino source of unprecedented intensity and a detector optimized to increase statistics while providing some information on counting rate as a function of distance from the source. The results BEST obtained are consistent with the earlier solar neutrino calibration experiments, and when combined with those measurements, yield a Ga anomaly with a significance of approximately 4𝜎, under conservative assumptions. But BEST found no evidence of distance dependence and thus no explicit indication of new physics. In this review we describe the extensive campaigns carried out by SAGE, GALLEX/GNO, and BEST to demonstrate the reliability and precision of their experimental procedures, including 71 Ge recovery, counting, and analysis. We also describe efforts to define uncertainties in the neutrino capture cross section, which now include estimates of effects at the ≲ 0.5% level such as radiative corrections and weak magnetism. With the results from BEST, an anomaly remains even if one retains only the transition to the 71 Ge ground state, whose strength is fixed by the known lifetime of 71 Ge. We then consider the new-physics solution most commonly suggested to resolve the Ga anomaly, oscillations into a sterile fourth neutrino, 𝜈 𝑒 → 𝜈 𝑠 . We find such a solution generates substantial tension with several null experiments, owing to the large mixing angle required. While this does not exclude such solutions – the sterile sector might include multiple neutrinos as well as new interactions – it shows the need for more experimental constraints, if we are to make progress in resolving the Ga and other low-energy neutrino anomalies. We conclude by consider the role future low-energy electron-capture sources could play in this effort.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Non-destructive measurement and real-time monitoring of apple hardness during ultrasonic contact drying via portable NIR spectroscopy and machine learning

Portable near-infrared spectrometer in the spectral range of 900–1700 nm was evaluated for the first time to assess and monitor apple hardness in real-time during ultrasonic drying. Calibration models were developed using PLS and ANN, and their performances were evaluated by internal leave-one-out cross-validation and an external dataset. Several pre-treatments including standard normal variate (SNV), multiplicative scatter correction (MSC), Savitzky–Golay first and second derivatives were employed to examine the effects of spectral variations in hardness prediction. Seven important wavelengths were selected using weighted regression coefficients to develop a simple MLR model to facilitate the model interpretation and circumvent noise. The models using PLS, MLR, and ANN with selected wavelengths predicted the apple hardness with R 2 p of 0.91, 0.91, 0.95, and RMSEP of 14.78, 14.85, and 12.46 N, respectively. Finally, the results indicate that portable NIR spectrometers are quite promising for real-time monitoring of apple hardness during ultrasonic drying.

47 OTHER INSTRUMENTATION↗

The Gaia DR2 parallax zero-point: hierarchical modelling of red clump stars

ABSTRACT The systematic offset of Gaia parallaxes has been widely reported with Gaia’s second data release, and it is expected to persist in future Gaia data. In order to use Gaia parallaxes to infer distances to high precision, we develop a hierarchical probabilistic model to determine the Gaia parallax zero-point offset along with the calibration of an empirical model for luminosity of red clump stars by combining astrometric and photometric measurements. Using a cross-matched sample of red clump stars from the Apache Point Observatory Galactic Evolution Experiment and Gaia Data Release 2 (DR2), we report the parallax zero-point offset in DR2 to be $\varpi _0 = -48 \pm 1\,\mu \text{as}$. We infer the red clump absolute magnitude to be −1.622 ± 0.004 in Ks, 0.435 ± 0.004 in G, −1.019 ± 0.004 in J, and −1.516 ± 0.004 in H. The intrinsic scatter of the red clump is ∼0.09 mag in J, H, and Ks, or ∼ 0.12 mag in G. We tailor our models to accommodate more complex analyses such as investigating the variations of the parallax zero-point with each source’s observed magnitude, observed colour, and sky position. In particular, we find fluctuations of the zero-point across the sky to be of order or less than a few 10s of $\mu \text{as}$.

Chan, Victor C.↗

High-count rate effects in event processing for XRISM/ Resolve X-ray microcalorimeter: I. Ground test

The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. We utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high-count rate measurements and propose modeling approaches to mitigate them. We specifically address the following instrumental effects that impact performance: CPU limit, pile-up, and untriggered electrical cross-talk. Experimental data at high count rates were acquired during ground testing using the flight model instrument and a calibration X-ray source. In the experiment, data processing not limited by the performance of the onboard CPU was run in parallel, which cannot be done in orbit. This makes it possible to access the data degradation caused by limited CPU performance. We use these data to develop models that allow for a more accurate estimation of the aforementioned effects. To illustrate the application of these models in observation planning, we present a simulated observation of GX 13+1. Understanding and addressing these issues is crucial to enhancing the reliability and precision of X-ray spectroscopy in situations characterized by elevated count rates.

47 OTHER INSTRUMENTATION↗

Dehydrogenation vs Apparent Hydrogenation: Unraveling the Mechanisms of He and O 2 Plasma Etching on Colloidal Nanocrystal Films

Removing organic ligands from colloidal nanoparticles is critical for fabricating solid-state devices, yet accurately quantifying this removal remains a significant analytical challenge. Here, we establish a robust and accessible method for this quantification by calibrating Raman spectroscopy against precise ion beam analysis (IBA) for nanoparticle assemblies (CNAs) processed by helium (He) and oxygen (O 2 ) plasmas. We demonstrate that the calibration curves are remarkably independent of plasma power and pressure, depending critically only on the choice of feed gas. He plasma induces rapid dehydrogenation and cross-linking, evidenced by a much faster decrease in the C–H Raman signal relative to the actual carbon loss. Conversely, O 2 plasma leads to a surprising “apparent hydrogenation”, where the carbon backbone is removed significantly faster than the C–H signal diminishes. This counterintuitive effect is explained by a serial mechanism of oxidative fragmentation; β-scission cleaves the alkyl chains, and subsequent stabilization steps enrich the remaining film with hydrogen-rich methyl-terminated fragments, while carbon is efficiently removed as volatile CO. This work provides calibrated functions that enable the rapid determination of absolute carbon content in processed CNAs using simple Raman spectroscopy with uncertainties of ∼8% for O 2 and ∼12% for He plasma, offering a vital tool for both process diagnostics and fundamental studies of plasma–matter interactions in colloidal nanocrystal films.

Animal feed↗

Calibration of the charge and energy loss per unit length of the MicroBooNE liquid argon time projection chamber using muons and protons

In this paper, we describe a method used to calibrate the position- and time-dependent response of the MicroBooNE liquid argon time projection chamber anode wires to ionization particle energy loss. The method makes use of crossing cosmic-ray muons to partially correct anode wire signals for multiple effects as a function of time and position, including cross-connected TPC wires, space charge effects, electron attachment to impurities, diffusion, and recombination. The overall energy scale is then determined using fully-contained beam-induced muons originating and stopping in the active region of the detector. Using this method, we obtain an absolute energy scale uncertainty of 2% in data. We use stopping protons to further refine the relation between the measured charge and the energy loss for highly-ionizing particles. This data-driven detector calibration improves both the measurement of total deposited energy and particle identification based on energy loss per unit length as a function of residual range. As an example, the proton selection efficiency is increased by 2% after detector calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A leaf-level spectral library to support high-throughput plant phenotyping: predictive accuracy and model transfer

Abstract Leaf-level hyperspectral reflectance has become an effective tool for high-throughput phenotyping of plant leaf traits due to its rapid, low-cost, multi-sensing, and non-destructive nature. However, collecting samples for model calibration can still be expensive, and models show poor transferability among different datasets. This study had three specific objectives: first, to assemble a large library of leaf hyperspectral data (n=2460) from maize and sorghum; second, to evaluate two machine-learning approaches to estimate nine leaf properties (chlorophyll, thickness, water content, nitrogen, phosphorus, potassium, calcium, magnesium, and sulfur); and third, to investigate the usefulness of this spectral library for predicting external datasets (n=445) including soybean and camelina using extra-weighted spiking. Internal cross-validation showed satisfactory performance of the spectral library to estimate all nine traits (mean R2=0.688), with partial least-squares regression outperforming deep neural network models. Models calibrated solely using the spectral library showed degraded performance on external datasets (mean R2=0.159 for camelina, 0.337 for soybean). Models improved significantly when a small portion of external samples (n=20) was added to the library via extra-weighted spiking (mean R2=0.574 for camelina, 0.536 for soybean). The leaf-level spectral library greatly benefits plant physiological and biochemical phenotyping, whilst extra-weight spiking improves model transferability and extends its utility.

59 BASIC BIOLOGICAL SCIENCES↗

PI3NN: Out-of-distribution-aware Prediction Intervals from Three Neural Networks

We propose a novel prediction interval (PI) method for uncertainty quantification, which addresses three major issues with the state-of-the-art PI methods. First, existing PI methods require retraining of neural networks (NNs) for every given confidence level and suffer from the crossing issue in calculating multiple PIs. Second, they usually rely on customized loss functions with extra sensitive hyperparameters for which fine tuning is required to achieve a well-calibrated PI. Third, they usually underestimate uncertainties of out-of-distribution (OOD) samples leading to over-confident PIs. Our PI3NN method calculates PIs from linear combinations of three NNs, each of which is independently trained using the standard mean squared error loss. The coefficients of the linear combinations are computed using root-finding algorithms to ensure tight PIs for a given confidence level. We theoretically prove that PI3NN can calculate PIs for a series of confidence levels without retraining NNs and it completely avoids the crossing issue. Additionally, PI3NN does not introduce any unusual hyperparameters resulting in a stable performance. Furthermore, we address OOD identification challenge by introducing an initialization scheme which provides reasonably larger PIs of the OOD samples than those of the in-distribution samples. Benchmark and real-world experiments show that our method outperforms several state-of-the-art approaches with respect to predictive uncertainty quality, robustness, and OOD samples identification.

Liu, Siyan↗

Effective ZDC cross section derived from Vernier Scans during the RHICf run with polarized protons at 255 GeV in 2017

At RHIC the collision rate per IP is measured by the Zero Degree Calorimeters (ZDC). The collision rate, as measured by the ZDC, corresponds to the rate of mutual forward neutral particles above a variable threshold and within a certain coincidence window. During run 17 the detector was operated for the RHICf experiment in a slightly different configuration from the earlier standard polarized proton run. Due to the different configuration the ZDC detector was calibrated for the rhicf setup by performing a set of dedicated vernier scans. A total of 9 vernier scans were performed. This note presents the data and summarizes the results, i.e. effective ZDC cross section from those scans for the rhicf running period.

43 PARTICLE ACCELERATORS↗

Calibration of large neutron detection arrays using cosmic rays

Cosmic muons are used to calibrate the position, light output and the relative timing offset of the Large Area Neutron Array (LANA). Each 2 × 2 m 2 LANA wall consists of twenty-five horizontal neutron detection bars. Each bar is 2 m long with a cross-section of 6.35 × 7.62 cm 2 Pyrex container filled with NE-213 organic scintillation liquid. The average position and time resolution of a bar is found to be about 8 cm and 500 ps FWHM, respectively. Furthermore, our method provides an accurate, fast and convenient calibration of LANA that can be applied to general scintillation arrays without the use of radioactive sources or beams.

79 ASTRONOMY AND ASTROPHYSICS↗

The Pixel Luminosity Telescope: a detector for luminosity measurement at CMS using silicon pixel sensors

The Pixel Luminosity Telescope is a silicon pixel detector dedicated to luminosity measurement at the CMS experiment at the LHC. It is located approximately 1.75 m from the interaction point and arranged into 16 “telescopes”, with eight telescopes installed around the beam pipe at either end of the detector and each telescope composed of three individual silicon sensor planes. The per-bunch instantaneous luminosity is measured by counting events where all three planes in the telescope register a hit, using a special readout at the full LHC bunch-crossing rate of 40 MHz. The full pixel information is read out at a lower rate and can be used to determine calibrations, corrections, and systematic uncertainties for the online and offline measurements. This paper details the commissioning, operational history, and performance of the detector during Run 2 (2015–18) of the LHC, as well as preparations for Run 3, which will begin in 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extend an innovative HPC-Compatible Multiple Temporal-spatial Resolution Concurrent Finite Element Modeling Approach to Guide Laser Powder Bed Fusion Additive

Laser power bed fusing (PBF) additive manufacturing is a key enabling technology to manufacture highly complex and integrated automotive structures. However, the geometric complexity of PBF-AM technique also leads to highly non-uniform heating and cooling rate in the manufactured part, which may cause flaw formation and produce excessive and nonuniform residual stresses, which increase quality uncertainties and manufacture issues, leading to increases in cost and energy consumption in the form of rejected parts. In this research project, we developed an innovative Multi-Spatial-Temporal-Resolution Finite Element (MUST-FE) method and completed the corresponding high performance computation (HPC) platform-based in-house code, which enables high accuracy prediction of temperature and residual stress fields for component-scale PBF-AM manufacture in efficient computation time. The MUST-FE model is calibrated and validated with a “2D pad” AlSi10Mg experiments by matching the melt pool shape and dimension, and with a “XY-cross” AlSi10Mg experiment by matching the thermal distortion and residual stress. The innovative multi-resolution and concurrent modeling approach adopted in this code ensures accuracy and computational efficiency, which will enable energy-efficient and high-yield, low-cost manufacturing of optimized, qualifiable automotive structures and contribute towards reaching technical targets outlined in AMO’s Program Plan to develop additive manufacturing systems that deliver consistently reliable parts with predictable properties.

36 MATERIALS SCIENCE↗

X-ray beam monitoring and wavelength calibration using four-beam diffraction

Rigorous dynamical theory calculations show that four-beam diffraction (4BD) can be activated only by a unique photon energy and a unique incidence direction. Thus, 4BD may be used to precisely calibrate X-ray photon energies and beam positions. Based on the principles that the forbidden-reflection 4BD pattern, which is typically an X-shaped cross, can be generated by instant imaging using the divergent beam from a point source without rocking the crystal, a detailed real-time high-resolution beam (and source) position monitoring scheme is illustrated for monitoring two-dimensional beam positions and directions of modern synchrotron light sources, X-ray free-electron lasers and nano-focused X-ray sources.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SITCOMTN-162: Testing the implementation of Metadetection and Cell-Based Coadds on Abell 360 LSSTComCam data

The purpose of this technote is to test the technical quality of LSSTComCam commissioning data, specifically the Rubin_SV_38_7 field, by utilizing cell-based coadds and Metadetection by measuring the tangential and cross weak lensing shear profiles of the massive cluster Abell 360 (called A360 throughout the technote). The process entails generating the cell-based coadds for Metadetection to run on, identifying and removing cluster member galaxies, applying quality cuts, calibrating the shear measurements, and validation. Cell-based coadds and Metadetection are both currently in the process of being implemented within the LSST Science Pipelines at the time of this technote. There is substantial technical value in attempting a difficult measurement prior to full implementation. Measuring the tangential shear around A360 will showcase the current abilities of these algorithms, as well as highlight where work is still needed. As seen from the resulting shear profile of A360, the cell-based coadds and Metadetection are able to work in tandem to produce a shear catalog and resulting reduced shear profile. This technote is one part of a series studying A360 in order to both stress test the commissioning camera and demonstrate the technical capabilities of the Vera Rubin Observatory. We study the quality of the PSF modeling and impact it can have on cluster WL in [Combet et al., 2025], implementation of cell-based coadds and subsequent use for Metadetect [Sheldon et al., 2023] in this technote, photometric calibration in (in prep), source selection and photometric redshifts in [Adari et al., 2025], use of Anacal [Li et al., 2024] to produce a cluster shear profile in [Li et al., 2025], and background subtraction in this field and Fornax in [Zhou et al., 2025].

79 ASTRONOMY AND ASTROPHYSICS↗

Hawaii Wave Surge Energy Converter (HAWSEC) OSU O.H. Hinsdale Basin

The following information and metadata applies to both the Phase I (Hydrodynamics) and Phase II (Full System Power Take-Off) zip folders which contain testing data from the OSU (Oregon State University) O.H. Hinsdale Wave Research Laboratory, from both OSU and the University of Hawaii at Manoa (UH). See zip folders provided further below in the downloads section. For experimental data of the full system, including PTO, see Phase II dataset. There are two main directories in each Phases's zip folder: "OSU_data" and "UH_data". The "OSU_data" directory contains data collected from their DAQ (data acquisition system), which includes all wave gauge observations, as well as body motions derived from their Qualisys motion tracking system. The organization of the directory follows OSU's convention. Detailed information on the instrument setup can be found under "OSU_data/docs/setup/instm_locations". The experiments conducted are documented in the "OSU_data/docs/daq_logs", which provides the trial number to the corresponding data located under "OSU_data/data" in several formats (e.g., ".mat" and ".txt"). Inside the trial directory, data is provided for each of the instruments defined in "OSU_data/docs/setup/instm_locations". The "UH_data" directory contains data collected from their DAQ. The data is stored in a ".tdms" file format. There are free plug-ins for Microsoft Excel and MathWorks MATLAB to read the ".tdms" format. Below are a few links providing methods to read in the data, but a Google search should identify alternatives sources if these no longer exist (valid as of January 2024): Excel: http://www.ni.com/example/27944/en/ MATLAB: https://www.mathworks.com/matlabcentral/fileexchange/30023-tdms-reader The Excel plugin is recommend to get a quick overview of the data. The UH data is organized by directory name, in which the sub-directories for each experiment contains a directory whose name defines the wave height and period for the experimental data within. For example, a directory name "H02_T0275" corresponds to an experiment with wave height 0.1m and a period of 2.75s. For random wave data, the gamma value is also included in the directory name. For example, a directory name "H02_T0225_G18" corresponds to an experiment with a significant wave height of 0.2m, a peak period of 2.25s, and a gamma value of 1.8, with each spectra being a TMA spectrum. For the free decay experiments, the directory name is defined by the initial angular displacement. For example, a directory name "ang05_run01" corresponds to an experiment with an initial angular displacement of 5 degrees. There is a dataset in the UH data for each corresponding experiment defined in the OSU DAQ logs. The ".tdms" data is output from the DAQ at fixed intervals. Therefore, if multiple files are contained within the folder, the data will need to be stitched together. Within the UH dataset, there are two input channels from the OSU DAQ providing a random square wave signal for time synchronization ("ENV-WHT-0010") and a high/low signal ("ENV-WHT-0012") to identify when the wave maker is active (+5V). The UH data is logged as a collection of channel outputs. Channels not in use for the OSU testing (either Phase I or Phase II) are marked "nan" below. If the sensor is disconnected, it will record noise throughout the experiment. Below are the channel definitions in terms of what they measure: GPS Time = time CYL-POS-0001 = position between flap and fixed reference CYL-LCA-0001 = force between flap and hydraulic cylinder REC-LPT-0001 = nan REC-HPT-0001 = nan REC-HPT-0002 = nan REC-HPT-0003 = nan HHT-HPT-0001 = pressure at exhaust ("head" only) REC-FQC-0001 = nan REC-FQC-0002 = nan HHT-FQC-0001 = flow at exhaust ("head" only) ENV-WHT-0001 = nan ENV-WHT-0002 = nan ENV-WHT-0003 = nan ENV-WHT-0010 = random signal from OSU DAQ ENV-WHT-0012 = high/low signal from OSU DAQ Also included is a calibration curve to convert the string pot data to flap pi...

16 TIDAL AND WAVE POWER↗

Adaptive spectra-to-exposure conversion using ridge regularized polynomial response models

Real-time gamma spectra-to-exposure conversion in aerial and ground monitoring commonly relies on calibration-derived, detector- or system-specific conversion coefficients that are assumed to generalize across operational environments. In practice, deployment specific differences in spectral composition and transport conditions can introduce systematic bias relative to reference instruments, motivating methods that adapt coefficients using minimal field supervision while explicitly limiting overfitting. In this work, we present a conservative coefficient adaptation framework that updates a baseline polynomial energy-weighting function using ridge-regularized regression, with leave-one-out cross-validation (LOOCV) used to select the regularization strength. The findings support ridge-constrained minimal-supervision adaptation as a practical mechanism to suppress site-specific bias without destabilizing a calibration-derived baseline.

61 RADIATION PROTECTION AND DOSIMETRY↗

Toward Muon Neutrino Charged-Current Neutral Pion Cross Section Measurements at ICARUS

At ICARUS and the broader Short-Baseline Neutrino Program, few neutrino interaction channels offer as much utility as those producing neutral pions, which are an important background to electron neutrino searches and provide a standard candle for calibrating the electromagnetic shower energy scale. Beyond this, measurements of neutrino-induced neutral pions offer a probe of resonant interactions that are relevant to future accelerator neutrino experiments like the Deep Underground Neutrino Experiment. In this document, a measurement of charged-current muon neutrino interactions in liquid argon with a single neutral pion in the final state is presented, making use of neutrino interaction events recorded with the ICARUS T600 detector at Fermilab while exposed to the Booster Neutrino Beam. Event selection is carried out with a fully-automated machine learning reconstruction framework, allowing for the extraction of single-differential cross section measurements as a function of muon and neutral pion kinematic observables.

Carber, Dan [Colorado State U.]↗

Initial Calibration of Large Timing Arrays for the LHC

In preparation for HL-LHC operation a number of new detector systems are being constructed with timing precision on physics objects of <50 picoseconds. These time stamps will reduce the level of pileup induced backgrounds in this LHC phase where the number of interactions per crossing will reach of order 100-200. In the case of CMS, three new systems have initially to be corrected for the usual amplitude walk resulting from the effect of variations in signal size on leading edge timing. In these systems the resulting timing spread (ie walk) ranges from one to four nanoseconds. In the following note we advocate approaching this initial calibration for walk as a calculable correction given early calibration during commissioning -- rather than depending on special collider data to perform the calibration. We derive a simple analytic expression for the walk correction and confirm its effectiveness with lab data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗